• 제목/요약/키워드: High order aberrations

검색결과 27건 처리시간 0.021초

근시에서의 라섹과 TransPRK라섹 수술 후 고위수차 비교 (After Lasek Surgeried and TransPRK Surgeried for Myopia, Comparison of High-order Aberrations)

  • 박준성
    • 한국임상보건과학회지
    • /
    • 제3권2호
    • /
    • pp.372-377
    • /
    • 2015
  • Purpose: The aim of this study is to compare total high order aberrations between surgery which uses TransPRK and general laser assisted sub-epithelial keratomileusis. Methods: The patients who had general laser assisted sub-epithelial and TransPRK laser assisted sub-epithelial by visiting ophthalmic clinic in Ulsan from January 2014 to August 2014 was researched. Results: When comparing total high order aberrations before and after operation, it was found that total high order aberration in general laser assisted sub-epithelial group increased to $0.222{\pm}0.078{\mu}m$ from $0.074{\pm}0.019{\mu}m$ while that in TransPRK assisted sub-epithelial group increased to $0.179{\pm}0.045{\mu}m$ from $0.076{\pm}0.032{\mu}m$. When comparing the increment in total high order aberrations between two groups after surgery, it was found that the increments of TransPRK assisted sub-epithelial group were statistically smaller than that of general laser assisted sub-epithelial group (p<0.05). Conclusions: This study made a comparative analysis of total high order aberrations between general laser assisted sub-epithelial and TransPRK assisted sub-epithelial which was introduced recently and the result showed a significant difference. The findings of this study suggest that TransPRK assisted sub-epithelial can be used widely in simply improving eye sight and quality of vision by reducing an increase in high order aberration caused by orthokeratology surgery. It is expected that TransPRK assisted sub-epithelial will be helpful for improving the understanding quality of eye sight which occurs by several methods of vision correction surgery.

High-order Reduced Radial Zernike Polynomials for Modal Reconstruction of Wavefront Aberrations in Radial Shearing Interferometers

  • Tien Dung Vu;Quang Huy Vu;Joohyung Lee
    • Current Optics and Photonics
    • /
    • 제7권6호
    • /
    • pp.692-700
    • /
    • 2023
  • We present a method for improving the accuracy of the modal wavefront reconstruction in the radial shearing interferometers (RSIs). Our approach involves expanding the reduced radial terms of Zernike polynomials to high-order, which enables more precise reconstruction of the wavefront aberrations with high-spatial frequency. We expanded the reduced polynomials up to infinite order with symbolic variables of the radius, shearing amount, and transformation matrix elements. For the simulation of the modal wavefront reconstruction, we generated a target wavefront subsequently, magnified and measured wavefronts were generated. To validate the effectiveness of the high-order Zernike polynomials, we applied both low- and high-order polynomials to the wavefront reconstruction process. Consequently, the peak-to-valley (PV) and RMS errors notably decreased with values of 0.011λ and 0.001λ, respectively, as the order of the radial Zernike polynomial increased.

홀로그래픽 HMD 소자의 수차 및 시야각 향상에 관한 연구 (A study on aberration and FOV improvement of a holographic HMD element)

  • 김희동;정만호
    • 한국광학회지
    • /
    • 제12권5호
    • /
    • pp.418-424
    • /
    • 2001
  • 수차가 적고 넓은 시야각에 걸쳐 높은 회절효율을 보이는 홀로그래픽 HMD 소자를 설계, 제작하였다. 적은 수차를 갖는 홀로그래픽 광학소자를 설계하기 위하여 recursive 설계 방법이 사용되었다. 적은 수차뿐만 아니라 넓은 FOV에 걸쳐 높은 회절효율을 갖도록 하기 위해 매개 홀로그램을 사용하였으며, 이를 이용해 수차가 보정된 홀로그램의 격자 함수를 최종적인 홀로그램에 전송하였다. 제작된 최종의 HMD용 홀로그래픽 광학소자의 수차는 보정 전보다 10배 가량 향상되었으며 FOV는 $\pm$$10^{\circ}$를 나타내었다.

