• Title/Summary/Keyword: High Sensitivity Receiver

Search Result 184, Processing Time 0.028 seconds

Significance of albumin to globulin ratio as a predictor of febrile urinary tract infection after ureteroscopic lithotripsy

  • Yi, Seung Yun;Park, Dong Jin;Min, Kyungchan;Chung, Jae-Wook;Ha, Yun-Sok;Kim, Bum Soo;Kim, Hyun Tae;Kim, Tae-Hwan;Yoo, Eun Sang
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.3
    • /
    • pp.225-230
    • /
    • 2021
  • Background: We aimed to analyze the effectiveness of albumin to globulin ratio (AGR) in predicting postoperative febrile urinary tract infection (fUTI) after ureteroscopic lithotripsy (URS) and retrograde intrarenal surgery (RIRS). Methods: From January 2013 to May 2018, 332 patients underwent URS and RIRS. The rate of postoperative fUTI and risk factors for postoperative fUTI were analyzed using logistic regression. Patients were divided into postoperative fUTI and non-postoperative fUTI (non-fUTI) groups. AGR with other demographic and perioperative data were compared between the two groups to predict the development of fUTI after URS. Results: Of the 332 patients, postoperative fUTI occurred in 41 (12.3%). Preoperative pyuria, microscopic hematuria, diabetes mellitus, hypoalbuminemia, and hyperglobulinemia were more prevalent in the fUTI group. Patients in the fUTI group had larger stone size, lower preoperative AGR, longer operation time, and longer preoperative antibiotic coverage period. In a multivariable logistic analysis, preoperative pyuria, AGR, and stone size were independently correlated with postoperative fUTI (p<0.001, p=0.008, and p=0.041, respectively). Receiver operating curve analysis showed that the cutoff value of AGR that could predict a high risk of fUTI after URS was 1.437 (sensitivity, 77.3%; specificity, 76.9%), while the cutoff value of stone size was 8.5 mm (sensitivity, 55.3%; specificity, 44.7%). Conclusion: This study demonstrated that preoperative pyuria, AGR, and stone size can serve as prognostic factors for predicting fUTI after URS.

A Multicenter Pilot Study of Biliary Atresia Screening Using Digital Stool Color Imaging

  • Kannamon Waitayagitgumjon;Wannisa Poocharoen;Suchin Trirongjitmoah;Kriengsak Treeprapin;Arada Suttiwongsing;Thetiya Wirifai;Chira Trirongchitmoh;Pitiporn Tangkabuanbutr
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.3
    • /
    • pp.168-175
    • /
    • 2024
  • Purpose: The presence of alcoholic stool in biliary atresia (BA) patients is the basis of a stool color card (SCC), a screening tool that has led to more patients receiving Kasai portoenterostomy earlier. This study aimed to evaluate the color image processing of stool images captured using smartphones. We propose that measuring digital color parameters is a more objective method for identifying BA stools and may improve the sensitivity of BA screening. Methods: A prospective study was conducted in five hospitals in Thailand between October 1, 2020, and December 31, 2021. Stools from infants presenting with jaundice, acholic stool, or dark-colored urine were photographed. Digital image color analysis was performed, and software was developed based on the color on the original SCC. Sensitivity and specificity for predicting BA stools were compared between the SCC and the software. Results: Of 33 infants eligible for data collection, 19 were diagnosed with BA. Saturation and blue were two potential digital color parameters used to differentiate BA stools. The receiver operating characteristic curve was used to determine the optimum cutoff point of both values, and when saturation ≤56 or blue ≥61 was set as a threshold for detecting BA stool, high accuracy was achieved at 81.8% and 78.8%, respectively. Conclusion: Digital image processing is a promising technology. With appropriate cutoff values of saturation in hue, saturation, value and blue in red, green, blue color models, BA stools can be identified, and equivocal-colored stools of non-BA patients can be differentiated with acceptable accuracy in infants presenting with jaundice.

