• 제목/요약/키워드: High current measuring

검색결과 479건 처리시간 0.023초

펄스파워용 X선제어 무도체스위치의 기본연구 (A Basic Study on X-ray Controlled Semiconductor Switch for Pulse Power)

  • Ko, Kwang-Cheol
    • 대한전기학회논문지
    • /
    • 제41권9호
    • /
    • pp.1013-1020
    • /
    • 1992
  • The conductivity variation of a high resistivity bulk silicon semiconductor, whose electrodes were deposited with aluminum vapor, was studied experimentally by measuring the X-ray intensity and current flow, which was developed by X-ray radiation while applying a pulse voltage to the silicon, in a load resistor connected to the semiconductor. The current flow observed immediately as the X-ray radiated, and when the X-ray decreased. It was found from the observation of switching current for the X-ray intensity and the voltage applied in the semiconductor that the switching current of the semiconductor increased as the intensity of the X-ray and the applied voltage increased. In case of lower applied voltage, the switching current for higher applied voltage depended on the intensity of the X-ray radiated due to the saturation of electron and hole.

  • PDF

고정영역에서 M1-P-M2형 고분자재료의 단락전류 (Short-Circuit Current of Polymeric Materials with M1-P-M2 structure in High Temperature Region)

  • 이덕출;이능헌;임헌찬
    • 대한전기학회논문지
    • /
    • 제36권5호
    • /
    • pp.339-345
    • /
    • 1987
  • In the region of high temperature, a very appreciable short-circuit current Is was observed from M1(A1)-P(PET)-M2(Cu) system sandwitched with hetero metals without applying external field. The short-circuit current Is is greatly dependent on electrode material and it has been certified by measuring open-circuit voltage. From these experimental results, we can see that Is is due to electro-chemical action in M-P interface. In this electro-chemical reaction,the generation reaction and the solution reacftion of the oxidies from electrode are probably co-exist and the measured values of the open-circuit voltage was almost correspond to those calculated from Nernst equation.

  • PDF

고정자 전류벡터를 이용한 리럭턴스 동기전동기의 직접토크제어 (A Direct Torque Control of Reluctance Synchronous Motor with Stator Current Space Vector)

  • 김남훈;김민회;백원식;김동희;황돈하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.293-296
    • /
    • 2002
  • This paper presents an implementation of Direct torque control(DTC) of Reluctance Synchronous Motor(RSM) drives for an industrial servo drive system with stator current space vector. The estimation of the stator flux magnitude are obtained by using the neural network from measuring the modulus and angle of the stator current space vector. The develolled digitally high-performance control system are shown a good response characteristic of control results and high performance features using 1.0kW RSM.

  • PDF

Power Closed-loop Control of Switched Reluctance Generator for High Efficiency Operation

  • Li, Zhenguo;Gao, Dongdong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.397-403
    • /
    • 2012
  • This paper describes a control method of turn-on/off angles to improve the efficiency of the switched reluctance generator(SRG) with a power closed-loop control system, and the inner-loop of the system is current hysteresis control. The SRG control system is constituted by the PI power controller and the two-level current hysteresis controller. By measuring and analyzing the system losses of different reference powers, speeds and turn-on/off angles, selection strategy of optimal turn-on/off angles is discussed. The proposed method is simple, reliable, and easy to achieve.

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • 제15권1호
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.

직접토크제어에 의한 리럭턴스 동기전동기의 고성능 제어시스템 (A High-Performance Control System of Reluctance Synchronous Motor with Direct Torque Control)

  • 김민회
    • 전기학회논문지P
    • /
    • 제51권2호
    • /
    • pp.68-76
    • /
    • 2002
  • This paper presents an implementation of high-dynamic performance control system of Reluctance Synchronous Motor (RSM) drives for an industrial servo system with direct torque control (DTC). The problems of DTC for high-dynamic performance and maximum efficiency RSM drives are the nonlinear variable flux and inductance due to a saturated stator linkage flux and nonlinear inductance curve with various load currents. The accurate estimation of the stator flux and torque are obtained using stator flux observer of which a saturated inductance Ld and Lq can be compensated by using the adapted neural network from measuring the modulus and angle of the stator current. To obtain fast torque response and maximum torque/current with varying load current, the reference command flux is ensured by imposing Ids=Iqs. This control strategy is proposed to fast response and optimal efficiency for RSM drive. In order to prove rightness of the suggested control algorithm, we have some actual experimental system using 6000 pulse/rev encoder at ${\pm}10$ and ${\pm}1500rpm$. The developed digitally high-performance control system are shown some good response characteristics of control results and high performance features using 1.0kW RSM of which has 2.57 Ld/Lq salient ratio.

