• Title/Summary/Keyword: High Frequency Attenuation

Search Result 237, Processing Time 0.031 seconds

Analysis of inverters for coupling resonators of monoblock dielectric band-pass filter (일체형 유전체 대역 통과 필터의 공진기 결합용 인버터 해석)

  • 강종윤;최지원;심성훈;윤석진;김현재;박창엽
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.191-194
    • /
    • 1999
  • Recently, with the rapid development and demand for compactness of portable communications, the requirement for compact and low-cost filter is increasing. One of the methods for reducing size and cost is to use high dielectric constant and low loss dielectric material in filter. The other is new monoblock dielectric band-pass filter (BPF) which has holes in a single dielectric body without additional coupling elements. This structure effectively reduces the size and cost of the filters. For previous conventional coaxial type dielectric BPF, dielectric substrates were used for coupling between adjacent resonators and additional input and output ports were needed. Coupling between adjacent resonators of monoblock BPF can be otained via electrode pairs. Capacitances of electrode pair structure for coupling are intensively investigated by 3-D FEM. The BPF for PCS has been designed to have a 30 MHz pass-bandwidth with center frequency of 1855 MHz and an attenuation pole at below the passband using a commercial 3-D structure simulator.

  • PDF

Adaptive Sliding Mode Control Synthesis of Maritime Autonomous Surface Ship

  • Lee, Sang-Do;Xu, Xiao;Kim, Hwan-Seong;You, Sam-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.3
    • /
    • pp.306-312
    • /
    • 2019
  • This paper investigates to design a controller for maritime autonomous surface ship (MASS) by means of adaptive super-twisting algorithm (ASTA). A input-out feedback linearization method is considered for multi-input multi-output (MIMO) system. Sliding Mode Controller (SMC) is suitable for MASS subject to ocean environments due to its robustness against parameter uncertainties and disturbances. However, conventional SMC has inherent disadvantages so-called, chattering phenomenon, which resulted from the high frequency of switching terms. Chattering may cause harmful failure of actuators such as propeller and rudder of ships. The main contribution of this work is to address an appropriate controller for MASS, simultaneously controls surge and yaw motion in severe step inputs. Proposed control mechanism well provides convergence bewildered by external disturbances in the middle of steady-state responses as well as chattering attenuation. Also, the adaptive algorithm is contributed to reducing non-overestimated value of control gains. Control inputs of surge and yaw motion are displayed by smoother curves without excessive control activities of actuators. Finally, no overshoot can be seen in transient responses.

Design of a 60 Hz Band Rejection FilterInsensitive to Component Tolerances (부품 허용 오차에 둔감한 60Hz 대역 억제 필터 설계)

  • Cheon, Jimin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.109-116
    • /
    • 2022
  • In this paper, we propose a band rejection filter (BRF) with a state variable filter (SVF) structure to effectively remove the influence of 60 Hz line frequency noise introduced into the sensor system. The conventional BRF of the SVF structure uses an additional operational amplifier (OPAMP) to add a low pass filter (LPF) output and a high pass filter (HPF) output or an input signal and a band pass filter. Therefore, the notch frequency and the notch depth that determine the signal attenuation of the BRF greatly depend on the tolerance of the resistors used to obtain the sum or difference of the signals. On the other hand, in the proposed BRF, since the BRF output is formed naturally within the SVF structure, there is no need for a combination between each port. The notch frequency of the proposed BRF is 59.99 Hz, and it can be confirmed that it is not affected at all by the tolerance of the resistor through the Monte Carlo simulation results. The notch depth also has an average of -42.54dB and a standard deviation of 0.63dB, confirming that normal operation as a BRF is possible. Also, with the proposed BRF, noise filtering was applied to the electrocardiogram (ECG) signal that interfered with 60 Hz noise, and it was confirmed that the 60 Hz noise was appropriately suppressed.