Internal Defection Evaluation of Spot Weld Part and Carbon Composite using the Non-contact Air-coupled Ultrasonic Transducer Method (비접촉 초음파 탐상기법을 이용한 스폿용접부 및 탄소복합체의 내부 결함평가)

  • Kwak, Nam-Su;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6432-6439
    • /
    • 2014
  • The NAUT (Non-contact Air coupled Ultrasonic Testing) technique is one of the ultrasonic testing methods that enables non-contact ultrasonic testing by compensating for the energy loss caused by the difference in acoustic impedance of air with an ultrasonic pulser receiver, PRE-AMP and high-sensitivity transducer. As the NAUT is performed in a state of steady ultrasonic transmission and reception, testing can be performed on materials of high or low temperatures or specimens with a rough surface or narrow part, which could not have been tested using the conventional contact-type testing technique. For this study, the internal defects of spot weld, which are often applied to auto parts, and CFRP parts, were tested to determine if it is practical to make the NAUT technique commercial. As the spot welded part had a high ultrasonic transmissivity, the result was shown as red. On the other hand, the part with an internal defect had a layer of air and low transmissivity, which was shown as blue. In addition, depending on the PRF (Pulse Repetition Frequency), an important factor that determines the measurement speed, the color sharpness showed differences. With the images obtained from CFRP specimens or an imaging device, it was possible to identify the shape, size and position of the internal defect within a short period of time. In this paper, it was confirmed in the above-described experiment that both internal defect detection and image processing of the defect could be possible using the NAUT technique. Moreover, it was possible to apply NAUT to the detection of internal defects in the spot welded parts or in CFRP parts, and commercialize its practical application to various fields.

Evaluating the Validity of the Pediatric Index of Mortality Ⅱ in the Intensive Care Units (소아중환자를 대상으로 한 PIM Ⅱ의 타당도 평가)

  • Kim, Jung-Soon;Boo, Sun-Joo
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • Purpose: This study was to evaluate the validity of the Pediatric Index of Mortality Ⅱ(PIM Ⅱ). Method: The first values on PIM Ⅱ variables following ICU admission were collected from the patient's charts of 548 admissions retrospectively in three ICUs(medical, surgical, and neurosurgical) at P University Hospital and a cardiac ICU at D University Hospital in Busan from January 1, 2002 to December 31, 2003. Data was analyzed with the SPSSWIN 10.0 program for the descriptive statistics, correlation coefficient, standardized mortality ratio(SMR), validity index(sensitivity, specificity, positive predictive value, negative predictive value), and AUC of ROC curve. Result: The mortality rate was 10.9% (60 cases) and the predicted death rate was 9.5%. The correlation coefficient(r) between observed and expected death rates was .929(p<.01) and SMR was 1.15. Se, Sp, pPv, nPv, and the correct classification rate were .80, .96, .70, .98, and 94.0% respectively. In addition, areas under the curve (AUC) of the receiver operating characteristic(ROC) was 0.954 (95% CI=0.919~0.989). According to demographic characteristics, mortality was underestimated in the medical group and overestimated in the surgical group. In addition, the AUCs of ROC curve were generally high in all subgroups. Conclusion: The PIM Ⅱ showed a good, so it can be utilized for the subject hospital. better.

Analysis of Risk Factors to Predict Intensive Care Unit Transfer in Medical in-Patients (내과 환자의 중환자실 전동에 대한 위험요인 분석)

  • Lee, Ju Ry;Choi, Hye Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.4
    • /
    • pp.259-266
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze risk factors in predicting medical patients transferred to Intensive Care Unit (ICU) on the general ward. Methods: We reviewed retrospectively clinical data of 120 medical patients on the general ward and a Modified Early Warning Score (MEWS) between ICU group and general ward group. Data were analyzed with multivariate logistic regression and the area under the receiver operating characteristic curves using SPSS/WIN 18.0 program. Results: Fifty-two ICU patients and 68 general ward patients were included. In multivariate logistic regression, the MEWSs (Odds Ratio [OR], 1.91; 95% confidence interval [CI], 1.32-2.76), sequential organ failure assessment score (OR, 1.28; 95% CI, 1.10-1.72), $PaO_2/FiO_2$ ratio (OR, 0.98; 95% CI, 0.98-0.99), and saturation (OR, 0.93; 95% CI, 0.88-0.99) were predictive of ICU transfer. The sensitivity and the specificity of the MEWSs used with a cut-off value of six were 80.8% and 70.6% respectively for ICU transfer. Conclusion: These findings suggest that early prediction and treatment of patients with high risk of ICU transfer may improve the prognosis of patients.

