In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of $20{\sim}100mTorr$ Xenon pressure, $50{\sim}200W$ RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.
Kim, Hyun-Gyu;Lee, Ho-Jun;Kim, Dong-Hyun;Park, Chung-Hoo;Cho, Sung-Yong;Ha, Chang-Seung;Wi, Sung-Suk;Sim, Choung-Hwan;Lee, Hae-June
한국정보디스플레이학회:학술대회논문집
/
2009.10a
/
pp.732-735
/
2009
In this paper, high Xe(Ne+Xe 10%, 20%, 30%) AC-PDP's discharge characteristics according to aging time were studied. The static margin, Vt close curve, discharge time lag was measured for experiments. According to increase of Xe partial pressure, the static margin and luminance was increased. As the result of analysis for misfiring probability, the misfiring is frequently occurred in accordance with increasing of aging time. To improve misfiring, we proposed 3Reset waveform and achieved misfiring probability which was improved.
Kim, G.H.;Lee, D.K.;Lee, Y.K.;Heo, J.E.;Kim, D.H.;Lee, H.J.;Park, C.H.
Proceedings of the KIEE Conference
/
2002.07c
/
pp.1658-1661
/
2002
Up to now, one of the most serious problems in AC PDP is low luminous efficiency. One possible candidate for solving such problem is using high density Xe. But an increase of the Xe percentage cause rising of the driving voltage and so even if brightness is being increased, luminous efficiency is decreased. In this study, to solve this problem, we proposed new electrode structure. A test panel fabricated using new electrode shows an improvement of efficiency by 25% and a lowering of sustain voltage by 20% compared with the conventioned structure.
Experimental measurements are reported and compared with the results of a two-dimensional fluid simulation for the investigation of the discharge characteristics regarding the change of the mixture ratio of Ne-Xe-He noble gases. The increase of Xe contents results in the increases of luminance and luminous efficiency while it also results in the increase of the breakdown voltage and the discharge time lag. The addition of He gas increases the brightness and the luminance efficiency. When Xe partial pressure is low, the luminance efficiency increases with the amount of He at the same total pressure. When Xe partial pressure is high, however, the luminance efficiency has a maximum value when the partial pressure of He is about 10% of the total pressure for a standard AC PDP cell with Xe fraction of $10{\sim}30%$.
The Transactions of The Korean Institute of Electrical Engineers
/
v.58
no.1
/
pp.155-159
/
2009
To increase the luminance and luminous efficacy in the discharge for alternating current plasma display panel (ac PDP), the increment of Xe contents and long discharge gap are necessary. However, the driving voltage and the cost of driving circuit increases in the high Xe contents and long discharge path condition. In this paper, a long gap ITO hump electrode (LGH) model for discharge cells of ac PDP is evaluated in the various Xe contents($5{\sim}20%$). The discharge voltage of LGH structure is lower about 30V than that of ITa reference structure with same main discharge gap. The LGH structure has lower power consumption and higher luminance than those of reference structure, respectively. Also, the luminous efficacy of LGH structure is higher about 20% than that of ITO reference structure in the 20% Xe contents.
Conventional backlight for liquid crystal display (LCD) uses mercury which leads to environmental pollution. In this study, characteristics of AC coplanar type mercury-free plasma flat lamp have been studied. Pollution-free Xe-He is adopted as a discharge gas system. Since the Xe gas has a lower efficiency in generating vacuum ultraviolet (VUV) than mercury, the improvement of luminance and luminous efficiency in the Xe gas system is very important. The electrode, dielectric, and phosphor layers constituting lamp are formed on the bottom glass by the screen printing method. The effects of pulse shape, on-time, and pulse frequency on the luminance and luminous efficiency have been examined. For Xe(5%)-He gas, the lamp exhibits higher efficiency with sharper pulse shape, higher peak voltage, and shorter pulse on-time (up to 2 $\mu\textrm{s}$). Higher efficiency and lower consumption of power were obtained at 30 kHz than at 60 kHz. The collision of ion to bottom electrodes is a dominant factor to raise the lamp temperature. Therefore the high voltage and low current discharge system is necessary for reduction of the lamp temperature as well as for enhancement of the luminous efficiency.
The effects of various sustain waveforms on the discharge characteristics, such as discharge current waveform, IR waveform, luminance, luminous efficiency, power consumption, and static margin are investigated under high Xe (20%) gas mixture at 200 kHz. The four types of sustain waveforms, such as non-overlapped sustain waveform without auxiliary pulse, non-overlapped sustain waveform with auxiliary pulse, overlapped sustain waveform without auxiliary pulse, overlapped sustain waveform with auxiliary pulse, are examined intensively. As a result, the overlapped sustain waveform with auxiliary pulse shows the best discharge characteristics under high Xe (20%) gas mixture at 200 kHz.
Over 5lm/W white luminous efficacy was obtained by 11" color test panel with narrowed discharge electrodes combined with high Xe partial pressure. By using optical spectroscopic methods, it was suggested that the electron heating efficiency is the most significant to improve the plasma efficiency in our experimental conditions.
Journal of the Korean Institute of Telematics and Electronics
/
v.13
no.5
/
pp.17-23
/
1976
The buildup of fission product, i.e. Xe-135 poisoning, is a prime factor in restarting a nuclear reactor from the shutdown, which was under normal operation in the high flux thermal reactor, It is caused by the high absorption crosssection of Xe-135 to thermal neutrons and its long half life, from which the thermal power is affected. It is then possible to restart a nuclear reactor after the sufficient excess reactivity to override this poisoning must be inserted, or its concentration is decreased sufficiently when its temporary shutdown is required. As ratter of fact, these have an important influence not only on reactor safety but also on economic aspect in operation. Considering these points in this study, the shutdown process was cptimized using the Pontryagin's maximum principle so that the shutdown mirth[d was improved as to restart the reactor to its fulpower at any time, but the xenon concentration did not excess the constrained allowable value during and after shutdown, at the same time all the control actions were completed within minimum time from beginning of the shutdown.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.