• 제목/요약/키워드: High Speed Flow Visualization

검색결과 131건 처리시간 0.023초

평판하 연기선단의 가시화 (A Visualization of Smoke Front under a Horizontal Plate)

  • 한용식;김명배;오광철;유상필
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.41-46
    • /
    • 2001
  • 수평 평판과 충돌하는 제트에 의해 생성되는 연기유동을 관찰하기 위해 질소가스네 kerosene 연기입자를 띄워 유동장을 가시화하였다. 광원으로는 아르곤-이온 레이져 평면광이 사용되었다. Kerosene smoke의 산란 광에 의한 수직평면 상(image)과 수평평면 상을 고속 CCD 카메라와 비디오 카메라로 녹화하였으며, 얻어진 영상으로부터 연기선단의 순간속도 및 평균속도를 측정하였다.

  • PDF

실시간 홀로그래픽 간섭법을 이용한 유체의 가시화 (Visualization and Measurement of Fluids with Real-time Holographic Interferometry)

  • 엄철;강영준;김동우;유원재;안중근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.539-544
    • /
    • 2001
  • The holographic measurement techniques can be applied to various industrial fields such as automobile, airplane, construction, electronics, medical, mechanics and physics. The visualization of fluids is very important in aerodynamics, heat transfer and stress analysis. There are classically optical methods such as shadowgraph, schlieren method, and Mach-Zehnder interferometry for visualizing the fluid flow phenomena. But, it is difficult to understand the continuous state of fluids well in those methods. In this study, the real-time holographic interferometer with high-speed camera is applied to the flow visualization. In addition, collimated laser beam and rotating wedge are used for recording and formation of carrier fringes, respectively.

  • PDF

Dynamic PIV Measurement of Swirl Flow in a PC Fan

  • ARAMAKI Shinichiro;HAYAMI Hiroshi
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.41-45
    • /
    • 2004
  • The dynamic particle image velocimetry (PIV) is consisted of a high frequency pulse laser, high speed cameras and a timing controller. The three velocity components of flow downstream of an axial flow fan for PC cooling system are measured using the dynamic PIV system. An Axial flow fan has seven blades of 72 mm in diameter. The rotating speed is 1800 rpm. The downstream flow is visualized by smoke particles of about $0.3-1\;{\mu}m$ in diameter. The three-dimensional instantaneous velocity fields are measured at three downstream planes. The swirl velocity component was diffused downstream and the change in time-mean vorticity distribution downstream was also discussed. The spatio-temporal change in axial velocity component with the blades passing is recognized by the instantaneous vector maps. And the dynamic behavior of vorticity moving with the rotating blades is discussed using the unsteady vorticity maps.

  • PDF

NUMERICAL SIMULATION AND VISUALIZATION OF THE FLOW AROUND THE DARIUS WIND TURBINE

  • Lee Mi Young;Kawamura Tetuya
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.45-50
    • /
    • 2005
  • A fundamental understanding of the flow around the wind turbine is important to investigate the performance of new type of wind turbine. This study presents the simulation of three dimensional flow fields around the Darius wind turbine as an example. Incompressible Navier-Stokes equations are used for this simulation. The rotating coordinate system that rotates in the same speed of the turbine is used in order to simplify the boundary condition on the blades. Additionally, the boundary fitted coordinate system is employed in order to express the shape of the blades precisely. Fractional step method is used to solve the basic equations. Third order upwind scheme is chosen for the approximation of the non-linear terms since it can compute the flow field stably even at high Reynolds number without any turbulence models. The flow fields obtained in this study are highly complex due to the three dimensionality and are visualized effectively by using the technique of the computer graphics.

