• 제목/요약/키워드: High Pulse pressure

검색결과 313건 처리시간 0.031초

고 출력 레이저에 의한 충격파 현상 연구 및 응용 (High Power Laser Driven Shock Compression of Metals and Its Innovative Applications)

  • 이현희;곽민철;최지혜;여재익
    • 대한기계학회논문집B
    • /
    • 제32권11호
    • /
    • pp.832-840
    • /
    • 2008
  • Ablation occurs at irradiance beyond $10^9\;W/cm^2$ with nanosecond and short laser pulses focused onto any materials. Phenomenologically, the surface temperature is instantaneously heated past its vaporization temperature. Before the surface layer is able to vaporize, underlying material will reach its vaporization temperature. Temperature and pressure of the underlying material are raised beyond their critical values, causing the surface to explode. The pressure over the irradiated surface from the recoil of vaporized material can be as high as $10^5\;MPa$. The interaction of high power nanosecond laser with a thin metal in air has been investigated. The nanosecond pulse laser beam in atmosphere generates intensive explosions of the materials. The explosive ejection of materials make the surrounding gas compressed, which form a shock wave that travels at several thousand meters per second. To understand the laser ablation mechanism including the heating and ionization of the metal after lasing, the temporal evolution of shock waves is captured on an ICCD camera through laser flash shadowgraphy. The expansion of shock wave in atmosphere was found to agree with the Sedov's self-similar spherical blast wave solution.

IGBT를 이용한 고반복 펄스형 $CO_2$ 레이저 개발에 관한 연구 (A Study on the High Repetition Rate Pulsed $CO_2$ Laser Using IGBT)

  • 정현주;김도완;이동훈;윤성호;이유수;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1072-1074
    • /
    • 1999
  • In this study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 kHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2:N_2$:He = 1.3:10, 1:1.5:5 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average output was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2:N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF

Analysis of leakage factors affecting ECV performance in variable compressor

  • Mahmud, Md. Iqbal;Cho, Haeng Muk
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.183-188
    • /
    • 2014
  • Solenoid operated electromagnetic control valve (ECV) using in an external variable displacement swash plate type compressor is widely used for air conditioning control system because of its low energy consumption and high efficient characteristics. ECV controls the entire vehicle air conditioning system by means of a pulse width modulation (PWM) system that supplied from an external controller. Different pressure ports located within ECV has important functions to control the air/refrigerant flow through its internal passages. The flow paths are preciously maintained with acceptable ranges of leakage (gap) between the parts inside it which is followed by effective design and critical dimensioning of its internal features. Therefore, it saves energy losses from the solenoid operation as well as ensures the balance of forces within it. The research paper highlights analysis of the leakages (at different pressure ports) and dimensioning tolerance factors that affects the ECV performance.

고령자용 실내계단 디자인에 관한 인간공학적 실험연구 (The Study of Ergonomics on Stairways Design in Elderly Housing)

  • 김경일;최창렬;안옥희
    • 한국주거학회논문집
    • /
    • 제9권3호
    • /
    • pp.107-118
    • /
    • 1998
  • In order to provide the basic data for planning of stairways design in elderly housing, the study of Ergonomics were exmined. 3 old women and 3 female subjects were tested: 1) The relations between blood pressure and pulse: In case of the old, blood pressure was the highest at 13 cm and pulse was the highest at 23 cm. But in case of the young, the former was the highest at 23 cm and the latter was at 13 cm. 2) EMG: According to the height of stairs, the significant differences on the statistics were not seen. 3) Riviewing that biological characters according to the finishing materials, in case of the old groups, they feel most stable, as they up the wooden stairs. While they feel very dangerous, as they up the stairs where carpet is on. In the biological characters according to the stairs heights and the finishing materials, the most stable conditions for the old are 15 cm-high-stairs, wooden. And even if the stairs used inside the house, the installment of the handrails at both side must be considered.

  • PDF

SMPS 방식의 고반복 펄스형 $CO_2$레이저의 출력특성 최적화 (The Optimization of Output Characteristics with High Repetition Rate Pulsed $CO_2$ Laser Using SMPS)

  • 이동훈;정현주;김도완;김휘영;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2192-2194
    • /
    • 1999
  • In this study, We have accomplished a new approach to develope a cheap and compact pulsed $CO_2$ laser system. We used a fast SCR as switching device instead of a thyatron in the pulsed power supply. Using the Pulse transformer, energy in the condenser is tranferred to the secondary, electrodes of discharge tube, from the primary. An axial and water cooled type was adopted as the laser cavity. The laser performance characteristics as various parameters, such as gas pressure and pulse repetition rate, have been investigated. As a result, the maxium laser output was 12.3[W] at a pulse repetition rate of 120[pps] and a filling pressure of 12[Torr].

