• Title/Summary/Keyword: High Volume Operation

Search Result 333, Processing Time 0.021 seconds

A Study on the Rotation Accuracy According to Unbalance Variation of High Precision Spindle Unit for Machine Tool (고정밀 회전체의 불평형 변동에 따른 회전정밀도 영향에 관한 연구)

  • Kim, Sang-Hwa;Kim, Byung-Ha;Jin, Yong-Gyoo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.174-181
    • /
    • 2012
  • The spindle unit is a core part in high precision machine tool. Rotation accuracy of spindle unit is needed for high dignity cutting and improving the performance of machine tool. However, there are many factors to effect to rotational error motion(rotation accuracy). This study studied how rotational error motion is variation when unbalance amount is variation. Rotation accuracy of initial spindle unit is decided depending on parts and assembly such as bearing. When it is rotation, vibration and noise is appeared depending on volume of unbalance amount, so it works to decrease unbalance amount. The purpose of the study tests that unbalance amount how much effects to initial rotation condition. The result of the study shows that accuracy of parts and assembly is highly necessary to reach high rotation accuracy and unbalance amount hardly effects to initial rotation accuracy. However, it shorten spindle's life because vibration and noise is increasing by increasing unbalance amount and we can expect situation that rotation accuracy is falling by long time operation.

Reliablity of Distributed Feedback Laser Diodes for High-speed Optical Communication Systems (고속 광통신 시스템용 비대칭 분포귀환형 레이져 다이오드의 신뢰성에 관한 연구)

  • Jeon, Su-Chang;Joo, Han-Sung;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.96-99
    • /
    • 2005
  • As the demand of internet networks using backbone communication systems recently increased, the researches on the high-speed wideband optical communication systems are required. For high-speed optical communication systems, asymmetric sampled grating distributed feedback laser diodes (DFB-LDs) are developed and the reliability of DFB-LDs is examined. The reliability of DFB-LDs is performed by monitoring I-V and L-I characteristics and two degradation phenomena related to the electrical characteristics of LDs are observed during the life tests. The first degradation phenomenon by increasing the reverse current is considered as a formation of leakage current path enough to prevent lasing operation in lateral blocking layer near active region of lasers. The second degradation phenomenon by decreasing the forward current is considered as activation of non-radiative Auger recombination process by thermal energy and the second degradation phenomenon is recovered after the off-test period at room temperature Eventually, evaluating the reliability of DFB LDs can allow us to improved the manufacturability in high-volume manufacturing.

  • PDF

SHIELDED LASER ABLATION ICP-MS SYSTEM FOR THE CHARACTERIZATION OF HIGH BURNUP FUEL

  • Ha, Yeong-Keong;Han, Sun-Ho;Kim, Hyun-Gyum;Kim, Won-Ho;Jee, Kwang-Yong
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.311-318
    • /
    • 2008
  • In modem power reactors, nuclear fuels have recently reached 55,000 MWd/MtU from the initial average burnup of 35,000 MWd/MtU to reduce the fuel cycle cost and waste volume. At such high burnups, a fuel pellet produces fission products proportional to the burnup and creates a typical high burnup structure around the periphery region of the pellet, producing the so called 'rim effect'. This rim region of a highly burnt fuel is known to be ca. $200\;{\mu}m$ in width and is known to affect the fuel integrity. To characterize the local burnup in the rim region, solid sampling in the micro meter region by laser ablation is needed so that the distribution of isotopes can be determined by ICP-MS. For this procedure, special radiation shielding is required for personnel safety. In this study, we installed a radiation shielded laser ablation ICP-MS system, and a performance test of the developed system was conducted to evaluate the safe operation of instruments.

