• 제목/요약/키워드: High Power Pulse Generator

검색결과 126건 처리시간 0.041초

자기 펄스 발생기의 연결 도체 설계에 관한 연구 (A Study on the Design of Branch Conductor in the Magnetic Pulse Generator)

  • 서주하
    • 산업기술연구
    • /
    • 제9권
    • /
    • pp.101-107
    • /
    • 1989
  • The magnetic forming system must be able to store very important electric energy, several tens kilojoules, and flow this energy through the forming coil within some hundreds microseconds. So several hundreds kiloamperes of current can flow through the branch conductor. For the good performance of this type of machine, internal impedance must be minimized. By the computation of distribution of current inside the conductors using integral equation method, we can obtain the inductance and resistance of some dispositions of branch conductors and by comparison obtain some principles for the design of branch conductors in the high power magnetic pulse generator.

  • PDF

고압 고주파 펄스 파워 시스템을 이용한 세균 제거 특성 (The Characteristics on the Removal of Bacteria Using High Voltage and High Frequency Pulsed Power System)

  • 심지영;김미정;박제욱;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1416-1417
    • /
    • 2007
  • The high frequency pulsed power system is widely available for use in high frequency generator applications. We designed and fabricated our own high frequency pulsed power system to obtain very sort pulse width and high peak value and investigated microbe removal characteristics using it. This paper introduces a simple high voltage high frequency pulsed power system for removing various bacteria caused by dirty water. This system include power supply circuit, switching MOSFET, and flyback converter. We can also control the switching using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various bacteria by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.

  • PDF

Development of High Flux Metal Ion Plasma Source for the Ion Implantation and Deposition

  • Kim, Do-Yun;Lee, Eui-Wan
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제7권2호
    • /
    • pp.45-56
    • /
    • 2003
  • A high flux metal plasma pulse ion source, which can simultaneously perform ion implantation and deposition, was developed and tested to evaluate its performance using the prototype. Flux of ion source was measured to be 5 A and bi-polar pulse power supply with a peak voltage of 250 V, repetition of 20 Hz and width of 100 ${\mu}\textrm{s}$ has an output current of 2 kA and average power of 2 kW. Trigger power supply is a high voltage pulse generator producing a peak voltage of 12 kV, peak current of 50 A and repetition rate of 20 Hz. The acceleration column for providing target energy up to ion implantation is carefully designed and compatible with UHV (ultra high vacuum) application. Prototype systems including various ion sources are fabricated for the performance test in the vacuum and evaluated to be more competitive than the existing equipments through repeated deposition experiments.

  • PDF

펄스 반복률에 의한 반도체 소자의 오동작 모드와 고장률에 관한 연구 (A Study on Malfunction Mode and Failure Rate Properties of Semiconductor by Impact of Pulse Repetition Rate)

  • 박기훈;방정주;김륙완;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.360-364
    • /
    • 2015
  • Electronic systems based on solid state devices have changed to be more complicated and miniaturized as the electronic systems developed. If the electronic systems are exposed to HPEM (high power electromagnetics), the systems will be destroyed by the coupling effects of electromagnetic waves. Because the HPEM has fast rise time and high voltage of the pulse, the semiconductors are vulnerable to external stress factor such as the coupled electromagnetic pulse. Therefore, we will discuss about malfunction behavior and DFR (destruction failure rate) of the semiconductor caused by amplitude and repetition rate of the pulse. For this experiment, the pulses were injected into the pins of general purpose IC due to the fact that pulse injection test enables the phenomenon after the HPEM is coupled to power cables. These pulses were produced by pulse generator and their characteristics are 2.1 [ns] of pulse width, 1.1 [ns] of pulse rise time and 30, 60, 120 [Hz] of pulse repetition rate. The injected pulses have changed frequency, period and duty ratio of output generated by Timer IC. Also, as the pulse repetition rate increases the breakdown threshold point of the timer IC was reduced.

펄스파워를 이용한 전압 및 주파수 가변에 의한 고효율 RUST (녹) 제거 특성에 대한 연구 (Characteristics of high-efficiency rust removal by adjusting variable frequency and voltage charging using the Pulsed Power system)

  • 송우정;김수원;전진안;정종한;김휘영;김희제
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.180-183
    • /
    • 2002
  • The pulsed power system was widely making use good of many industrial and environments. The pulse generator generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, this system is designed and fabricated which has a compact size of pulse generator with switched MOSFET. We have studied the removal of rust material using Arc discharging. It have tested their characteristics by adjusting variable voltage charging and pulse repetition rate. As a result, We can eliminate rust materials with this device.