부분 슬롯을 가진 다공성 실린더의 내부 유동 가시화 (Flow Visualization in Porous Cylinder with Partial Slots)

  • 손민;김도헌;구자예;장홍빈;강문중
    • 항공우주시스템공학회지
    • /
    • 제8권3호
    • /
    • pp.1-5
    • /
    • 2014
  • An inner flow of a porous cylinder with partial slots was visualized to study fluidic phenomena in a solid rocket motor. A high-pressure chamber and an air supply system for high flow rate were used. In order to visualize the inner flow, the smoke generator with a cam-driven pump and heaters and high speed camera were adopted. The results of the cylinder type and the partial slot type were compared. As a result, the injected smoke flow in the partial slot type had circumferential fluctuations unlike the cylinder type. It was found that the circumferential flow induced from the partial slots could be the cause of combustion instability and roll torque.

Experimental Flow Visualisation of an Artificial Heart Pump

  • Tan, A.C.C.;Timms, D.L.;Pearcy, M.J.;McNeil, K.;Galbraith, A.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.210-216
    • /
    • 2004
  • Flow visualization techniques were employed to qualitatively visualize the flow patterns through a 400% scaled up centrifugal blood pump. The apparatus comprised of a scaled up centrifugal pump. high speed video camera. Argon Ion Laser Light Sheet and custom coded particle tracking software. Reynolds similarity laws are applied in order to reduce the rotational speed of the pump. The outlet (cutwater) region was identified as a site of high turbulence and thus a likely source of haemolysis. The region underneath the impeller was identified as a region of lower flow.

PIV에 의한 가정용 온수펌프의 유동장 계측 (Measurement of Flow Field in a Domestic Hot-Water Pump by PIV)

  • 이현;임유청;김재현;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.264-271
    • /
    • 1999
  • The present experimental study is aimed to investigate the flow characteristics of the high-speed flow field within hot-water pump by PIV(Particle Image Velocimetry). As multi-point simultaneous velocity acquisition, 2-D PIV system based upon the two-frame gray-level cross correlation method is adopted using PC frame-grabber and simple video system. Gated image intensifier CCD Camera to cope with illumination problem is arranged for accurate PIV measurement of high-speed complex flow. The velocity vector distribution, velocity profile, and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a pump.

  • PDF

4D-PTV (4-Dimensional Particle Tracking Velocimetry)

  • 도덕희;황태규;조용범;편용범
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.43-44
    • /
    • 2003
  • A 4D-PTV system was constructed. The measurement system consists of three high-speed high-definition cameras, Nd-Yag laser and a host computer. The GA-3D-PTV algorithm was used for completing the measurement system. A horizontal impinged jet flow was measured. The Reynolds number is about 40,000. Spatial temporal evolution of the jet flow was examined and physical properties such as spatial distributions of vorticity and turbulent kinetic energy were obtained with the constructed system.

  • PDF

마이크로 복수 분지관에서의 버블거동에 관한 연구 (Bubble Behavior in a Micro-Multi-Branched-Channel)

  • 김경천;류건호
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.32-36
    • /
    • 2006
  • Recently there are many researches about single flow and two-phase flow phenomena in the mini and microchannel. But from this result the principle in the microchannel was not explained clearly. In this paper two-phase flow pattern was visualized in the micro-multi-branched-channel using a high speed camera. Microchannel was fabricated with PDMS and glass slide. The velocity profile was obtained by a Micro PIV. Then flow boiling at the near inlet area was occurred and vapor was moved in the micro-multi-branched-channel.

  • PDF

지상운송체의 풍동시험을 위한 지면재현의 연구 (Experimental Studies on Various Ground Simulations for a Wind Tunnel Test of Road Vehicles)

  • 권혁빈;이동호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.605-610
    • /
    • 2000
  • A series of wind tunnel test were conducted on Korean high speed train model to understand the flow physics around the vehicle related to the aerodynamic drag. For the wind tunnel test on high-speed ground vehicle, a moving ground simulation is necessary to predict the aerodynamic drag accurately. So, the models were tested in three wind tunnels with various ground simulation facility including moving belt ground plane system and tangential blowing system. The test results including measured aerodynamic drag and flow visualization showed that a tangential blowing method can be an alternative ground simulation method in short time using conventional wind tunnel.

  • PDF