• Title/Summary/Keyword: High Speed Imaging system

Search Result 130, Processing Time 0.025 seconds

A Real-time Vision Inspection System at a Laver Production Line (해태 생산라인에서의 실시간 시각검사 시스템)

  • Kim, Gi-Weon;Kim, Bong-Gi
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.601-604
    • /
    • 2007
  • In this paper dose a laver surface check using a real time image process. This system does false retrieval of a laver at a laver production line. At first, a laver image was read in real time using a CCD camera. In this paper, we use an area scan CCD camera. Image is converted into a binary code image using a high-speed imaging process board afterwards. A laver feature is extracted by a binary code image. Surface false retrieval is finally executed using a laver feature. In this paper, we use an area feature of a laver image.

  • PDF

A Real-time Vision Inspection System at a Laver Production Line (해태 생산라인에서의 실시간 시각검사 시스템)

  • Kim, Gi-Weon;Kim, Bong-Gi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1136-1140
    • /
    • 2007
  • In this paper dose a laver surface check using a real time image process. This system does false retrieval of a laver at a laver production line. At first, a laver image was read in real time using a CCD camera. In this paper, we use an area scan CCD camera. Image is converted into a binary code image using a high-speed imaging process board afterwards. A laver feature is extracted by a binary code image. Surface false retrieval is finally executed using a laver feature. In this paper, we use an area feature of a laver image.

Fast Noise Reduction Approach in Multifocal Multiphoton Microscopy Based on Monte-Carlo Simulation

  • Kim, Dongmok;Shin, Younghoon;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.421-430
    • /
    • 2021
  • The multifocal multiphoton microscopy (MMM) enables high-speed imaging by the concurrent scanning and detection of multiple foci generated by lenslet array or diffractive optical element. The MMM system mainly suffers from crosstalk generated by scattered emission photons that form ghost images among adjacent channels. The ghost image which is a duplicate of the image acquired in sub-images significantly degrades overall image quality. To eliminate the ghost image, the photon reassignment method was established using maximum likelihood estimation. However, this post-processing method generally takes a longer time than image acquisition. In this regard, we propose a novel strategy for rapid noise reduction in the MMM system based upon Monte-Carlo (MC) simulation. Ballistic signal, scattering signal, and scattering noise of each channel are quantified in terms of photon distribution launched in tissue model based on MC simulation. From the analysis of photon distribution, we successfully eliminated the ghost images in the MMM sub-images. If the priori MC simulation under a certain optical condition is established at once, our simple, but robust post-processing technique will continuously provide the noise-reduced images, while significantly reducing the computational cost.

Measuring Plate Thickness Using Spatial Local Wavenumber Filtering (국소 공간 웨이브넘버 필터링 기법을 이용한 평판 구조물 두께 측정)

  • Kang, To;Lee, Jeong Han;Han, Soon Woo;Park, Jin Ho;Park, Gyuhae;Jeon, Jun Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.370-376
    • /
    • 2016
  • Corrosion on the surface of a structure can generate cracks or cause walls to thin. This can lead to fracturing, which can eventually lead to fatalities and property loss. In an effort to prevent this, laser imaging technology has been used over the last ten years to detect thin-plate structure, or relatively thin piping. The most common laser imaging was used to develop a new technology for inspecting and imaging a desired area in order to scan various structures for thin-plate structure and thin piping. However, this method builds images by measuring waves reflected from defects, and subsequently has a considerable time delay of a few milliseconds at each scanning point. In addition, the complexity of the system is high, due to additional required components, such as laser-focusing parts. This paper proposes a laser imaging method with an increased scanning speed, based on excitation and the measurement of standing waves in structures. The wavenumber of standing waves changes at sections with a geometrical discontinuity, such as thickness. Therefore, it is possible to detect defects in a structure by generating standing waves with a single frequency and scanning the waves at each point by with the laser scanning system. The proposed technique is demonstrated on a wall-thinned plate with a linear thickness variation.

Acute Changes in Fascicle Behavior and Electromyographic Activity of the Medial Gastrocnemius during Walking in High Heeled Shoes

  • Kim, Jin-Sun;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.135-142
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the acute effect of walking on high heels on the behavior of fascicle length and activation of the lower limb muscles. Methods: Twelve healthy inexperienced high heel wearers (age: $23.1{\pm}2.0yr$, height: $162.4{\pm}4.9cm$, weight: $54.4{\pm}8.5kg$) participated in this study. They walked in high heels (7 cm) and barefoot on a treadmill at their preferred speed. During the gait analysis, the lower limb joint kinematics were obtained using a motion analysis system. In addition, the changes in fascicle length and the level of activation of the medial gastrocnemius (MG) were simultaneously monitored using a real-time ultrasound imaging technique and surface electromyography, respectively. Results: The results of this study show that the MG fascicle operates at a significantly shorter length in high heel walking ($37.64{\pm}8.59mm$ to $43.99{\pm}8.66mm$) in comparison with barefoot walking ($48.26{\pm}9.02mm$ to $53.99{\pm}8.54mm$) (p < .05). In addition, the MG fascicle underwent lengthening during high heel walking with relatively low muscle activation while it remained isometric during barefoot walking with relatively high muscle activation. Conclusion: Wearing high heels alters the operating range of the MG fascicle length and the pattern of muscle activation, suggesting that prolonged wearing of high heels might induce structural alterations of the MG that, in turn, hinder normal functioning of the MG muscle during walking.