The Research on SMSR Yield Improvement of the Optical Transceiver Using Modulated DFB Laser (변조된 DFB 레이저를 이용한 광 송수신기의 SMSR 수율 향상에 관한 연구)

  • Kwon, Yoon-Koo;Kim, Chang-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2285-2290
    • /
    • 2011
  • This paper is the research on SMSR yield improvement of the optical transceiver using modulated DFB laser. In general, the wavelength of DFB laser optical transceiver are 1310, 1490 and 1550 nm. Usually SMSR in modulated DFB is difficult to improve as low as 30 dB because of high slop efficiency trade off. In modulation condition, we studied SMSR improvement according to adjust bias current, extinction ratio and optical line terminal receiver sensitivity. As our test results, we can found a method how to improve SMSR for optical transceiver for long distance.

Assessment of Breast Cancer Risk in an Iranian Female Population Using Bayesian Networks with Varying Node Number

  • Rezaianzadeh, Abbas;Sepandi, Mojtaba;Rahimikazerooni, Salar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.4913-4916
    • /
    • 2016
  • Objective: As a source of information, medical data can feature hidden relationships. However, the high volume of datasets and complexity of decision-making in medicine introduce difficulties for analysis and interpretation and processing steps may be needed before the data can be used by clinicians in their work. This study focused on the use of Bayesian models with different numbers of nodes to aid clinicians in breast cancer risk estimation. Methods: Bayesian networks (BNs) with a retrospectively collected dataset including mammographic details, risk factor exposure, and clinical findings was assessed for prediction of the probability of breast cancer in individual patients. Area under the receiver-operating characteristic curve (AUC), accuracy, sensitivity, specificity, and positive and negative predictive values were used to evaluate discriminative performance. Result: A network incorporating selected features performed better (AUC = 0.94) than that incorporating all the features (AUC = 0.93). The results revealed no significant difference among 3 models regarding performance indices at the 5% significance level. Conclusion: BNs could effectively discriminate malignant from benign abnormalities and accurately predict the risk of breast cancer in individuals. Moreover, the overall performance of the 9-node BN was better, and due to the lower number of nodes it might be more readily be applied in clinical settings.

The Design of Transceiver for High Frequency Data Transmission (고주파 데이터 전송을 위한 송수신기 설계)

  • 최준수;윤호군;허창우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.7
    • /
    • pp.1326-1331
    • /
    • 2001
  • This paper has been studied about design of a transceiver for data transmission. The transceiver has bandwidth of 424.7~424.95 MHz and uses half duplex communication method, PLL synthesized, 20 channel, 12.5 KHz channel bandwidth and FSK modulation/demodulation method. The transmission set is designed using low noise amplifier and power amplifier Also, it consists of low pass filter and resonation circuit for decrease of spurious signal. The receiver set is designed using dual conversion method. Finally, the transceiver set achieves the following characteristics 9.71dbm output power, 47dbc spurious property and $\pm$12.3 Jitter at sensitivity of -1134dbm.

  • PDF

Searching and Autoalignment Method for Indoor Free-space Optical Communication (실내용 자유 공간 광 통신을 위한 수신단의 위치 탐색 및 자동 링크 정렬 방법)

  • Lee, Kwanyong;Cho, Seung-Rae;Lee, Chang-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.230-236
    • /
    • 2019
  • We propose and demonstrate a searching and autoalignment method for indoor optical wireless communication, using a cost-effective retroreflective sheet and a microelectromechanical system (MEMS) mirror. We use an extremum-seeking method for a single axis and beam steering with a MEMS mirror to maintain a line of sight (LOS) with the optical link. This autoalignment method shows a receiver sensitivity of -31.87 dBm for a bit rate of 2.5 Gb/s over a 7 m communication link.

Design and Implementation of Base Station Transceiver for Wideband CDMA PCS System (Wideband CDMA PCS 기지국용 송수신기 설계 및 구현)

  • 정영준;김봉겸;이일규;박재홍
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.61-72
    • /
    • 1997
  • The implementation of base station transceiver for Wideband CDMA(Code Division Multiple Access) PCS(Personal Communication Service) system using spread spectrum CDMA technology is presented in this paper. The receiver that requires wide dynamic range and high sensitivity and the transmitter that has good spurious emission supression were designed and implemented with 5 MHz RF channel bandwidth. This paper shows the some factors that should be considered and simulated using the RF simulation S/W with commercial and customized components. The implemented transceiver based on the simulation gave good results that satisfied the functional specifications of the transceiver.

  • PDF