• 제목/요약/키워드: High Tibial Osteotomy (HTO)

검색결과 10건 처리시간 0.026초

근위골절술을 위한 Staple 설계 (A Newly Designed Miniplate Staple for High Tibial Osteotomy)

  • 문무성;배대경
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.19-22
    • /
    • 1995
  • A biomechanical study was made to demonstrate the superior mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy(HTO). Using twenty fresh porcine tibiae, the fixational strengh of the two different types of staple in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with a bone densitometry (Dual photon absorptionometer, Luner, USA) and those with $0.8\;{\sim}\;1.2\;gm/cm^2$ at the proximal tibia was used in the biomechanical test. Testing was performed on a material testing system (Autogram ET-5, Shimatzu, Japan) with aid of a commercial data processor (IBM 80386/ ASYST). Using two differant loading modes, 'pull-out' and 'push-out', the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten non-osteotomized specimens were used and the staple was pullout by subjecting an axial tension on the head of the staple inserted. While in the pull-out test where ten tibiae osteotomized in the usual way of HTO were used, the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the distal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the proximal tibia was fixed. The pull-out strength of Coventry staple and miniplate staple were found to be $27.88\;{\pm}\;5.12\;kgf$ and $182.47\;{\pm}\;32.75\;kgf$, respectively. The push-out strength of Coventry staple and miniplate staple were $18.40\;{\pm}\;4.47\;kgf$ and $119.95\;{\pm}\;19.06\;kgf$, respectively. The result revealed that miniplate staple had the pull-out/ push-out strength at least fivetimes higher than Coventry staple. Based on the measured data, it was believed that the newly designed miniplate staple could provide much better postoperative fixation in HTO. The postoerative application of long leg casting may not be needed after HTO surgery.

  • PDF

근위 경골 절골술 후 한방 재활치료 프로토콜을 적용한 재활치료의 임상적 효과: 증례 보고 (A Rehabilitation Protocol for High Tibial Osteotomy in Korean Medicine: A Report of 3 Cases)

  • 금지혜;하원배;고낙용;이정한
    • 한방재활의학과학회지
    • /
    • 제28권3호
    • /
    • pp.107-118
    • /
    • 2018
  • In this study, we propose a rehabilitation protocol involving Korean medicine for patients after high tibial osteotomy (HTO) and report its effectiveness. Three patients underwent HTO using the rehabilitation protocol involving Korean medicine. We estimated the outcome evaluating physical examination findings of the knee joint, numeric rating scale, pain disability index, Lysholm knee score, and walking state. After the treatment, we observed that knee movement and muscular strength were improved. In addition, the numeric rating scale, pain disability index, Lysholm knee score, and walking state of patients were improved. Therefore, a rehabilitation protocol involving Korean medicine can be effectively used for patients after HTO. The limitation of this study was the insufficient number of cases and the difficulty of follow-up because of the characteristics of this operation and the long periods of time that are needed for each phase of the protocol. Further studies are needed to design a rehabilitation protocol involving Korean medicine.

Computer Assisted Surgery(CAS)를 이용한 개방형 근위경골절골술 시 전내측피질골경사각이 경골후방경사각에 미치는 영향 (Effect of Anteromedial Cortex Oblique Angle on Change of Tibial Posterior Slope Angle in High Tibial Osteotomy Using Computer Assisted Surgery (CAS))

  • 이호상;김재정;왕준호;김철웅
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.351-361
    • /
    • 2012
  • 슬관절 내반슬과 외반슬의 부정정렬을 교정하는 방법 중 대표적인 수술법이 근위경골절골술이다. 개방형 쐐기 근위경골절골술(OWHTO)의 경우 근위비골 인접부의 경골외측 비골신경을 손상시킬 우려가 없고, 수술도중 교정각의 개방 정도를 임의대로 조절 변경 가능한 장점으로 최근 선호되고 있다. 그러나 술후 관상면에서의 외반 및 내반 교정은 바르게 이루어지는 반면, 시상면에서는 수술자가 의도하지 않은 경골내측고평부의 후방경사각(PSA) 변화가 발생한다는 문제점이 있다. 저자들은 이와 같은 문제의 극복을 위해 Computer Assisted Surgery를 이용한 근위경골절골술 기법을 자체적으로 개발하였고, 근위경골부의 CT 이미지 3차원 재건과 컴퓨터를 이용한 가상절골술을 수행하였다. 또한 술후에도 후방경사각(PSA)이 변화하지 않는 수술기법에 대해 제시하였다. 본 연구결과는 환자고유의 전내측피질골 경사각(ACOA)과 후방경사각(PSA)의 명확한 관계성에 대해 제시해줄 것이며 환자마다 다른 최적의 후방경사각 결정법에 대해 제시해 줄 것으로 판단된다.

