• Title/Summary/Keyword: High frequency Vibration

검색결과 1,357건 처리시간 0.027초

자동차 도어 진동의 파워흐름해석에 대한 실험적 연구 (Experimental Study on Power Flow Analysis of Vibration of an Automobile Door)

  • 길현권;이용현;이규형;황성국;홍석윤;박영호;서진관;채기상;서성훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.782-785
    • /
    • 2006
  • The Power Flow Analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency range. In this paper, Power Flow Finite Element Method (PFFEM) based on PFA has been used to predict the vibration of an automobile door. The predicted results for the frequency response function of the door have been compared with corresponding experimental results. In the experiment, the automobile door has been divided into several subsystems and the loss factor of each subsystem has been measured. The input mobility at a source point has been also measured. The data for the loss factors and the input mobility have been used as the input data to predict the vibration of the automobile door with PFFEM. The frequency response functions have been measured over the surface of the door. The comparison between the experimental results and the predicted results for the frequency response functions showed that PFFEM could be an effective tool to predict the structural vibration.

  • PDF

초고주파수 진동 감지를 위한 이온 질량기반 진동센서 (Ion-Based Micro Vibration Sensor for Ultra-High Frequency Vibration Detection)

  • 김광호;서영호
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.728-732
    • /
    • 2008
  • This paper presents ion-based micro vibration sensor for the ultra-high frequency vibration detection. Presented sensor uses the motion of anion and cation in an electrolyte. Electrolyte vibration sensors have the high shock survival characteristics and a simple read-out circuit because of the small mass and own charges of ions. Presented sensor measures the induced electric potential by the mechanical-electrical coupling. It consist of electrolyte chamber and detection electrode. Electrolyte chamber was fabricated by PDMS molding. Detection electrode was made of gold evaporation on pyrex glass. Size of electrolyte chamber was designed as $600{\times}600{\times}100um$. Detection electrode had 200nm-thick and 42um-gap. In the experimental study, 5.8M sodium Chloride (NaCl) solution was used as electrolyte in 36nl-chamber. Mechanical vibration was measured from 2kHz to 4MHz.

진동 절연계에서 절연요소 회전강성계수가 고주파수 대역 진동파워 전달에 미치는 영향 (Effects of Rotational Stiffness of Isolators on Vibration Power Transmission in Vibration Isolation Systems over High Frequency Range)

  • 김진성;이호정;김광준
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.375-383
    • /
    • 2003
  • For a performance analysis of vibration isolation systems, the concept of vibration power flow can be employed preferably when noise radiated from the supporting structure with finite impedances is of interest. The idea is basically simple to understand and formulas for precise estimation of the vibration power are easy to derive. However, It is often required to simplify the process of experimentation under several assumptions due to instrumental limitations. For an example, rotational degree of freedom has not been well treated in bending vibrations of beam or plate-like structures. Yet, several recent studies showed that the moments and rotations play an important role in power transmission and should be taken into consideration carefully as the frequency range of interest goes to audibly high. Therefore, it is readily agreed that reduction of the noise radiation over the high frequency range can be effectively accomplished by adjusting the rotational stiffness of the isolator without changing the vibration isolator efficiency in low frequency range relevant to the translational stiffness of the isolator In this paper, the vibration power flow approach is applied to an AC motor installed on a finite plate in order to illustrate the contribution of the rotational vibration power to the total vibration power transmission. The effects of rotational stiffness of the isolator on the vibration power transmission are investigated by inserting various shapes of Isolators with different rotational stiffness but with $ame translational stiffness between the motor and the plate. The resultant noise radiation from the plate is presented to verify the proposed approach.

유압식 자동차 동력조향장치 실내소음에 고압호스가 미치는 영향의 주파수 분석을 통한 연구 (A Study on Influence of High Pressure Hose On Automotive Power Steering Interior Noise Using frequency Analysis)

  • 전승경;신재윤;황호준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.51-56
    • /
    • 2002
  • High pressure hose having tuning cables, called 'Resonator hose' is frequently used to attenuate pressure ripple generated by the pump for reducing the vehicle interior noise. A number of studies have been conducted on the resonator hose and its analytical models. However, there are few studies which deal with the influence of resonator hose on vehicle interior noise because the most of studies focused on transmission loss of the resonator hose. This paper presents NVH test results of power steering system and frequency analysis results. In the frequency analysis, both the relations between vibration, pressure ripple and vehicle interior noise and also the design parameters of high pressure hose influencing on vehicle interior noise were discussed. The test was done for various high pressure hose specimens in full turn condition.

  • PDF

유압식 자동차 동력조향장치 고압호스가 실내소음에로 미치는 영향의 주파수 분석을 통한 연구 (A Study on Influence of High Pressure Hose on Automotive Power Steering Interior Noise Using Frequency Analysis)

  • 전승경;신재윤;황호준
    • 한국소음진동공학회논문집
    • /
    • 제13권2호
    • /
    • pp.108-115
    • /
    • 2003
  • High pressure hose having tuning cables, called Resonator hose is frequently used to attenuate pressure ripple generated by the pump for reducing the vehicle interior noise. A number of studios have been conducted on the resonator hose and its analytical models. However, there are few studies which deal with the influence of resonator hose on vehicle interior noise because the most of studies were focused on transmission loss of the resonator hose. This paper presents NVH test results of power steering system and frequency analysis results. In the frequency analysis, both the relations between vibration, pressure ripple and vehicle interior noise and also the design parameters of high pressure hose influencing on vehicle Interior noise were discussed. The test was done for various high pressure hose specimens in full turn condition.

