• Title/Summary/Keyword: High Power System

검색결과 9,151건 처리시간 0.037초

Low Cost High Power Density Photovoltaic Power Conditioning System with an Energy Storage System

  • Jang, Du-Hee;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.487-494
    • /
    • 2012
  • A new low cost high power density photovoltaic power conditioning system (PV PCS) with an energy storage system is proposed in this paper. Its high power density and cost effectiveness can be achieved through the unification of the maximum power point tracker and the battery charger/discharger. Despite the reduced power stage, the proposed system can achieve the same performance in terms of maximum power point tracking and battery charging/discharging as the conventional system. When a utility power failure happens, the proposed system cannot perform maximum power point tracking at the UPS mode. However, the predetermined battery voltage near the maximum power point of the PV array can effectively generate a reasonable PV power even at the UPS mode. Therefore, it features a simpler structure, less mass, lower cost, and fewer devices. Finally, to confirm the operation, validity, and features of the proposed system, a theoretical analysis and experimental results from a single phase AC 220Vrms/1.5kW prototype are presented.

High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules

  • Choi, Woo-Young;Choi, Jae-Yeon
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.561-567
    • /
    • 2011
  • This paper presents a high-efficiency power conditioning system (PCS) for grid-connected photovoltaic (PV) modules. The proposed PCS consists of a step-up DC-DC converter and a single-phase DC-AC inverter for the grid-connected PV modules. A soft-switching step-up DC-DC converter is proposed to generate a high DC-link voltage from the low PV module voltage with a high-efficiency. A DC-link voltage controller is presented for constant DC-link voltage regulation. A half-bridge inverter is used for the single-phase DC-AC inverter for grid connection. A grid current controller is suggested to supply PV electrical power to the power grid with a unity power factor. Experimental results are obtained from a 180 W grid-connected PV module system using the proposed PCS. The proposed PCS achieves a high power efficiency of 93.0 % with an unity power factor for a 60 Hz / 120 Vrms AC power grid.

60Hz 절연변압기가 없는 고주파링크방식 계통연계형 태양광발전시스템 고찰 (Study of 60Hz Transformer-less High Frequency Linked Grid-Connected Power Conditioners for Photovoltaic Power System)

  • 유권종;정영석;최주엽
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.563-569
    • /
    • 2002
  • 본 연구는 60Hz 절연변압기가 없는 형태의 고주파링크방식의 계통연계형 PCS(Power Conditioning System)를 개발하였다. 본 시스템은 고주파 DC-DC 컨버터, 고주파 절연변압기, 풀브리지 다이오드 정류기, DC filter, 저주파 인버터, LC 필터로 구성되어 있다. 고주파 DC-DC 컨버터는 20kHz의 bipolar PWM 펄스를 발생시키며, 이 펄스는 고주파 절연변압기를 통해 승압되고, 풀브리지 다이오드를 통해 정류된다. 마지막으로 저주파 인버터를 통해 정현파 전류가 계통에 유입되게 된다. 제안한 고주파링크방식의 시스템은 기존의 60Hz 절연변압기를 사용하는 시스템 보다 많은 스위칭 소자가 사용되지만, 60Hz 절연변압기를 생략함으로서 시스템의 소형경량화 및 저가화를 이룰 수 있었다.

Dynamic Load Profile 조건의 전원 장치에 있어서 계통 Peak Power 제한/보상 전력 회로 (Grid Peak Power Limiting / Compensation Power Circuit for Power Unit under Dynamic Load Profile Conditions)

  • 정희성;박도일;이용휘;이창현;노정욱
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.376-383
    • /
    • 2022
  • The improved performance of computer parts, such as graphic card, CPU, and main board, has led to the need for power supplies with a high power output. The dynamic load profile rapidly changes the usage of power consumption depending on load operations, such as PC power and air conditioner. Under dynamic load profile conditions, power consumption can be classified into maximum, normal, and standby power. Several problems arise in the case of maximum power. Peak power is generated at the system power source in the maximum-power situation. Frequent generation of peak power can cause high-frequency problems and reduce the life of high-pressure parts (especially high-pressure capacitors). For example, when a plurality of PCs are used, system overload occurs due to peak power generation and causes problems, such as power failure and increase in electricity bills due to exceeded contract power. To solve this problem, a system peak power limit/compensation power circuit is proposed for a power supply under dynamic load profile conditions. The proposed circuit detects the system current to determine the power situation of the load. When the system current is higher than the set level, the circuit recognizes that the system current generates peak power and compensates for the load power through a converter using a super capacitor as the power source. Thus, the peak power of loads with a dynamic load profile is limited and compensated for, and problems, such as high-frequency issues, are solved. In addition, the life of high-pressure parts is increased.

