• Title/Summary/Keyword: High accuracy

Search Result 8,862, Processing Time 0.046 seconds

Estimation of Permeability and Initial Pressure in Reservoir by DFIT Data Analysis (DFIT 자료 해석을 통한 저류층의 투과도 및 초기압력 추정)

  • Kim, Tae Hong;Lee, Sung Jun;Lee, Kun Sang
    • Tunnel and Underground Space
    • /
    • v.23 no.3
    • /
    • pp.169-179
    • /
    • 2013
  • Well testing in unconventional reservoirs, such as tight or shale gas formations, presents considerable challenges. It is difficult to estimate the reservoir properties in ultra-low permeability formation because of poor inflow prior to stimulation and excessive test duration. Moreover, radial flow may not develop in hydraulically fractured horizontal wells. For these reasons, the cost of test is high and the accuracy is relatively low. Accordingly, industry is turning to an alternate testing method, diagnostic fracture injection test (DFIT), which is conducted prior to the main hydraulic fracture treatments. Nowadays, DFIT are regarded as the most practical way to obtain good estimates of reservoir properties in unconventional reservoirs. Various methods may be used for interpreting DFIT data. This paper gives an explanation of those methods in detail and examines three actual field data. These show how various analysis methods can be applied to consistently interpret fracture closure pressure and time, as well as before and after closure flow regimes and reservoir properties from field data.

Clinical Features of Electrogastrogram in Dyspeptic Patients with Stomach Qi Deficiency (위기허증으로 진단된 소화불량 환자의 임상적 특징; 위전도 검사를 중심으로)

  • Jeong, Hae-in;Kim, Dong-yoon;Baek, So-young;Lee, Ha-nul;Lee, Hyun-jin;Cho, Yun-jae;Ha, Na-yeon;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.467-477
    • /
    • 2020
  • Objectives: This study investigated the cutaneous electrogastrogram (EGG) and other clinical characteristics of dyspeptic patients who have been diagnosed with Stomach Qi Deficiency (SQD) using the Scale for Stomach Qi Deficiency (SSQD). Methods: This study reviewed the clinical records of 38 patients with dyspepsia who were evaluated with SSQD and EGG at the Department of Digestive Diseases of Kyung Hee University Korean Medicine Hospital in Seoul, Korea from November 1, 2019 to February 29, 2020. We evaluated the EGG and other clinical characteristics of the SQD patients to determine if there was an association between the SSQD scores and the EGG. Results: In terms of the EGG, the SQD patients showed no significant increase in the percentage of normal slow wave after a meal and a slightly decreased power ratio at Channel 1 and Channel 2. We also found an association between the SSQD scores and the EGG parameters at Channel 1 and Channel 3. The average Ryodoraku score of the patients was 33.00±14.90 (μA). In the Heart Rate Variability (HRV) test, the average Total Power (TP) and Low Frequency/High Frequency (LF/HF)) ratio was 1356.60±13 6.41(ms2) and 1.68±2.25, respectively. Conclusions: The results of this study suggest that clinicians can use Electrogastrography to enhance accuracy when diagnosing the SQD pattern.

Take advantage of ESWL in comparison measurement of Proximal stone against Mid Ureteral Stone according to its provability of pulverization (ESWL을 이용한 Proximal, Mid Ureteral Stone의 쇄석시 각 조건에 대한 쇄석율의 비교 측정)

  • Kang, Kwang-Soo;Lee, Sang-Bok;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • A urolithiasis, also called calculus, is one of the brutal illnesses, which has constantly harassed humanbeings from time immemorial. However, there is no appropriate method of prevention so far. So, Urological therapy must be followed upon those patients. The biggest problem of urolithiasis is usually causing harsh pain, fever, and throw up. The pain would be more intensified when something came through the ureter or the moment of convulsion caused beyond transmission of urinary calculus. Even strong painkillers, such as fentanyl and Pethidine, can not handle those harshly pain easily. Therefore, a prompt action of medical check up and its therapy must be required to those patients. This thesis paper has put the accent on the specific therapy, known as ESWL (Extracorpereal Shock Wave Lithotripsy), which have generated quite optimum resolution to patients, who received harsh pain from Proximal ureteral stone and Mid ureteral stone and because of its low provability of pulverization. The results of the experiment confirmed that the stone, located between Proximal and Mid ureter, has lower provability of pulverization than distal ureter, because its accuracy rate on shock wave, in respect of breathing, are low. However, decrease in discharge interval have enhanced provability of pulverization. it can also intensify probability of pulverization and its safety by discharging high power with appropriate intervals, and that is more efficient than discharging low power with frequent time.