  • PDF

소프트콘택트렌즈 재질에 따른 눈물막 파괴시간과 고위수차의 비교 (Comparison of tear film break-up time and high order aberration according to soft contact lens material)

  • 김봉환;한선희;김학준;배상아;손유진;김지현;김현지
    • 한국임상보건과학회지
    • /
    • 제7권1호
    • /
    • pp.1232-1237
    • /
    • 2019
  • Purpose. In this study, two types of soft contact lenses with different materials were selected to compare the time of tear film destruction and high order aberrations before and after wearing. Methods. Thirty patients (60 eyes) in their 20s were included in this study. Two lenses with different materials, Group 4 (Etafilcon A) and Group 5 (Narafilcon A) were selected. Using aberration analyzer and keratometry, high-order aberration and tear film test (NIF-BUT, NIAvg-BUT) were performed before and after wearing. Results. When comparing the higher aberrations of the Etafilcon A and Narafilcon A lenses, the higher aberrations of the Narafilcon A lens were higher overall. For the initial tear film break-up time (NIF-BUT) after wearing, the Etafilcon A lens was reduced by 4.0 seconds and the Narafilcon A lens increased by 0.6 seconds. For the mean tear film break-up time (NIAvg-BUT) after wearing, the Etafilcon A lens decreased by 2.4 seconds and the Narafilcon A lens increased by 1.7 seconds. Conclusions. NIF-BUT and NIAvg-BUT of Narafilcon A lens were increased. The lens with relatively low water content and higher oxygen permeability than the lens with high water content has relatively less tear evaporation, which means that the time of destruction of the tear film is increased.

Design of a Tele-centric Wide Field Lens with High Relative Illumination and Low Distortion Using Third-order Aberration Analysis

  • Kim, Kae-Hong;Kim, Yeong-Sik;Park, Sung-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.679-686
    • /
    • 2015
  • This paper presents a design method for improving the low relative illumination and large distortion due to widening the field of a system. A tele-centric optical system in image space was suggested to increase the relative illumination. Through the analyses of the third-order aberrations affected by introducing aspherical surfaces, we have proposed a method to determine analytically what surface should be aspheric to correct each aberration effectively. By utilizing this method to design a wide field lens, a tele-centric wide field lens with f-number of F/2.0 was obtained. Even though the field angle is 120 degrees, it has a very low distortion less than -2% and high relative illumination more than 73.7%. In conclusion, this analytic method for selecting aspherical surfaces is expected to serve as a useful way to find design solutions.

Compact Zoom Lens Design for a 5x Mobile Camera Using Prism

  • Park, Sung-Chan;Lee, Sang-Hun;Kim, Jong-Gyu
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.206-212
    • /
    • 2009
  • This study presents the compact zoom lens with a zoom ratio of 5x for a mobile camera by using a prism. The lens modules and aberrations are applied to the initial design for a four-group inner-focus zoom system. An initial design with a focal length range of 4.4 to 22.0 mm is derived by assigning the first-order quantities and third-order aberrations to each module along with the constraints required for optimum solutions. We separately designed a real lens for each group and then combined them to establish an actual zoom system. The combination of the separately designed groups results in a system that satisfies the basic properties of the zoom system consisting of the original lens modules. In order to have a slim system, we directly inserted the right-angle prism in front of the first group. This configuration resulted in a more compact zoom system with a depth of 8 mm. The finally designed zoom lens has an f-number of 3.5 to 4.5 and is expected to fulfill the requirements for a slim mobile zoom camera having high zoom ratio of 5x.

Zoom Lens Design for a 10x Slim Camera using Successive Procedures

  • Park, Sung-Chan;Lee, Sang-Hun
    • Journal of the Optical Society of Korea
    • /
    • 제17권6호
    • /
    • pp.518-524
    • /
    • 2013
  • This study presents a new design method for a zoom lens, in which real lens groups are designed successively to combine to form a lens modules zoom system. The lens modules and aberrations are applied to the initial design for a four-group inner-focus zoom system. An initial design with a focal length range of 4.2 to 39.9 mm is derived by assigning the first-order quantities and third-order aberrations to each module along with the constraints required for optimum solutions. After obtaining the lens module zoom system, the real lens groups are successively, not separately, designed to get a zoom lens system. Compared to the separately designed real lens groups, this approach can give a better starting zoom lens and save time. The successively designed groups result in a zoom system that satisfies the basic properties of the zoom system consisting of the original lens modules. In order to have a slim system, we directly inserted the right-angle prism in front of the first group. This configuration resulted in a compact zoom system with a depth of 12 mm. The finally designed zoom lens has an f-number of 3.5 to 4.5 and is expected to fulfill the requirements for a mobile zoom camera having high zoom ratio of 10x.

조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교 (Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils)

  • 김봉환;한선희;박병규;황현주;배예솔;서정빈;여예은;윤민정;김학준
    • 한국임상보건과학회지
    • /
    • 제4권2호
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.

