• 제목/요약/키워드: High Flowrate

검색결과 111건 처리시간 0.018초

Jet 폭기 시스템의 순환유량에 따른 산소전달 특성 및 순산소 적용성 검토 (Oxygen Transfer Characteristics & Pure Oxygen Application Study on Circulation Flow Rate of the JLB (Jet Loop Bioreactor))

  • 박노백;송용효;박준규;전항배
    • 한국물환경학회지
    • /
    • 제25권6호
    • /
    • pp.896-901
    • /
    • 2009
  • In this study, in order to apply the air and pure oxygen in the Jet Loop Reactor (JLB) in which the oxygen transfer rate is high, differentiate the operation mode according to each air flowrate and liquid flowrate and investigate the oxygen transfer characteristic, an experiment was carried out. The oxygen concentration with the air flowrate ($Q_g$) and liquid flowrate ($Q_L$) was identical but the oxygen transfer coefficient ($K_L{\cdot}a$) is linear depending on degree of two factors. The width of an increase is small in $0.1min^{-1}$ when the air flowrate is 0.2 L/min with increasing the liquid flowrate. Whereas, the increment was exposed to be very high for $1.5min^{-1}$ when the air flowrate was 5 L/min. In the experiments using the pure oxygen, it was 30 mg/L of oxygen concentration finally and it was 3.5 times than using the air. But the time reached the saturated concentration was similar to using the air, and $K_L{\cdot}a$ was similar to using the air too. Analysis between two independent variable and oxygen transfer of the correlation is the same model like $K_L{\cdot}a={0.0161Q_L}^{1.5371}{Q_g}^{0.5433}$ using with coefficient non linear regression analysis. It was resulted that the liquid flowrate were approximately three times than air flowrate on effect to oxygen transfer rate.

부자식 유량계의 성능특성에 관한 연구 (A Study on the Performance Characteristics of Float Type Flow Meter)

  • 김춘식;김경근;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.339-347
    • /
    • 1985
  • Precise measurement of flowrate is considered as an important measuring factor in mechanical and chemical experiment. Although there are many methods to measure flowrate, Float type flowmeter is widely used because of its easy attachment to piping and high measuring precision. To design the precise float type flowmeter, much design information such as tapered-tube dimensions, float size, float shape and float material is required. In this paper, fundamental design theory for float type flowmeter according to the given flowrate range is suggested and compensation coefficients of volumetric and weight flowrate for water, R-113 and air are calculated.

  • PDF

순산소 Jet 폭기 시스템을 이용한 음폐수 처리 특성 (Treatment of Food Waste Leachate using Pure-Oxygen Jet Loop Reactor(JLR))

  • 윤애화;박노백;배종훈;전항배;권영배
    • 상하수도학회지
    • /
    • 제24권6호
    • /
    • pp.763-773
    • /
    • 2010
  • The removal efficiencies and a total oxygen transfer coefficient for food waste leachate(FWL) were estimated by using Jet Loop Reactor(JLR). Pure oxygen was used instead of air to improve oxygen concentration in the JLR for high total chemical oxygen demamd(TCOD) in FWL. In JLB, in order to examining the oxygen transfer characteristic, the circulation flowrate and oxygen flowrate were controlled with 7~10 L/min(1.5 L/min interval) and 0.2~0.5 L/min (0.1 L/min interval) and we experimented according to the each condition. As a result, Oxygen uptake rate(OUR) and oxygen transfer rate could be maximized than the oxygen flowrate to increase the circulation flowrate. In addition, it determined that JLR using the pure oxygen which can obtain the greatest oxygen transfer rate as it was the high-concentration organic wastewater like the food waste leachate through the continuous experiment was appropriate.

