• Title/Summary/Keyword: High Temperature Region

검색결과 1,516건 처리시간 0.046초

고온.고압 환경에서 가열평판에 충돌하는 디젤분무의 특성 (Characteristics of Impinging Diesel Spray on the Heated Flat Wall in High Temperature and High Pressure Environments)

  • 임경훈;이봉수;김종현;구자예
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.627-633
    • /
    • 2001
  • Characteristics of a diesel spray impingement with the variation of ambient temperature, wall temperature and ambient pressure were investigated through shadowgraphy method by using high speed camera. The radial penetration of spray was increased with ambient temperature and wall temperature. It is resulted from the decrease of ambient gas density caused by the increase of temperature. The height of spray was also increased with ambient temperature and wall temperature, because the height of stagnate region is noticeably increased, although height of wall jet vortex is decreased. At the same ambient pressure, the area ratio of impinging spray of room temperature environment to high temperature environment was increased, as the temperature difference between room temperature and high temperature increases. And the increment of area ratio was higher at low ambient pressure than high ambient pressure.

정적 예혼합기 연소에 있어서 2영역 모델 및 2색법에 의한 연소온도 비교에 관한 연구 (A Study on Comparisons Between Combustion Temperatures Calculated by Two-Region Model and Measured by Two-Color Method in Premixed Constant-Volume Combustion)

  • S.K.Lee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.300-310
    • /
    • 1999
  • A constant-volume combustion chamber is developed to measure the burnt gas temperature over the wide ranges of equivalence ratio from 1.5 to 2.7 and pressure from 0.1 to 2.7 and pressure from 0.1 to 6 MPa by two-color method. The combustion temperature is also calculated by the conventional two-region model. The premixed fuel rich propane-oxygen-inert gas mixtures under high pressures are simultaneously ignited by eight spark plugs located on the circumference of combustion chamber with 45 degree intervals. The eight converging flames compress the end gases to high pressures. The transmissiv-ity in the chamber center during the final stage of combustion at the highest pressure is measured by in situ laser extinction method. Comparisons are made with the combustion temperatures between two-color method and two-region model. It is found that the burnt gas temperature mea-sured by two-color method is higher than that calculated by two-region model because of being the negative temperature gradient on the calculation and the temperature distribution of light path-length on the measurement and the burnt gas temperature for the turbulent combustion is higher than that of the laminar combustion under the same conditions because the heat loss for turbulent combustion is lower due to the shorter combustion period.

  • PDF

NiO-$Y_2O_3$계의 전기전도성 (Electrical Conductivity of the System NiO-$Y_2O_3$)

  • 최재시;김규홍;정원양
    • 대한화학회지
    • /
    • 제30권1호
    • /
    • pp.27-32
    • /
    • 1986
  • 0.8, 1.6 및 3.2 mol%의 산화니켈을 혼입한 산화니켈-산화이트륨계의 전기전도도를 1 ${\times} 10^{-5}$ ~ 2 ${\times}10^{-1}$ atm의 산소압력과 400 ~ 1100$^{\circ}$C의 온도영역에서 산소압력 및 온도의 함수로서 측정하였다. 전기전도도의 온도의존성은 약 650$^{\circ}$C부근에서 두 영역으로 나뉘었으며, 650$^{\circ}$C이하 영역보다 650$^{\circ}$C이상 영역에서의 온도의존성이 더 큰 것으로 밝혀졌다. 평균 활성화에너지는 650$^{\circ}$C이상 영역에서 41.8kcal/mol, 650$^{\circ}$C이하 영역에서 12.5kcal/mol이다. 산소압력의존성, 1/n값은 650$^{\circ}$C이상 영역에서는 1/5.1~1/5.4이며, 650$^{\circ}$C이하에서는 1/5.9~1/6.2이다. NiO-$Y_2O_3$계는 결함구조가 고온영역에서 3가로 이온화한 이트륨공위이며, 저온영역에서는 2가로 이온화한 틈새형 산소 인전자성 p-형 반도체임이 밝혀졌다. 그러나, 저온영역에서는 이온성 전기전도에 의한 기여가 어느 정도 존재하는 것으로 밝혀졌다.