Picture archiving and communications systems development and performance results

  • Nam, Ji-Seung;Ralph Martinez
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1796-1800
    • /
    • 1991
  • Picture Archiving and Communication Systems(PACS) provide an integration of digital imaging information in a hospital, which encompasses various imaging equipment, viewing workstations, database archive systems, and a high speed fiber optic network. One of the most important requirements for integration is the standardization of communication protocols to connect devices from different vendors. Since 1985, the ACR-NEMA standard provides a hardware interface, a set of software commands, and a consistent set of data formats for point-to-point interconnection of medical equipment. However, it has been shown to be inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks has been suggested to the ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS's capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization / Open Systems Interconnection (ISO/OSI) protocols and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the proposed PACS protocol into network node. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The implementation has natural extentions to Global PACS environments. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance evaluation are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is performed on the PACS prototype node.

  • PDF

The fire patterns of vinyl and rubber cords shorted by external flame (외부화염에 의해 단락된 비닐코드 및 고무코드의 화재 패턴)

  • Kim, Dong-Woo;Shong, Kil-Mok;Kim, Dong-Ook;Kim, Young-Seok;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1655-1657
    • /
    • 2004
  • The electrical fire frequently happens through carelessness of a vinyl and rubber cords such as a poor contact, a mechanical stress and so on. Electrical fire occupies the greater part(about 30%) of all fires in Korea. In this paper, we compared to the fire dispersive patterns of vinyl and rubber cords according to the external flame in the wall-model. The fire progress and dispersive patterns were measured by a high speed imaging system(HG-100K, REDLAKE, USA). From the results, short-circuit of the vinyl cords are easy to happen than the rubber cords by the external flame. The pattern of fire was progressed a flashover, scattering and disconnection. The fire progress on the vinyl cord is not observed because the ignition energy decreases. However, the fire was progressed continuously on the rubber cord.

  • PDF

2M Class CCM(Compact Camera Module) Defect Inspection (2M급 CCM(Compact Camera Module) 불량 검사)

  • Cho S.Y.;Ko K.W.;Lee Y.J.;Lee J.H.;Kang C.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1079-1082
    • /
    • 2005
  • This paper deals with the algorithm development that inspects defects such as Lens Focus, Focus check, Black Defect, Dark Defect, Dim Defect, Color Defect, and Line Defect, Angle Defect, IrisAgc Defect caused by the process of 2M Class Compact Camera Module (CCM). Domestic market was majorly comprised of VGA(0.3 million pixel) market. But in the middle of year 2004, camera phone with Mega Pixel has appeared, and it is estimated that the camera phone with Mega Pixel will take up to 28% of total phone sales if it is released in the end of year 2004. Since the inspection of finished products is done manually, it is major obstacle in production increment In this paper, to solve these problems, we developed the imaging processing algorithm to inspect the defects in captured image of assembled CCM. The performances of the developed inspection system and we can recognize various types of defect of CCM modules with good accuracy and high speed

  • PDF

A Study on the Short-Circuit Characteristics of Vinyl Cords Damaged by External Flame (외부화염에 의해 소손된 비닐 코드의 단락 특성에 관한 연구)

  • Choi Chung-Seog;Kim Hyang-Kon;Shong Kil-Mok
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.72-77
    • /
    • 2004
  • In this paper, we studied on the short-circuit process, surface structure, and component variation of vinyl cords. In the results of high speed imaging system (HSIS) analysis, as soon as wire covering was damaged by heat, the conductor of wire came in contact with the other conduct of wire, and the short-circuit occurred. Stereomicroscope and SEM analysis indicated that the source part of wire showed V-type form. The molten beads of load part were bigger than those of source part. In the results of EDX analysis, Cu and O were detected in the source part, whereas covering material (Cl, Ca), Cu and O were detected in the load part. The results will help us to find out the cause of electrical fire.

The analysis of arc dispersion and contacts characteristics according to switching of RCD for low voltage (저압용 누전차단기의 스위칭에 따른 아크 비산 및 접점의 특성분석)

  • Kim, Dong-Woo;Kim, Hyang-Kon;Gil, Hyung-Jun;Han, Woon-Ki;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.69-73
    • /
    • 2005
  • The arc dispersion and contacts characteristics were analyzed according to switching off Residual Current Protective Device(RCD) switch. Arc dispersion process was taken by high speed imaging system at a rate of 10,000 frames per second. When RCD was switched from on to off, art was observed and it took about 2.3[ms] from the generation of arc to the extinction of arc. When RCD was switched from off to on, arc was not observed. We repeated switching on and off 1000, 3000 and 6000 times. After repetition, the surface characteristics of contacts were taken by stereo microscope and Scanning Electron Microscope(SEM). From the scattering patterns analysis of arc and the analysis of deteriorated contacts, it could be applicable to the research of electric fire and arc suppression.

  • PDF