• Title/Summary/Keyword: High contrast ratio

Search Result 535, Processing Time 0.028 seconds

Light Leakage Comparison in a Homogeneously Aligned Nematic Liquid Crystal Display Depending on an Angle between Polarizer Axis and Optic Axis of a Liquid Crystal

  • Song, I.S.;Baik, I.S.;Won, H.K.;Kim, D.S.;Soh, H.S.;Kim, W.Y.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1182-1184
    • /
    • 2004
  • We have studied contrast ratio of a homogeneously aligned nematic liquid crystal (LC) display as a function of the angle between the polarizer axis and LC director. The results show that a cell configuration in which a polarizer axis facing a light source coincides with a short LC axis has a better process margin in terms of high contrast ratio than that of the cell coinciding with a long LC axis.

  • PDF

Fabrication of a holographic reflector for reflective LCDs (반사형 LCD를 위한 홀로그래픽 반사판의 제작)

  • 우성일
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.27-31
    • /
    • 1999
  • We designed and fabricated a monocolor holographic reflector for reflective LCDs with DuPont holographic photopolymer as a holographic recording media. By recording at 514 nm as holographic operating wavelength, it was possible to get the brightest image in green color. High contrast ratio is possible due to misalignment of the images with surface reflection and we achieved on/off contrast ratio of 6:1 by applying the fabricated holographic reflector to a TN-LC cell.

  • PDF

Electro-optic Characteristics of Reflective Optically Compensated Splay Cell (반사형 Optically Compensated Splay 셀의 전기-광학 특성)

  • 송제훈;오상민;이종문;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.983-987
    • /
    • 2004
  • We have studied electro-optic characteristics of reflective optically compensated splay (R-OCS) cell. The initial configuration of this cell is in splay form such that a mid director lies parallel to the substrate and around it hybrid structure is formed symmetrically so the optically compensation effect exists. Optimized optical configurations could be achieved by using a single polarizer, a quarter-wave film and a cell with quarter-wane retardation. The optimal cell retardation is 0.34 ${\mu}$m, allowing to have large cell gap. The cell provides high contrast ratio of 80:1 at normal direction and the region with contrast ratio over 5:1 covert up to 160$^{\circ}$ horizontally and vertically at all wavelength range.

Recent Development of Optically Compensated Bend (OCB) Mode TFT-LCD

  • Wakemoto, Hirofumi;Nishiyama, Kazuhiro;Nakao, Kenji;Takimoto, Akio
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.562-566
    • /
    • 2005
  • Toshiba Matsushita Display Technology (TMD) has firstly succeeded in mass production of OCB (Optically Compensated Bend) mode liquid crystal display panels which have excellent moving picture quality almost the same as CRT. We have newly developed 32 -inch diagonal HD ($1366{\times}768\;pixels$) panels using OCB mode and low temperature p-Si TFT (LTPS) array substrates. High performance of brightness of $600cd/m^2$ and contrast ratio of 600 : 1 was obtained by using pseudo-impulse driving method to insert a black period between continuous two frames, and also by using blinking backlight method. Furthermore, moving picture response time (MPRT) 6.5ms has been obtained by optimization of black insert driving and backlight blinking, without the great sacrifices of contrast ratio and luminance.

  • PDF

Usefulness of Carbon Fiber Reinforced Plastics as a Material of Auxiliary Tool for X-ray Imaging (엑스선 촬영 시 보조도구 재료로써 탄소 섬유 강화 플라스틱의 유용성)

  • Joon-Ho Moon;Bon-Yeoul Koo
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.197-205
    • /
    • 2023
  • When taking X-rays, various auxiliary tools were used to fix a patient's exact shooting position and posture. In this study, we evaluated the usefulness of carbon fiber reinforced plastics(CFRP) 3K as a material of auxiliary tools by comparing poly methyl metha acrylate(PMMA), polycarbonate(PC), and CFRP 3K each of which has high radiolucency. X-ray radiolucencies were measured by stacking 1 mm panels of each material, and contrast to noise ratio(CNR) and signal to noise ratio(SNR) of images of each material were measured by comparing with None, which stands for images that are taken without any material. All three materials showed over 90% X-ray radiolucencies within 2 ㎜ thickness, and there was no significant difference. PC, PMMA and CFRP 3K had high CNR and SNR in order, and CFRP 3K showed the closest CNR and SNR to those of None. While taking X-rays, by using CFRP 3K material within 2 ㎜ thickness as a material of auxiliary tools, which are used to reduce re-shooting and X-ray exposure by fixing a patient's exact shooting position and posture and improve the quality of medical images, a high X-ray radiolucency of over 90% would be obtained, and the influence on the image could be minimized.

Usefulness of contrast agent involving high gadolium content for myocardial viability assessment (심근생존능검사 시 가돌리늄 함유량이 높은 조영제의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong;Kim, Tae-Hyung;Han, Man-Seok;Lee, Ju-Hee;Min, Jung-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1294-1300
    • /
    • 2013
  • The purpose of this study is to increase contrast to noise ratio(CNR) in myocardial viability test by using contrast agent which highly content gadolinium(1mmol/mL) maximizing diagnostic value. This research method that four hundred four patients were underwent the MRI scanning two hundred eighty four of them were injected commercial contrast media which have 0.5mmol/L and the rest of them were injected new contrast media(gadobutrol) which have 1mmol/mL of molarity to study the contrast difference depending on the molarity of the contrast agent signal intensities of normal ventricle and left ventricle were measured to compare and evaluate signal to noise ratio(SNR) and CNR of the images. As result, 1mmol/mL contrast agent showed higher SNR by 25.13% in myocardium and 30.74% in left ventricle. CNR was proved to be better in 1mmol/mL contrast agent by 31.29%. The results above were all statistically meaningful. Therefore, contrast agent contenting more gadolinium which was 1mmol/mL in this study, could more effectively shorten T1 relaxation time, increase the signal intensity and at the same time maximize CNR and diagnostic value. This study firstly report the usefulness of 1mmol/mL contrast agent in patients allegedly suffering cardiac diseases and it is considered to increase diagnostic value.

