• Title/Summary/Keyword: High beam

Search Result 4,209, Processing Time 0.04 seconds

Characteristics of MHEMT Devices Having T-Shaped Gate Structure for W-Band MMIC (W-Band MMIC를 위한 T-형태 게이트 구조를 갖는 MHMET 소자 특성)

  • Lee, Jong-Min;Min, Byoung-Gue;Chang, Sung-Jae;Chang, Woo-Jin;Yoon, Hyung Sup;Jung, Hyun-Wook;Kim, Seong-Il;Kang, Dong Min;Kim, Wansik;Jung, Jooyong;Kim, Jongpil;Seo, Mihui;Kim, Sosu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.2
    • /
    • pp.99-104
    • /
    • 2020
  • In this study, we fabricated a metamorphic high-electron-mobility transistor (mHEMT) device with a T-type gate structure for the implementation of W-band monolithic microwave integrated circuits (MMICs) and investigated its characteristics. To fabricate the mHEMT device, a recess process for etching of its Schottky layer was applied before gate metal deposition, and an e-beam lithography using a triple photoresist film for the T-gate structure was employed. We measured DC and RF characteristics of the fabricated device to verify the characteristics that can be used in W-band MMIC design. The mHEMT device exhibited DC characteristics such as a drain current density of 747 mA/mm, maximum transconductance of 1.354 S/mm, and pinch-off voltage of -0.42 V. Concerning the frequency characteristics, the device showed a cutoff frequency of 215 GHz and maximum oscillation frequency of 260 GHz, which provide sufficient performance for W-band MMIC design and fabrication. In addition, active and passive modeling was performed and its accuracy was evaluated by comparing the measured results. The developed mHEMT and device models could be used for the fabrication of W-band MMICs.

Study on Concrete Activation Reduction in a PET Cyclotron Vault

  • Bakhtiari, Mahdi;Oranj, Leila Mokhtari;Jung, Nam-Suk;Lee, Arim;Lee, Hee-Seock
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.130-141
    • /
    • 2020
  • Background: Concrete activation in cyclotron vaults is a major concern associated with their decommissioning because a considerable amount of activated concrete is generated by secondary neutrons during the operation of cyclotrons. Reducing the amount of activated concrete is important because of the high cost associated with radioactive waste management. This study aims to investigate the capability of the neutron absorbing materials to reduce concrete activation. Materials and Methods: The Particle and Heavy Ion Transport code System (PHITS) code was used to simulate a cyclotron target and room. The dimensions of the room were 457 cm (length), 470 cm (width), and 320 cm (height). Gd2O3, B4C, polyethylene (PE), and borated (5 wt% natB) PE with thicknesses of 5, 10, and 15 cm and their different combinations were selected as neutron absorbing materials. They were placed on the concrete walls to determine their effects on thermal neutrons. Thin B4C and Gd2O3 were placed between the concrete wall and additional PE shield separately to decrease the required thickness of the additional shield, and the thermal neutron flux at certain depths inside the concrete was calculated for each condition. Subsequently, the optimum combination was determined with respect to radioactive waste reduction, price, and availability, and the total reduced radioactive concrete waste was estimated. Results and Discussion: In the specific conditions considered in this study, the front wall with respect to the proton beam contained radioactive waste with a depth of up to 64 cm without any additional shield. A single layer of additional shield was inefficient because a thick shield was required. Two-layer combinations comprising 0.1- or 0.4-cm-thick B4C or Gd2O3 behind 10 cm-thick PE were studied to verify whether the appropriate thickness of the additional shield could be maintained. The number of transmitted thermal neutrons reduced to 30% in case of 0.1 cm-thick Gd2O3+10 cm-thick PE or 0.1 cm-thick B4C+10 cm-thick PE. Thus, the thickness of the radioactive waste in the front wall was reduced from 64 to 48 cm. Conclusion: Based on price and availability, the combination of the 10 cm-thick PE+0.1 cmthick B4C was reasonable and could effectively reduce the number of thermal neutrons. The amount of radioactive concrete waste was reduced by factor of two when considering whole concrete walls of the PET cyclotron vault.