발전기 변류기 건전성 확보를 위한 연구 (Activities to attain integrity of generator current transformer)

  • 조철환;조성태;양경현;안경재;이형우
    • 동력기계공학회지
    • /
    • 제16권1호
    • /
    • pp.19-23
    • /
    • 2012
  • This thesis is the result of conducting an analysis to find the solution to the phenomenon of power stoppage due to the disconnection of a CT (Current Transformer) because of vibration. The CT which measures the most essential current is used in power industries as part of a generator protection relay. When it comes to the bottom plate of a CT, nonconductor; such as bakelite and laminates; these material elements should be used because it is impossible to utilize the conductor when measuring the current of a generator which carries a high current if you use other materials. These nonconductor's material properties are irregular and interpretation errors often occur because the weight is light. In addition, since the change of dynamic characteristics which are related to the temperature often occur, it is important to match the real situation by considering an error of interpretation rather than selecting the quality of the material. Lastly, the conclusion that the study drew is that it is possible to avoid the resonance by utilizing three changes to the components to solve the problem concerning the high vibration which is caused by non-conductive objects. These changes are the most crucial points in this thesis: First, material changes to the Plate. Second, weight changes to the Coil. Third, thickness changes to the Plate.

선로고장시 발생되는 잡음의 시뮬레이션 (The Simulation of Transmission Line Fault-Induced Noise Signals.)

  • 신명철;김두웅;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.454-456
    • /
    • 1987
  • A more specialized area of transient evaluations is transmission line fault-detecting and protection system. During the first cycle or two following a power system fault, a high-speed protective relay is expected to make a decision as to the severity or location of the fault, usually based on 60 Hz information, i.e. the phase and magnitude of 60 Hz voltage or current signals. It is precisely at this time however that the signal is badly corrupted by noise, in the form of a de offset or frequencies above 50 Hz. One of several possible sources of transients in protection measuring signals is in the primary system for which protection is required in its response to the impact of short circuit fault on-set. Other sources are in the primary voltage and current transducers from which protection signals are derived, and, often of particular importance, in the interface circuits between the transducer secondaries and the comparator and measuring elements of the protection system. However, the noise signals that will be described in this paper are due to the main power system only and do not include errors due to current or voltage transducers.

  • PDF

고속선 연속정보 메시지 및 레벨 측정을 위한 차상신호 검측장치 설계 (A Design Of The Measuring System on On Board for Continuous Signal in High Speed Line)

  • 엄정규;임재식;김치조;조용기;유광균
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.757-766
    • /
    • 2005
  • A speed of a train is controlled by Automatic Train Control system and the continuous transmission system provide the speed related information in the Korean High Speed Line. The primary objective of this paper is to measure the level of continuous signal and to calculate the message of that signal. A measuring equipment is introduced and the equipment provide the base line of the level of current and the correction information of the message.

  • PDF

한국형 고속전철의 디스크 제동력 측정 방법에 관한 연구 (A Study on the Measuring Method of Disc Braking Force for HSR 350x)

  • 김석원;김영국;박태원
    • 센서학회지
    • /
    • 제13권3호
    • /
    • pp.244-251
    • /
    • 2004
  • In general, the braking system of high speed train has an important role for the safety of the train. To stop safely the train at its pre-decided position, it is necessary to combine properly the various brakes. Korean high speed train (HSR 350x) has adopted a combined electric and mechanic (friction) braking system. Electric brakes are consist of rheostatic brake, regenerative brake and eddy current brake and mechanical brakes are composed of disc brake, wheel disc brake and tread brake. In this paper, the measuring method that can take a measurement of the braking forces for disc brake and wheel disc brake has been suggested and we have verified that this method is valid through on-line test of HSR 350x.