  • PDF

전열화학포용 2.4MJ 펄스 파워 전원의 제어기 설계 (The Controller Design of a 2.4MJ Pulse Power Supply for a Electro-Thermal-Chemical Gun)

  • 김종수;진윤식;이홍식;임근희;김진성
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권12호
    • /
    • pp.511-517
    • /
    • 2006
  • The key issues in high power, high energy applications such as electromagnetic launchers include safety, reliability, flexibility, efficiency, compactness, and cost. To explore some of the issues, a control scheme for a large current wave-forming was designed, built and experimentally verified using a 2.4MJ pulse power system (PPS). The PPS was made up of eight capacitors bank unit, each containing six capacitors connected in parallel. Therefore there were 48 capacitors in total, with ratings of 22kV and 50kJ each. Each unit is charged through a charging switch that is operated by air pressure. For discharging each unit has a triggered vacuum switch (TVS) with ratings of 200kA and 250kV. Hence, flexibility of a large current wave-forming can be obtained by controlling the charging voltage and the discharging times. The whole control system includes a personal computer(PC), RS232 and RS485 pseudo converter, electric/optical signal converters and eight 80C196KC micro-controller based capacitor-bank module(CBM) controllers. Hence, the PC based controller can set the capacitor charging voltages and the TVS trigger timings of each CBM controller for the current wave-forming. It also monitors and records the system status data. We illustrated that our control scheme was able to generate the large current pulse flexibly and safely by experiments. The our control scheme minimize the use of optical cables without reducing EMI noise immunity and reliability, this is resulting in cost reduction. Also, the reliability was increased by isolating ground doubly, it reduced drastically the interference of the large voltage pulse induced by the large current pulse. This paper contains the complete control scheme and details of each subsystem unit.

고전압 펄스형 전원을 사용한 질소레이저의 자체 선전리 효과 (Self-Preionization Effects of the Nitrogen Laser Using High Voltage Pulse Power Suply)

  • 이치원;안근옥;추한태;양준묵
    • 한국광학회지
    • /
    • 제1권2호
    • /
    • pp.169-177
    • /
    • 1990
  • 레이저관내에 별도의 전극을 설치하지 않고 레이저전극 자체만으로 선전리 효과를 얻을 수 있는 질소레이저를 연구하였다. 이를 위하여 펄스형 전원과 고속고전압 방전간극을 사용하는 레이저를 제작하였으며, 레이저관 양단에는 저항 또는 인덕터를 연결하여 이들이 레이저 동작특성에 미치는 영향과 자체 선전리 효과를 함께 연구하였다.

  • PDF

ABS 유압 장치의 유충 현상에 관한 연구 (A Study on the Pressure Surge of ABS Hydraulic System)

  • 김병우;송창섭
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.140-147
    • /
    • 2001
  • The solenoid valve in ABS hydraulics, modulator is a two directional on-off valve and is controlled by around 100Hz high speed pulse width modulation. When the inlet valve is switched from open state to closed state, there are braking force degration, noise and vibration due to pressure surge phenomena in the hydraulic line and wheel cylinder. In this study, identifies pressure surge phenomenon in the braking process of a ABS, and investigates the way to reduce the phenomenon. For the purpose theoretical analysis on the pressure surge in the closed state hydraulic line, characteristic curve method based on wave equation was utilized. During this analysis, we could find pressure surge characteristics change due to hydraulic line change and PWM control conditions. In conclusion, by using the results of this study for the pressure surge prediction and reduction method, we could expect braking performance enhancement in Anti-Lock Braking System.

  • PDF

스마트 헬스케어를 위한 자계용적맥파 기반 혈압 추정에 관한 연구 (A Study on the Estimation of Blood Pressure Based on the Magneto-Plethysmography for Smart Healthcare)

  • 이성수;이강휘;김상민;이혁재;이병헌;김경섭;이정환
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.917-927
    • /
    • 2018
  • High blood pressure causes various cardiovascular diseases and is associated with mortality. Periodic self-monitoring and recording of blood pressure is very helpful in preventing the occurrence of secondary diseases caused by hypertension. However, existing cuff-type blood pressure monitors have many limitations. As an alternative of that, a method of estimating the blood pressure by measuring the velocity change of the blood flow using the photo plethysmography is widely known. However, photo plethysmography have a low correlation with blood flow. So, we will propose an algorithm for estimating blood pressure using the relationship between velocity change of blood flow measured by magnetic field instead of photo plethysmography and electrocardiogram. For this purpose, First, we analyzed the correlation between photo plethysmography and magneto plethysmography. the correlation between MPG and PPG was r = 0.9449. Second, we compared estimated blood pressure and measured blood pressure. In the four experiment each result was r = 0.5737, r = 0.7863, r = 0.5669, and r = 0.7445.

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.