Impact of Treatment Time on Chemoradiotherapy in Locally Advanced Cervical Carcinoma

  • Pathy, Sushmita;Kumar, Lalit;Pandey, Ravindra Mohan;Upadhyay, Ashish;Roy, Soumyajit;Dadhwal, Vatsla;Madan, Renu;Chander, Subhash
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5075-5079
    • /
    • 2015
  • Background: Adverse effects of treatment prolongation beyond 8 weeks with radiotherapy for cervical cancer have been established. Clinical data also show that cisplatin increases the biologically effective dose of radiotherapy. However, there are no data on the effect of overall treatment time in patients with locally advanced cervical cancer treated with concomitant chemo-radiotherapy (CCRT) in an Indian population. The present study concerned the feasibility of concurrent chemotherapy and interspacing brachytherapy during the course of external radiotherapy to reduce the overall treatment time and compare the normal tissue toxicity and loco-regional control with a conventional schedule. Materials and Methods: Between January 2009 and March 2012 fifty patients registered in the Gynaecologic Oncology Clinic of Institute Rotary Cancer Hospital with locally advanced cervical cancer (FIGO stage IIB-IIIB) were enrolled. The patients were randomly allocated to treatment arms based on a computer generated random number. Arm I (n=25) treatment consisted of irradiation of the whole pelvis to a dose of 50 Gy in 27 fractions, and weekly cisplatin $40mg/m^2$. High dose rate intra-cavitary brachytherapy (HDR-ICBT) was performed after one week of completion of external beam radiotherapy (EBRT). The prescribed dose for each session was 7Gy to point A for three insertions at one week intervals. Arm II (n=25) treatment consisted of irradiation of the whole pelvis to a dose of 50 Gy in 27 fractions. Mention HDR-ICBT ICRT was performed after 40Gy and 7Gy was delivered to point A for three insertions (days 23, 30, 37) at one week intervals. Cisplatin $20mg/m^2/day$ was administered from D1-5 and D24-28. Overall treatment time was taken from first day of EBRT to last day of HDR brachytherapy. The overall loco-regional response rate (ORR) was determined at 3 and 6 months. Results: A total of 46 patients completed the planned treatment. The overall treatment times in arm I and arm II were $65{\pm}12$ and $48{\pm}4$ days, respectively (p=0.001). At three and six months of follow-up the ORR for arm I was 96% while that for arm II was 88%. No statistically significant difference was apparent between the two arms. The overall rate of grade ${\geq}3$ toxicity was numerically higher in arm I (n=7) than in arm II (n=4) though statistical significance was not reached. None of the predefined prognostic factors like age, performance status, baseline haemoglobin level, tumour size, lymph node involvement, stage or histopathological subtype showed any impact on outcome. Conclusions: In the setting of concurrent chemoradiotherapy a shorter treatment schedule of 48 days may be feasible by interspacing brachytherapy during external irradiation. The response rates and toxicities were comparable.

Comparisons between the KKU-Model and Conventional Rectal Tubes as Markers for Checking Rectal Doses during Intracavitary Brachytherapy of Cervical Cancer

  • Padoongcharoen, Prawat;Krusun, Srichai;Palusuk, Voranipit;Pesee, Montien;Supaadirek, Chunsri;Thamronganantasakul, Komsan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6115-6120
    • /
    • 2014
  • Background: To compare the KKU-model rectal tube (KKU-tube) and the conventional rectal tube (CRT) for checking rectal doses during high-dose-rate intracavitary brachytherapy (HDR-ICBT) of cervical cancer. Materials and Methods: Between February 2010 and January 2011, thirty -two patients with cervical cancer were enrolled and treated with external beam radiotherapy (EBRT) and intracavitary brachytherapy (ICBT). The KKU-tube and CRT were applied intrarectally in the same patients at alternate sessions as references for calculation of rectal doses during ICBT. The gold standard references of rectum anatomical markers which are most proximal to radiation sources were anterior rectal walls (ARW) adjacent to the uterine cervix demonstrated by barium sulfate suspension enema. The calculated rectal doses derived from actual anterior rectal walls, CRT and the anterior surfaces of the KKU-tubes were compared by using the paired t-test. The pain caused by insertion of each type of rectal tube was assessed by the visual analogue scale (VAS). Results: The mean dose of CRT was lower than the mean dose of ARW ($Dmean_0-Dmean_1$) by $80.55{\pm}47.33cGy$ (p-value <0.05). The mean dose of the KKU-tube was lower than the mean dose of ARW ($Dmean_0-Dmean_2$) by $30.82{\pm}24.20cGy$ (p-value <0.05). The mean dose difference [($Dmean_0-Dmean_1$)-($Dmean_0-Dmean_2$)] was $49.72{\pm}51.60cGy$, which was statistically significant between 42.32 cGy -57.13 cGy with the t-value of 13.24 (p-value <0.05). The maximum rectal dose by using CRT was higher than the KKU-tube as much as 75.26 cGy and statistically significant with the t-score of 7.55 (p-value <0.05). The mean doses at the anterior rectal wall while using the CRTs and the KKU-tubes were not significantly different (p-value=0.09). The mean pain score during insertion of the CRT was significantly higher than the KKU-tube by a t-score of 6.15 (p-value <0.05) Conclusions: The KKU-model rectal tube was found to be an easily producible, applicable and reliable instrument as a reference for evaluating the rectal dose during ICBT of cervical cancer without negative effects on the patients.

