• Title/Summary/Keyword: High Energy X-ray

Search Result 1,151, Processing Time 0.03 seconds

MATERIAL INVESTIGATION AND ANALYSIS USING CHARACTERISTIC X-RAY

  • Oh, Gyu-Bum;Lee, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.426-433
    • /
    • 2010
  • The characteristic X-rays emitted from materials after gamma ray exposure was simulated and measured. A CdTe semiconductor detector and a $^{57}Co$ radiation source were used for energy spectroscopy. The types of materials could be identified by comparing the measured energy spectrum with the theoretical X-ray transition energy of the material. The sample composition was represented by the $K_{\alpha1}$-line (Siegbahn notations), which has the highest intensity among the characteristic X-rays of each atom. The difference between the theoretic prediction and the experimental result of K-line measurement was < 0.61% even if the characteristic X-rays from several materials were measured simultaneously. 2D images of the mixed materials were acquired with very high selectivity.

Development of state-of-the-art detectors for X-ray astronomy

  • Lee, Sang Jun;Adams, J.S.;Audley, H.E.;Bandler, S.R.;Betancourt-Martinez, G.L.;Chervenak, J.A.;Eckart, M.E.;Finkbeiner, F.M.;Kelley, R.L.;Kilbourne, C.A.;Porter, F.S.;Sadleir, J.E.;Smith, S.J.;Wassell, E.J.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.53.3-54
    • /
    • 2015
  • We are developing large arrays of X-ray microcalorimeters for applications in X-ray astronomy. X-ray microcalorimeters can detect the energy of X-rays with extremely high resolution. High-resolution Imaging spectroscopy enabled by these arrays will allow us to study the hot and energetic nature of the Universe through the detection of X-rays from astronomical objects such as neutron stars or black holes. I will introduce the state-of-the-art X-ray microcalorimeters being developed at NASA/GSFC and the future X-ray observatory missions based on microcalorimeters.

  • PDF

The energy spectrum and phantom image quality according to mammography target-filter combinations (유방촬영장치의 타깃에 따른 에너지스펙트럼 및 팬텀영상화질)

  • Jang, Seyoung;Oh, Wanggyun;Park, Jongbae;Jin, Gyehwan
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2013
  • When the X-ray energy is high, the X-ray penetrates the object and decrease the contrast of imaging, and when the X-ray energy is low, the X-ray increases the contrast of imaging but it is to be absorbed into the object, which in the long run increases patient's radiation exposure level. Therefore, appropriate X-ray energy is an essential element affecting the imaging quality and radiation exposure level. This study simulated the energy spectrums according to the target materials of mammography, and compared qualities of phantom imaging for the management of radiolographic quality and patient's radiation exposure level with the introduction of the mammography that employs diversified radiation quality by using new anode materials.

A study on thermal fluid analysis in X-ray tube for non-fire alarm (비화재보를 위한 X-ray tube 내 열 유동해석에 관한 연구)

  • Yun, Dong-Min;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.33-38
    • /
    • 2022
  • Currently, Korea is an aging society, and it is expected to enter a super-aging society in about 4 years. Accordingly, many X-ray technologies are being developed. In X-rays, 99% of X-rays are converted into heat energy and 1% into light energy (X-rays). 99% of the thermal energy raises the temperature of the anode and its surroundings, and the cooling system is an important factor as overheating can affect the deterioration of X-ray quality and shortened lifespan. There is a method of forced air cooling using natural convection. Therefore, in this study, when X-rays were taken 5 times, Flow analysis was performed on heat removal according to temperature rise and cooling time for the heat generated at the anode of the X-ray tube (input power 60kW, 75kW, 90kW). Based on one-shot, the most rapid temperature rise section increased by more than 57% to 0.03 seconds, A constant temperature rises from 0.03 seconds to 0.1 seconds, It is judged that the temperature rises by about 8.2% or more at one time. After one-shot cooling, the cooling drops sharply from about 60% to 0.03 seconds, It is judged that the temperature has cooled by more than 86% compared to the temperature before shooting. One-shot is cooled by more than 86% with cooling time after 0.1 seconds, As the input power of the anode increases, the cooling temperature gradually increases. Since the tungsten of the anode target inside the X-ray tube may be damaged by thermal shock caused by a rapid temperature rise, an improvement method for removing thermal energy is required when using a high-input power supply.

