• Title/Summary/Keyword: High Pulse pressure

Search Result 312, Processing Time 0.032 seconds

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

The Ablation Effect of Fabric/EPDM Rubber with Manufacturing process (Fabric/EPDM계 고무의 제작 공정에 따른 삭마 특성)

  • Kim, Jin-Yong;Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man;Rhee, Young-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.92-95
    • /
    • 2012
  • The dual pulse rocket motor is a pressure vessel containing two pulse grains separated by a pulse separation device such as a fragile bulkhead. One of the important things in this systems is case insulation design using the excellent materials in the 1st stage pulse motor. We investigated manufacturing process of fabric/EPDM chamber insulations in order to protect the 1st stage pulse motor case with high intensity gas flow. Simulation motor connected with extension tube having FRP disc was designed to study ablation characteristics of insulation.

  • PDF

Plasma Assisted Nitriding of Stainless Steel Type 304L (304L 스테인리스 강의 플라즈마 질화처리)

  • Park, J.R.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.8 no.4
    • /
    • pp.255-265
    • /
    • 1995
  • Stainless steel type 304L has been nitrided in the low pressure (600Pa) and high nitrogen (80% $N_2$+20% $H_2$) environment for 5 hours by the square-wave-pulsed-d.c. plasma as a function of temperature $400{\sim}550^{\circ}C$ and pulsation. At the lower temperature range of $400{\sim}500^{\circ}C$ and at the relatively high ratio of pulse duration to pulse period. "S-phase" has been developed in the form of thin nitrided surface layer which has many cracks, leading to be nearly impossible for the industrial anti-wear and anti-corrosion applications. At the higher temperature up to $550^{\circ}C$ with the increasing ratio of the pulse duration to pulse period up to $50{\mu}s/100{\mu}s$, the nitrided layer, whose growth rate has increased also, has been composed mainly of CrN and $Fe_4N$ phases and has become thick, uniform and nearly crack-free.

  • PDF

A study on the design of triggering pulse generator for the triggered vacuum switch (진공스위치 트리거 발생기 설계에 관한연구)

  • Kim, Mu-Sang;Son, Yun-Gyu;Park, Ung-Hwa;Lee, Byeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.201.2-201.2
    • /
    • 2016
  • The triggered vacuum switch (TVS) is widely used as a high power switch in the field of pulsed power application. TVS can produce current of higher than 100 kA within a microsecond after being triggered. A triggering high voltage pulse generator supplies a high voltage signal to the trigger system to initiate the discharge between a trigger pin and one of main electrode. The trigger system, which consists of a tungsten trigger electrode and cylindrical ceramic insulator around it, is normally installed at the center of main cathode electrode. The discharging characteristics of the trigger system strongly depend on the geometry, electrode material, vacuum pressure and so on. In addition, we especially will focus on the developing a triggering pulse generator, which can vary not only value of voltage but also pulse duration, because its properties gives pivot influences on the TVS discharge. To verify such effects, we made a 3.3 kJ TVS set-up initially. Thus we will discuss some of prominent results from 3.3 kJ TVS system. In parallel we will show on the design of 300 kJ TVS system for the high current in the future.

  • PDF

A Study on the Cyclic Pressure Function in Freeze Drying of Foodstuff (식품의 냉동 건조에서 주기 압력 함수에 대한 연구)

  • Mun, Jae-Choel;Kim, Soo-Ho;Hwang, Kap-Sung;Hong, Song-Sun
    • Applied Chemistry for Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • We show that the usage of the cyclic pressure function in the freeze drying is more effective than the drying rate of the constant pressure process. The ultimate object of this process is to reduce energy costs by shortening the drying time. In this work, the concept of cyclic pressure function to decrease the drying time and the effects of the following factors on drying rate are considered ; pulse type, size in amplitude of pressure, size of intermediate time. Temperature for drying has always been maintained constantly at $20^{\circ}C$ and the pulse type could have found to give useful results than the constant pressure by altering chamber pressure from low pressure to high pressure Also, when the amplitude of the pulse is 0.4 torr and the intermediate time is six hour the drying rate was increased considerably.

  • PDF

Design and evalution of pulsed $CO_2$ laser system using high repetition ratio and high precision (고반복율 및 고정밀방식을 이용한 펄스형 $CO_2$ Laser 시스템 설계 및 평가)

  • 김흥수;김휘영
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.8
    • /
    • pp.1055-1062
    • /
    • 2001
  • Study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 KHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate, gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2$$N_2$:He = 1:3:10, 1:1.5:5, 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average outpu was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2$$N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF

Experimental Studies on the interaction of Kangsimsan and Hydralazine, Verapamil, Clonidine, Hydrochlorothiazide and Furosemide (고혈압(高血壓)에 강심산(强心散)과 Hydralazine, Clonidine, Hydrochlorothiazide 및 Furosemide의 병용투여(倂用投與)에 관한 실험적(實驗的) 연구(硏究))