철도 고압배전계통의 보호시스템 최적화 방안 연구 (Optimization of protection System on the Railway High Voltage power System)

  • 조웅기;창상훈;한성호;김왕곤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(II)
    • /
    • pp.989-994
    • /
    • 2002
  • In case the fault occurs in railway high voltage power supply network, protective relaying system must selectively detect 1 wire ground fault of grounding or non-grounding system. And this study presents railway high voltage power supply system model using PSCAD/EMTDC Vet 3.08 for circuit analysis and fault studies. In this paper, we propose protection method of non-grounding system of railway high voltage power supply system. The result shows its usefulness.

  • PDF

두 개의 정현 신호를 이용한 속도 측정용 고전력 쏘나 시스템 개발 (Development of a High Power SONAR System Measuring Velocity by Using Two Gated Sinusoidal Signals)

  • 장순석;안흥구;이제형
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.1036-1041
    • /
    • 1999
  • This paper aims for the development of the high power sonar system for measuring the velocity of a moving object. The high power sonar system transmits two gated 190 kHz sinusoidal signals with 1.6 [ms] time interval to the moving object. Then the sonar system detects and calculates the changed time delay of the reflected ultrasonic signals in order to derive the velocity of the moving object. The transmission part uses a high power amplifier so that 250 W gated sinusoidal signals can be transmitted to the transmitter. 1M RAM is utilized for transmitting and storing of the ultrasonic signals. The time delay is calculted by the cross-correlation technique between the transmitted signals and the received signals. The measured value from the high power sonar system is compared with directly measured values by photo diodes. The result confirms the adjacency to 0.3% error.

  • PDF

배터리-울트라커패시터 하이브리드 에너지 저장장치를 위한 고효율 전력변환 시스템 (High Efficiency Power Conversion System for Battery-Ultracapacitor Hybrid Energy Storages)

  • 유주승;최우영
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.523-531
    • /
    • 2012
  • This paper proposes a high efficiency power conversion system for battery-ultracapacitor hybrid energy storages. The proposed system has only one bidirectional dc-dc converter for hybrid power source with batteries and ultracapacitors. The hybrid power source has bidirectional switching circuits for selecting one energy storage device. Bidirectional power flow between the energy storage device and high voltage capacitor can be controlled by one bidirectional converter. An asymmetrical switching method is applied to the bidirectional converter for high power efficiency. Switching power losses are reduced by zero-voltage switching of power switches. System operation and design considerations are presented. The experimental results are provided to verify the performance of the proposed system.

동태안정도연구를 위한 반도체 속응여자방식 발전소의 간이전력계통 모형 (Simplified Power System Model of the Generator with the High Speed Solid State Exciter for Dynamic Stability Studies)

  • 한송엽;성세진
    • 전기의세계
    • /
    • 제24권5호
    • /
    • pp.67-71
    • /
    • 1975
  • A dynamic stability analysis of a large interconnected power system takes much time even though the modern large computer is used because of the high order of the system dynamic equations. By the necessity of the low order power system models, a simplified power system model of the generator with the high speed solid state exciter is developed in this paper. The usefulness of the reduced model is confirmed by comparing its eigenvalues and the transient responses with those of the original model in the single machine to infinite bus power system.

  • PDF

Application of Low Voltage High Resistance Grounding in Nuclear Power Plants

  • Chang, Choong-Koo;Hassan, Mostafa Ahmed Fouad
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.211-217
    • /
    • 2016
  • Most nuclear power plants now utilize solid grounded low voltage systems. For safety and reliability reasons, the low voltage (LV) high resistance grounding (HRG) system is also increasingly used in the pulp and paper, petroleum and chemical, and semiconductor industries. Fault detection is easiest and fastest with a solidly grounded system. However, a solidly grounded system has many limitations such as severe fault damage, poor reliability on essential circuits, and electrical noise caused by the high magnitude of ground fault currents. This paper will briefly address the strengths and weaknesses of LV grounding systems. An example of a low voltage HRG system in the LV system of a nuclear power plant will be presented. The HRG system is highly recommended for LV systems of nuclear power plants if sufficient considerations are provided to prevent nuisance tripping of ground fault relays and to avoid the deterioration of system reliability.

고압 고주파 펄스 파워 시스템을 이용한 세균 제거 특성 (The Characteristics on the Removal of Bacteria Using High Voltage and High Frequency Pulsed Power System)

  • 심지영;김미정;박제욱;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1416-1417
    • /
    • 2007
  • The high frequency pulsed power system is widely available for use in high frequency generator applications. We designed and fabricated our own high frequency pulsed power system to obtain very sort pulse width and high peak value and investigated microbe removal characteristics using it. This paper introduces a simple high voltage high frequency pulsed power system for removing various bacteria caused by dirty water. This system include power supply circuit, switching MOSFET, and flyback converter. We can also control the switching using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various bacteria by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.

  • PDF