DILD (diffuse infiltrative lung disease); Radiologic Diagnostic Approach According to High-Resolution CT Pattern (미만성 침윤성 폐질환; 고해상 전산화 단층촬영상 병변의 유형에 따른 방사선학적 진단접근)

  • Lee, Ki-Nam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.2
    • /
    • pp.111-119
    • /
    • 2005
  • The introduction of high-resolution CT (HRCT) in recent years has improved the ability of radiologists to detect and characterize the diffuse infiltrative lung disease (DILD). The detection and diagnosis of diffuse lung disease using HRCT are based on the recognition of specific abnormal findings. In this article, pattern recognition of HRCT findings is reviewed in the differential diagnosis of diffuse infiltrative lung disease. In general, HRCT findings of lung disease can be classified into four categories based on their appearances. These categories consist of (1) nodules and nodular opacities, (2) linear and reticular opacities, (3) increased lung opacity, and (4) decreased lung opacity, including cystic lesions.

Usefulness Evaluation of Low-dose CT for Emphysema : Compared with High-resolution CT (폐기종에 대한 저선량 CT의 유용성 평가: 고해상도 CT와 비교)

  • Lee, Won-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.329-336
    • /
    • 2016
  • The purpose of this study was to evaluate the usefulness of low-dose CT (LDCT) for emphysema compared with high-resolution CT (HRCT). Measurements of radiation dose and noise were repeated 3 times in same exposure condition which was similar with obtaining HRCT and LDCT images. We analysed reading results of 146 subjects. Six images per participants selected for emphysema grading. Emphysema was graded for all 6 zones on the left and right sides of the lungs by the consensus reading of two chest radiologists using a 4-point scale. Between the HRCT and LDCT images, diagnostic differences and agreements for emphysema were analyzed by McNemar's and unweighted kappa tests, and radiation doses and noise by a Mann-Whitney U-test, using the SPSS 19.0 program. Radiation dose from HRCT was significantly higher than that of LDCT, but the noise was significantly lower in HRCT than in LDCT. Diagnostic agreement for emphysema between HRCT and LDCT images was excellent (k-value=0.88). Emphysema grading scores were not significantly different between HRCT and LDCT images for all six lung zones. Emphysema grading scores from LDCT images were significantly correlated with increased scores on HRCT images (r=0.599, p < 0.001). Considering the tradeoff between radiation dose and image noise, LDCT could be used as the gold standard method instead of HRCT for emphysema detection and grading.

Utility of Brain Computed Tomography in Detecting Fractures of the Temporal Bones Correlated with Patterns of Fracture on High-Resolution Computed Tomography (고해상도 전산화 단층촬영에서 확인된 골절 유형에 따른 측두골 골절의 진단에서 뇌전산화 단층촬영의 유용성)

  • Kwon, Bong-Seok;Shin, Dong-Hyuk;Choi, Pil-Cho;Han, Sang-Kuk;Lee, Jeong-Hun;Song, Hyoung-Gon
    • Journal of Trauma and Injury
    • /
    • v.23 no.1
    • /
    • pp.38-42
    • /
    • 2010
  • Purpose: The clinical utility of brain computed tomography (CT) in detecting temporal bone fracture is not well established. We performed this study to determine the utility of brain computed tomography (CT) in detecting fractures of the temporal bones in correlation with fracture patterns. We used high resolution computed tomography (HRCT) as the gold standard for diagnosing temporal bone fracture and its pattern. Methods: From January 2007 to December 2009, patients who underwent both brain CT and HRCT within 10 days of head trauma were investigated. Among them, 58 cases of temporal bone fracture confirmed by HRCT were finally included. Fracture patterns (transverse or non-transverse, otic capsule sparing or otic capsule violating) were determined by HRCT. Brain CT findings in correlation with fracture patterns were analyzed. Results: Among 58 confirmed cases of temporal bone fracture by HRCT, 14 cases (24.1%) were not detected by brain CT. Brain CT showed a significantly lower ability to detect temporal bone fracture with transverse component than without transverse component (p=0.020). Moreover, brain CT showed lower ability to detect otic capsule violating pattern than otic capsule sparing pattern (p=0.015). Among the 14 cases of temporal bone fracture that were not detected by brain CT, 4 cases lacked any objective physical findings (facial palsy, hemotympanum, external auditory canal bleeding) suggesting fractures of the temporal bones. Conclusion: Brain CT showed poor ability to detect temporal bone fracture with transverse component and otic capsule violating pattern, which is associated with a poorer clinical outcome than otic capsule sparing pattern. Routine use of HRCT to identify temporal bone fracture is warranted, even in cases without evidence of temporal bone fracture on brain CT scans or any objective physical findings suggestive of temporal bone fracture.

