• 제목/요약/키워드: High intensity light source

검색결과 132건 처리시간 0.025초

Preliminary study on the visual sensitivity of Oreochromis niloticus using LED light source for the aquaculture development in Uganda

  • Esther Kagoya;Kyoungmi Kang
    • Fisheries and Aquatic Sciences
    • /
    • 제26권8호
    • /
    • pp.514-523
    • /
    • 2023
  • The visible threshold of Oreochromis niloticus responded to high light intensity under short wavelengths, whereas the response to low light intensity under long wavelengths was low, with a minimum visual threshold of 574 nm of LED lights. Movement distance of O. niloticus was dropped at 31℃ and increased abnormally at 37℃ under natural light. Comparing movement distance under red (622 nm) and green (518 nm) lights of LED, movement distance and swimming speed under red and green lights were higher than under natural light. However, the movement distance decreased rapidly at 31℃ under red light and lowest at 33℃ under green light. After that, there was a tendency to adapt to high water temperatures gradually. Consequently, red and green lights may be recommended for O. niloticus's aquaculture because the red and green lights have a positive effect on growth performance, survival rate, and metabolism, as shown in previous studies. It is necessary to control the water temperature below 32℃ because abnormal behavior above 32℃ revealed under red and green LED lights and natural light.

프리즘 필름을 이용한 조명기구 설계 연구 (A Study on Light Guide Luminaire Design using Prismatic Film)

  • 정학근;한수빈;정봉만;이의준
    • KIEAE Journal
    • /
    • 제2권2호
    • /
    • pp.33-38
    • /
    • 2002
  • There are a number of practical uses for devices which are capable of piping large amounts of light: illumination of areas where there would be maintenance, safety, or security problems with electronic light sources; piping sunlight into indoor areas for illumination; and the conversion of high luminous efficacy, good color quality, high intensity discharge lamps into more acceptable linear of area sources of light. Prism light guides are hollow structures which pipe light by means of total internal reflectin(TIR). These devices are unique in their ability to combine the efficiency of TIR with the relatively low cost of hollow structure. An important application stems from their ability to transform a point source of light such as an incandescent or discharge lamp into a linear or area source of light or illumination. We report the development of an economical, flexible prismatic film for fabricating the light guide wall. This guide geometries and films are currently under development.

광합성 기구 조작을 통한 비유황 자색 광합성 세균, Rhodobacter sphaeroides의 생산성 증대 (The improvement of productivity of a photosynthetic purple bacterium, Rhodobacter sphaeroides by manipulating the photosynthetic apparatus)

  • 김낙종;이철균
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.189-192
    • /
    • 2000
  • 광합성 홍색세균의 light harvesting complex II (LHC II)발현 유전자가 제거된 돌연변이종을 halogen 램프 하에서 거리에 따라 광도를 달리하며 배양하여 wild type과 생산성을 비교한 결과 낮은 광도(34 ${\mu}E/m^2/s$)에서는 wild type가 높은 광도 (376, 118 ${\mu}E/m^2/s$)에서는 mutant가 높은 세포농도를 나타내었다. 특히 118 ${\mu}E/m^2/s$에서 LHC $II^-$ mutant가 56% 높은 세포생산량을 보였다. 이는 세포내 pigment양의 감소로 mutual shading effect가 감소하였기 때문으로 판단되었다.

  • PDF

Study on the Design of a High Condensing LED Searchlight

  • Kim, Tae-Seong;Kim, Jin-Wook;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권4호
    • /
    • pp.201-205
    • /
    • 2015
  • This paper dealt with the condensing technology of an LED light source that uses a parabolic reflector to replace a searchlight equipped with a xenon lamp. A ray-tracing simulation was conducted to analyze the influence of the diameter of the reflector and the size of the light source on light condensing. The combination of a parabolic reflector with a diameter of 620 mm and a focal distance of 220 mm, and a 9 mm multi-chip package (MCP) with a luminous flux of 7,000 lm showed the narrowest beam angle. The luminous intensity at the center was measured at 7.7×106 cd. The distance between the light source and the point where the illuminance was 1 lx was calculated to be 2.8 km. The power consumption of the system was 95 W, which is only 9.5% of that of the 1 kW xenon searchlight, and the beam angle was 1.03°. In a site experiment, it was confirmed that the light ray reflected from the LED searchlight proceeds forward without any diffusion because of the narrow beam angle.

영상처리에 의한 위상잠금 열화상기법의 최적화 연구 (Optimization of Lock-in Thermography Technique using Phase Image Processing)

  • 조용진;한송이
    • 한국해양공학회지
    • /
    • 제26권5호
    • /
    • pp.25-30
    • /
    • 2012
  • This study examined the use of LIT (lock-in infrared thermography) to detect defects in the welded parts of ships and offshore structures. A quantitative analysis was used with the filtering and texture measurement of image processing techniques to find the optimized experimental condition. We verified the reliability of our methods by applying image processing techniques in order to normalize the evaluations of comparative images that showed a phase difference. In addition, it was found that a low to mid-range intensity of light exposure on the surface showed good results, whereas high exposure did not provide significant results. A lock-in frequency of around 0.1 Hz was satisfactory regardless of the intensity of the light source. In addition, making the integration time of the thermography camera inversely proportional to the intensity of the exposed light source during the experiment provided good results.