  • PDF

방사선 열화에 따른 이축연신 폴리프로필렌 필름의 유전특성 (The Dielectric Properties of OPP film due to Irradiation Aging)

  • 오세원;조경순;김용주;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 추계학술대회 논문집
    • /
    • pp.80-84
    • /
    • 1993
  • In this research, we studied the variation of the dielectric loss absorption of the dielectric loss absorption of the sample according with the change to $\^$60/Co-${\gamma}$-ray irradiation dose of the influence of temperature and applied voltage. In order to investigate the effect of irradiation oriented polypropylene film, we have observed dissipation factor within the temperature range of 30∼130 [$^{\circ}C$] and voltage range of 100∼250$^{\circ}C$ [V]. As for the dependency of temperature by dissipation factor, the ${\alpha}$-peak which appears at high temperature increases accordingly to the increasement of irradiation dose which is contributed by the crystal region and moves towards the high temperature. The ${\beta}$-peak which appears at low temperature is origined from dipoles and molecular motions in the amorphous region. As for the dependency of voltage by tan$\delta$, at low temperature the peak of the tan$\delta$, at low temperature the peak of the tan$\delta$ shifts accordingly to the increasement of irradiation dose towards the high temperature region.

  • PDF

Vertical Temperature Profile in the Yellow Sea according to the Variations of Air Temperature

  • CHO Kyu-Dae;CHO Kwang-Woo
    • 한국수산과학회지
    • /
    • 제21권1호
    • /
    • pp.1-10
    • /
    • 1988
  • The vertical temperature profiles of the Yellow Sea in summer are investigated by means of the nine air temperature (AT) patterns which are classified with the AT of winter and summer. The sea surface temperature (SST) is high when the AT of summer is high, and vice versa. The gradient of thermocline in the offshore region is higher than that in the coastal region and is not always favorable with the AT patterns. The relation between sea bottom temperature (SBT) and the AT of winter is favorable when the SBT is averaged in the coastal and offshore stations. In addition, the SST of coastal stations is higher than that of offshore stations because of the strong mixing by the tidal current in the coastal region. The correlation between the AT and the SST of August is favorable (r=0.44-0.69), while the correlation between the AT of February and the SBT of August is not favorable except the stations, A2 (r=0.57) and B2 (r=0.61).

  • PDF

점도증가에 따른 절연용 실리콘유의 유전손실 (Dielectric loss of silicone oils for insulation due to the increase of viscosity)

  • 이용우;조경순;김왕곤;홍진웅
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.587-593
    • /
    • 1995
  • Silicone oils used insulating substances exhibit the both of organic and inorganic properties, and it has many superior characteristics such as the high thermal resistance and low thermal oxidation level when compared to other insulation oils. In order to investigate the dielectric loss due to the increase of viscosity, silicone oils of viscosity 1, 2, 5[cSt] had been chosen as the specimen and experiment has been performed in the temperature range of -70[.deg. C] - 65[.deg. C] and frequency range of 30 - 1*10$\^$5/[Hz]. As a result, the linear decrease of loss at low frequency region in high temperature was due to the influence of applying frequency, whereas the increase of loss at high frequency region was contributed by electrode's resistance. And increasing viscosity, the activation energy increased from 3.77[kcal/mole] to 7.21[kcal/mole]. The dipole moment of specimen was become clear 1.48 - 2.26[debyel in high temperature region(5 - 65[.deg. C]) and 1.05 - 1.80[debye] in low temperature region (-70 - -25[.deg. C])respectively.

  • PDF

에폭시 나노컴퍼지트 체적 고유저항의 온도 의존성 (Temperature Dependence of Volume Resistivity on Epoxy Nano-composites)

