• Title/Summary/Keyword: High Xe

Search Result 141, Processing Time 0.034 seconds

Steam Reforming of Methane in a Solar Concentrated Receiver Reactor (집광된 태양열을 반응기에서의 메탄 수증기개질 연구)

  • Kim, Ki-Man;Nam, Woo-Seok;Han, Gui-Young;Seo, Tae-Beom;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.172-175
    • /
    • 2006
  • Steam reforming of methane using Xe-arc solar simulator was studied for converting solar radiation into energy foam that one can readily utilize. The Xe-arc lamp produce a spectrum similar to that of the sun. SiC ceramic foam, resist high temp.$(>900^{\circ}C)$, is used to catalytically active foam absorber, and to support of reforming catalyst. The catalyst on the surface of foam were directly irradiated with solar simulated xe-light in order to carry out the steam reforming of methane. The reactor was made of stainless steel and quartz window was located on a place of the xe-light irradiation and temperature was controlled using K-type thermocouple in contact with catalyst located inside the reactor. The result show that a possibility of solar reforming using catalytically active foam absorber is exist.

  • PDF

The Effect of MgO Rate Preparing Conditions and Xe Partial Pressure on the Relative Life time of an AC Plasma Display Panel

  • Park, Cha-Soo;Park, Min-Seok;Park, Joon-Young;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.2
    • /
    • pp.35-42
    • /
    • 2003
  • This paper proposes a relative lifetime test method of MgO thin film. The suggested test conditions are 5$0^{\circ}C$, 400Torr, 20% over-voltage and 300KHz. The relative lifetime of MgO thin film is significantly affected by the MgO preparing conditions and Xe partial pressure. As result, the lifetime of the AC plasma display panel (PDP) is increased with an MgO thickness of 2000$\AA$ to 8000$\AA$ but is saturated over 5000$\AA$ (up to 9000 $\AA$). In addition, as Xe partial pressure increases, AC PDP lifetime increases.

New Electrode Shape for High Xe-content Gas in AC PDP

  • Park, Cha-Soo;Choi, Joon-Young;Kim, Goon-Ho;Kim, Joong-Kyun;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.4 no.4
    • /
    • pp.13-18
    • /
    • 2003
  • One of the most important issues in AC PDP is the improvement of luminous efficiency. One possible method for achieving this aim is by increasing Xe partial pressure in discharge gas mixture. The increase of Xe ratio, however, causes the driving voltage to rise, even if brightness is increased. In this study, a new electrode shape is proposed. A test panel fabricated by using a new electrode shows that efficacy has improved by 25 % and sustain voltage has decreased by 20 % compared with the conventional structure.

The effects of high Xe contents on the improvement of luminous efficacy of AC PDP with Segmented electrode in Delta color arrayed Rectangular subpixels(SDR)

  • Kim, Tae-Jun;Jeong, Dong-Cheol;Chung, Woo-Joon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.79-82
    • /
    • 2002
  • In this paper, we investigate the characteristics of luminous efficacy as a function of Xe partial pressure in AC PDP. SDR structure has shown much larger increment of luminous efficacy compared with the conventional one especially below 10% Xe contents. The luminous efficacy around 4.0 lm/W is achieved with Ne-Xe10%, 400Torr in Monochrome green phosphor test panel under 10kHz continuous sustaining frequency.

  • PDF

Mechanism of High Luminous Efficiency in Delta Color Arrayed, Enclosed Sub-pixel Structured AC PDP with High Xe Content

  • Bae, Hyun-Sook;Kim, Tae-Jun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.59-62
    • /
    • 2004
  • We investigated the effect of Xe content variation on the luminous efficiency of two different sub-pixel types, i.e., segmented electrode in delta color arrayed enclosed sub-pixel (SDE) and conventional stripe barrier type, in an ac plasma display panel through three-dimensional numerical simulations. The conventional cell type was found to have higher VUV generation efficiency as compared with that of SDE structure, but as the Xe content increased, the SDE type showed higher improvements in efficiency due to the lower plasma loss to the barrier walls.

  • PDF

The New Electrode Shape for Xe of High Density in AC PDP

  • Kim, Goon-Ho;Lee, Young-Kwon;Choi, Yoon-Chang;Lee, Sang-Jin;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.83-87
    • /
    • 2003
  • One of the most serious problems in AC PDP is low luminous efficiency. One possible candidate for solving such a problem is using high Xe partial pressure. Increase of Xe percentages causes the driving voltage to rise, although brightness is increased. In this study, a new electrode structure is proposed to solve this problem. A test panel fabricated by using new electrode shows improvement of efficiency by 25% and reduction of sustain voltage by 20% compared with the conventional structure.

  • PDF

Experimental Investigation of the Excited Xe Atoms Density in Ultra-high-resolution PDPs

  • Ishii, Keiji;Hirano, Yoshikuni;Murakami, Yukio
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.61-64
    • /
    • 2008
  • We investigated experimentally the influence of the generation efficiency for excited Xe atoms on ultra-fine horizontal cell pitch AC PDPs. In the case of a 0.1 mm cell pitch, the sustain voltage increased; however, the generation efficiency was equal to or higher than for the conventional 0.22 mm cell pitch.

  • PDF

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

Fish Fauna in the Bolaven Plateau and Trophic Polymorphism of Poropuntius bolovenensis in Laos (라오스볼라벤고원의어류상과 Poropuntius bolovenensis의 섭식기구다형성)

  • Kang, Dong-Won;THAMAVONGSENG, Payou;Lee, Hak Young;Choi, Seung-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.3
    • /
    • pp.369-375
    • /
    • 2016
  • This survey was conducted during March to April 2014 in the main stream and tributaries of Xe Pian and Xe Namnoy in order to investigate fish fauna in the Bolaven Plateau. Fish belonging to twenty eight species and eight families were collected from the main stream and tributaries of Xe Namnoy and Xe Pian during the survey period. Among them, Devario salmonatus, Poropuntius bolovenensis, Annamia sp., Sewellia elongata, Schistura bolavenensis, Schistura sp.1, Schistura sp.2, Schistura sp.3, Schistura sp.4, and Macronathus sp. were endemic species in the Bolaven Plateau, indicating a high prevalence rate of endemic species (35.7%) in the area. Meanwhile, Kottelat (2000, 2013) has been reported that four species of Poropuntius inhabit the Bolaven Plateau. However, the major morphic characteristics of Poropuntius species found in the Bolaven Plateau were mostly overlapped, except for the shape of their mouth. The young fish of Poropuntius (> 70 mm SL) have only generalized mouth while the of adult fish the shape of their mouth have two phenotype (narrow and broad). Therefore, it is assumed that Poropuntius species in the Bolaven Plateau has trophic polymorphism as the same species exhibits two different mouth shapes.

The influence of Ne-Xe gas mixture ratio on vacuum Ultraviolet and infrared line in AC-PDP

  • Oh, Phil-Y.;Cho, I.R.;Jung, Y.;Park, K.D.;Ahn, J.C.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.743-747
    • /
    • 2003
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) and infrared(IR) rays in surface discharge AC-PDP with Ne-Xe mixture gas. The influence of Ne-Xe gas-mixture ratio on resonance state $Xe^{\ast}(3P_{1})$ and exited state $Xe^{\ast}(3P_{2})$ has been investigated. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828 nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The electron temperature and plasma density have been experimentally measured from the center of sustaining electrode gap by a micro Langmuir probe in AC-PDPs. The plasma density from the center of sustaining electrode gap are shown to be maximum value of $9{\times}10^{11}cm^{-3}$, where the electron temperature is about 1.6 eV in this experiment

  • PDF