집적화된 Lab-On-a Chip을 위한 광센서의 제작 및 특성 평가 (Development of Photo-sensor for Integrated Lab-On-a-Chip)

  • 김주환;신경식;김용국;김태송;김상식;주병권
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.404-409
    • /
    • 2004
  • We fabricated photo-sensor for fluorescence detection in LOC. LOC is high throughput screening system. Our LOC screens biochemical reaction of protein using the immunoassay, and converts biochemical reaction into electrical signal using LIF(Laser Induced Fluorescence) detection method. Protein is labeled with rhodamine intercalating dye and finger PIN photodiode is used as photo-sensor We measured fluorescence emission of rhodamine dye and analyzed tendency of fluorescence detection, according to photo-sensor size, light intensity, and rhodamine concentration. Detection current was almost linearly proportional to two parameters, intensity and concentration, and was inversely proportional to photo-sensor size. Integrated LOC consists of optical-filter deposited photo-sensor and PDMS microchannel detected 50 (pg/${mu}ell$) rhodamine. For integrated LOC including light source, we used green LED as the light source and measured emitted fluorescence.

치과 수술용 LED 광원모듈의 최적화 (The Optimization of an Operating Dental LED Light Source Module)

  • 정연오;홍기태;김재열;김성현;안영진;한재호
    • 한국생산제조학회지
    • /
    • 제20권4호
    • /
    • pp.452-457
    • /
    • 2011
  • The internal temperature of an operating room had to keep within $20^{\circ}C$. However, the doctor who is wearing operating gown and mask caused to rise temperature because of the thermal occurrence of dental LED light source. At first, the surgery environment is getting worse. And then last, it would increase bleeding rate by the expansion of patient's exposured blood vessel. A surgical operator can distribute the patient's tissue through such surgery environment, exactly. It can do accurate surgery. So, it gave to effect that surgical operator's eye condition is getting better and it could keep a mutual assistance system. For this research, we develop the LED dental light source module of high color rendition. It performed simulation for replacing established the method of Halogen lamp and Plazma lamp of light source. We analyzed intensity of illumination and the change of viability by changing the height of light source module.

고광도 섬광의 안전지표로서 노출제한거리 (Exposure-Limit Distance as a Safety-Indicating Parameter of a High-Intensity Flash Source)

  • 박승만;김상욱
    • 한국광학회지
    • /
    • 제28권1호
    • /
    • pp.16-21
    • /
    • 2017
  • 고광도 섬광에 의하여 사람 눈에 미치는 영향을 체계적으로 이해하는 것은 고섬광의 사용상에나 눈의 보건의학적인 관점에서 큰 가치가 있다. 본 논문에서는 고섬광의 안전지표로서 노출제한거리를 제안하고, 섬광의 특성으로부터 노출제한 노출제한거리를 구하는 방법을 제시한다. 본 연구에서 고려한 고섬광에 대한 노출제한을 결정하는 요인은 망막에서 투영되는 열적 에너지이며 이는 망막의 열적위험을 나타내는 열적유효복사휘도로 표현된다. 고섬광의 노출제한거리는 열적 유효복사휘도 또는 광도와 광원 반경에 거의 비례하나 지속시간에는 거의 의존하지 않는다. 고섬광의 노출제한거리가 지속시간에 비례하지 않는다는 점은 눈에 미치는 영향이 노출되는 시간에 비례할 것이라는 기대와는 다른 중요한 발견으로 생각된다. 본 연구에서 제안된 노출제한거리는 고섬광의 연구개발과 활용에서 뿐만 아니라 눈을 보호하는 보건의학 분야에서도 안전지표로서 중요하게 활용될 것으로 기대된다.

LASER-PRODUED PLASMA AS AN X-RAY SOURCE

  • 김효근
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1991년도 제6회 파동 및 레이저 학술발표회 Prodeedings of 6th Conference on Waves and Lasers
    • /
    • pp.64-64
    • /
    • 1991
  • The interaction of high-intensity, focused, nanosecond laser light with matter results in the production of high-temperature plasma, which in turn emits an intense pulse of x rays. The x-ray spectrum consists of strong line components of several keV photon energy and broad continuum. Such an x-ray source provides many advantages over conventional ones for many applications. Pulse nature of the x-ray emission is well-suited for studying transient phenomena and for imaging living biological specimen. Recent experiments have also shown that the laser plasma x ray may be used for x ray lithography. These studies and other applications will be discussed in detail.

  • PDF

고휘도 발광다이오드(LED)의 광학적 특성에 관한 연구 (A Study of Optical Characteristics for High Intensity LED)

  • 황명근;임종민;신상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2159-2161
    • /
    • 2000
  • The LEDs are used for signal lights including traffic signals and telecommunication equipments. Advanced foreign countries are making R&D of ultra high intensity LEDs, and the LEDs are expected to new light source. Optical characteristics by measurements of 14 LEDs; each 2 of 3$\Phi$ R/G/Y LEDs, each of 5$\Phi$ Y/G/Y LEDs and each of high intensity 5$\Phi$ R/G/B/A/W LEDs. Comparison on chromaticity coordinate of high intensity 5$\Phi$ White LED by forward V/I.

  • PDF