  • PDF

인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가 (Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System)

  • 김영표;천민우;박용필
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

고전압 단 펄스 발생장치 제작 (High Voltage Short Pulse Generator System)

  • 최수일;황보승;김규언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1410_1411
    • /
    • 2009
  • 본 연구에서는 고전압·방전, Laser Beam, Plasma 공학분야 등에 있어서 중요한 현상 중의 하나로 대두되고 있는 Pulse Power 현상과 관련하여 고전압 단 펄스 발생장치(Pulse Width =10 ns, Pulse Height = 3kV) 시스템을 제작 하였다.

  • PDF

Utility-Interactive Modulated Sinewave Inverter with a High Frequency Flyback Transformer Link for Small-Scale Solar Photovoltaic Generator

  • Konishi Y.;Chandhaket S.;Ogura K.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.683-686
    • /
    • 2001
  • This paper presents a novel prototype of the utility­interactive voltage source type sinewave pulse modulated power inverter using a high-frequency flyback transformer link. The proposed power conditioner circuit for the solar photovoltaic generation and small scale fuel cell has an isolation function due to the safety of the power processing system, which is more cost effective and acceptable for the small-scale distributed renewal energy conditioning and processing systems. The discontinuous current mode(DCM) of this power processing conversion circuit is applied to implement a simple circuit topology and pulse modulated control scheme. Its operation principle is described on the basis of simulation evaluations and theoretical considerations. The simulation results obtained herein prove that the proposed inverter outputs with sinusoidal waveforms and unity power factor currents are synchronized to the main voltage in utility power source grid. In this paper, the soft switching topology of high­frequency linked sinewave pulse modulation inverter is proposed and discussed.

  • PDF

공정 및 공급전압 변화에 강인한 하프브리지 구동 IC의 설계 (Design of a Robust Half-bridge Driver IC to a Variation of Process and Power Supply)

  • 송기남;김형우;김기현;서길수;장경운;한석붕
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.801-807
    • /
    • 2009
  • In this paper, we propose a novel shoot-through protection circuit and pulse generator for half-bridge driver IC. We designed a robust half-bridge driver IC over a variation of processes and power supplies. The proposed circuit is composed a delay circuit using a beta-multiplier reference. The proposed circuit has a lower variation rate of dead time and pulse-width over variation of processes and supply voltages than the conventional circuit. Especially, the proposed circuit has more excellent pulse-width matching of set and reset signals than the conventional circuit. Also, the proposed pulse generator is prevented from fault operations using a logic gate. Dead time and pulse-width of the proposed circuit are typical 250 ns, respectively. The variation ratio is 68%(170 ns) of maximum over variation of processes and supply voltages. The proposed circuit is designed using $1\;{\mu}m$ 650 V BCD (Bipolar, CMOS, DMOS) process parameter, and the simulations are carried out using Spectre simulator of Cadence corporation.

전자방사식 고압 저전력 방전을 이용한 OH radical 발생기의 개발과 성능 평가 (Development and Performance Evaluation of Hydroxyl Radical Generator using Electron Emission Type High Voltage and Low Current Discharger)

  • 강형섭;홍영표;이인호;김기범
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.558-566
    • /
    • 2017
  • 본 연구는 MOSFET을 이용하여 안정적인 구형파를 구현함과 동시에 순간적인 전류의 상승을 최대한 줄여 전체 회로의 안정성 이 확보된 폐수처리용 전자방사식 OH radical generator를 개발하고자 하였다. 이와 같은 문제를 해결하고 안정성이 확보된 전자방사식 고압 저전력 방전을 이용한 폐수처리용 전자방사식 OH radical generator를 개발하고 그 성능을 평가하고자 하였다. 실험은 2016년 11월부터 2017년 3월까지 실시하였다. 그 결과 AC 체배 변환기의 입력 단에 연결되는 Power MOSFET의 drain 전류는 CR-스너버 구조의 부궤환(negative feedback) 회로를 통해 안정적이고 일정한 펄스 파형을 제공할 수 있었으며 AC 체배 변환기의 여기 전류(excitation current) 감소 및 발진 회로의 안정성을 상승시킬 수 있었다. 또한 이와 같은 회로를 갖는 전자방사식 OH radical generator에서 OH radical을 안정정적으로 발생시킬 수 있었다. 또한 살균능을 평가한 결과, E. coli, S. aureus와 S. flexneri는 60분 후 최대 99.9%이상의 살균력을 보였다. 본 연구 결과를 기반으로, MOSFET을 이용하여 안정적인 구형파를 구현함과 동시에 순간적인 전류의 상승을 최대한 줄여 전체 회로의 안정성이 확보된 살균능이 우수한 폐수처리용 전자방사식 OH radical generator를 개발하였다.