• 제목/요약/키워드: High efficiency operation

검색결과 1,907건 처리시간 0.03초

A 2.4 GHz-Band 100 W GaN-HEMT High-Efficiency Power Amplifier for Microwave Heating

  • Nakatani, Keigo;Ishizaki, Toshio
    • Journal of electromagnetic engineering and science
    • /
    • 제15권2호
    • /
    • pp.82-88
    • /
    • 2015
  • The magnetron, a vacuum tube, is currently the usual high-power microwave power source used for microwave heating. However, the oscillating frequency and output power are unstable and noisy due to the low quality of the high-voltage power supply and low Q of the oscillation circuit. A heating system with enhanced reliability and the capability for control of chemical reactions is desired, because microwave absorption efficiency differs greatly depending on the object being heated. Recent studies on microwave high-efficiency power amplifiers have used harmonic processing techniques, such as class-F and inverse class-F. The present study describes a high-efficiency 100 W GaN-HEMT amplifier that uses a harmonic processing technique that shapes the current and voltage waveforms to improve efficiency. The fabricated GaN power amplifier obtained an output power of 50.4 dBm, a drain efficiency of 72.9%, and a power added efficiency (PAE) of 64.0% at 2.45 GHz for continuous wave operation. A prototype microwave heating system was also developed using this GaN power amplifier. Microwaves totaling 400 W are fed from patch antennas mounted on the top and bottom of the microwave chamber. Preliminary heating experiments with this system have just been initiated.

농업용 보의 수차 발전기 효율 분석 (Efficiency Analysis for Water Turbine Generator of Agricultural Reservoir)

  • 김종겸
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1223-1227
    • /
    • 2013
  • If the factory test efficiency and field operation efficiency of water turbine are different from each other, issues for efficiency warranty can be raised. So, This paper shows the result for comparative analysis of field operating efficiency vs plant testing efficiency of the water turbine generator installed in agricultural reservoir. The efficiency of the induction generator is analyzed by the change of rotational speed with the parameter obtained by test, the efficiency of water turbine is calculated by the change of head with the design flow. Efficiency deviation of induction generator is lower but the variation of developed power is pretty high near the rated speed and the efficiency variation of water turbine is high by the fluctuation of head for constant flow. It was found that factory test efficiency and total efficiency of water turbine generator calculated according to the rotational speed are very close.

동기 리럭턴스 전동기의 에너지 절감을 위한 효율 최적화 제어 (Efficiency Optimization Control for Energy Saving of Synchronous Reluctance Motor)

  • 이정철;이흥균;정동화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.159-162
    • /
    • 2001
  • This paper is proposed an efficiency optimization operation algorithm for synchronous reluctance motor (SynRM) using current phase angle control technique. The SynRM has to controlled with the optimal current phase angles with load and operation speed variation, to obtain high efficiency over the wide speed ranges. An efficiency optimization condition in SynRM which minimizes the copper and iron losses is derived based on the equivalent circuit model of the machine. The objective of the efficiency optimization control algorithm compensating the optimum current angle, is to seek a combination of d and q-axis current components which provides minimum losses at a certain operating point in steady state. The usefulness of the proposed efficiency optimization control is verified through vector-controlled inverter system with the SynRM.

  • PDF

A Novel Efficiency Optimization Strategy of IPMSM for Pump Applications

  • Zhou, Guangxu;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.515-520
    • /
    • 2009
  • According to the operating characteristics of pump applications, they should exhibit high efficiency and energy saving capabilities throughout the whole operating process. A novel efficiency optimization control strategy is presented here to meet the high efficiency demand of a variable speed Permanent Magnet Synchronous Motor (PMSM). The core of this strategy is the excellent integration of mended maximum torque to the current control algorithm, based on the losses model during the dynamic and the grade search method with changed step by fuzzy logic during the steady. The performance experiments for the control system of a variable speed high efficiency PMSM have been completed. The test results verified that the system can reliably operate with a different control strategy during dynamic and steady operation, and the system exhibits better performance when using the efficiency-optimization control.

Analysis, Design, Modeling, Simulation and Development of Single-Switch AC-DC Converters for Power Factor and Efficiency Improvement

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.51-59
    • /
    • 2008
  • This paper addresses several issues concerning the analysis, design, modeling, simulation and development of single-phase, single-switch, power factor corrected AC-DC high frequency switching converter topologies with transformer isolation. A detailed analysis and design is presented for single-switch topologies, namely forward buck, flyback, Cuk, Sepic and Zeta buck-boost converters, with high frequency isolation for discontinuous conduction modes (DCM) of operation. With an awareness of modem design trends towards improved performance, these switching converters are designed for low power rating and low output voltage, typically 20.25W with 13.5V in DCM operation. Laboratory prototypes of the proposed single-switch converters in DCM operation are developed and test results are presented to validate the proposed design and developed model of the system.

복합화력 발전용 재열사이클 가스터빈의 운전상태 분석 (Analysis of Operation Conditions of a Reheat Cycle Gas Turbine for a Combined Cycle Power Plant)

  • 윤수형;정대환;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제9권6호
    • /
    • pp.35-44
    • /
    • 2006
  • Operation conditions of a reheat cycle gas turbine for a combined cycle power plant was analyzed. Based on measured performance parameters of the gas turbine, a performance analysis program predicted component characteristic parameters such as compressor air flow, compressor efficiency, efficiencies of both the high and low pressure turbines, and coolant flows. The predicted air flow and its variation with the inlet guide vane setting were sufficiently accurate. The compressor running characteristic in terms of the relations between air flow, pressure ratio and efficiency was presented. The variations of the efficiencies of both the high and low pressure turbines were also presented. Almost constant flow functions of both turbines were predicted. The current methodology and obtained data can be utilized for performance diagnosis.