CO2 가스쿨러용 콤팩트열교환기 개발에 관한 연구(1) -다중관식 헬리컬 코일형 가스냉각기내 CO2의 열유량과 압력강하- (Experimental Study on Compact type CO2 Gas Cooler(1) - Heat Flowrate and Pressure Drop in a Multi-Tube-In-Tube Helical Coil Type Gas Cooler -)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.30-36
    • /
    • 2010
  • 다중관식 헬리컬 코일형 가스냉각기내 $CO_2$의 열유량과 압력강하에 대해서 실험적으로 조사하였다. $CO_2$와 냉각수의 유량은 각각 0.06~0.075kg/s이고, 가스냉각기의 냉각압력은 8~10 MPa이다. $CO_2$의 열유량은 냉각수 질량유량, $CO_2$의 질량유량과 냉각압력에 비례하여 증가한다. $CO_2$의 압력강하는 냉각수와 $CO_2$의 질량유량이 감소할수록 감소하지만, $CO_2$의 냉각압력이 증가할수록 감소한다. 다중관식 헬리컬 코일형 가스냉각기내 $CO_2$의 열유량과 압력강하는 각각 이중관식 가스냉각기보다 상당히 높게 또는 낮게 나타났다. 따라서 다중관식 헬리컬 코일형 가스냉각기에 $CO_2$를 적용하는 경우에는 가스냉각기의 고효율화, 고성능화, 컴팩트화가 가능할 것이다.

플로팅 링 실의 길이와 높이 효과에 따른 누수 및 안정성에 대한 해석과 실험의 비교 (Comparisons between Analysis and Experiment for Leakage Flowrate and Stability depending on the Effect of the Height and the Length of Floating Ring Seal)

  • 안경민;이용복;김창호;하태웅
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.329-336
    • /
    • 2004
  • The lock-up position of the floating ring seal affects the leakage flowrate and the stability. And it is changed depending on the operating and geometry condition. In this paper, the leakage flowrate and stability with change of the height and length were investigated by theoretical analysis and experiment. The parameter of the height and length is expressed to the b and L. The decreasing of the b resulted in the increasing of equivalent whirl frequency ratio in the experimental result at the low speed and high pressure not such as theoretical analysis. As the L increased the leakage flowrate decreased and stiffness and direct damping coefficient increased in the experimental result. That was similar to the theoretical analysis.

  • PDF

무강우시 합류식 하수관거의 오염부하 특성 (Characteristics of Pollution Loads from the Combined Sewer during Dry Season)

  • 원철희;최용훈;박운지;신민환;최중대
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.137-144
    • /
    • 2011
  • We have examined the pollutant load of combined sewer in dry days. Two monitoring sites (C-1, C-2) were equipped with an flowmeter. Monitoring was conducted from September 2004 to April 2006 for 20 months during dry days. Flowrate and concentration of pollutants are lowest from 3 to 6 o'clock, and it is high at 9, 12 and 21 o'clock. Most of organic matters exist in the dissolved state. The results show that pollution loads in C-2 area were 4.5-7.2 times higher than in C-1. Pollutant loads were high on Saturdays. Pollutant loads (kg/ha/day) of C-2 were 1.1-3.1 times higher those of C-1. However there was no significant difference in winter. Analysis of correlation coefficient of water quality parameter indicates that besides of flowrate all items in C-1 site have tight relationship respectively (p<0.01). In C-2 site, correlation coefficient of TP-SS, TP-TN, TP-flowrate, BOD-flowrate, BOD-SS and TN-TP are statistically significant (p<0.01).

도시 소하천 합류부 수심변화에 대한 실험연구 (Experimental Study on the Depth-Variations of Confluence Area in Small Urban Channel)

  • 심기오;이길춘
    • 물과 미래
    • /
    • 제28권3호
    • /
    • pp.197-204
    • /
    • 1995
  • 인구의 도시집중으로 인하여 유역의 유출용적이 증대하며 이로 인한 합류부의 수위상승으로 내수배제가 불가능하게 되어 침수피해가 발생하고 있다. 본 실험연구에서는 소유역 하천에서 우수거의 합류로 인한 본류하천의 흐름변화를 실험하였으며, 하천의 수위상승을 소하천(본류)의 유량과 경사, 우수거(지류)의 유량과 경사 및 합류각에 따른 본류의 수위상승을 분석하였다. 실험결과 본류하천의 경사에 대해서는 경사가 급할수록 수심비가 증대하는 것으로 나타났으며, 본류의 유량은 적을수록, 지류의 유량은 많을 수록 수심비는 크게 나타났다. 합류각에 대해서는 합류각이 작을수록 수심비가 작은값을 나타내고 있다. 이와 같이 도시 소하천의 합류시 수심비의 상승영향을 보면 합류각, 지류유량 및 본류유량 등의 순으로 상승영향이 밀접하게 나타났다.