Precise Detection of Buried Underground Utilities by Non-destructive Electromagnetic Survey (비파괴 전자탐사에 의한 지하 매설물의 정밀탐지)

  • Shon, Ho-Woong;Lee, Seung-Hee;Lee, Kang-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.275-283
    • /
    • 2002
  • To detect the position and depth of buried underground utilities, method of Ground Penetrating Radar(GPR) survey is the most commonly used. However, the skin-depth of GPR is very shallow, and in the places where subsurface materials are not homogeneous and are compose of clays and/or salts and gravels, GPR method has limitations in application and interpretation. The aim of this study is to overcome these limitations of GPR survey. For this purpose the site where the GPR survey is unsuccessful to detect the underground big pipes is selected, and soil tests were conducted to confirm the reason why GPR method was not applicable. Non-destructive high-frequency electromagnetic (HFEM) survey was newly developed and was applied in the study area to prove the effectiveness of this new technique. The frequency ranges $2kHz{\sim}4MHz$ and the skin depth is about 30m. The HFEM measures the electric field and magnetic field perpendicular to each other to get the impedance from which vertical electric resistivity distribution at the measured point can be deduced. By adopting the capacitive coupled electrodes, it can make the measuring time shorter, and can be applied to the places covered by asphalt an and/or concrete. In addition to the above mentioned advantages, noise due to high-voltage power line is much reduced by stacking the signals. As a result, the HFEM was successful in detecting the buried underground objects. Therefore this method is a promising new technique that can be applied in the lots of fields, such as geotechnical and archaeological surveys.

High Power Cavity Type Tunable Filter Using Switch for 1.5 GHz Band (Switch를 이용한 1.5 GHz 대역 고출력 Cavity 기반 Tunable Filter)

  • Ahn, Sehoon;Lee, Minho;Park, Jongcheol;Jeong, Gyetaek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In this paper, the tunable filter based on high power cavity using mechanical switch for 1.5 GHz band is presented. The LPF is inserted to eliminate the spurious wave, coupler is embeded to extract the output power, and then the tunable filter system is configured using mechanical switch. The LPF obtains attenuation over 40 dB between 4 GHz and 12.75 GHz, Coupler is satisfied with coupling value 40 dB and coupling isolation over 55 dB. The tunable filter system using mechanical switch obtains insertion loss 0.88 dB at bypass mode between 1,495.9 MHz and 1,510. 9 MHz, 3.29 dB at fil mode between 1,495.9 MHz and 1,500.9 MHz. It is also satisfied with output power of 132 W at the center frequency 1,498.4 MHz, and switching time below 10 ms.

An ICI Canceling 5G System Receiver for 500km/h Linear Motor Car

  • Suguru Kuniyoshi;Rie Saotome;Shiho Oshiro;Tomohisa Wada
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.6
    • /
    • pp.27-34
    • /
    • 2023
  • This paper proposed an Inter-Carrier-Interference (ICI) Canceling Orthogonal Frequency Division Multiplexing (OFDM) receiver for 5G mobile system to support 500 km/h linear motor high speed terrestrial transportation service. A receiver in such high-speed train sees the transmission channel which is composed of multiple Doppler-shifted propagation paths. Then, a loss of sub-carrier orthogonality due to Doppler-spread channels causes ICI. The ICI Canceler is realized by the following three steps. First, using the Demodulation Reference Symbol (DMRS) pilot signals, it analyzes three parameters such as attenuation, relative delay, and Doppler-shift of each multi-path component. Secondly, based on the sets of three parameters, Channel Transfer Function (CTF) of sender sub-carrier number 𝒏 to receiver sub-carrier number 𝒍 is generated. In case of 𝒏≠𝒍, the CTF corresponds to ICI factor. Thirdly, since ICI factor is obtained, by applying ICI reverse operation by Multi-Tap Equalizer, ICI canceling can be realized. ICI canceling performance has been simulated assuming severe channel condition such as 500 km/h, 2 path reverse Doppler Shift for QPSK, 16QAM, 64QAM and 256QAM modulations. In particular, for modulation schemes below 16QAM, we confirmed that the difference between BER in a 2 path reverse Doppler shift environment and stationary environment at a moving speed of 500 km/h was very small when the number of taps in the multi-tap equalizer was set to 31 taps or more. We also confirmed that the BER performance in high-speed mobile communications for multi-level modulation schemes above 64QAM is dramatically improved by the use of a multi-tap equalizer.

A Study of the Dynamic Amplification Characteristics of the Domestic Seismic Observation Sites Using Coda Wave (Coda파를 이용한 국내 관측소지반의 동적 증폭특성에 관한 연구)

  • Kim, Junkyoung;Lee, Jundae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.135-141
    • /
    • 2009
  • For more reliable estimation of soil-structure interaction and seismic source and attenuation properties, site amplification function should be considered. This study use the Nakamura's method (1989) for estimating site amplification though various methods for the same purpose have been proposed. This method was originally applied to the surface waves of background noise and therefore there are some limitation for applications to general wave energy. However, recently this method has been extended and applied to the S wave energy successfully. This study applied the method to the coda wave energy which is equivalent to the backscattered S wave energy. We used more than 60 observed ground motions from 5 earthquakes which occurred recently, with magnitude range from 3.6 to 5.1 Each station showed characteristic site amplification property in low-, high- and resonance frequency ranges. In the case of comparing these results to those from S wave energy, lots of information to the site classification work can be gained. Moreover, removal of site amplification can give us more reliable seismic source parameters.