  • 김창훈;이영상;강용길;박희두;신종열;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.834-838
    • /
    • 2011
  • This research shows the electrical characteristic using excellent epoxy nano-composite of MgO 5.0 wt% and $SiO_2$ 0.4 wt% in mechanical strength test depending on nano-additive. First of all, volume resistance depending on nano-additive and temperature using high resistance meter (HP. 4329A) by increasing 10, 100, 1,000 V of applying voltage was measured. Moreover, temperature range of $25{\sim}120^{\circ}C$ with virgin sample was tested using TO-9B oven by Ando Company. The result showed that virgin and the samples added with MgO and $SiO_2$ had similar value of volume resistance in low temperature and low electric field region and reduced with slow slope. The nano-composite's volume resistance of sample added with MgO and $SiO_2$ had higher value than virgin sample's volume resistance in high temperature region more than $80^{\circ}C$. Moreover, the slope has steeply reduced. The volume resistance of sample added with MgO 5.0 wt% was $8.38{\times}10^{13}\;{\Omega}{\cdot}cm$ and it was 6.8 times more than virgin sample in high temperature at $120^{\circ}C$. The insulation characteristics were constant although filler has changed in low temperature region. But, in high temperature region, the value of volume resistance of sample with MgO 5.0 wt% was 7.6 times more than the virgin sample's volume resistance.

Enhancement of Hydroxylamine Reactivity of Bacteriorhodopsin at High Temperature

  • Sonoyama, Masashi;Mitaku, Shigeki
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.299-301
    • /
    • 2002
  • Recent denaturation experiments of bacteriorhodopsin (bR) in the dark and under illumination at high temperatures revealed that irreversible thermal bleaching occurs above ~ 70°C and the preceding reversible structural changes in the dark above 60°C are closely related to irreversible photobleaching observed in the same temperature range (Yokoyama et al. (2002). J Biochem. 131,785). In this study, structural properties of bacteriorhodopsin (bR) at high temperatures were extensively probed by hydroxylamine reactivity with the Schiff base in the dark and hydrogen-deuterium (H-D) exchange in the peptide groups. In the Arrhenius plot from kinetics measurements of the hydroxylamine reaction, a good linear relationship between the reaction time constant and the inverse of the absolute temperature was observed below 60°C, while significant increase started above 60°C, suggesting that remarkable increase in water accessibility of the Schiff base in the temperature region. FT-IR spectroscopic studies on the H-D exchange suggested increase in the deuterium exchanges rate of the peptide hydrogen in the same temperature region.

  • PDF

NASA 모델의 편차보정에 의한 광역지역의 지표온도산출 정확도 향상 (NASA Model Deviation Correction for Accuracy Improvement of Land Surface Temperature Extraction in Broad Region)

  • 엄대용;박준규;김민규;강준묵
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.281-286
    • /
    • 2006
  • In this study, acquired time series Landsat TM/ETM+ image to extract land surface temperature for wide-area region and executed geometric correction and radiometric correction. And extracted land surface temperature using NASA Model, and I achieved the first correction by perform land coverage category for study region and applies characteristic emission rate. Land surface temperature that acquire by the first correction analyzed correlation with Meteorological Administration's temperature data by regression analysis, and established correction formula. And I wished to improve accuracy of land surface temperature extraction using satellite image by second correcting deviations between two datas using establishing correction formula. As a result, land surface temperature that acquire by 1,2th correction could correct in mean deviation of about ${\pm}3.0^{\circ}C$ with Meteorological Administration data. Also, could acquire land surface temperature about study region by relative high accuracy by applying to other Landsat image for re-verification of study result.

  • PDF

페블 베드 타입 고온 가스 냉각 원자로 내부 유동장 측정 (Measurement of Flow Field in the Pebble Bed Type High Temperature Gas-cooled Reactor)

  • 이사야;이재영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2088-2093
    • /
    • 2008
  • In this study, flow field measurement of the Pebble Bed Reactor(PBR) for the High Temperature Gas-cooled Reactor(HTGR) was performed. Large number of pebbles in the core of PBR provides complicated flow channel. Due to the complicated geometries, numerical analysis has been intensively made rather than experimental observation. However, the justification of computational simulation by the experimental study is crucial to develop solid analysis of design method. In the present study, a wind tunnel installed with pebbles stacked was constructed and equipped with the Particle Image Velocimetry(PIV). We designed the system scaled up to realize the room temperature condition according to the similarity. The PIV observation gave us stagnation points, low speed region so that the suspected high temperature region can be identified. With the further supplementary experimental works, the present system may produce valuable data to justify the Computational Fluid Dynamics(CFD) simulation method.

  • PDF