A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator (인버터식 X선장치의 관전압 맥동율 개선에 관한 연구)

  • 이성길;임홍우;조금배;정수복;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.

  • PDF

Estimated spectrum of a 6MV X-ray (Laplace transform 방법에 의한 x-ray의 에너지 스펙트럼 추정)

  • Yoo, Myung-Jin
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.37-47
    • /
    • 1993
  • The quality of radiation for a high energy x-ray beam can be specified by its attenuation curve in a selected material. The inverse Laplace transform of the attenuation curve can be used as an approximate indication of the energy spectrum of the beam. We have made a comparative investigation of the estimated spectrum obtained by the Laplace transform analysis of the transmitted exposure data measured in an absorption study of a 6MV x-ray beam. Two of existing transform pair models have been investicated and discussed.

  • PDF

Microscopic Analysis of High Lithium-Ion Conducting Glass-Ceramic Sulfides

  • Park, Mansoo;Jung, Wo Dum;Choi, Sungjun;Son, Kihyun;Jung, Hun-Gi;Kim, Byung-Kook;Lee, Hae-Weon;Lee, Jong-Ho;Kim, Hyoungchul
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.5
    • /
    • pp.568-573
    • /
    • 2016
  • We explore the crystalline structure and phase transition of lithium thiophosphate ($Li_7P_3S_{11}$) solid electrolyte using electron microscopy and X-ray diffraction. The glass-like $Li_7P_3S_{11}$ powder is prepared by the high-energy mechanical milling process. According to the energy dispersive X-ray spectroscopy (EDS) and selected area diffraction (SAD) analysis, the glass powder shows chemical homogeneity without noticeable contrast variation at any specific spot in the specimen and amorphous SAD ring patterns. Upon heating up to $260^{\circ}C$ the glass $Li_7P_3S_{11}$ powder becomes crystallized, clearly representing crystal plane diffraction contrast in the high-resolution transmission electron microscopy image. We further confirm that each diffraction spot precisely corresponds to the diffraction from a particular $Li_7P_3S_{11}$ crystallographic structure, which is also in good agreement with the previous X-ray diffraction results. We expect that the microscopic analysis with EDS and SAD patterns would permit a new approach to study in the atomic scale of other lithium ion conducting sulfides.

Introduction to Properties of Galactic-X-ray Sources

  • Choi, Chul-Sung;Min, Kyoung-W.;Kim, Tu-Hwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.5 no.2
    • /
    • pp.143-158
    • /
    • 1988
  • Since the successful observation by Uhuru, the first astronomical satellite, X-ray astronomy has become one of the rapidly developing fields in astronomy. The scientific results provide us the unique opportunity to understand the high energy nature of X-ray sources. We now know that our galaxy contains many different types of X-ray sources such as the compact X-ray sources, galactic bulge sources in addition to the Sun, the brightest X-ray sources in the sky. In this study we review the general properties of galactic X-ray sources, the characteristics of periodic compact X-ray sources, and bursters as well as the models.

  • PDF

X-ray properties of PWNe measured with the NuSTAR telescopes

  • An, Hongjun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.43.1-43.1
    • /
    • 2018
  • Young pulsar wind nebulae, powered by energetic central pulsars, are often observed as bright extended sources in the X-ray band. They are believed to accelerate electrons and positrons to very high energy and can possibly explain the positron excess observed by Fermi and AMS. The electron distribution in these PWNe can be best studied by X-ray satellites because emission in the X-ray band is produced by direct synchrotron radiation of the electrons and positrons. We present NuSTAR studies of PWNe and discuss the implication. Future studies to help further our understanding of particle acceleration will be briefly discussed.

  • PDF

KCl Crystal Growth and High Energy X Ray Expose of Properties (KCl 단결정의 성장 및 고 에너지 X선 조사 특성)

  • Park, Cheol-Woo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • Purpose: X ray irradiates material for dose distribution confirmation through material color variation to evaluate about possibility. Materials and Methods: That is rare earth material to pure KCl and KCl impurity Eu adding 0.5mol% by Czochralski method each single crystal grow and observed color variation of KCl X ray irradiation use of linear accelerator. Results: High energy X ray irradiation KCl:Eu show the blue fluorescence with purple color that pure KCl single crystal can confirm by show was not observed, but was colored violet. Conclusion: Colors variation of KCl founds stable color center from radiation and this color variation will be used usefully to X ray measurement material and phantom.

  • PDF