• 제목/요약/키워드: High bar

검색결과 1,593건 처리시간 0.029초

제련설비용 대전류 동 Bus Bar의 온도해석 (Analysis of High Current Copper Bus Bar Temperature in Smelting Plants)

  • 곽병길;김창환;최병주;김규호;이상봉
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.26-32
    • /
    • 2014
  • In electrolysis smelting plants that using high DC current, the bus bar is most important facility for delivering the high current. The copper made bus bar is widely used for various advantages as good electrical and thermal conductivity, resonable malleability, ductility, and not rust easily. However, when high current in copper bus bar, temperature rises and maximum allowable current capacity is restricted by temperature of bus bar. In this paper, we investigated temperature variation of copper bus bar by putting cooling water channel imposed to bus bar construction. For the validity, various simulations were carried out.

비용 효율이 높은 24kV급 고압배전반 개발을 위한 Bus Bar 사이즈에 따른 전·자기 손실 특성 분석 (A Study on the Characteristics of the Electric Field and Electromagnetic Loss according to Bus Bar Size for a cost-effective 24kV High Voltage Switchgear)

  • 홍종기;허정일;남석호;강형구
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.220-224
    • /
    • 2012
  • The analysis on the bus bar effect is conducted to develop a cost effective 24kV/2,000A switchgear. The temperature enclosures and bus bars could rise due to several heat sources such as eddy current losses and copper losses. Therefore, a study on the characteristics of the electric field intensity and electromagnetic loss according to the bus bar size in a bus bar compartment is essential to design a electrically reliable high voltage switchgear. It is investigated that the electromagnetic influence to the temperature rising and the dielectric stability according to various bus bar sizes by using finite element method(FEM). The electric field intensity and electromagnetic loss according to various bus bar sizes are calculated to design a reliable and a high voltage switchgear. As results, it is found that the electromagnetic loss and the dielectric stability of bus bar could be determined by a bus bar size. It means that a cost effective 24kV/2,000A high voltage switchgear could be developed by selecting the proper size of a bus bar. Also, it is recognized that the electromagnetic characteristics according to various bus bar sizes in order to design an electrically stable high voltage switchgear when the enclosure size is determined as a fixed value. Futhermore, studies on the various nominal voltage class and bus bar sizes will be conducted to develop a cost effective high voltage switchgear.

원전구조물 고강도철근 모듈화를 위한 적용방법 연구 (Study of application method for the Rebar Modulation of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 임상준;이병수;방창준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2013
  • To minimize construction of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop appication design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are. This study is to introduce application method for the Rebar Modulation of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures.

  • PDF

Structural Performance of Steel Pipe Splice for SD500 High-strength Reinforcing Bar under Cyclic Loading

  • Kim, Hyong-Kee
    • Architectural research
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 2008
  • It is the purpose of this study to evaluate the structural performance of steel pipe splice for SD500 high-strength reinforcing bar, through a cyclic loading test. The experimental variables adopted in this study include the development length of rebar, the type of sleeve, and size of reinforcing bar, among others. The results of this study showed that the developed steel pipe splice system for SD500 high-strength reinforcing bar, retained the structural performance required in domestic, ACI and AIJ code. It is considered that the study result presented in this paper can be helpful in developing a reasonable design method for a steel pipe splice system for SD500 high-strength reinforcing bar.

원전구조물 고강도철근 모듈화를 위한 용접방법 성능평가 (Performance Evaluation of Welding Method for Modular of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 임상준;이한우;김형섭;방창준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.278-280
    • /
    • 2013
  • To minimize construction quantity of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop application design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are.

  • PDF

복합재료 보링바의 동적 특성에 관한 연구 (A Study on the Dynamic Characteristics of the Composite Boring Bar)

  • 황희윤;김진국;이대길
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.206-210
    • /
    • 2003
  • Machining of deep holes with conventional boring bars frequently induce chatter vibration because of their low dynamic stiffness which is defined as the product of static stiffness and damping of conventional boring bar materials. In addition, the specific stiffness ($E/{\rho}g$) of boring bars is more important than the static stiffness to increase the fundamental natural frequency of boring bars in high speed machining. Therefore, boring bar materials should have high static stiffness and high damping as well as high specific stiffness. The best way to meet requirements is to employ fiber reinforced composite materials for high speed boring bars because composite materials have high static stiffness, high damping and high specific stiffness compared to conventional boring bar materials. In this study, the dynamic characteristics of carbon fiber epoxy composite boring bars were investigated. From the metal cutting test, it was found that the chatter was not initiated up to the ratio of length to diameter of 10.7 at the rotating speed of 2,500 rpm.