Fabrication of the Noninvasive Tube Voltage Meter of Radiotherapy Simulator and Its Performance Analysis (방사선치료 시뮬레이터의 비접속형관전압계 제작과 성능분석)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun;Park, Chang-Hee;Cha, Byung-Youl
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.201-206
    • /
    • 2006
  • In this study, we have fabricated the noninvasive tube voltage meter which can observe the waveform of tube voltage and measure the tube voltage by using the Intensity of X-ray beam irradiated from radiotherapy simulator and also investigated the feasibility for clinical applications. Two pin photodiodes acting as X-ray detectors were arranged in parallel at the position of ${\pm}1.4cm$ in the y-axis of X-ray field and the aluminum filters with different thickness were placed above them. Using this detector, we could get the ratio ($r_{eff}$) of the relative output voltage which is proportional to the thickness of the filters. And the logarithm of effective peak tube voltage ($InkV_{p,eff}$) was obtained by Victoreen's NERO 6000M used as reference tube voltage meter. From the linear regression analysis of $r_{eff}$ and In $kV_{p,eff}$ the correlation coefficient (r) of linear equation was obtained to be 0.996 for the calibration of the tube voltage meter. Therefore, we suggest that the noninvasive tube voltage meter fabricated in this study can be used for clinical applications due to Its high accuracy.

  • PDF

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF

Hydrogenated a-Si TFT Using Ferroelectrics (비정질실리콘 박막 트랜지스터)

  • Hur Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.576-581
    • /
    • 2005
  • In this paper. the a-Si:H TFT using ferroelectric of $SrTiO_3$ as a gate insulator is fabricated on glass. High k gate dielectric is required for on-current, threshold voltage and breakdown characteristics of TFT Dielectric characteristics of ferroelectric are superior to $SiO_2$ and $Si_3N_4$. Ferroelectric increases on-current and decreases threshold voltage of TFT and also ran improve breakdown characteristics.$SrTiO_4$ thin film is deposited by e-beam evaporation. Deposited films are annealed for 1 hour in N2 ambient at $150^{\circ}C\~600^{\circ}C$. Dielectric constant of ferroelectric is about 60-100 and breakdown field is about IMV/cm. In this paper, the TFT using ferroelectric consisted of double layer gate insulator to minimize the leakage current. a-SiN:H, a-Si:H (n-type a-Si:H) are deposited onto $SrTiO_3$ film to make MFNS(Metal/ferroelectric/a-SiN:H/a-Si:H) by PECVD. In this paper, TFR using ferroelectric has channel length of$8~20{\mu}m$ and channel width of $80~200{\mu}m$. And it shows that drain current is $3.4{\mu}A$at 20 gate voltage, $I_{on}/I_{off}$ is a ratio of $10^5\~10^8,\;and\;V_{th}$ is$4\~5\;volts$, respectively. In the case of TFT without having ferroelectric, it indicates that the drain current is $1.5{\mu}A$ at 20gate voltage and $V_{th}$ is $5\~6$ volts. If properties of the ferroelectric thin film are improved, the performance of TFT using this ferroelectric thin film can be advanced.