Steady-state Thermal Analysis of 5 kW IPMSM Using Thermal Equivalent Circuit (열등가회로를 이용한 5 kW 급 영구자석 동기전동기의 정상상태 열 특성 해석)

  • Kim, Tae Hyun;Yoo, Young Bum;Na, Jong Seung;Ryu, Kyongtae;Moon, Yoon Jae;Lee, Jae Heon;Lee, Ju;Park, Chan Bae;Moon, Seung Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.951-956
    • /
    • 2014
  • Steady-state thermal analysis was performed on a thermal equivalent circuit to determine the heat generation during operation of an interior permanent magnet synchronous motor (IPMSM). New machines must be compact and light and produce high torque density under extreme environmental conditions. Thermal analysis of an IPMSM is particularly important because excessive heat generated from the core and magnet reduces the IPMSM's output and has adverse effects on the durability. Therefore, steady-state thermal analysis of an IPMSM was performed for changes in the design variables using a thermal equivalent circuit. The changed variables were the axis length and thickness of the housing. The results of this method were compared with those of the finite element method to verify the accuracy and reliability.

RCCA End-Tip Examination by ECT (원자로 제어봉 End-Tip 원주방향균열 와전류검사)

  • Lee, H.J.;Nam, M.W.;Jung, G.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.455-463
    • /
    • 1998
  • RCCA(rod cluster control assembly) End-Tip suffers from neutron irradiation and constant vibration due to high-speed internal flow of primary coolant during plant operation. Such operating conditions cause the RCCA end-tip crackings around tile circumferential weldment of the end-tip, and in some cases, the defective end-tips were completly broken loose. However, no reliable inspection techniques for end-tip crackings were developed in the past, although some techniques exist for inspecting RCCA control rod wears. Therefore, NDE group at KEPRI has developed an ECT technique for the detection and the sizing of the end-tip crackings. The technique uses a specially designed surface-riding probe that can detect size of circumferential crackings with an accuracy of ${\pm}5.31%$ RMS error. This paper describes the ECT instrumentation including the ECT probes, calibration bars, as well as technical approaches.

  • PDF

Comparative Analysis of Focal Length Bias for Three Different Line Scanners (초점거리 편의가 지상 정확도에 미치는 영향 비교 연구 - 세가지 라인 스캐너를 대상으로 -)

  • Kim, Changjae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.363-371
    • /
    • 2014
  • Most space-borne optical scanning systems adopt linear arrayconfigurations. The well-knownthree different types of space-borne sensors arealong-track line scanner, across-track linescanner, and three line scanner. To acquire accurate location information of an object on the ground withthose sensors, the exterior and interior orientation parameters are critical factors for both of space-borne and airborne missions. Since the imaging geometry of sensors mightchange time to time due to thermal influence, vibration, and wind, it is very important to analyze the Interior Orientation Parameters (IOP) effects on the ground. The experiments based on synthetic datasets arecarried out while the focal length biases are changing. Also, both high and low altitudes of the imagingsensor were applied. In case with the along-track line scanner, the focal length bias caused errors along the scanline direction. In the other case with the across-track one, the focal length bias caused errors alongthe scan line and vertical directions. Lastly, vertical errors were observed in the case ofthree-line scanner. Those results from this study will be able to provide the guideline for developing new linearsensors, so as for improving the accuracy of laboratory or in-flight sensor calibrations.

A Study on the Tidal Harmonic Analysis, and long-term Sea Level Ocillations at Incheon Bay (인천만의 조석조화해석 및 장기해수면 변동연구)

  • Lee, Yong-Chang
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.5
    • /
    • pp.505-513
    • /
    • 2010
  • This study investigate the characteristics of tidal constituents, and long-term mean sea level oscillations at Incheon bay. For this, the conditions of three tide stations around Incheon bay have examined, and carried out harmonic analysis on water level data for periods of about 40 years(1960~2007). Four major tidal constituents($M_2$, $S_2$, $K_1$, $O_1$) of each tide station showed tendency that change over the 18.61year lunar node cycle, and the type of tide at three stations is mainly semi-diurnal tides. And also, the past monthly tidal modulations are especially sensitive to the cumulative year of water level data in accuracy of tidal prediction. In case that regard the detached data at three tide stations as a single time series data of 40 years, the results of analysis on a single time series, long-term mean sea level oscillations and modulations of tidal datum at tide stations appears with a range of about 10cm, respectively. In addition, the predicted tides at the Inchcon harbor by global and regional tide models of OSU(Oregon State University) based on various satellite altimetric(Topex Poseidon, Topex Tandem, ERS, GFO) data are compared with the observed tides by KHOA(the Korea Hydrographic and Oceanographic Administration). The results show that the high resolution regional model is a quite good agreement at coastal shallow water region.

