• Title/Summary/Keyword: High ozone concentration

Search Result 298, Processing Time 0.025 seconds

Analysis of Time Series Models for Ozone Concentration at Anyang City of Gyeonggi-Do in Korea (경기도 안양시 오존농도의 시계열모형 연구)

  • Lee, Hoon-Ja
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.604-612
    • /
    • 2008
  • The ozone concentration is one of the important environmental issue for measurement of the atmospheric condition of the country. This study focuses on applying the Autoregressive Error (ARE) model for analyzing the ozone data at middle part of the Gyeonggi-Do, Anyang monitoring site in Korea. In the ARE model, eight meteorological variables and four pollution variables are used as the explanatory variables. The eight meteorological variables are daily maximum temperature, wind speed, amount of cloud, global radiation, relative humidity, rainfall, dew point temperature, and water vapor pressure. The four air pollution variables are sulfur dioxide $(SO_2)$, nitrogen dioxide $(NO_2)$, carbon monoxide (CO), and particulate matter 10 (PM10). The result shows that ARE models both overall and monthly data are suited for describing the oBone concentration. In the ARE model for overall ozone data, ozone concentration can be explained about 71% to by the PM10, global radiation and wind speed. Also the four types of ARE models for high level of ozone data (over 80 ppb) have been analyzed. In the best ARE model for high level of ozone data, ozone can be explained about 96% by the PM10, daliy maximum temperature, and cloud amount.

A study on high ozone concentration in Shiwha.Banwol industry complex using photochemical air pollution model- Analysis of meteorological characteristics - (시화.반월단지지역의 고농도 오존일에 대한 광화학모델 적용 연구 - 기상특성에 대한 분석 -)

  • An, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.47-59
    • /
    • 2011
  • The purpose of this paper is to simulate the high ozone concentration in Shiwha Banwol indusrial complex. High pollution episodes (ozone alert) of this area are the results of geographical location and its air pollutants emission. This research has used meteorological model (RAMS) and photochemical air pollution Model (CIT model). As first step of the evaluate of this combined model system simulations are done in terms of meteorological characteristics like wind fields, PBL-height, etc.. Numerical simulations are carried out with real meteorological synoptic data on June. 24-25, 2010. In comparison with real measurement and another research the model reflects well local meteorological phenomena and shows the possibility to be utilized to analyse the pollutant dispersion over irregular terrain region. The high ozone concentration is deeply correlated to the ambient air temperature, wind speed and solar radiation. Local meteorological phenomena like sea-land breeze impact on horizontal dispersion of ozone. This analysis of meteorological characteristics can, in turn, help to predict their influences on air quality and to manage the high ozone episodes.

Influences of Mesh Shapes and Interspacings on Ozone Generation Characteristics (그물방전극 형상과 방전공격이 오존생에 미치는 영향)

  • Park, Seung-Lok;Lee, Jae-Chan;Moon, Jae-Duk;Jung, Sung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.29-32
    • /
    • 2000
  • Ozone has been widely applied to many industrial fields because of its strong oxidation effects. Therefore, the studies have been progressed for the effective and high concentration of one generation. The silent or surface discharge have been mainly used for high concentration ozone generation until now. But these two types of ozone generators have shortcomings to be improved. In this study, the ozone generator which improved the shortcomings of above two type of ozone generators was proposed and manufactured for high concentration ozone generation. And the proposed ozone generator could generate the surface and barrier discharge simultaneously. For this purpose, a mesh type discharge electrodes were proposed and the experiments were fulfilled as a function of the widths and spacings of mesh electrodes and gap spacings between the dielectric barrier and mesh electrode. When the width of mesh electrode[WM] and spacing of mesh electrode[SM] are 0.3[mm] and 0.8[mm] respectively, the maximum ozone concentration of 2.96[vol%] was obtained at 5.6[kV], 830[mA], gap spacing (S)=0.65[mm].

  • PDF

Analysis of Ozone Concentration by TD and Q-mass Method

  • Lee, Dong-Gyu;Lee, Joon-Ung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.161-165
    • /
    • 2004
  • In order to get oxidizing power enough for growth of a superconductive thin film with oxide gas, concentrated ozone was used. As a method for concentrating ozone, a method for concentrating ozone by adsorbing ozone selectively into silica-gel beads is adopted, and this concentration is analyzed by the ultraviolet absorption method, the thermal decomposition method and the Q-mass analyzing method. Thermal decomposition method is most effective for measurement of a high concentration of ozone. Ozone as concentrated by the adsorption method got to have a concentration of 97 mol % at the maximum, and it was identified that the concentration of the ozone gas was stable for the time while a thin film was formed.