Development of Operation Strategy to improve Efficiency for Twin Automated Transfer Crane in an Automated Container Terminal

  • Park, Byung-Joo;Choi, Hyung-Rim
    • 한국항해항만학회지
    • /
    • 제31권7호
    • /
    • pp.605-611
    • /
    • 2007
  • In order to become a mega hub port, major ports all over the world are making every effort to enhance their productivity through efficiency of internal operation. Accordingly, in order to enhance the competitiveness of a container terminal, an automated container terminal is considered as the best alternative. An automated container terminal is using such automated handling equipment as AGV(Automated Guided Vehicles) and ATC(Automated Transfer Crane). The efficient equipment operation plays a critical role in enhancing the productivity of an automated container terminal. In an automated container terminal, the most important equipments are AGV and ATC. Each block of containers with a vertical layout is generally operating two ATCs. The two ATCs can be crossed or not at each block. In the case of operating crossover ATC, it has an advantage of high flexibility that ATC work is possible at both TP(Transfer Point) of each block. But it has also a disadvantage that the yard has to be operated at a low storage level of containers in the terminal yard. Recently, for automated container terminals, which are being prepared for opening in Korea, they plan to use uncrossed twin ATC in order to make the storage level of their yards high at a low cost. Therefore, studies have to be made in order to increase the efficiency of twin ATC system based on the flexibility that the crossover ATC system has. This research aims to suggest an operation strategy to improve efficiency of twin ATC at each storage block in a yard.

석탄화력 발전소 최적 변압운전 부하 범위 개선에 대한 연구 (A Study on the Improvement of Optimal Load Range for Sliding Pressure Operation of coal-fired Power Plant)

  • 이상훈;왕민석;위상봉;손영득
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.675-680
    • /
    • 2019
  • 석탄화력발전소는 저부하에서 효율 향상을 위해 변압운전으로, 고부하에서는 정압으로 운전하는 복합변압운전 방식으로 운전하고 있으며, 복합변압운전에는 2밸브 및 3밸브 전개모드로 구분되어 운영되고 있다. 각 발전소는 제작사 권고에 따라 터빈제어밸브 모드를 선택하여 운전하고 있으나 최적의 변압운전 부하범위로 운전되고 있지 않고, 각 발전소별 부하범위 또한 상이하게 구성 되어있다. 최적의 변압운전 부하범위로 설정되지 않으면 터빈밸브 교축 손실 발생에 따른 고압터빈 내부효율 저하가 발생되어 플랜트 효율이 저하된다. 이러한 문제점을 개선하기 위해 본 논문에서는 터빈제어밸브 모드별 최적의 변압운전 부하 범위를 개선하기 위해 각 부하별 열 성능 분석 방법을 통해 최적의 부하범위를 선정하고자 한다.

습식 마늘박피 시스템 개발 (IV) - 상업용 시스템의 구조와 성능 - (Development of a Garlic Peeling System Using High-Pressure Water Jets (IV) - Structure and performance of a full-scale system in operation -)

  • 배영환;양규원;백성기;김정호;장영창;이수희
    • Journal of Biosystems Engineering
    • /
    • 제30권1호
    • /
    • pp.25-31
    • /
    • 2005
  • There are more than three hundred garlic peeling facilities in Korea and most of them use pressurized air for skin peeling operation. One of the major problems of using air for the peeling operation is the occurrence of excessive bruises on the flesh of peeled garlic which causes easy microbial contamination and shortening of the shelf lift. To reduce the occurrence of bruises during the peeling operation, a new type of garlic peeling system was developed which use pressurized water. In this system, high pressure water jets were used to separate garlic bulbs and to peel the skin of garlic cloves. Six commercial systems of this type had been developed and installed at several locations in Korea. The design and performance of the latest system according to three pressure levels were described in this paper. Peeling efficiency of the system was as high as $64.7\%$ in one cycle of peeling operation by three chambers installed in series. Incorporation of a sorting system based on machine vision and re-circulation of unpeeled and partially-peeled garlic enhanced peeling efficiency by additional $30\%$, resulting in total peeling efficiency of the final products of approximately $95\%$. Peeling capacity of the system was over 400 kg per hour.

E급고효율동조전력증폭기의 동작특성에 관한 연구 (A Study on the Operation of the Class E High-Efficiency Tuned Power Amplifier)

  • 김정기
    • 한국통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.132-139
    • /
    • 1984
  • 병렬 인덕터와 직렬공진회로를 부하로 갖는 E급 동조전력 증폭기의 duty cycle변화에 따른 콜렉터 전압과 전류, 기본 주파수 성분, 부하회로소자 및 출력전력능력에 관한 방정식을 유도하여 최적동작상태의 특성을 해석하며 실제 콜렉터 포화전압을 고려하여 duty cycle이 50%일 때 증폭효율이 90%이상된다는 것을 이론과 실험을 통하여 고찰하였다.

  • PDF