Research on the Technology of Alternative Continuous Wide Spectral Spatial Heterodyne Spectrometer

  • Zhang, Wenli;Tian, Fengchun;Zhao, Zhenzhen;Song, An;Zhang, Li
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.295-307
    • /
    • 2017
  • An innovative system for the alternative continuous wide spectral spatial heterodyne spectrometer (ACWS-SHS) is proposed. The relationship between the ACWS-SHS and the wide spectral spatial heterodyne spectrometer (WS-SHS) at the resolution limit, the spectral range, the grating diffraction efficiency and the interference fringes contrast ratio has been analyzed theoretically. Through the comparison of the theoretical analysis and simulation results, it is found that the two systems for the WS-SHS and the ACWS-SHS have the same resolution limit and spectral range, which are ${\delta}{\sigma}$ and ${\sigma}_{01}$, while in the ACWS-SHS system the critical diffraction efficiency of echelle grating is 68.39% and the critical contrast ratio of interference fringes is 0.4135, which is much better than the performance of the WS-SHS system. Therefore, the ACWS-SHS reduces the high requirements for the precision of equipment and expands the application field of SHS effectively.

Radiographic Evaluation of Small Intestinal Diameter in Small Breed Dogs (소형견에서 소장 직경의 방사선학적 평가)

  • Choi, Ho-Jung;Kim, Soo-Chan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.301-305
    • /
    • 2012
  • The purpose of the present study was to prove our empirical tendency of relatively high small intestinal diameter (SI) to fifth lumbar vertebral height (L5) ratio, which has been used in dogs. In this study, the ratio of SI/L5 was determined in small breed dogs weighing less than 5 kg. In addition, the effect of large volume of contrast media on the intestinal dilation was determined by performing upper gastrointestinal contrast study. Abdominal radiography and upper gastrointestinal series were performed in twelve healthy dogs weighing less than 5 kg. Small intestinal diameter (SI), fifth lumbar vertebral height (L5), and twelfth rib diameter were measured on abdominal radiographs. The range of values of SI/L5 is from 1.03 to 2.26 in plain radiography, and from 1.55 to 2.5 in contrast studies. Contrast agent significantly increased small intestinal diameter, and could be considered as mildly dilated intestinal model. Therefore, a value of 2.1 for SI/L5 is recommended as the upper limit of the normal range suggesting nonobstructive intestinal dilation.

Radiographic Evaluation of Small Intestinal Diameter in Small Breed Dogs (소형견에서 소장 직경의 방사선학적 평가)

  • Choi, Ho-Jung;Kim, Soo-Chan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.391-394
    • /
    • 2012
  • The purpose of the present study was to prove our empirical tendency of relatively high small intestinal diameter (SI) to fifth lumbar vertebral height (L5) ratio, which has been used in dogs. In this study, the ratio of SI/L5 was determined in small breed dogs weighing less than 5 kg. In addition, the effect of large volume of contrast media on the intestinal dilation was determined by performing upper gastrointestinal contrast study. Abdominal radiography and upper gastrointestinal series were performed in twelve healthy dogs weighing less than 5 kg. Small intestinal diameter (SI), fifth lumbar vertebral height (L5), and twelveth rib diameter were measured on abdominal radiographs. The range of values of SI/L5 is from 1.03 to 2.26 in plain radiography, and from 1.55 to 2.5 in contrast studies. Contrast agent significantly increased small intestinal diameter, and could be considered as mildly dilated intestinal model. Therefore, a value of 2.1 for SI/L5 is recommended as the upper limit of the normal range suggesting nonobstructive intestinal dilation.

Development of High Aperture Ratio 2.1” QVGA LTPS (Low Temperature Poly Si) LCD Using SLS (Sequential Lateral Solidification) Technology

  • Kang, Myung-Koo;Lee, Joong-Sun;Park, Jong-Hwa;Zhang, Lintao;Joo, Seung-Yong;Kim, Chul-Ho;Kim, Il-Kon;Kim, Sung-Ho;Park, Kyung-Soon;Yoo, Chun-Ki;Kim, Chi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1033-1034
    • /
    • 2005
  • High resolution 2.1” QVGA LTPS LCD (190ppi) having high aperture ratio of 65% could be successfully developed using state-of-the-art SLS technology and active/gate storage structure. Cost effective P-MOS 6-Mask structure was used. Full gate and transmission gate circuits are integrated in the panel. The high aperture ratio was obtained by using active/gate capacitance structure, which can reduce storage capacitance area. The aperture ratio was increased to 65% from 49% of conventional gate/data capacitance structure. The brightness was increased from 180cd to 270cd without any degradation of optical properties such as contrast ratio, flicker or crosstalk.

  • PDF