Analysis on the Effect of Meteorological Factors related to Difference of Ozone Concentration at the Neighboring Areas in Gijang Busan (인접지역간 오존 농도 차이에 대한 기상요소의 영향분석(부산광역시 기장군을 대상으로))

  • Kim, Min-Kyoung;Lee, Hwa-Woon;Jung, Woo-Sik;Do, Woo-Gon
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1097-1113
    • /
    • 2012
  • Ozone is the secondary photochemical pollutant formed from ozone precursor such as nitrogen dioxide and non-methane volatile organic compounds(VOCs). The ambient concentration of ozone depends on several factors: sunshine intensity, atmospheric convection, the height of the thermal inversion layer, concentrations of nitrogen oxides and VOCs. Busan is located in the southeast coastal area of Korea so the ozone concentration of Busan is mainly affected from the meteorological variables related to the sea such as sea breeze. In this study the ozone concentrations of Busan in 2008~2010 were used to analyse the cause of the regional ozone difference in eastern area of Busan. The average ozone concentration of Youngsuri was highest in Busan however the average ozone concentration of Gijang was equal to the average ozone concentration of Busan in 2008~2010. The two sites are located in eastern area of Busan but the distance of two sites is only 9km. To find the reason for the difference of ozone concentration between Youngsuri and Gijang, the meteorological variables in two sites were analyzed. For the analysis of meteorological variables the atmospheric numerical model WRF(Weather Research and Forecasting) was used at the day of the maximum and minimum difference in the ozone concentration at the two sites. As a result of analysis, when the boundary layer height was lower and the sea breeze was weaker in Youngsuri, the ozone concentration of Youngsuri was high. Furthermore when the sea breeze blew from the south in the eastern area of Busan, the sea breeze at Youngsuri turned into the southeast and the intensity of sea breeze was weaker because of the mountain in the southern region of Youngsuri. In that case, the difference of ozone concentration between Youngsuri and Gijang was considerable.

Evaluation of the Effect of Regional Pollutants and Residual Ozone on Ozone Concentrations in the Morning in the Inland of the Kanto Region

  • Kiriyama, Yusuke;Shimadera, Hikari;Itahashi, Syuichi;Hayami, Hiroshi;Miura, Kazuhiko
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • Increasing ozone concentrations are observed over Japan from year to year. One cause of high ozone concentration in the Kanto region, which includes areas inland from large coastal cities such as metropolitan Tokyo, is the transportation of precursors by sea breezes. However, high ozone concentrations are also observed in the morning, before sea breezes approach inland areas. In this point, there would be a possibility of residual ozone existing above the nocturnal boundary layer affects the ozone concentration in the following morning. In this study, we utilized the Weather Research and Forecasting model and the Community Multiscale Air Quality model to evaluate the effect of regional precursors and residual ozone on ozone concentrations over the inland Kanto region. The results show that precursors emitted from non-metropolitan areas affected inland ozone concentrations more than did precursors from metropolitan areas. Moreover, calculated results indicate downward transportation of residual ozone, resulting in increased concentration. The residual ozone was also affected by precursors emitted from non-metropolitan areas.

Dependence of Ozone Generation in a Micro Dielectric Barrier Discharge on Dielectric Material and Micro Gap Length

  • Sakoda, Tatsuya;Sung, Youl-Moon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.201-206
    • /
    • 2004
  • In order to investigate the optimum conditions for the effective ozone formation in a dielectric barrier discharge, measurements of ozone concentration were carried out for various conditions such as the gap length, the dielectric material and the operating gas. It was found that the optimum discharge conditions differed exceedingly in the types of operating gases and dielectric materials. In dry air, dielectric material with low dielectric constant and thermal conductivity, which might contribute to the restriction of the gas temperature rise in the discharge region, proved effective in obtaining both high ozone yield and concentration. The optimum gap length was considered to be in the range of 600-800 mm. In oxygen, using a quartz glass disk as a dielectric material, the required condition to obtain the high ozone yield and concentration was expanded.

High Efficiency Photoresist Strip Technology by using the Ozone/Napor Mixture (오존/증기 혼합물을 이용한 고효율 반도체 감광막 제거기술)

  • Son, Young-Su;Ham, Sang-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.22-23
    • /
    • 2006
  • A process for removal of photoresist(PR) m semiconductor manufacturing using water vapor with ozone is presented. For the realization of the ozone/vapor mixture process, high concentration ozone generator and process facilities have developed. As a result of the silicon wafer PR strip test, we confirmed the high efficiency PR strip rates of 400nm/mm or more at the ozone concentration of 16wt%/$O_2$. The ozone/vapor mixture process is more effective than the ozonized water Immersion process.

  • PDF

Construction and Evaluation of $O_3$ Condensation System for Oxide Thin Film (산화 박막 성장을 위한 $O_3$ 농축 시스템의 구축 및 평가)

  • Lim, Jung-Kwan;Ryu, Sun-Jong;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1192-1195
    • /
    • 2003
  • A highly condensed ozone gas be transferred to the superconductor thin film growth chamber because ozone is strong oxidizing gas. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper an ozone condensation system was evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Ozone was condensed by an adsorption method and the ozone concentration reached 8.5 mol% in 2.5 h after the beginning of the ozone condensation process, indicating high effectiveness of the condensation process. Ozone was continuously desorbed from the silica gel by the negative pressure.

  • PDF

Evaluation of Oxidation System for Metal Oxide Thin Film (금속 산화물 박막 제작을 위한 산화 시스템의 평가)

  • 임중관;김종서;박용필
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.590-593
    • /
    • 2003
  • Ozone is a strong and useful oxidizing gas for the fabrication of oxide thin films. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper an ozone condensation system was evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Crone was condensed by an adsorption method and the ozone concentration reached 8.5 mol% in 2.5 h after the beginning of the ozone condensation process, indicating high effectiveness of the condensation process. Ozone was continuously desorbed from the silica gel by the negative pressure. We found the decomposition in the ozone concentration negligible if the condensed ozone is transferred from the ozone condensation system to the film growth chamber within a few minutes.

  • PDF