Diffuse Infiltrative Lung Disease : Comparison of Diagnostic Accuracies of High-Resolution CT and Radiography (미만성 침윤성 폐질환의 진단: HRCT와 단순흉부X선사진의 비교)

  • Kim, Kyeong-Ah;Kang, Eun-Young;Oh, Yu-Whan;Kim, Jeung-Sook;Park, Jai-Soung;Lee, Kyung-Soo;Kang, Kyung-Ho;Chung, Kyoo-Byung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.388-402
    • /
    • 1996
  • Background : To compare the diagnostic accuracies of High-resolution CT(HRCI) and chest radiography in the diagnosis of diffuse infiltrative lung disease(DILD). Methods : This study included ninety-nine patients with a diagnosis of acute or chronic DILD, representing 20 different diseases. Twelve normal subjects were included as control. The disease state was confirmed either pathologically or clinically. Radiographs and CT scans were evaluated separately by three independent observers without knowledge of clinical and pathologic results. The observers listed three most likely diagnoses and recorded degree of confidence. Results : The sensitivity of HRCT in the detection of DILD was 98.9% compared to 97.9% of chest radiography. Overall, a correct first-choice diagnosis was made in 48% using chest radiographs and in 60% using HRCT images. The correct diagnosis was among the top-three choices in 64% when chest radiographs were used, and in 75% when HRCT images were reviewed. Overally a confident diagnosis was reached more often with HRCT(55%) than with chest radiography(26%). The correct first-choice diagnosis increased remarkably when the HRCT was used in usual interstitial pneumonia, miliary tuberculosis, diffuse panbronchiolitis and lymphangitic carcinomatosis. Conclusion : HRCT is confirmed to be superior to conventional radiography in the detection and accurate diagnosis of DILD. HRCT is especially valuable in the diagnosis of usual interstitial pneumonia, miliary tuberculosis, diffuse panbronchiolitis, and lymphangitic carcinomatosis.

  • PDF

Cystic Lung Disease: a Comparison of Cystic Size, as Seen on Expiratory and Inspiratory HRCT Scans

  • Ki-Nam Lee;Seong-Kuk Yoon;Seok Jin Choi;Jin Mo Goo;Kyung-Jin Nam
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.84-90
    • /
    • 2000
  • Objective: To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. Materials and Methods: The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. Results: All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. Conclusion: In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary.

  • PDF

Correlation between High-Resolution CT and Pulmonary Function Tests in Patients with Emphysema (폐기종환자에서 고해상도 CT와 폐기능검사와의 상관관계)

  • Ahn, Joong-Hyun;Park, Jeong-Mee;Ko, Seung-Hyeon;Yoon, Jong-Goo;Kwon, Soon-Seug;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.367-376
    • /
    • 1996
  • Background : The diagnosis of emphysema during life is based on a combination of clinical, functional, and radiographic findings, but this combination is relatively insensitive and nonspecific. The development of rapid, high-resolution third and fourth generation CT scanners has enabled us to resolve pulmonary parenchymal abnormalities with great precision. We compared the chest HRCT findings to the pulmonary function test and arterial blood gas analysis in pulmonary emphysema patients to test the ability of HRCT to quantify the degree of pulmonary emphysema. Methods : From october 1994 to october 1995, the study group consisted of 20 subjects in whom HRCT of the thorax and pulmonary function studies had been obtained at St. Mary's hospital. The analysis was from scans at preselected anatomic levels and incorporated both lungs. On each HRCT slice the lung parenchyma was assessed for two aspects of emphysema: severity and extent. The five levels were graded and scored separately for the left and right lung giving a total of 10 lung fields. A combination of severity and extent gave the degree of emphysema. We compared the HRCT quantitation of emphysema, pulmonary function tests, ABGA, CBC, and patients characteristics(age, sex, height, weight, smoking amounts etc.) in 20 patients. Results : 1) There was a significant inverse correlation between HRCT scores for emphysema and percentage predicted values of DLco(r = -0.68, p < 0.05), DLco/VA(r = -0.49, p < 0.05), FEV1(r = -0.53, p < 0.05), and FVC(r = -0.47, p < 0.05). 2) There was a significant correlation between the HRCT scores and percentage predicted values of TLC(r = 0.50, p < 0.05), RV(r = 0.64, p < 0.05). 3) There was a significant inverse correlation between the HRCT scores and PaO2(r = -0.48, p < 0.05) and significant correlation with D(A-a)O2(r = -0.48, p < 0.05) but no significant correlation between the HRCT scores and PaCO2. 4) There was no significant correlation between the HRCT scores and age, sex, height, weight, smoking amounts in patients, hemoglobin, hematocrit, and wbc counts. Conclusion : High-Resolution CT provides a useful method for early detection and quantitating emphysema in life and correlates significantly with pulmonary function tests and arterial blood gas analysis.

