• Title/Summary/Keyword: High luminance

Search Result 550, Processing Time 0.028 seconds

Light Emission and Plasma Property in the External Electrode Fluorescent Lamps (외부전극 형광램프의 발광 및 플라즈마 특성)

  • Ahn, S.;Lee, M.;Jeong, J.;Kim, J.;Yoo, D.;Koo, J.;Kang, J.;Hong, B.;Choi, E.;Cho, G.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.3
    • /
    • pp.172-180
    • /
    • 2007
  • A new diagnostics of plasma electron temperature and plasma density is introduced with the observation of the light emission along the tube of external electrode fluorescent lamps. With two different methods operating an external electrode fluorescent lamp of outer diameter 4.0 mm and length 860 mm for the back-light source of 37-inch LCD-TVs, the lighting modes and the plasma properties are investigated. In the center balance operation, the light-emission propagates simultaneously from both sides of the high voltage electrodes to the center of the lamp, while in conventional operation the light-emission propagates from the one end of a high voltage to the other ground electrode. In the operation value of luminance $10,000{\sim}15,000cd/m^2$, the electron plasma thermal energy $(kT_e)$ is about $1.3{\sim}2.7eV$ with the electron density $(n_e)$ is about $(1.6{\sim}3.6){\times}10^{16}m^{-3}$.

Development of Image Quality Enhancement of a Digital Camera with the Application of Exposure To The Right Exposure Method (ETTR 노출 방법을 활용한 디지털 카메라의 화질 향상)

  • Park, Hyung-Ju;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.95-103
    • /
    • 2010
  • Raw files record luminance values corresponds to each pixel of a digital camera sensor. In digital imaging, controlling exposure to capture the first highlight stop is important on linear-distribution of raw file characteristic. This study sought to verify the efficiency of ETTR method and found the optimum over-exposure amount to maintain the first highlight stop to be the largest number of levels. This was achieved by over-exposing a scene with a raw file and converting it to under-exposure in a raw file converting software. Our paper verified the efficiency of ETTR by controlling the exposure range and ISOs. Throughout the results, if exposure increases gradually 6 steps, dynamic range is also increased. And it shows that the optimized exposure value is around + $1\frac{2}{3}$ stop over compared to the normal exposure with the high ISOs simultaneously. We compared visual noise value at $1\frac{2}{3}$ stop to the normal exposure visual noise. Based on the normal exposure's visual noise, we can confirm that visual noise decrement is increased by increasing ISOs. In this experimental result, we confirm that overexposure about + $1\frac{2}{3}$ stop is the optimum value to make the widest dynamic range and lower visual noise in high ISOs. Based on the study results, we can provide the effective ETTR information to consumers and manufacturers. This method will contribute to the optimum image performance in maximizing dynamic range and minimizing noise in a digital imaging.

The Optical Characteristics of 240 W High Power LED Fish Luring Lamp (240W급 고출력 LED 집어등의 광학적 특성)

  • Bae, Jae-Hyun;An, Heui-Chun;Kim, Sang-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.6
    • /
    • pp.681-687
    • /
    • 2013
  • This study analyzed characteristics of 240 W high power LED lamps by comparing with those of traditional metal halide lamps. In addition, it analyzed the propriety of LED lamps as a source of light, considering seawater transmission characteristics. When Applying white LED package with the color temperature color temperature of 6500K, a 240W-LED fishing lamp has a characteristics of the luminous angle to be expanded to ${\pm}45^{\circ}$, the illumination change was improved to 0.8, as well as the luminance efficiency was improved to 98.8lm/W. As results of comparison between one 1,500W-metal halide lamp and four 240W-LED lamp with considering a seawater transmission and a luminous efficiency of scotopic vision, the radiant flux of two lamps were almost equal level at 50m depth and the luminous flux was 5% higher LED lamp than metal-halide lamp even if only applying the luminous efficiency of scotopic vision. As the luminous flux of LED lmap was 14% higher than that of metal-halide lamp with applying the luminous efficiency of scotopic vision to radiant flux at 50m depth, so LED fishing lamp was verified to alternative possibility of metal-halide lamp.