A Comparative Study of the Assay Methods Used to Quantify Fermentable Sugar in Makgeolli Sul-dut (막걸리 술덧의 발효성 당 분석방법 비교 연구)

  • Kim, Byong-Soo;Kim, Gye-Won;Shim, Jae-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.48-53
    • /
    • 2016
  • The objective of this study was to evaluate the accuracy and efficiency of different methods used for the fermentable sugar assay in the production of Makgeolli sul-dut. In the initial stage of fermentation, Ipguk treatment produced a higher alcohol content compared to the Nuruk treatment. However, the alcohol content was not significantly different between the two starters at the final stage of fermentation. Acidity in the Ipguk treatment was higher than that of Nuruk throughout the fermentation period. After analyzing the fermentable sugars using dinitrosalicylic acid (DNS), Fehling's method, refractometer, glucose kit, and high performance liquid chromatography (HPLC), it was confirmed that the HPLC method was the most accurate for fermentable sugar quantification. In both types of starters, DNS and Fehling's methods showed results comparable to HPLC in terms of fermentable sugar content, while the glucose kit and refractometer analyses showed relatively large discrepancies, indicating that the Fehling's method could also be effective for the analysis of fermentable sugars in the manufacture of Makgeolli.

Three body problem in early 20th century (20세기초의 삼체문제에 관해서)

  • Lee, Ho Joong
    • Journal for History of Mathematics
    • /
    • v.25 no.4
    • /
    • pp.53-67
    • /
    • 2012
  • Today, it is necessary to calculate orbits with high accuracy in space flight. The key words of Poincar$\acute{e}$ in celestial mechanics are periodic solutions, invariant integrals, asymptotic solutions, characteristic exponents and the non existence of new single-valued integrals. Poincar$\acute{e}$ define an invariant integral of the system as the form which maintains a constant value at all time $t$, where the integration is taken over the arc of a curve and $Y_i$ are some functions of $x$, and extend 2 dimension and 3 dimension. Eigenvalues are classified as the form of trajectories, as corresponding to nodes, foci, saddle points and center. In periodic solutions, the stability of periodic solutions is dependent on the properties of their characteristic exponents. Poincar$\acute{e}$ called bifurcation that is the possibility of existence of chaotic orbit in planetary motion. Existence of near exceptional trajectories as Hadamard's accounts, says that there are probabilistic orbits. In this context we study the eigenvalue problem in early 20th century in three body problem by analyzing the works of Darwin, Bruns, Gyld$\acute{e}$n, Sundman, Hill, Lyapunov, Birkhoff, Painlev$\acute{e}$ and Hadamard.

The study on the quality characteristics factor of medium-sized orbit scroll (중형 선회 스크롤의 품질 특성 인자에 대한 연구)

  • Kim, Jae-Gi;Lim, Jeng-Taek;Kang, Soon-Kook;Park, Jong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.718-723
    • /
    • 2016
  • The use of the scroll compressor in the air conditioning of medium-sized vehicles has increased because of its low torque fluctuation, high energy efficiency and low noise. In addition, the main components of the compressor have been changed from steel to aluminum to reduce its weight, following studies on the constituent materials. The processing precision of the fixed scroll and orbiting involute scroll wrap of the scroll compressor must be below $10{\mu}m$. To ensure this, the surface roughness and contour tolerance are measured. To improve the hardness of the orbiting scrolls using aluminum subjected to anodizing treatment and as the base material, we used a sealing treatment and measured the resulting characteristics. The aluminum materials were made of an Al-Mg-Cu based alloy including small amounts of Ni, Fe, and Zn. The surface roughness was less than $3{\mu}m$ and the processing accuracy was within $10{\mu}m$. Also, the hardness of the nanodiamonds with CNTs used in the sealing treatment was more than 450. This was found to improve the hardness of the material by 50% or more compared to the water sealing treatment and there was little difference between the use of carbon nanotubes and nanodiamonds as sealing materials.