• 제목/요약/키워드: High current measuring

검색결과 478건 처리시간 0.025초

Flexible Rogowski 코일을 이용한 클램프형 전류 센서의 개발 (Development of Clamp Current Meter using a Flexible Rogowski Coil)

  • 장용무;김성일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.472-475
    • /
    • 2002
  • A Rogowski coil can measure alternating currents from a few amps to over 1 million amps in a frequency range from less than 0.1 Hz to about lMhz. A Rogowski coil provides an induced output voltage which is proportional to the rate of change of the primary current enclosed by the flexible or the rigid coil-loop. Therefore, it is necessary to integrate the output voltage in order to produce a voltage proportional to the current. Also. it can reproduce the current waveform on an oscilloscope or any type of data acquisition device. This paper describes the practical design of the combination of a Rogowski coil and an integrator which provides a versatile current measuring system to accommodate a wide range of frequencies, current levels and conductor sizes.

  • PDF

한국형 고속전철용 판토그라프의 거동 특성과 열차속도와의 상관관계와 경향 (Relation and Variation Trend between the Behavior of the Pantograph vs. the Vehicle Running Speed in Korean High Speed Train)

  • 목진용;박춘수;조용현;최강윤;김기환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.170-176
    • /
    • 2003
  • The pantograph for Korean High Speed Train was developed and had been evaluating by through "G7- R&D for home grown high speed train technology". In this study, a relation in mechanical aspect between the train running speed and the current collecting performance of the pantograph is conducted.'for this study, a measuring system for current collecting performance and mechanical characteristics is developed and installed on the prototype Korean High Speed Train, and measurement is conducted while the train runs on the test track. The measuring system is composed of video monitoring system and telemetry & data processing unit. It monitors whether the hazard behavior in the pantograph is occurs or not, and measures acceleration and vertical contact force between the pan head and catenary. Through this study, evaluation of a mechanical vibration characteristics and trend of the pantograph and a interface performance of pantograph - catenary up to 200㎞/h train speed are facilitated.

  • PDF

부싱형 커패시터를 이용한 고전압 계측시스템에 관한 연구 (A study on high-voltage measuring system using bushing-type capacitor)

  • 강문성;심형관;유충현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.502-507
    • /
    • 1999
  • An improved, accurate and reliable high-voltage measuring system utilizing a bushing-type capacitor is proposed in this study. This system measures voltages and phase angles of three-phase 22.9 kV power distribution lines and provides enough current to charge a battery for a motor-driven load switch and to operate the measuring and communication circuits for the distribution automation. For reliability, epoxy resin was used as the dielectric material of the bushing-type capacitor since the dielectric strength of epoxy resin is very stable over the wide range of temperature. Capacitances were investigated and found to be stable over the wide range of temperature and applied voltage, and the results indicate that the proposed measurement system is very reliable.

  • PDF

낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작 (Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection)

  • 길형준;송길목;김영석;김종민;김영진
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

궤도회로 모델링을 이용한 KTX 궤도결함 진단 프로그램 개발 (Development of KTX Track Error Diagnosis Program using Track Circuit Modeling Methods)

  • 안동준;이병곤;남현도
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.44-51
    • /
    • 2012
  • The purpose of this study is development of the diagnosis system to preventative maintenance in the on-board measuring systems for in-cab electric inspection systems of high speed railway. The on-board measuring systems can inspect precisely whether ground signal system operate stably. In this paper, we recognize characteristics of the track circuits and confirm whether the wave of current matches the on-board measuring data through the electric modeling method for high speed railway. it is necessary to develop GUI visual programs that can simulate abnormalities of the on-board measuring data in many ways, and the visual program is designed to diagnosis in the case of track circuit equipment's function decreased in advance.

PBLG와 PBDG의 자격 응답특성에 관한 연구 (A Study on Stimulus Response Characteristic of PBLG and PBDG)

  • 김병근;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.47-50
    • /
    • 2002
  • The displacemant current measuring system used for detecting the dynamic behavior of monolayers at the air-water interface is described. It basically consists of a film balance, a pair of electrodes connected to each other through a sensitive ammeter. Here, one electrode is suspended in air and the other electrode is placed in the water. With Maxwell-displacement-current-measuring method, the phase transitons of $Poly-{\gamma}-benzyl_{L}$ -glutamate (PBLG) and $Poly-{\gamma}-benzyl_{D}$-glutamate(PBDG) on a water surface were detected. Measured surface pressure, displacement current and dipole moment of monolayers of PBLG and PBDG on the water surface. Also, we measured that compression velocity (30, 40, 50[mm/min]) when the sample spread volume was about 370[ul]-400[ul] and displacement current that occur when differed temperature. From the result, it is known that current is generated in the range of high surface pressures as compression velocity become faster and increase of temperature.

  • PDF

넓은 대역폭과 고안정도를 가진 교류, 직류 전류 측정용 영자속 전류 측정기 (Zero-Flux Current Transformer, High stability and Wide Band Measuring For AC and DC Current.)

  • 서재학;남상훈;고인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2045-2047
    • /
    • 1998
  • To store and maintain electron beams in synchrotron machines, it is very important to read and keep precise magnet current ($<{\pm}50$ ppm). However, accurate DC current measurement tools are not readily available. In this paper, we introduce high precision, wide band zero-flux current transformer that is manufactured and tested at Pohang Accelerator Laboratory. This sensor can measure DC as well as AC current. Accuracy of the current transformer is less than ${\pm}$20 ppm. Performance of the manufactured current sensor is compared with a high precision DCCT which is commercially available sensor.

  • PDF

고성능 필터를 이용한 접지저항 측정시스템의 설계 (Design of the Ground Resistance Measuring System using high Performance Filter System)

  • 이기홍;정재기;주형준
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.43-48
    • /
    • 2001
  • 본 논문에서는 지중의 노이즈들로부터 영향을 받지않는 접지저항 측정시스템을 설계하였다. 일반적으로 기존 의 접지저항 측정기는 지중에 노이즈가 잠재되어 있을 경우, 접지저항 측정신호가 영향을 받아 정확한 접지저항을 측정하기 어렵다. 따라서 본 논문에서는 L-C공진필터와 마이크로프로세서를 이용하여 지중의 잡음환경에서도 정확히 접지저항을 측정할 수 있는 접지저항 측정기를 설계하였다. 또한 현장시험을 통해 설계된 접지저항측정기가 지중의 노이즈로부터 영향을 받지않음을 입증하였다.

  • PDF

고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구 (A Study on the High-Accuracy Power Meter and Reliability Verification Plan)

  • 이상훈;이창화
    • 한국멀티미디어학회논문지
    • /
    • 제20권7호
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.

적응형 가변 전원 레귤레이터를 내장한 인공 망막용 전류 자극기 (Current Stimulator with Adaptive Supply Regulator for Artificial Retina Prosthesis)

  • 고형호
    • 센서학회지
    • /
    • 제20권4호
    • /
    • pp.254-259
    • /
    • 2011
  • In this paper, a current stimulator circuit with adaptive supply regulator for retinal prosthesis is proposed. In current stimulation systems, the stimulating circuits with wide voltage swing range are needed due to the high impedance of the retina cell and microelectrodes. Thus, previous researches adopt the high voltage architecture to obtain the enough operating range. The high voltage architecture, however, could increase the power consumption and can damage the retina cells. The proposed circuit provides the adaptively regulated supply voltage by measuring the difference between desired stimulation current and the actual stimulation current. The proposed circuit can achieve the extended range of the allowable cell impedance, improved accuracy of the stimulation current, and higher biosafety.