High Efficiency and Small Size Switch Mode Line Transformer(SMLT) (고효율 및 소형 스위치모드 라인 트랜스포머)

  • Kim, Jin-Hong;Yang, Jung-Woo;Jang, Du-Hee;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.237-243
    • /
    • 2019
  • A high-efficiency and small-sized switched-mode line transformer (SMLT) is proposed in this study. The conventional structure of an adapter is composed of line transformer and rectifiers. This structure has a limit in miniaturizing due to low-frequency line transformer. Another structure is composed of power factor correction (PFC) and DC/DC converter. This structure has a limit in reducing volume due to two-stage structure. As the proposed SMLT is composed of an LLC resonant converter, a high-frequency transformer can be adopted to achieve isolation standards and size reduction. This proposed structure has different operation modes in accordance with line input voltage to overcome poor line regulation. In addition, the proposed SMLT is applied to the front of a conventional PFC converter, because the SMLT output voltage is restored to rectified sinusoidal wave by using a full-bridge rectifier in the secondary side. The design of the PFC converter is easy, because the SMLT output voltage is controlled as rectified sinusoidal wave. The validity of the proposed converter is proven through a 350 W prototype.

A Study on an Image Processing for Segmentation of Liver Arteriography Using Medical Image(MDCT) (의료명상(MDCT)을 이용한 간 동맥의 영역 분할에 관한 영상처리)

  • Choi Seung-Kwon;Cho Yong-Hwan;Lee Byong-Rok
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.305-305
    • /
    • 2005
  • In modern society, diseases are variously found. Also, disease can be fatal once starting attack or one misses the proper medical examination time. According to the development of society, our liver settled on exhausted status which causes high disease development ratio because of excess business, smoking and drinking. Especially liver related disease cannot be recovered, therefore it depends on internal organ transplant surgery. In this paper, calculate volume from rendered liver shape using 3-dimensional image processing method and we develop an image processing method for the image acquired by MDCT, that can simulate incision line decision according to blood vessel segmentation that can be used on liver transplant operation. Simulation results which adopt automatic liver segment abstraction algorithm show that it can help surgical operation.

The Current State of and Barriers to Quality Measurement, and Quality Managers' Reported Evaluation on Quality Indicators in Korea (국내 질 향상부서 중심의 질 지표 측정 현황, 장애요인과 평가)

  • Hwang Jee-In
    • Health Policy and Management
    • /
    • v.15 no.4
    • /
    • pp.26-45
    • /
    • 2005
  • The purposes of this study were to Identify the .level of measurement on quality Indicators and evaluate the existing indicators in order to determine the priority of quality indicators' application in Korean general hospitals. A survey was conducted using a questionnaire. The subjects were quality managers working at general hospital having over 300 beds. The criteria were relevance, reliability, precision, impact, application, and preference to evaluate quality indicators. According to these six criteria, each indicator was evaluated on a five point scale(5: excellent, 1: poor). The response rate was $40.4\%$. The hospitals have monitored the average of 3.8 indicators(median 4). The indicators such as return to operating room, unplanned readmission, cancellation of booked operations, death, hospital infection, cesarean section rate, volume per disease or procedure, readmission, re-operation, blood transfusion, and post-procedural complications were frequently measured. The top ten quality indicators in the evaluation by its relevance, validity, reliability, impact, preference and application were decubitus ulcer, clean wound infection, fall, unplanned return to operation room, transfusion reactions, foreign body left In during procedure, unplanned readmission, wound infection after contaminated surgery, postoperative hemorrhage/hematoma, and cesarean section rate in order. The high priority quality indicators frequently measured could be used as primary national indicators. Standardized guidelines about monitoring indicators and the utilization will preliminarily be needed to compare and reuse the data for various purposes and improve the quality of care continuously.

Sensorless Scheme for Interior Permanent Magnet Synchronous Motors with a Wide Speed Control Range

  • Hong, Chan-Hee;Lee, Ju;Lee, Dong-Myung
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2173-2181
    • /
    • 2016
  • Permanent magnet synchronous motors (PMSMs) have higher torque and superior output power per volume than other types of AC motors. They are commonly used for applications that require a large output power and a wide range of speed. For precise control of PMSMs, knowing the accurate position of the rotor is essential, and normally position sensors such as a resolver or an encoder are employed. On the other hand, the position sensors make the driving system expensive and unstable if the attached sensor malfunctions. Therefore, sensorless algorithms are widely researched nowadays, to reduce the cost and cope with sensor failure. This paper proposes a sensorless algorithm that can be applied to a wide range of speed. The proposed method features a robust operation at low-speed as well as high-speed ranges by employing a gain adjustment scheme and intermittent voltage pulse injection method. In the proposed scheme the position estimation gain is tuned by a closed loop manner to have stable operation in tough driving environment. The proposed algorithm is fully verified by various experiments done with a 1 kW outer rotor-type PMSM.

