• Title/Summary/Keyword: High efficiency operation

Search Result 1,907, Processing Time 0.029 seconds

An Efficiency Analysis on Mutation Operation with TSP solved in Genetic Algorithm

  • Yoon, Hoijin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.12
    • /
    • pp.55-61
    • /
    • 2020
  • Genetic Algorithm(GA) is applied to a problem that could not figure out its solution in a straightway. It is called as NP-hard problem. GA requires a high-performance system to be run on since the high-cost operations are needed such as crossover, selection, and mutation. Moreover, the scale of the problem domain is normally huge. That is why the straightway cannot be applied. To reduce the drawback of high-cost requirements, we try to answer if all the operations including mutation are necessary for all cases. In the experiment, we set up two cases of with/without mutation operations and gather the number of generations and the fitness of a solution. The subject in the experiment is Travelling Salesman Problem(TSP), which is one of the popular problems solved by GA. As a result, the cases with mutation operation are not faster and the solution is fitter than the case with mutation operation. From the result, the conclusion is that mutation operation does not always need for a better solution in a faster way.

Development of 50W Solid Oxide Fuel Cell system (50W 고체 산화물 연료전지 시스템 구축)

  • Jee, Young-Seok;Lah, Se-Yun;Cho, Goo-Young;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.311-314
    • /
    • 2009
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells, We evaluated hydrogen fed SOFC 50W system theoretically and got the results about the operating condition range from the comparison of the power efficiency, exhaust gas temperature, required heat for maintaining the operation temperature and operation time.

  • PDF

A Study on the Parallel Operation Strategy of Small Wind Turbine System for Battery Charging (배터리 충전을 위한 소형풍력 발전 시스템의 병렬 운전방안에 관한 연구)

  • Son, Yung-Deug;Ku, Hyun-Keun;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.549-556
    • /
    • 2014
  • This study proposes a parallel operation strategy for small wind turbine systems. A small wind turbine system consists of blade, permanent magnet synchronous generator, three-phase diode rectifier, DC/DC buck converter, and the battery load. This configuration has reliability, simple control algorithm, high efficiency, and low cost. In spite of these advantages, the system stops when unexpected failures occur. Possible failures can be divided into mechanical and electrical parts. The proposed strategy focuses on the failure of electrical parts, which is verified by numerical analysis through equivalent circuit and acquired general formula of small wind power generation systems. Simulation and experimental results prove its efficiency and usefulness.

A Study on Evaluation of corrective maintenance for the ATP on-board equipped in Tilting train (틸팅열차 차상신호장치 교정유지보수 평가에 관한 연구)

  • Lee, Kang-Mi;Shin, Duc-Ko;Baek, Jong-Hyen;Lee, Jae-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1989-1992
    • /
    • 2009
  • Maintenance is classified preventive maintenance before performing equipment failure and corrective maintenance after performing equipment failure. In preventive maintenance, we may analyze the failure data to end from beginning of equipment and allocate maintenance method and calculate maintenance cycle quantitatively by the failure data analysis. So, it has a merit to reduce system maintenance cost and to operate effectively but, it require high cost in system introducing and continuous operation to end of system. In corrective maintenance, we may calculate MTTR(mean time to repair) quantitatively based on function failure time. it can be based on establishing maintenance system for operation efficiency. In this paper, we may reflect the MTTR for the onboard equipped in Tilting train to establish maintenance system for Tilting train operation efficiency.

  • PDF

A comparison of steam turbine control systems according to adoption of turbine bypass system (바이패스 시스템 체용 유무에 따른 증기 터빈제어 비교)

  • Choi, I.K.;Kim, J.A.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2342-2344
    • /
    • 2000
  • Many years ago, most of thermal power plants built in this country were of subcritical pressure, of medium or small size, of constant pressure operation, of drum type steam generator. But, nowadays, almost all of them were of high efficiency, of supercritical pressure, of great capacity(about 500MW), of sliding pressure operation, of once through type steam generator. Presently built once through boiler introduces turbine bypass systems to variable pressure operation which eliminates unexpected materials in boiler tube during startup, minimizes fuel loss by short startup period, eventually improves total efficiency and power system stability

  • PDF

Novel Hybrid Converter for the On-Board Charger of Electric Vehicle (전기자동차용 온보드 충전기를 위한 새로운 하이브리드 컨버터)

  • Vu, Hai-Nam;Tran, Dai-Duong;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.52-53
    • /
    • 2015
  • This paper introduces a novel hybrid converter combining a full-bridge soft switching converter and a full-bridge LLC converter. In this topology all the primary switches can achieve ZVS and ZCS all over the operation range. An additional switch and a diode are added in the secondary side of full-bridge converter to eliminate the circulating current and to provide a separate freewheeling path. The hybrid structure makes it possible to deliver the power to the secondary all the time of operation, thereby improving the efficiency. The proposed topology is suitable for the applications such as on-board chargers for electric vehicles and high power dc-dc converters. A 6.6-kW prototype converter was implemented and 97.5% efficiency was obtained through the experiments.

  • PDF

A Study on Improvement of Sewage Treatment System (오염처리장의 처리효율 개선연구)

  • 성일화
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.36-40
    • /
    • 1993
  • The objective of this research was to retrofit an on-site sewage treatment system suitable to current situation of Korea to reduce the pollution loading and preserve the invaluable water resources. Operation at the F/M ratio of 0.1 kg. BOD/kg MLSS day showed 87.1% BOD removal efficiency and 84.5% COD removal efficiency, and its effluent concentration was 6.4 mg/l as BOD and 21.7 mg/l as COD. Average removal of total nitrogen showed high removal efficiency of 80%.

  • PDF

Simulator of Automatic Power Switching System (절연구간 자동절체 통과 현상 규명용 모의시뮬레이터 제작)

  • Han, Moon-Seob;Shin, Hyo-Bum;Jang, Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.918-923
    • /
    • 2011
  • On AC railway systems, the neutral sections are installed in front of substations and sectioning posts in order to avoid crash between power that have differing phases. In case railway vehicles pass through these neutral sections, it is necessary for them to switch to coasting driving by notch-off. This may reduce speed of the vehicles, resulting lowered train operation efficiency. The usage of automatic power switching systems makes it possible to pass neutral sections at notch-on, enhancing operation efficiency so that it is appropriate for high-speed railway applications. This paper introduces a simulator that assesses efficiency of automatic power switching systems in neutral sections. The is composed of a power supply system, electric railway vehicles, thyristor switches, and traction motors.

  • PDF

Improved Efficiency Methodology of 100kW-Energy Storage System with Wide-Voltage Range for DC Distribution (직류배전을 위한 넓은 전압범위를 가지는 100kW급 에너지저장장치의 고효율화 방안연구)

  • Byen, Byeng-Joo;Jeong, Byong-Hwan;Kim, Jea-Han;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.44-52
    • /
    • 2017
  • This paper describes a 100 kW high-efficiency isolated DC-DC converter for DC distribution system. The DC-DC converter consists of two dual-active-bridge (DAB) converters in parallel. The operating principle of the DAB converter is explained, and the algorithm for parallel operation of the DAB converters is proposed. Simulation and experiments are conducted to verify the performance of the proposed system. Experimental results demonstrate that the developed converter excellently marks 97.4 percent of peak efficiency under its normal operating condition.