오존발생용 세라믹 방전관 특성에 관한 연구 (A Study on Characteristic of Ceramic Tube for Ozone Generation)

  • 조국희;김영배;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1724-1726
    • /
    • 2002
  • A novel ozonizer has been developed using a high-frequency surface discharge and a high purity alumina ceramic as its dielectric component. A thin ceramic layer, cylindrical in form, is adhered by a film-like induction electrode. An ac exciting voltage of frequency to 0.6 kHz from 1.0 kHz and $6{\sim}9kV$ peak-to-peak is applied between the electrodes to produce a stable high-frequency silent discharge for generation of ozone. A substantial reduction of the exciting voltage is also enabled by using a thin alumina ceramic layer. As a result, the ozonizer can easily produce ozone concentration($128g/m^2$ for oxygen) and power efficiency(360g/kWh for oxygen) without using a special enrichment means.

  • PDF

인버터용 고주파 변압기의 효율 향상을 위한 코어 형상 최적화 설계에 대한 연구 (A Study on Core shape optimization to Improve The Efficiency of High Frequency Transformer for Inverter)

  • 유진형;정태욱
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.29-35
    • /
    • 2014
  • The purpose of high frequency transformer in the inverter is to reduce the voltage and current stresses of switch components when it operates at the large conversion ratio. But the loss of transformer is the major contributor in the efficiency of inverter. This paper presents the method of core design to minimize the loss of transformer. The total loss of transformer is minimized by adjusting the effective cross-sectional areas of core. The component ratio of losses are compared by using the finite-element analysis.

Investigation of Typhoon Wind Speed Records on Top of a Group of Buildings

  • Liu, Min;Hui, Yi;Li, Zhengnong;Yuan, Ding
    • 국제초고층학회논문집
    • /
    • 제8권4호
    • /
    • pp.313-324
    • /
    • 2019
  • This paper presents the analysis of wind speeds data measured on top of three neighboring high-rise buildings close to a beach in Xiamen city, China, during Typhoon "Usagi" 2013. Wind tunnel simulation was carried out to validate the field measurement results. Turbulence intensity, turbulence integral scale, power spectrum and cross correlation of recorded wind speed were studied in details. The low frequency trend component of the typhoon speed was also discussed. The field measurement results show turbulence intensity has strong dependence to the wind speed, upwind terrain and even the relative location to the Typhoon center. The low frequency fluctuation could severely affect the characteristics of wind. Cross correlation of the measured wind speeds on different buildings also showed some dependence on the upwind terrain roughness. After typhoon made landfall, the spatial correlation of wind speeds became weak with the coherence attenuating quickly in frequency domain.

심박변이율 주파수 분석을 통한 실내온도에 따른 건강한 성인의 자율신경계 활동 평가 (Evaluation of the Ambient Temperature Effect for the Autonomic Nervous Activity of the Young Adult through the Frequency Analysis of the Heart Rate Variability)

  • 신항식
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1240-1245
    • /
    • 2015
  • The purpose of this paper is to investigate the autonomic nervous system activity in various ambient temperatures. To evaluate autonomic function, we use the frequency domain analysis of heart rate variability such as FFT(fast fourier transformation), AR(Auto-Regressive) model and Lomb-Scargle peridogram. HRV(heart rate variability) is calculated by using ECG recorded from 3 different temperature room which temperature is controlled in 18℃(low), 25℃(mid) and 38℃(high), respectively. Totally 22 subjects were participated in the experiment. In the results, the most significant autonomic changes caused by temperature load were found in the HF(high frequency) component of FFT and AR model. And the HF power is decreased by increasing temperature. Significance level was increased by increasing the difference of temperatures.