Chinese Hamster Lung 세포를 이용한 염색체이상 시험을 이용한 CP약침의 유전독성평가 (Evaluation of Genotoxicity of CP Pharmacopuncture Using an In Vitro Chromosome Aberration Test in Chinese Hamster Lung Cell)

  • 황지혜;정철;구자승
    • 동의생리병리학회지
    • /
    • 제34권6호
    • /
    • pp.355-361
    • /
    • 2020
  • This study was designed to assess the toxicity of capsaicin-containing (CP) pharmacopunture using an in vitro chromosomal aberrations in Chinese hamster lung (CHL/IU) cells. In order to determine the high dose level in the main study of this study, a dose range finding study was conducted first. The high dose was selected at 10.0% of CP pharmacopuncture extract, and then diluted sequentially to produce lower dose levels of 5.00, 2.50, 1.25, 0.625 and 0.313% by applying a geometric ratio of 2. As a result, the cytotoxicity and precipitation of the CP pharmacopuncture as a test substance were not evident at any dose level during short-time treatment with and without metabolic activation and continuous treatment without metabolic activation. Therefore, the dose levels for this study were chosen as 10.0, 5.0, and 2.5%., and the treatment volume was 1.3 mL. In addition, negative and positive controls were set. In main study, the frequency of cells with chromosome aberrations in CP treated groups was less than 5% in short-time treatment with and without metabolic activation and continuous treatment without metabolic activation. In addition, there was no statistically significant difference when compared to the negative control group. The frequency of cells with structural chromosomal aberrations in the positive control group was more than 10% compared to the negative control group, and it increased statistically significantly. In conclusion, under the conditions of this study, CP pharmacopuncture did not show the possibility of causing chromosome aberrations.

굴절교정수술을 받은 근시안의 각막 비구면도와 광학적 특성 평가 (Corneal Asphericity and Optical Performance after Myopic Laser Refractive Surgery)

  • 김정미;이아영;이군자
    • 한국안광학회지
    • /
    • 제18권2호
    • /
    • pp.179-186
    • /
    • 2013
  • 목적: 엑시머 레이저 근시굴절교정수술을 받은 사람의 각막 비구면도, 시력, 고위수차를 정시안과 비교 평가하였다. 방법: 단안의 나안 시력이 1.0 이상인 근시 굴절교정수술을 받은 23명(나이: $23.0{\pm}2.5$세)과 20명($21.0{\pm}2.6$세)의 정시안을 대상으로 밝은 조명(photopic)과 중등도(mesopic) 조명상태에서 대비도를 가지는 시력표(100% 및 10%)를 이용하여 시력검사를 하였고, wavefront 수차 분석기(KR-1W, Topcon, Japan)를 이용하여 각막의 비구면계수와 4mm와 6 mm의 동공크기에 따른 눈 전체의 고위수차와 각막의 고위수차를 측정하여 비교하였다. 결과: 굴절교정 수술안과 정시안에서 대비도에 따른 시력은 유의한 차이를 보이지 않았다. 안구 수차(ocular aberrations)에서 전체 고위수차, 4차수차, 구면수차는 동공크기 6 mm상태에서 굴절교정 수술안에서 높게 나타났고, 두 그룹 사이에 유의한 차이를 보였다(p=0.045, p<0.001, p<0.001). 각막의 구면 수차(corneal spherical aberrations)는 동공크기 4 mm와 6 mm상태에서 모두 굴절교정 수술 안에서 더 높게 측정되었고 유의한 차이를 보였다(p<0.01, p<0.001). 각막의 전체고위수차와 4차수차는 동공크기 6 mm 상태에서만 굴절교정 수술안에서 더 크게 나타났고 통계적으로 유의하였다(p<0.001, p<0.001). 정시안의 비구면계수와 구면수차는 동공크기 4 mm와 6 mm 상태에서 안구 수차(r=0.442, p=0.004, r=0.519, p<0.001) 와 각막수차(r=0.358, p=0.023, r=0.646, p<0.001) 모두에서 유의한 상관성을 나타내었으나, 굴절교정 수술안에서는 상관성이 없었다. 결론: 각막굴절교정 수술안의 경우 시력은 정상수준을 나타내고 있으나 동공크기가 커지면 수차가 증가하여 동공이 커지는 야간에는 시력의 질에 영향을 줄 수 있을 것으로 사료된다.