Abstract
The mechanical behavior of the polymeric material, HDPE depends on both time and temperature. The study of the tensile behavior at different strain rates is important in engineering design of the orthopedics device such as X-band plate. The mechanical properties and deformation mechanisms of HDPE are strongly dependent on the applied strain rate. Generally, the deformation behavior of HDPE based on the stress-strain curve is complex because of the highly inhomogeneous nature of plastic deformation, particularly that of necking. Therefore, we attempted to determine the mechanical behavior of HDPE in this study. Normally, tensile testing under various strain rates of the HDPE has been used to determine the mechanical behavior. We performed tensile tests at various strain rates (1 to 500 %/min) to analyze the viscoelastic behavior on increasing the strain rate. A tensile stress-strain curve was plotted from the data, and the point of transition was marked to calculate the transition stress, strain, and modulus.
Keywords
High Density Polyethylene(HDPE); Strain Rate; Transition Stress; Secant Modulus; Viscoelastic Behavior; High Tibial Osteotomy(HTO);
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Wang, J. H., Bae, J. H., H. Lim, C., Shon, W. Y., Kim, C. W. and Cho, J. W., 2009, "Medial Open Wedge High Tibial Osteotomy: The Effect of the Cortical Hinge on Posterior Tibial Slope," The American Journal of Sports Medicine, Vol. 37, No. 12, pp. 2411-2418.   DOI   ScienceOn
2 Noyes, F. R., Goebel, S. X. and West, J., 2005, "Opening Wedge Tibial Osteotomy : The 3-Triangle Method to Correct Axial Alignment and Tibial Slope," The American Journal of Sports Medicine, Vol. 33, No. 3, pp. 378-387.   DOI
3 Song, E. K., 2004, "High Tibial Osteotomy for Osteoarthritis of the Knee," J. of Korea Orthop. Assoc., Vol. 39, No. 1, pp. 104-107.   과학기술학회마을
4 Yoo, J. H., Chang, C. B., Shin, K. S., Seong, S. C. and Kim, T. K., 2008, "Anatomical Reference to Assess the Posterior Tibial Slope in Total Knee Arthroplasty : A Comparison of 5 Anatomical Axes," The Journal of Arthroplasty, Vol. 23, No. 4, pp. 586-592.   DOI   ScienceOn
5 Zhil'tsova, T. V., Oliveira, M. S. A. and Ferreira, J. A. F., 2009, "Relative Influence of Injection Molding Processing Conditions on HDPE Acetabular Cups Dimensional Stability," Journal of Materials Processing Technology 209, pp. 3894-3904.   DOI   ScienceOn
6 Merry, S. M. and Bray, J. D., 1997, "Time-dependent Mechanical Response of HDPE Geomembranes," J. Geotechnical & Geoenvironmental Engineering, Vol. 123, No. 1, pp. 57-64.   DOI   ScienceOn
7 Dusunceli, N. and Colak, O. U., 2008, "The Effects of Manufacturing Techniques on Viscoelastic and Viscoplastic Behavior of High Density Poly ethylene (HDPE)," Materials and Design, Vol. 29, pp. 1117-1124.   DOI   ScienceOn
8 Elleuch, R. and Taktak, W., 2006, "Viscoelastic Behavior of HDPE Polymer using Tensile and Compressive Loading," JMEPEG, Vol. 15, pp. 111-116.   DOI   ScienceOn
9 Roylance D., 2001, "Open Lecture : Engineering Viscoelasticity," Department of Materials Science and Engineering Massachusetts Institute of Technology, Cambridge, MA 02139.
10 Beijer, J. G. J. and Spoormaker, J. L., 2000, "Modelling of Creep Behavior in Injection-moulded HDPE," Polymer, Vol. 41, pp. 5443-5449.   DOI   ScienceOn
11 Wesseloo, J., Visser, A. T. and Rust, E., 2004, "A Mathematical Model for the Strain-rate Dependent Stress-strain Response of HDPE Geomembranes," Geotextile and Geomembranes, Vol. 22, pp. 273-295.   DOI   ScienceOn