  • PDF

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Analysis of High-Resolution CT Findings in Patients with Spontaneous Pneumothorax (자연기흉환자의 고해상 CT소견의 분석)

  • 김양수;손동섭
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.383-387
    • /
    • 1999
  • Background: We analysed simple chest PA and high-resolution CT findings in patients with spontaneous pneumothorax in order to help selecting the kind of treatment, provide a guidline during surgical treatment, and to recognize the bulla which may not be detected by simple radiographs or may be a potential cause of recurrence. Material and Method: We retrospectively analysed the presence and number of bulla in each side, combined pulmonary disease on simple chest films and high-resolution CT, and methods and frequency of the treatment in 70 patients with spontaneous pneumothorax excluing traumatic origin. Result: 45 patients were revealed primary spontaneous pneumothorax, and the remaining 25 patients were revealed secondary spontaneous pneumothorax. All secondary spontaneous pneumothorax were from the longstanding sequelle of pulmonary tuberculosis. The patients with primary spontaneous pneumothorax group was younger(mean:26.0 years old) than secondary group (mean: 44.1 years old). On simple radiography, bulla was detected in 16 patients(30.2%). On HRCT, the bulla was detected in 53 patients(75.7%) of the total 70 patients. In 48 patients(68.6%), the bulla or bleb was noted in ipsilateral side to the pneumothorax, and 34 patients(48.6%) of them showed bulla or bleb bilaterally. 39 patients(55.7%) showed bulla or bleb in contralateral side. The number of bulla or bleb was variable. In secondary spontaneous pneumothorax group, the incidence of multiple(more than 10) bulla or bleb was higher than primary type. Most of the patients were treated by thoracostomy(36 patients) or bullectomy( 7 patients). Conclusion: HRCT was superior to detect bulla and analyse the combined pulmonary disease than simple radiography. Therefore, HRCT can help to determine the mothod of treatment, provide a guidline during surgical treatment, and notify the bulla as a possible cause of recurrent pneumothorax.

  • PDF

High-resolution computed tomography findings of lung parenchyme changes in very low birth weight infants treated with oxygen (산소 치료를 받은 극소저출생 체중아에서 폐 실질변화에 관한 고해상컴퓨터 단층촬영술 소견에 관한 연구)

  • Jin, Young Man;Chung, David Chanwook;Chang, Young Pyo;Lee, Yung Suk;Lee, En Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • Purpose : The objective of this study is to observe high-resolution computed tomography (HRCT) findings of lung parenchyme in very low birth weight (VLBW) infants between the corrected age of 38-42 weeks who were treated with oxygen after birth, and to compare them to the clinical severity of bronchopulmonary dysplasia (BPD). Methods : The lungs of fourty-four VLBW infants with gestational ages of less than 32 weeks and birth weights of less than 1,500 g who were treated with oxygen after birth were examined using HRCT taken when the corrected age was between 38-42 weeks. Common findings among the infants and the frequency of their occurrences were noted. Total CT scores obtained by the summation of air trapping and actelectasis scores and the ratio of bronchus-to-pulmonary artery diameter were used to quantitatively evaluate HRCT findings and correlate them with the clinical severity of BPD as defined by Jobe-Bancalari diagnostic criteria. Results : 1) The most common findings in HRCT images of the lungs were air trapping (56%), atelectasis (70.5%), linear opacity (77%), and distortion of the bronchopulmonary bundle (65.9%). These findings were more commonly observed in infants with BPD in a mixed pattern than those without (P<0.05). However, abnormal findings were also found in HRCT images of some infants without BPD. In infants with BPD, air trapping, atelectasis and total CT scores were higher than those without BPD. Also infants with BPD had a lower bronchus-to-pulmonary artery diameter than those without BPD (P<0.05). 2) The total CT scores (r=0.799, P<0.0001) and the ratio of bronchus-to-pulmonary artery diameter (r=0.576, P<0.0001) showed a linear correlation with the clinical severity of BPD. Conclusion : HRCT findings in VLBW infants between the corrected age of 38-42 weeks who had been treated with oxygen after birth are useful in revealing pathologic changes in the lung parenchyme and show a good correlation with the clinical severity of BPD.