  • PDF

The Changes of Blood Pressure, Heart Rate and Heart Rate Variability after Stellate Ganglion Block (성상신경절 차단 시 혈압, 맥박수 및 심박수 변이도의 변화)

  • Kweon, Tae Dong;Han, Chung Mi;Kim, So Yeun;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.202-206
    • /
    • 2006
  • Background: Stellate ganglion block (SGB) might be associated with changes in the blood pressure (BP) and heart rate (HR). The heart rate variability (HRV) shows the balance state between sympathetic and parasympathetic activities of the heart. The changes in these parameters of the HRV were studied to evaluate the possible mechanism of SGB in changing the BP. Methods: SGB was performed on 26 patients, using a paratracheal technique at the C6 level, and 8 ml of 1% mepivacaine injected. The success was confirmed by check the Horner's syndrome. The BP, HR and HRV were measured before and 5, 15, 30, 45 and 60 minutes after the SGB. Results: The increases in the BP from the baseline throughout the study period were statistically, but not clinically significant. The HR and LF/HF (low frequency/high frequency) ratio were increased at 5 and 45 min, respectively, after the administration of the SGB. In a comparison of left and right SGB, no significant differences were found in the BP, HR and HRV. A correlation analysis showed that an increased BP was significantly related with the changes in the LF/HF ratio and LF at 15 and 30 minutes, respectively, after the SGB. Dividing the patients into two groups; an increased BP greater and less than 20% of that at the baseline INC and NOT groups, respectively, hoarseness occurred more often in the INC group (P = 0.02). Conclusions: It was concluded that SGB itself does not clinically increase the BP and HR in normal hemodynamic patients. However, the loss of balance between the sympathetic and parasympathetic nerve system, attenuation of the baroreceptor reflex and hoarseness are minor causes of the increase in the BP following SGB; therefore, further studies will be required.

A Study for Change of Audio Data according to Rotation Degree of VR Video (VR 영상의 회전각도에 따른 오디오 데이터 변화에 관한 연구)

  • Ko, Eun-Ji;Yang, Ji-Hee;Kim, Young-Ae;Park, Goo-Man;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1135-1142
    • /
    • 2017
  • In this paper, we propose an algorithm that can automatically mix the screen and sound by tracking the change of the sound data according to the screen change so that the real sound can be implemented in the personal broadcasting service. Since the personal broadcasting service is often broadcasted lively, it should be convenient to have a real-time mixing. Through experiments, it was confirmed that the sound pressure changes in a wide range in the high frequency band related to the clarity for understanding according to the rotation angle change of the screen. Regression analysis of the sound pressure changes at 2kHz, 4kHz, and 8kHz, The attenuation change of sound pressure was observed at the slope of -1.17, the slope of -2.0, and the slope of -2.44 for each frequency. Therefore, these experiment results can be applied to the VR service. This study is expected to be useful data in the implementation of personal broadcasting service.

Experimental Comparison on Vibration Attenuation Performances of the Piezoelectric Mount in Same Geometric Constraints with the Rubber Mount (고무마운트와 동일한 형상 조건을 갖는 압전마운트의 진동저감 성능에 대한 실험적 비교 고찰)

  • Han, Young-Min
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.166-171
    • /
    • 2021
  • An active mount is devised in same geometric constraints with a conventional rubber mount. The proposed mount features the piezoelectric actuator which can be used to reduce the vibration at marine vessels or automotive vehicles. As a first step, a passive rubber mount is adopted and its dynamic characteristics are experimentally evaluated. Based on the geometry of the rubber mount, a rubber element for the active mount is manufactured and integrated with two piezostacks in series, in which the piezostack is operated as an inertial type of actuator. A conventional PID controller featured by the simple and easy implementation, is then designed to attenuate the non-resonant high frequency vibration transmitted from the base excitation. Finally, the control performances of a proposed active mount are evaluated in the wide frequency range and compared with those of the conventional rubber mount.