  • PDF

CO2 가스쿨러용 콤팩트열교환기 개발에 관한 연구(2) - 열유량과 압력강하에 관한 실험 및 예측 - (Experimental Study on Compact type CO2 Gas Cooler(2) - Experiments and Predictions on Heat Flowrate and Pressure Drop -)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.259-266
    • /
    • 2010
  • 다중관식 헬리컬 코일형 가스냉각기내 $CO_2$의 열유량과 압력강하는 LMTD 방식을 이용하여 예측하였고 그 결과를 실험값과 비교하였다. $CO_2$와 냉각수의 유량은 각각 0.06~0.075 kg/s이고, 가스냉각기의 냉각압력은 8~10 MPa이다. 초임계 $CO_2$의 냉각시의 열유량과 압력강하는 LMTD 방식을 이용하여 예측하였고, 이때 냉매측 열전달과 압력강하식은 각각 Gnielinski와 Dittus-Boelter 식을 사용하였다. LMTD법으로 예측한 값과 실험값을 비교한 결과, $CO_2$의 열유량과 압력강하는 상대적으로 좋은 일치를 보였다.

내경 1.77 mm의 다중관식 가스냉각기내 CO2 전열 성능에 대한 실험적 연구 (Experimental Study on Heat Transfer Performance of CO2 in a Multi-Tube Type Gas Cooler of Inner Diameter Tube of 1.77 mm)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.439-444
    • /
    • 2008
  • The heat capacity and pressure drop of $CO_2$ and coolant in a multi-tube type gas cooler were investigated experimentally. The main components of the refrigerant loop are a receiver, a $CO_2$ compressor, a mass flow meter, an evaporator and a multi-tube type gas cooler as a test section. The mass flowrate of $CO_2$ and coolant were varied from 0.06 to 0.075 [kg/s], respectively and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The heat capacity of $CO_2$ in the test section is increased with the increment in mass flowrate of coolant, the cooling pressure and mass flowrate of $CO_2$. The pressure drop of $CO_2$ is decreased with the decrease in mass flowrate of coolant and $CO_2$, but decreased with increase in cooling pressure of $CO_2$. The heat capacity of $CO_2$ per unit heat transfer area of gas cooler is greatly high. Therefore, in case of the application of $CO_2$ at the multi-tube type gas cooler, it is expected to carry out the high-efficiency, high-performance and compactness of gas cooler.

수치모형에 의한 토양증기추출법의 제거효율에 관한 연구 - 차단벽, 추출유량, 펌프가동방법의 영향 - (A Study on the Removal Efficiency of the Soil Vapor Extraction by Numerical Simulation)

  • 이창수
    • 한국수자원학회논문집
    • /
    • 제32권2호
    • /
    • pp.121-129
    • /
    • 1999
  • 본 연구는 토양 및 지하수 오염의 정화방법으로써 토양증기 추출법을 이용할 경우, 이의 효율적 운용을 위하여 추출공 주변에 차단벽을 설치할 경우, 추출펌프유량의 크기 및 펌프가동의 형태 등이 제거효율에 미치는 영향을 평가하기 위하여 수치해석을 이용하여 검토하였다. 그 결과 추출공 주위에 차단벽을 설치할 경우 및 추출펌프의 운용을 단속적으로 실시하였을 경우, 추출공 주변에 고농도의 가스분포를 밀집시킴으로 인해 고농도의 가스를 제거할 수 있게 되어 제거율이 상승하였다. 추출유량의 크기변화가 TCE가스의 제거율에 미치는 영향을 추출유량이 클수록 상승하지만 TCE가스의 정화효율은 추출유량의 크기에는 의존하지 않는다는 것을 알 수 있었다.

  • PDF