Study on the Optical Characteristics of the Green Phosphor for PDP Application (PDP용 녹색 형광체의 광 특성 개선에 관한 연구)

  • Han, Bo Yong;Yoo, Jae Soo
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.150-156
    • /
    • 2009
  • Plasma Display Panels(PDPs) require to have improved luminous efficiency, low manufacturing cost, and high image quality to compete with other flat display devices such as Liquid Crystal Displays(LCDs) and organic light-emitting diodes(OLEDs). In addition, the diversity of product line-up may be needed for high market share. In this paper, the optical characteristics of typical green phosphor for PDP application are reviewed and the problem-based solution will be proposed. We also shortly describe the principle of 3D-PDPs which are promising. Then, the requirement of green phosphor for 3D-PDP application is summarized and research achievement, as of now, is described. The typical problems of $Zn_2SiO_4:Mn$ phosphor, which is the most well-known, are the negatively charged surface property and the long decay time, which leads to unstable discharge in green cell and afterimage. These problems were solved by coating the phosphor surface with metallic oxide. It was found that $Al_2O_3$ would be the best material for $Zn_2SiO_4:Mn$ phosphor. It gives longevity as well as low operating voltage due to the charging effect in green cells. Also, new phosphors, $(Y,\;Gd)Al_3(BO_3)_4:Tb$ and $(Mg,\;Zn)Al_2O_4:Mn$ phosphor are proposed for increasing the luminance and reducing the decay time, which are capable to apply for 3D-PDP application.

A License Plate Recognition System Robust to Vehicle Location and Viewing Angle (영상 내 차량의 위치 및 촬영 각도에 강인한 차량 번호판 인식 시스템)

  • Hong, Sungeun;Hwang, Sungsoo;Kim, Seongdae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.113-123
    • /
    • 2012
  • Recently, various attempts have been made to apply Intelligent Transportation System under various environments and conditions. Consequently, an accurate license plate recognition regardless of vehicle location and viewing angle is required. In this paper, we propose a novel license plate recognition system which exploits a) the format of license plates to remove false candidates of license plates and to extract characters in license plates and b) the characteristics of Hangul for accurate character recognition. In order to eliminate false candidates of license plates, the proposed method first aligns the candidates of license plates horizontally, and compares the position and the shape of objects in each candidate with the prior information of license plates provided by Korean Ministry of Construction & Transportation. The prior information such as aspect ratio, background color, projection image is also used to extract characters in license plates accurately applying an improved local binarization considering luminance variation of license plates. In case of recognizing Hangul in license plates, they are initially grouped according to their shape similarity. Then a super-class method, a hierarchical analysis based on key feature points is applied to recognize Hangul accurately. The proposed method was verified with high recognition rate regardless of background image, which eventually proves that the proposed LPR system has high performance regardless of the vehicle location or viewing angle.

Evaluation of Blue Light Hazards in LED Lightings (LED 조명에 대한 청색광 위험 평가)

  • Jung, Myoung Hoon;Yang, Seok-Jun;Yuk, Ju Sung;Oh, Sang-Young;Kim, Chang-Jin;Lyu, Jungmook;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.293-300
    • /
    • 2015
  • Purpose: To evaluate blue light hazards of LED lightings in an optical store with blue light radiance used as the quantitative indicators of photobiological hazard. Methods: The spectral radiance of each LED lightings was measured, and blue-light radiance and the corresponding maximum exposure time were calculated. Then each LED lighting was classified according to the risk group from IEC 62471 standard. Results: The yellow LED lightings used in showcases and white LED lightings used on ceilings and logo were classified into risk group RG0. But the white LED lightings used on showcases were classified into risk group RG1. The blue light radiances of white LED lightings used in showcases are dozens of times larger than that of fluorescent lamp. Conclusions: Using the value of the blue light radiance could quantitatively express the blue light hazard to various lightings. It was confirmed that white LED lightings for the showcases had high blue light hazards because of their high luminance and color temperature. Therefore, when replacing lightings in optical shop it is necessary to select the appropriate brightness and color temperature for eye health in the long term.