Urinary bladder rupture during voiding cystourethrography

  • Lee, Kyong-Ok;Park, Se-Jin;Shin, Jae-Il;Lee, Suk-Young;Kim, Kee-Hyuck
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.5
    • /
    • pp.181-184
    • /
    • 2012
  • Voiding cystourethrography (VCUG) is a commonly performed diagnostic procedure for the evaluation of vesicoureteral reflux with urinary tract infection or congenital renal diseases in children. The procedure is relatively simple and cost-effective, and complications are very rare. The iatrogenic complication of VCUG range from discomfort, urinary tract infection to bacteremia, as well as bladder rupture. Bladder rupture is a rare complication of VCUG, and only a few cases were reported. Bladder rupture among healthy children during VCUG is an especially uncommon event. Bladder rupture associated with VCUG is usually more common in chronically unused bladders like chronic renal failure. Presented is a case of bladder rupture that occurred during a VCUG in a healthy 9-month-old infant, due to instilled action of dye by high pressure. This injury completely healed after 7 days of operation, and it was confirmed with a postoperative cystography. The patient's bladder volume, underlying disease, velocity of the contrast media instilled, catheter size, and styles of instillation are important factors to prevent bladder rupture during VCUG. Management of bladder rupture should be individualized, but the majority of infants are treated with the operation. In conclusion, bladder rupture is a rare complication, however, delicate attention is needed in order to prevent more dire situations.

A study on Development and Application of Sequential Control Algorithm of Ventilation and Air Cleaning System for Improving Indoor Air Quality in School Classroom (학교교실의 실내공기질 개선을 위한 환기장치 및 공기청정기의 연동제어 알고리즘 개발 및 적용 연구)

  • Park, Hwan-Chul;Lee, Dong-Hyeon;Yee, Jurng-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.187-194
    • /
    • 2020
  • This study presents the energy-saving sequential control algorithm to handle indoor CO2 and PM2.5 for the improvement of the air quality of school classrooms. To solve indoor air quality (IAQ) problems, air cleaning and ventilation systems are mainly used for school classrooms. Although air cleaning is able to collect PM2.5, it is difficult to remove harmful gas substances. The ventilation system is suitable to tackle CO and CO2, the volume ventilation, however, is relatively small. In this paper, to remove CO2 and PM2.5, the pollutant balance equation for improving indoor air quality is reviewed. The sequential control algorithm of the ventilation and air cleaning system with four levels of criteria is introduced for the effective removal of pollutants. The proposed sequential control algorithm confirms that indoor CO2 and PM2.5 can be properly controlled below the standard value. In addition, the sequential operation of air cleaning and ventilation systems has shown significant improvement in IAQ compared to the independent ventilation system operation. Particularly, such systems are efficient when outdoor PM2.5 is high.

Short-Term Prediction Model of Postal Parcel Traffic based on Self-Similarity (자기 유사성 기반 소포우편 단기 물동량 예측모형 연구)

  • Kim, Eunhye;Jung, Hoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.4
    • /
    • pp.76-83
    • /
    • 2020
  • Postal logistics organizations are characterized as having high labor intensity and short response times. These characteristics, along with rapid change in mail volume, make load scheduling a fundamental concern. Load analysis of major postal infrastructures such as post offices, sorting centers, exchange centers, and delivery stations is required for optimal postal logistics operation. In particular, the performance of mail traffic forecasting is essential for optimizing the resource operation by accurate load analysis. This paper addresses a traffic forecast problem of postal parcel that arises at delivery stations of Korea Post. The main purpose of this paper is to describe a method for predicting short-term traffic of postal parcel based on self-similarity analysis and to introduce an application of the traffic prediction model to postal logistics system. The proposed scheme develops multiple regression models by the clusters resulted from feature engineering and individual models for delivery stations to reinforce prediction accuracy. The experiment with data supplied by main postal delivery stations shows the advantage in terms of prediction performance. Comparing with other technique, experimental results show that the proposed method improves the accuracy up to 45.8%.