  • Kim, Jin-Don;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.198-211
    • /
    • 1994
  • After giuing some anti-high blood pressure medicine of boiled-compressed fluid and 5-Kinds factors(Hydralazine, Verapamil, Clonidine, Furosemide and Hydrochlorothiazide with Kangsimsan to animals in single or together. I got the following conclusion in comparing blood-pressure and pulse of circulating system with urinating operation. 1. By joint-use of Kangsimsan and Hydralazine. it was found out that the effect of blood-pressure lowering continues longer in together-use than in single. And I coule see that the number of pulse increased. 2. By joint-use of Kangsimsan and Verapamil. the blood-pressure lowering operation was kept better in together-use than in single. the number of pulse was not affected any. 3. By joint-use of Kangsimsan and Clonidine the blood-pressure lowering operation was not found out any concrete result. 4. By joint-use of Kangsimsan and Furosemide. the Remarkble effect of Urinization was recognized to be much better in joint-use than in single. 5. By joint-use of Kangsimsan and Hydrochlorothiazide. the suppressing effect of urinization was recognized to be much better in joint-use than in single. Therefore in consideration of the above study and observation. when the joint-use of Kangsimsan and the blood-pressure lowering medicine. Hydralazine and Verapamil. the period of blood-pressure lowering was kept and I can conclude that in case of joint-use of Furosemide, a kind of good urinization. the effect of urinization by Furosemide is increased, but that of Hydrochlorothiazide is disturbed.

  • PDF

Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture Original Articles (산삼 약침이 정상 중년여성의 맥파요인에 미치는 영향)

  • Park, Sang-Wook;Kim, Yi-Soon;Hwang, Won-Deok;Kim, Gyeong-Cheol
    • Journal of Pharmacopuncture
    • /
    • v.14 no.1
    • /
    • pp.35-49
    • /
    • 2011
  • Objectives: The aim of this experiment is to know about Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture. Methods: First 20 Middle Aged women are diagnosed by pulse diagnosis, and then Mountain Cultivated Ginseng Pharmacopuncture(1 injection 20cc) were injected. 30 minutes later, pulse diagnosis again performed. As a result, method of one-group pretest-posttes design were used for evaluation. Results: T(Total pulse cycle) time statistically significant increased on both left and right chon, kwan, cheok. T4 time statistically significant increased on both left and right chon, kwan, cheok. T4-T1/T indexs except left cheokmaek, Right cheokmaek observation area decreased significantly in four sites. Wm(indicating high pressure retention time) indexs increased significantly in the five sites were observed except right chon maek. Conclusions: Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture increased T, T4, Wm and decreased T4-T1/T indexs. The results of this experiment, Mountain Cultivated Ginseng Pharmacopuncture induced to increase the Pulse-wave's stability and strength.

Body Systemic Circulation Assessment Method through Analysing the Radial, Dorsalis Pedis, Temporal Arterial Pulse Wave (3부위 최적맥파의 주파(h1) 비율 분석을 통한 전체 체순환 평가방법)

  • Yu, Seung-Yeon;Park, Eun-Sung;Choi, Ye-Bin;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.3
    • /
    • pp.121-130
    • /
    • 2016
  • Objectives : Recently, people who have normal brachial blood pressure(BP) are being threatened by high-risk disease such as stroke. The aim of this study is to suggest that new method to assess systemic circulation. It can be performed by analyzing optimal blood pulse wave on 3 sites belonging to subjects that have normal BP. Methods : We respectively extracted main peaks(h1) of optimal blood pulse wave on left/right temporal artery(LR1=h1), radial artery(LR2=h1) and dorsalis pedis artery(LR3=h1). We obtained h1 from 30 subjects who are discreetly chosen and have normal BP. Main peak(h1) can be extracted by using 3D pulse imaging analyser(DMP-1000+, DAEYOMEDI Co., Korea) that has 5-level pressure method. We analyzed the ratio of [LR1/LR2] and [LR3/LR2]. Results : In the case of male group, the results are [LR1/LR2=0.7100.177] and [LR3/LR2=0.9290.317]. In the case of female group, the results are [LR1/LR2=0.6680.121] and [LR3/LR2=0.7050.195]. Especially, it is statistically verified that the result of ratio [LR3/LR2] is much higher in male group than in female group(p<0.05). Conclusions : We suggested the standard ratio of [LR1/LR2] and [LR3/LR2] for normal subjects, respectively. It can be adopted as a new method to evaluate the systemic circulation.

Novel Detection Algorithm of The Upstroke of Pulse Waveform for Continuously Varying Contact Pressure Method (연속 가압방식의 맥파 측정방법을 위한 시작점 검출 알고리즘 개발)

  • Bae, Jang-Han;Jeon, Young-Ju;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.46-54
    • /
    • 2012
  • We propose a continuously varying contact pressure(CVCP)-adaptive feature extraction algorithm for pulse diagnostic analysis. The CVCP method measures the pulse waveform with continuously increasing contact pressure(CP). This method offer a high resolution signal of the pulse waveform amplitude(PWA) as a function of the contact pressure. Therefore it enables us to overcome the limitation of commercially available pulse-taking devices whose analysis rely on a few number of PWA-CP pairs. We show that an efficient feature extraction algorithm which covers the features of the CVCP-method can be developed by sequentially applying Fast Fourier Transform, peak detection by center-to-edges method, baseline drift removal, detection of the percussion wave upstroke by intersecting tangent method and detection of the analysis region. Finally, by a clinical study with 30 subjects, we show that our CVCP-adaptive feature extraction algorithm detected the upstroke with accuracy of 99.46% and sensitivity of 99.51%, which were about 4.82% and 2.46% increases respectively, compared to a conventional feature extraction method. The proposed CVCP method and the CVCP-adaptive feature extraction algorithm are expected to improve the accuracy in the pulse diagnostic algorithms such as floating/sunken pulse qualities and deficient/excess pulse qualities.