하이브리드 샤프트 설계 파라미터 변화에 따른 특성 연구 (A Study on Characteristics According to the Parameter Variation for Hybrid Shaft Design)

  • 홍용;김현식;홍동표
    • 한국소음진동공학회논문집
    • /
    • 제19권3호
    • /
    • pp.274-281
    • /
    • 2009
  • The carbon fiber epoxy composite material and aluminum have many advantages over other materials because of their high specific stiffness and good fatigue characteristics. Basically, the propeller shaft of automobile requires bending frequency of higher than 2,700 Nm and high natural frequency of higher than 9,200 rpm occurred by fast revolution. For this reason, natural frequency and torsion torque characteristics of hybrid shaft was studied in variation of its outer-diameter and thickness. Vibration and torque characteristics of hybrid shaft were compared by torsion tester, natural frequency experiments and FE analysis. Designed hybrid shaft satisfied its vibration and torque characteristics when its outer-diameter was 60 mm and thickness was 5 mm. Therefore, hybrid material enables to manufacture one piece structure hybrid propeller shaft rather than current two piece structure.

초고주파 진동항타기의 구동 성능향상을 위한 파라미터 설계 및 항타진동의 전달과 감쇠특성에 관한 연구 (The Design of Parameters to Improve Actuating Performance in High Frequency Vibro-Hammer(HFVH) and the Study of Characteristic Propagation and Attenuation of Piling Vibration)

  • 장태인;박준혁;백윤수;김성배
    • 대한기계학회논문집A
    • /
    • 제28권6호
    • /
    • pp.763-773
    • /
    • 2004
  • This paper suggests the 2 D.O.F mathematical model of the High Frequency Vibro-Hammer (HFVH), introduces an experimental method for measuring of the attenuation of piling vibration and proves what experiments are coincident with the equation of wave propagation. As vibratory installation of piles and casings has many economic merits in the construction field, most of all contractors prefer to vibratory pile driving method than the other. Compared to impact pile driving, vibratory installation has the advantage of reducing vibration or noise pollution and can drive piles under high frequency. Experiments serve estimations of capabilities and limitations of the HFVH's excitation force and finding of sensitivity for important soil resistance parameters. Also, we discuss the HFVH that can drive with three kinds of input waves (triangular, sine and square wave) and propose the design of parameters to improve actuating performance in it.

시간-주파수 분석을 이용한 고속철도차량 윤축에서 발생하는 소음과 진동의 동적 특성 (Dynamic Characteristics of the Noise and Vibration of High-speed Train's Wheelset using Time-varying Frequency Analysis)

  • 이준석;최성훈;김상수;박춘수
    • 한국철도학회논문집
    • /
    • 제12권4호
    • /
    • pp.465-471
    • /
    • 2009
  • 본 논분에서는 보다 적은 실험으로 고속철도차량의 윤축에서 발생하는 소음과 진동의 동적 특성을 알기 위해 불규칙 신호처리와 시간-주파수 해석을 이용하여 분석하였다. 윤축의 소음과 진동은 대부분 차륜과 궤도의 비정상상호작용이 원인이다. 이를 분석하기 위해 마이크로폰과 가속도계를 이용하여 데이터를 수집하고 붙규칙 신호처리와 시간-주파수 분석을 이용하여 분석하였다. 분석한 결과, 이 방법들은 고속철도차량의 윤축에서 발생하는 소음과 진동의 동적특성을 분석하는데 유용함을 확인하였다.

고압 LNG 펌프의 이상 진동 진단 (Abnormal Vibration Diagnosis of High Pressure LNG Pump)

  • 김학은;최병근
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.45-49
    • /
    • 2005
  • Liquefied natural gas takes up six hundredths of the volume of natural gas, which makes storage and transportation much easier. To send out natural gas via a pipeline network across the nation, high-pressure LNG pumps supply highly compressed LNG to high-pressure vaporization facilities. The Number of high-pressure LNG pumps determined the send-out amount in LNG receiving terminal. So it is main equipment at LNG production process and should be maintained on best conditions. In this paper, to find out the cause of high beat vibration at cryogenic pumps, vibration and motor current signal analysis have been performed. High vibration of cryogenic pumps could be reduced due to the modification of motor rotor.

  • PDF

MR 유체와 압전스택을 특징으로하는 새로운 형태의 능동 엔진마운트 시스템 (A New Type of Active Engine Mount System Featuring MR Fluid and Piezostack)

  • 이동영;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.444-449
    • /
    • 2009
  • An engine is one of the most dominant noise and vibration sources in vehicle systems. Therefore, in order to resolve noise and vibration problems due to engine, various types of engine mounts have been proposed. This work presents a new type of active engine mount system featuring a magneto-rheological (MR) fluid and a piezostack actuator. As a first step, six degrees-of freedom dynamic model of an in-line four-cylinder engine which has three points mounting system is derived by considering the dynamic behaviors of MR mount and piezostack mount. In the configuration of engine mount system, two MR mounts are installed for vibration control of roll mode motion whose energy is very high in low frequency range, while one piezostack mount is installed for vibration control of bounce and pitch mode motion whose energy is relatively high in high frequency range. As a second step, linear quadratic regulator (LQR) controller is synthesized to actively control the imposed vibration. In order to demonstrate the effectiveness of the proposed active engine mount, vibration control performances are evaluated under various engine operating speeds (wide frequency range) and presented in time domain.

  • PDF