Tracking-Pin과 Fluoroscopic G-arm 이미지를 이용한 경골근위부절골술 지원시스템 개발 (Development of Computer-Aided Surgery System for High Tibial Osteotomy Using Tracking-Pin and Fluoroscopic G-arm Images)

  • 구본열;김철웅;이순혁;배지훈;박철우;김재정
    • 한국CDE학회논문집
    • /
    • 제16권5호
    • /
    • pp.331-343
    • /
    • 2011
  • High tibial osteotomy (HTO) is a widely accepted treatment for unicompartmental osteoarthritis of the knee and other lower extremity deformities, particularly for young and active patients. However, it is generally recognized as a technically demanding procedure. Thus the limitations of conventional surgical methods have been reported. Currently, the use of computer-aided surgery (CAS) system for successful surgery was increased. However it has been reported many problems such as expensive equipment, infection or fracture caused by inserting half-pin and delaying surgery. Therefore we propose a novel method which can be tracked by using tracking-pin inserted in arbitrary locations of the femur and tibia, and fluoroscopic images obtained from G-arm of antero-posterior and lateral-medial.

Short-Term Results of Hybrid Closed-Wedge High Tibial Osteotomy: A Case Series with a Minimum 3-Year Follow-up

  • Saito, Hidetomo;Saito, Kimio;Shimada, Yoichi;Yamamura, Toshiaki;Yamada, Shin;Sato, Takahiro;Nozaka, Koji;Kijima, Hiroaki;Miyakoshi, Naohisa
    • Knee surgery & related research
    • /
    • 제30권4호
    • /
    • pp.293-302
    • /
    • 2018
  • Purpose: High tibial valgus osteotomy (HTO) is a well-established surgical procedure for patients with medial compartment osteoarthritis (OA) of the knee. The hybrid closed-wedge HTO (CWHTO) procedure permits extensive correction in patients with severe deformities or patellofemoral joint OA. The aim of this study was to report the short-term results in a consecutive series of patients treated with hybrid CWHTO. Materials and Methods: We retrospectively evaluated the clinical outcomes and radiographic parameters in 29 consecutive knees that underwent hybrid CWTHO to correct medial compartment OA at an average follow-up of 52.6 months. Clinical outcomes were assessed using the Lysholm score and knee scoring system of the Japanese Orthopedic Association (JOA). The Kellgren-Lawrence grading system and pre- and postoperative mechanical axis (MA), femorotibial angle (FTA), posterior tibial slope, and patella height were assessed. Results: The FTA and MA significantly changed from $180.7^{\circ}$ to $170.4^{\circ}$ and from $22.0^{\circ}$ to $60.2^{\circ}$, respectively. No significant differences were observed between the mean pre- and postoperative posterior tibial slope, Insall-Salvati ratio, or Caton-Deschamps index. The postoperative JOA and Lysholm scores significantly improved from 76.7 to 95.8 and from 58.8 to 90.2, respectively. Conclusions: Satisfactory outcomes can be achieved with hybrid CWHTO in patients with medial OA.

내측개방형 근위경골절골술의 경골절단면 및 경골개방축의 설정에 따른 영향 (Effect of Tibial Cut Planes and Hinge Axes on Medial Opening Wedge High Tibial Osteotomy)

  • 박병건;이호상;김재정;김철웅
    • 대한기계학회논문집A
    • /
    • 제35권8호
    • /
    • pp.835-846
    • /
    • 2011
  • 최근 보편화 되고 있는 내측개방형절골술 시에 의도하지 않은 경골후방경사각의 변화로 인한 문제점들이 보고되었다. 이를 해결하기 위해 많은 연구들이 진행되어 왔지만 환자의 다양한 경골의 형상 및 절단면의 기울기에 적용될 수 있는 일반적 해석 모델은 아직 제안되지 못하고 있다. 따라서 본 논문에서는 일반적인 케이스에 적용할 수 있는 근위경골절골술의 해석 모델을 제안한다. 이를 위해 내반교정각만을 조정할 수 있는 가상경골축을 정의하고, 이를 통해 절단면과 경골개방축이 내반교정각에 주는 영향을 나타내는 수학적 모델을 제안하고, 기존의 수술적인 변수들간의 상관관계를 명확히 나타내었다. 또한 내반교정각과 경골후방경사각에 추가로, 새로운 각도인 경골뒤틀림각의 존재를 도입함으로써 수술 시 발생하는 모든 기하학적 변수들간의 관계를 완성된 형태로 표현하였다.