Contact Transfer Printing Using Bi-layer Functionalized Nanobio Interface for Flexible Plasmonic Sensing

  • Lee, Jihye;Park, Jiyun;Lee, Junyoung;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.413-413
    • /
    • 2014
  • In this paper, we present a fabrication method of functionalized gold nanostructures on flexible substrate that can be implemented for plasmonic sensing application. For biomolecular sensing, many researchers exploit unconventional lithography method like nanoimprint lithography (NIP), contact transfer lithography, soft lithography, colloidal transfer printing due to its usability and easy to functionalization. In particular, nanoimprint and contact transfer lithography need to have anti-adhesion layer for distinctive metallic properties on the flexible substrates. However, when metallic thin film was deposited on the anti-adhesion layer coated substrates, we discover much aggravation of the mold by repetitive use. Thus it would be impossible to get a high quality of metal nanostructure on the transferred substrate for developing flexible electronics based transfer printing. Here we demonstrate a method for nano-pillar mold and transfer the controllable nanoparticle array on the flexible substrates without an anti-adhesion layer. Also functionalization of gold was investigated by the different length of thiol applied for effectively localized surface plasmonic resonance sensing. First, a focused ion beam (FIB) and ICP-RIE are used to fabricate the nanoscale pillar array. Then gold metal layer is deposited onto the patterned nanostructure. The metallic 130 nm and 250 nm nanodisk pattern are transferred onto flexible polymer substrate by bi-layer functionalized contact imprinting which can be tunable surface energy interfaces. Different thiol reagents such as Thioglycolic acid (98%), 3-Mercaptopropionic acid (99%), 11-Mercaptoundecanoic acid (95%) and 16-Mercaptohexadecanoic acid (90%) are used. Overcoming the repeatedly usage of the anti-adhesion layer mold which has less uniformity and not washable interface, contact printing method using bi-layer gold array are not only expedient access to fabrication but also have distinctive properties including anti-adhesion layer free, functionalized bottom of the gold nano disk, repeatedly replicate the pattern on the flexible substrate. As a result we demonstrate the feasibility of flexible plasmonic sensing interface and anticipate that the method can be extended to variable application including the portable bio sensor via mass production of stable nanostructure array and other nanophotonic application.

  • PDF

CHARACTERISTICS OF HETEROEPITAXIALLY GROWN $Y_2$O$_3$ FILMS BY r-ICB FOR VLSI

  • Choi, S.C.;Cho, M.H.;Whangbo, S.W.;Kim, M.S.;Whang, C.N.;Kang, S.B.;Lee, S.I.;Lee, M.Y.
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.809-815
    • /
    • 1996
  • $Y_2O_3$-based metal-insulator-semiconductor (MIS) structure on p-Si(100) has been studied. Films were prepared by UHV reactive ionized cluster beam deposition (r-ICBD) system. The base pressure of the system was about $1 \times 10^{-9}$ -9/ Torr and the process pressure $2 \times 10^{-5}$ Torr in oxygen ambience. Glancing X-ray diffraction(GXRD) and in-situ reflection high energy electron diffracton(RHEED) analyses were performed to investigate the crystallinity of the films. The results show phase change from amorphous state to crystalline one with increasingqr acceleration voltage and substrate temperature. It is also found that the phase transformation from $Y_2O_3$(111)//Si(100) to $Y_2O_3$(110)//Si(100) in growing directions takes place between $500^{\circ}C$ and $700^{\circ}C$. Especially as acceleration voltage is increased, preferentially oriented crystallinity was increased. Finally under the condition of above substrate temperature $700^{\circ}C$ and acceleration voltage 5kV, the $Y_2O_3$films are found to be grown epitaxially in direction of $Y_2O_3$(1l0)//Si(100) by observation of transmission electron microscope(TEM). Capacitance-voltage and current-voltage measurements were conducted to characterize Al/$Y_2O_3$/Si MIS structure with varying acceleration voltage and substrate temperature. Deposited $Y_2O_3$ films of thickness of nearly 300$\AA$ show that the breakdown field increases to 7~8MV /cm at the same conditon of epitaxial growing. These results also coincide with XPS spectra which indicate better stoichiometric characteristic in the condition of better crystalline one. After oxidation the breakdown field increases to 13MV /cm because the MIS structure contains interface silicon oxide of about 30$\AA$. In this case the dielectric constant of only $Y_2O_3$ layer is found to be $\in$15.6. These results have demonstrated the potential of using yttrium oxide for future VLSI/ULSI gate insulator applications.

  • PDF

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF