• Title/Summary/Keyword: High Power Pulse Generator

Search Result 126, Processing Time 0.028 seconds

Study of Pulse Generator used Inverter HV Power Supply (인버터 고전압 전원공급장치를 이용한 펄스전원공급장치 연구)

  • Park S. S.;Kim S. H.;Hwang J. Y.;Nam S. H.;Lee K. T.;Kim H. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.64-67
    • /
    • 2004
  • The klystron-modulator(K&M) system of the Pohang Light Source(PLS) had been supplying high power microwaves for the acceleration of 2.5 GeV electron beams since October 2002. There are 12 sets of K&M systems to accelerate electron beams to 2.5GeV nominal beam energy. One module of the K&M system consists of an 80 MV S-band (2856 MHZ) klystron tube and the matching 200 MW modulator. In order to obtain electron beam of the consequently stability for linac, the pulse-to-pulse beam voltage regulation is less than $+/-0.5\%$. To get the reliable stability of the modulator which is less than $+/-0.5\%$, a charging section is improved in a modulator which has been operated with inverter power supply.

  • PDF

Output Power Control of Permanent Magnet Wind Power Generator with Space Voltage Vector Current Control Strategy (공관전압벡터 전류제어기법을 이용한 영구자석형 풍력발전기의 출력제어)

  • Choi, Jong-Seog;Kim, Si-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.361-364
    • /
    • 2000
  • In this study, the system which can make the generator's output voltage more stable by using the inverter in terms of PWM method, is designed It is one of the method reducing velocity of the wind in the process of the wind power generation. Thus, in this system, it is necessary to use a excellent current control inverter. So pulse with modulation method with a high-speed switching element is introduced to control the output current. And also, in order to get a fast response when the standard current generated by the vector control algorithm is supplied with the generator, the output control system with the fast response character and the best current control character is suggested. In this way, the result from the introduction of the control system is that a response character to the changable velocity of the wind is excellent, causing the remarkable reduction of the percentage of the harmonic and the outstanding stability of the variation of the output voltage.

  • PDF

Implementation of the Radiation Protection Module for Electronic Equipment from Pulsed Radiation and Its Function Tests (펄스방사선에 대한 전자장비 방호용 모듈구현 및 기능시험)

  • Lee, Nam-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1421-1424
    • /
    • 2013
  • The electronic equipment which is exposed to high level pulsed radiation is damaged by Upset, Latchup, and Burnout. Those damages come from the instantaneous photocurrent from electron-hole pairs generated in itself. Such damages appear as losses of a power in military weapon system or as a blackout in aerospace equipment and eventually caused in gross loss of national power. In this paper, we have implemented a RDC(Radiation detection and control module) as a part of the radiation protection technology of the electronic equipment or devices from the pulsed gamma radiation. The RDC, which is composed of pulsed gamma-ray detection sensor, signal processors, and pulse generator, is designed to protect the an important electronic circuits from the a pulse radiation. To verify the functionality of the RDC, LM118s, which had damaged by the pulse radiation, were tested. The test results showed that the test sample applied with the RDC was worked well in spite of the irradiation of a pulse radiation. Through the experiments we could confirm that the radiation protection technology implemented with the RDC had the functionality of radiation protection for the electronic devices.

Utility Interactive Solar Power Conditioner with Zero Voltage Soft Switching High frequency Sinewave Modulated Inverter Link

  • Terai H.;Sumiyoshi S.;Kitaizumi T.;Omori H.;Ogura K.;Chandhaket S.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.668-672
    • /
    • 2001
  • The utility interactive sinewave modulated inverter for the solar photovoltaic (PV) power conversion and conditioning with a new high frequency pulse modulated link is presented for domestic residential applications. As compared with the conventional full-bridge hard switching PWM inverter with a high frequency AC link, the simplest single-ended quasi-resonant soft switching sinewave modulated inverter with a duty cycle pulse control is implemented, resulting in size and weight reduction and low-cost. This paper presents a prototype circuit of the single-ended zero voltage soft switching sinewave inverter for solar power conditioner and its operating principle. In addition, this paper proposes a control system to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed from an experimental point of view. A newly developed interactive sinewave power processor which has $92.5\%$ efficiencty at 4kW output is demonstrated. It is designed 540mm-300mm-125mm in size, and 20kg in weight.

  • PDF

Power Quality Improvement Using Hybrid Passive Filter Configuration for Wind Energy Systems

  • Kececioglu, O. Fatih;Acikgoz, Hakan;Yildiz, Ceyhun;Gani, Ahmet;Sekkeli, Mustafa
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.207-216
    • /
    • 2017
  • Wind energy conversion systems (WECS) which consist of wind turbines with permanent magnet synchronous generator (PMSG) and full-power converters have become widespread in the field of renewable power systems. Generally, conventional diode bridge rectifiers have used to obtain a constant DC bus voltage from output of PMSG based wind generator. In recent years, together advanced power electronics technology, Pulse Width Modulation (PWM) rectifiers have used in WECS. PWM rectifiers are used in many applications thanks to their characteristics such as high power factor and low harmonic distortion. In general, L, LC and LCL-type filter configurations are used in these rectifiers. These filter configurations are not exactly compensate current and voltage harmonics. This study proposes a hybrid passive filter configuration for PWM rectifiers instead of existing filters. The performance of hybrid passive filter was tested via MATLAB/Simulink environment under various operational conditions and was compared with LCL filter structure. In addition, neuro-fuzzy controller (NFC) was preferred to increase the performance of PWM rectifier in DC bus voltage control against disturbances because of its robust and nonlinear structure. The study demonstrates that the hybrid passive filter configuration proposed in this study successfully compensates current and voltage harmonics, and improves total harmonic distortion and true power factor.

Investigations of Multi-Carrier Pulse Width Modulation Schemes for Diode Free Neutral Point Clamped Multilevel Inverters

  • Chokkalingam, Bharatiraja;Bhaskar, Mahajan Sagar;Padmanaban, Sanjeevikumar;Ramachandaramurthy, Vigna K.;Iqbal, Atif
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.702-713
    • /
    • 2019
  • Multilevel Inverters (MLIs) are widely used in medium voltage applications due to their various advantages. In addition, there are numerous types of MLIs for such applications. However, the diode-less 3-level (3L) T-type Neutral Point Clamped (NPC) MLI is the most advantageous due to its low conduction losses and high potential efficiency. The power circuit of a 3L T-type NPC is derived by the conventional two level inverter by a slight modification. In order to explore the MLI performance for various Pulse Width Modulation (PWM) schemes, this paper examines the operation of a 3L (five level line to line) T-type NPC MLI for various types of Multi-Carriers Pulse Width Modulation (MCPWM) schemes. These PWM schemes are compared in terms of their voltage profile, total harmonic distortion (THD) and conduction losses. In addition, a 3L T-type NPC MLI is also compared with the conventional NPC in terms of number of switches, clamping diodes, main diodes and capacitors. Moreover, the capacitor-balancing problem is also investigated using the Neutral Point Fluctuation (NPF) method with all of the MCPWM schemes. A 1kW 3L T-type NPC MLI is simulated in MATLAB/Simulink and implemented experimentally and its performance is tested with a 1HP induction motor. The results indicate that the 3L T-type NPC MLI has better performance than conventional NPC MLIs.

Design of SCR-Based ESD Protection Circuit for 3.3 V I/O and 20 V Power Clamp

  • Jung, Jin Woo;Koo, Yong Seo
    • ETRI Journal
    • /
    • v.37 no.1
    • /
    • pp.97-106
    • /
    • 2015
  • In this paper, MOS-triggered silicon-controlled rectifier (SCR)-based electrostatic discharge (ESD) protection circuits for mobile application in 3.3 V I/O and SCR-based ESD protection circuits with floating N+/P+ diffusion regions for inverter and light-emitting diode driver applications in 20 V power clamps were designed. The breakdown voltage is induced by a grounded-gate NMOS (ggNMOS) in the MOS-triggered SCR-based ESD protection circuit for 3.3 V I/O. This lowers the breakdown voltage of the SCR by providing a trigger current to the P-well of the SCR. However, the operation resistance is increased compared to SCR, because additional diffusion regions increase the overall resistance of the protection circuit. To overcome this problem, the number of ggNMOS fingers was increased. The ESD protection circuit for the power clamp application at 20 V had a breakdown voltage of 23 V; the product of a high holding voltage by the N+/P+ floating diffusion region. The trigger voltage was improved by the partial insertion of a P-body to narrow the gap between the trigger and holding voltages. The ESD protection circuits for low- and high-voltage applications were designed using $0.18{\mu}m$ Bipolar-CMOS-DMOS technology, with $100{\mu}m$ width. Electrical characteristics and robustness are analyzed by a transmission line pulse measurement and an ESD pulse generator (ESS-6008).

A Study of Electron Beam Production for High Pulse Power Generator (대전력 펄스파워의 개발을 위한 전자빔 발생장치 연구)

  • Kim, Won-Sop
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1979-1981
    • /
    • 2004
  • 대전력 펄스 파워를 발생시키기 위한 마이크로파 발진기는 수GW의 대출력이 발생되고 있는데 발진특성, 높은 주파수, 발진출력향상등에 대한 여러 가지 연구가 진행되고 있다, 마이크로파는 지파회로를 이용하면 광속보다도 낮은 주파수를 갖게되며 전자빔과 속도가 일치될 때 에너지의 증대가 일어나 대전력 펄스퐈워를 발생시킬수 있다. 본 연구에서는 회로파의 군속도가 부의 영역에서 동작하는 후진파 발진기를 이론적인 계산에 의하여 연구하였다. 연구는 수십GHz의 주파수를 이용하여 보다 높은 출력, 효율이 발생되도록 하였고 분산특성을 이용하였다.

  • PDF

A study on Driver module for a high-power pulsed laser diode (고출력 펄스 반도체 레이저의 드라이버 모듈에 관한 연구)

  • Jung, In-Suk;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1078-1080
    • /
    • 1999
  • A laser pulse generator which consists of charging resistor, energy storage capacitor laser diode, and switching elements was designed in order to generate 15ns, 20W laser pulses. And the effects of performances of SCR and FET as switching elements are compared. When SCR is used, the SCR's low maximum voltage makes the circuit so complicated, and when FET is used, the FET needs the special sate driver which improves the FET's operation.

  • PDF

Experiment on Small A.C. MHD Power Generator (소용량 교류 MHD발전기에 대한 실험적 연구)

  • Choon Saing Jhoun
    • 전기의세계
    • /
    • v.25 no.5
    • /
    • pp.79-87
    • /
    • 1976
  • This paper is to investigate the A.C generation of MHD engine, converting directly the kinetic energy of conductive gas in high temperature to electric power by the effect of magnetic field. It is known that there are at least two kinds of method in A.C MHD power generation; one, by sending stationary plasma flow in an alternating or rotating magnetic field and the other, by transmission of pulse type plasma flow in uniform and constant magnetic field, former method is adopted here. In order to raise the total efficiency of close cycle in combination with nuclear power and MHD genertaion, an argon plasma jet is utilized as heat source, which is not mixed with the seed material, and the design data are obtained for A.C MHD generation in small capacity, but induced voltage and power output have the maximum values, 15 voltages and 7.5W respectively due to plasma flow with low conductivity and weak magnetic field.

  • PDF