내반 변형을 지닌 내측 반월상 연골판 후방 골 기시부 퇴행성 파열 환자에서 반월상 연골판 절제술 단독과 근위 경골 절골술 동반 수술의 결과 비교 (The comparative study of arthroscopic meniscectomy with or without high tibial osteotomy in patients with degenerative medial meniscus posterior horn tear)

  • 문재영;선종근;송은규;김형순;임지현;조현종
    • 대한정형외과스포츠의학회지
    • /
    • 제11권1호
    • /
    • pp.30-36
    • /
    • 2012
  • 목적: 내반 변형을 지닌 내측 반월 연골판 후방 골 기시부 퇴행성 파열 환자에 대해 관절경적 반월 연골판 절제술을 시행 중 개방형 경골 근위부 절골술을 시행하는 경우와 하지 않는 경우에서의 임상적 및 방사선학 결과를 비교 하고자 하였다. 대상 및 방법: $3^{\circ}$ 이상 내반 변형과 내측 반월 연골판 후방 골 기시부 퇴행성 파열을 지닌 환자에 대해 관절경적 반월 연골판 절제술을 시행받고, 최소 3년 이상 추시가 가능한 환자 42명을 대상으로 하였다. 그 중 30명에 대해서는 개방형 근위 경골 절골술을 함께 시행하였으며, 나머지 12명에 대해서는 반월 연골판 절제술만 시행하였었다. 평균 추시 시간은 52.5개월 (36.0~76.6)이었다. 최종 추시 상 두 군간에 수술 전 증상의 소실 유무, 수술에 대한 환자의 만족도, 및 HSS 점수에 대한 임상적 결과를 비교하였다. 또한 최종 추시 상 방사선학적 퇴행성 관절염의 진행 유무를 비교하였다. 결과: 증상의 호전은 근위 경골 절골술을 함께 시행한 군(83.3%, 25예)에서 의의있게 관절경적 반월 연골판 부분 절제술만을 시행한 군(66.7%, 8예)보다 호전을 보였다. 환자 만족도 역시 근위 경골 절골술을 함께 시행한 군(83.3%, 25예)에서 반월상부분 절제술만 시행한 군(58.3%, 7예)보다 의의있게 높게 나타났다. HSS 점수는 근위 경골 절골술을 같이 시행한 군은 술 전 56.9점에서 술 후 90.8점으로 향상되었으며, 반월 연골판 부분 절제술만을 시행한 군에서는 술 전 67.9점에서 술 후 89.0점으로 향상되었으나, 양군간의 통계학적 차이는 관찰할 수 없었다. WOMAC 점수 역시 양군간의 통계학적 차이는 관찰할 수 없었다. 최종 추시 상 방사선학적 퇴행성 관절염의 진행에 있어서 두 군간에 의의 있는 차이는 없었다. 결론: 내반 변형을 지닌 반월 연골판 후방 골 기시부 퇴행성 파열 환자의 치료에 있어 좋은 임상적 결과를 위해서는 근위 경골절골술이 반드시 필요할 것으로 생각된다. 그러나 퇴행성 관절염의 결과에 미치는 영향에 대해서는 장기적인 추시가 필요할 것으로 생각된다.

  • PDF

근위경골절골술(HTO)용 X-밴드 플레이트에 적용되는 고밀도 폴리에틸렌(HDPE)의 변형률속도에 따른 점탄성거동 (Viscoelastic Behavior of High Density Polyethylene Using High Tibial Osteotomy with Respect to the Strain Rate)

  • 황정훈;김철웅
    • 대한기계학회논문집B
    • /
    • 제36권4호
    • /
    • pp.431-438
    • /
    • 2012
  • 고밀도 폴리에틸렌(HDPE)과 같은 고분자재료의 기계적 거동은 시간과 온도에 의존적이다. 따라서 근위경골절골술(HTO)용 X-밴드 플레이트에 적용되는 HDPE의 각기 다른 변형률속도에 따른 인장거동에 대한 연구는 매우 중요하다. 일반적으로 엔지니어링 응력-변형률곡선에 기반을 둔 폴리메트릭 물질의 변형거동은 입자넥킹의 소성변형을 동반한 높은 비균질성을 나타내므로 매우 복잡한 거동을 나타낸다. 본 연구에서는 1~500%/min의 9가지 변형률속도를 적용하여 그에 따른 점탄성 거동을 평가하였다. 그 결과, 저속 변형률속도에서는 최대인장응력이 증가하고 변형률은 감소하였으나 고속 변형률속도에서는 점탄성거동이 급변하는 교차점(Ts)이 발생하였다. 또한 전이점($P_{st}$)에 의해 구해진 전이응력(${\sigma}_{ts}$)은 고속 변형률속도에서 최대인장응력(${\sigma}_{ult}$)보다 저하됨을 관찰할 수 있었고, 초기 모듈러스와 전이점에서의 시컨트 모듈러스의 비인 ${\beta}$를 이용하여 저속과 고속 변형률속도에서의 점탄성 거동을 평가한 결과 고속 변형률속도에서 급격한 ${\beta}$의 증가를 관찰할 수 있었다.