Design of Video Encoder activating with variable clocks of CCDs for CCTV applications (CCTV용 CCD를 위한 가변 clock으로 동작되는 비디오 인코더의 설계)

  • Kim, Joo-Hyun;Ha, Joo-Young;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.80-87
    • /
    • 2006
  • SONY corporation preoccupies $80\%$ of a market of the CCD used in a CCTV system. The CCD of SONY have high duality which can not follow the progress of capability. But there are some problems which differ the clock frequency used in CCD from the frequency used in common video encoder. To get the result by using common video encoder, the system needs a scaler that could adjust image size and PLL that synchronizes CCD's with encoder's clock So, this paper proposes the video encoder that is activated at equal clock used in CCD without scaler and PLL. The encoder converts ITU-R BT.601 4:2:2 or ITU-R BT.656 inputs from various video sources into NTSC or PAL signals in CVBS. Due to variable clock, property of filters used in the encoder is automatically changed by clock and filters adopt multiplier-free structures to reduce hardware complexity. The hardware bit width of programmable digital filters for luminance and chrominance signals, along with other operating blocks, are carefully determined to produce hish-quality digital video signals of ${\pm}1$ LSB error or less. The proposed encoder is experimentally demonstrated by using the Altera Stratix EP1S80B953C6ES device.

Application of Computer-Aided Diagnosis for the Differential Diagnosis of Fatty Liver in Computed Tomography Image (전산화단층촬영 영상에서 지방간의 감별진단을 위한 컴퓨터보조진단의 응용)

  • Park, Hyong-Hu;Lee, Jin-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.443-450
    • /
    • 2016
  • In this study, we are using a computer tomography image of the abdomen, as an experimental linear research for the image of the fatty liver patients texture features analysis and computer-aided diagnosis system of implementation using the ROC curve analysis, from the computer tomography image. We tried to provide an objective and reliable diagnostic information of fatty liver to the doctor. Experiments are usually a fatty liver, via the wavelet transform of the abdominal computed tomography images are configured with the experimental image section, shows the results of statistical analysis on six parameters indicating a feature value of the texture. As a result, the entropy, average luminance, strain rate is shown a relatively high recognition rate of 90% or more, the control also, flatness, uniformity showed relatively low recognition rate of about 70%. ROC curve analysis of six parameters are all shown to 0.900 (p = 0.0001) or more, showed meaningful results in the recognition of the disease. Also, to determine the cut-off value for the prediction of disease six parameters. These results are applicable from future abdominal computed tomography images as a preliminary diagnostic article of diseases automatic detection and eventual diagnosis.

Edge Enhanced Error Diffusion Halftoning Method Using Local Activity Measure (공간활성도를 이용한 에지 강조 오차확산법)

  • Kwak Nae-Joung;Ahn Jae-Hyeong
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.3
    • /
    • pp.313-321
    • /
    • 2005
  • Digital halftoning is a process to produce a binary image so that the original image and its binary counterpart appear similar when observed from a distance. Among digital halftoning methods, error diffusion is a procedure for generating high quality bilevel images from continuous-tone images but blurs the edge information in the bilevel images. To solve this problem, we propose the improved error diffusion using local spatial information of the original images. Based on the fact that the human vision perceives not a pixel but local mean of input image, we compute edge enhancement information(EEI) by appling the ratio of a pixel and its adjacent pixels to local mean. The weights applied to local means is computed using the ratio of local activity measure(LAM) to the difference between input pixels of 3$\times$3 blocks and theirs mean. LAM is the measure of luminance changes in local regions and is obtained by adding the square of the difference between input pixels of 3$\times$3 blocks and theirs mean. We add the value to a input pixel of quantizer to enhance edge. The performance of the proposed method is compared with conventional methods by measuring the edge correlation. The halftone images by using the proposed method show better quality due to the enhanced edge. And the detailed edge is preserved in the halftone images by using the proposed method. Also the proposed method improves the quality of halftone images because unpleasant patterns for human visual system are reduced.

  • PDF

Development of OSL Dosimetry Reader (선량 판독용 OSL 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • Design and performance test results of a newly developed optically stimulated luminescence (OSL) measurement system are presented in this paper. Generally, different types of optical filters are used in OSL reader system to minimize the interference of the stimulation light in the OSL signal. For optically stimulation of $Al_2O_3:C$, we have arrived at an optimal combination of the filters, i.e., GG420 filter for filtering the stimulating light source, and a combined UG11 and BG39 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optically stimulation. By using various control boards, the OSL reader device was successfully interfaced with a personal computer. A software was developed to deliver required commands to operate the OSL reader by using the LabView program (National Instruments, Inc.). In order to evaluate the reliability and the reproducibility of newly designed-OSL reader. Performance testing of the OSL reader was carried out for OSL efficiency, OSL decay curve and signal to noise ratio of the standard $Al_2O_3:C$ OSL material. It was found to be comparable with that of commercial Riso reader system.