Image Global K-SVD Variational Denoising Method Based on Wavelet Transform

  • Chang Wang;Wen Zhang
    • Journal of Information Processing Systems
    • /
    • 제19권3호
    • /
    • pp.275-288
    • /
    • 2023
  • Many image edge details are easily lost in the image denoising process, and the smooth image regions are prone to produce jagged. In this paper, we propose a wavelet-based image global k- singular value decomposition variational method to remove image noise. A layer of wavelet decomposition is applied to the noisy image first. Then, the image global k-singular value decomposition (IGK-SVD) method is used to remove the random noise of low-frequency components. Furthermore, a constructed variational denoising method (VDM) removes the random noise in the high-frequency component. Finally, the denoised image is obtained by wavelet reconstruction. The experimental results show that the proposed method's peak signal-to-noise ratio (PSNR) value is higher than other methods, and its structural similarity (SSIM) value is closer to one, indicating that the proposed method can effectively suppress image noise while retaining more image edge details. The denoised image has better denoising effects.

고 에너지 밀도 펄스 변압기 설계 (Design of A High Energy Density Pulse Transformer)

  • 남상훈;박성수;하기만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2186-2188
    • /
    • 1999
  • A high frequency and energy density pulse transformer is a critical component of a high voltage power supply in a traveling wave tube (TWT) amplifier system. In this paper, processes of design, manufacturing, and test of the transformer are discussed. Primary voltage of the transformer is 240 V. The transformer secondary have two outputs which are 4100 V (Helix) and 2050 V (Collector). Total output power is 860 W. Normal operating frequency of the transformer is 10 kHz. In high energy density pulse transformers, temperature rise is a main problem during its operation. From our study, it was found that resonant current due to leakage inductance and stray capacitance was the main cause of temperature rise. This happens because of the inherently high turn-ratio in high voltage transformers. Solutions to reduce stray components are presented.

  • PDF

FIR 필터를 이용한 전력계통의 주파수 추정기법 (Estimation Technique of Frequency using FIR Filter in the Power System)

  • 남시복;박철원;신명철
    • 전기학회논문지P
    • /
    • 제50권3호
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출 (Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation)

  • 전학재;김정도;임승주
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

에어컨 용 횡단류 홴의 특정 주파수 소음 성분의 저감 대책에 관한 연구 -날개의 랜덤 배열과 경사진 스태빌라이저에 대한 연구- (A Study on the Reduction of Discrete Frequency Tones of a Cross-Flow Fan of Air-Conditioners -Studies on the Random Distribution of Fan Blades and the Skewed Stabilizers-)

  • 구형모
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.870-878
    • /
    • 1998
  • The cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll casing is widely used in many air-ventilating and air-conditioning devices. Its ooperating points of high efficiency and loading conditions frequently induce a annoying sharp tonal component of discrete frequency on the noise spectrum, which is open called as a BPF(Blade-Passing-Frequency) noise and degrades the sound quality of the devices. this BPF tone has been one of the defects of the cross-flow fan. This study proposes two methods in order to reduce this tonal noise component, which are the random distributions of the fan blades and the skewed shapes of the stabilizer. The proposed methods are verified by a simple analytical model and are applied in manufacturing the cross-flow fan and the stabilizer samples. Some experiments are carried out to verify the reduction capability of BPF tones of above two schemes and the experimental results are analyzed. The comparison between two method is also carried out.

  • PDF

Wavelet 변환을 이용한 고장 전류의 판별에 관한 연구 (A Study on the Application of Wavelet Transform to Faults Current Discrimination)

  • 정종원;조현우;김태우;이준탁
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2002년도 추계학술대회 및 정기총회
    • /
    • pp.427-430
    • /
    • 2002
  • Recently the subject of "wavelet analysis" has be drawn by both mathematical and engineering application fields such as Signal Processing, Compression/Decomposition, Wavelet-Neural Network, Statistics and etc. Even though its similar to Fourier analysis, wavelet is a versatile tool with much mathematical content and great potential for applications. Especially, wavelet transform uses localizable various mother wavelet functions in time-frequency domain. Therefore, wavelet transform has good time-analysis ability for high frequency component, and has good frequency-analysis ability for low frequency component. Using the discriminative ability is more easy method than other conventional techniques. In this paper, Morlet wavelet transform was applied to discriminate the kind of line fault by acquired data from real power transformation network. The experimental result presented that Morlet wavelet transform is easier,and more useful method than the FFT (Fast Fourier Transform).