  • PDF

Effects of Angle of Foot-Bar and Knee Posture on Core Muscle Activity during Pilates Reformer High-Plank

  • Kihong Kim;Hanna Choi;Hwanjong Jeong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권1호
    • /
    • pp.156-162
    • /
    • 2024
  • The purpose of this study was to investigate the muscle activity of internal oblique, rectus femoris, and multifidus according to knee posture and foot bar angle during pilates reformer high flank exercise. Twelve women in their 20s were recruited within six months of their experience as pilates instructors. The subjects performed six types of high flanks according to knee posture and foot bar angle. EMG signals of internal oblique, rectus femoris, and multifidus during exercise were measured and analyzed by integral EMG. The collected data were processed by repeated measures two-way ANOVA. In this paper it shows the following results. First, internal oblique iEMG was not significantly different according to knee posture and foot bar angle. Second, the rectus femoris had an interaction effect according to knee posture and foot bar angle. Third, there was no significant difference in multifidus according to knee posture and foot bar angle. In conclusion, according to the exercise method, the activity of the rectus femoris was the highest in the knee bending and high foot-bar angle high plank exercise, and there was no difference between the internal oblique and multifidus.

비틂홉킨슨봉을 이용한 알루미늄합금의 고속 전단변형 실험 (High strain rate test of aluminum alloy with torsional Hopkinson bar)

  • 전병선;유요한;정동택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 추계학술대회논문집
    • /
    • pp.80-83
    • /
    • 1997
  • The split Hopkinson bar technique is the most widely used method to study material behavior at high strain rate deformation. In the present paper, a torsional Hopkinson bar for testing thin-walled tube specimens at high strain rate is described. From the experiment of aluminum 6061, dynamic stress-strain relationship can be obtained and dynamic result is compared with static one.

  • PDF

고속도강 선.봉재의 중심부 용융현상방지를 위한 압연공정 해석 (Analysis of Wire/Bar Rolling Process of High Speed Steel for Prevention of Center Fusion)

  • 이수연;정효태;하태권;정재영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.318-321
    • /
    • 2007
  • The temperature distribution of high speed tool steel wire/bar during high speed hot rolling procedures has been studied in this study. The tool steels wire/bar show severe temperature gradient during rolling procedures and the temperature of center part much higher than that of the surface. This temperature gradient accumulated after every rolling procedure and the center of rolled wire/bar could be remelt in a certain stage to cause inside defects. In the present study, the temperature distribution was simulated using finite element method and the processing parameters such as rolling speed, cooling condition, has been discussed to prevent the temperature increases of center wire/bar.

  • PDF

수치해석을 이용한 SHPB 시험의 마찰영향 분석 (An Investigation into the effect of friction in the split hopkinson pressure bar (SHPB) test by numerical experiments)

  • 차성훈;신명수;신현호;김종봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.204-209
    • /
    • 2008
  • The interest in the mechanical behavior of materials at high strain rates has increased in recent years, and by now it is well known that mechanical properties can be strongly influenced by the speed of applied load. The split Hopkinson pressure bar (SHPB) has been widely used to determine mechanical properties of materials at high loading rates. However, to ensure test reliability, measurement error source must be accounted for and eliminated. During experiment, the specimens were located between the incident and the transmit bar. The presence of contact frictions between the test bars and specimen may cause errors. In this work, numerical experiments were carried out to investigate the effect of friction on test results. In SHPB test, the measured stress by the transmitted bar is assumed to be flow stress of the test specimen. Through the numerical experiments, however, it is shown that the measured stress by the transmit bar is axial stress components. When, the contact surface is frictionless, the flow stress and the axial stress of the specimen are about the same. When the contact surface is not frictionless, however, the flow stress and the axial stress are not the same anymore. Therefore, the measured stress by the transmitted bar is not flow stress. The effect of friction on the difference between flow stress and axial stress is investigated.

  • PDF