• Title/Summary/Keyword: High Energy Photon

Search Result 235, Processing Time 0.029 seconds

The Roles of Gold Plate (140${\mu}{\textrm}{m}$) Loaded on TLD-100 Chips in the High Energy Radiation Beams (고에너지 광자선속에서 TLD-100 chip 위에 있는 금박막(140 ${\mu}{\textrm}{m}$) 역할)

  • Vahc, Young-Woo;Park, Kyung Ran.
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.51-60
    • /
    • 1995
  • Lithium Fluoride (LiF; TLD-100) crystal chips are normally used as thermolu minescence dosimeters (abbreviated as NC-100) for estimating the absorbed dose to the skin of a patient or in a solid water phantom undergoing radiotherapy with megavoltage photon (6 and 15MV) beams. In general, investigation has revealed a reduction in the sensitivity of NC-100 chips after many runs through heating cycles. A TLD-100 chip laminated with gold plate (140${\mu}{\textrm}{m}$) on the upper surface layer of its face toward the photon beam (abbreviated as GC-100) has properties different from that of a NC-100 chip activated by incident photons and contaminant electrons with various lower energies coming from the gantry head and air. Activation of the valence band electrons of GC-100 chips by incident photons, positrons and electrons-which come from the gold plate by mainly pair production process and partly from Compton scattering-results in more enhanced signal intensity, higher response per monitor unit, as well as a good linearity with monitor units and independence of dose rate. Since the electron beams (6 and 15 MeV) do not have the probability of pair production process with gold plate, there is only a small difference (about a 3.3% increase for 15 MeV) in the signal gaps in the TL readout for electron beams between GC- and NC-100 chips. The 3.3% increase is entirely due to the buildup caused by the 140 m gold plate. The sensitivity of GC-100 chips is much more susceptible to high energy photon beams than electron one because of pair production. The interaction of high energy photon with a material of high atomic number, such as the good plate in this case, results in a considerably significant probability of pair production. The gold plate on the NC-100 chips acts as not only an intensifier of their signals but also acts as a filter of contaminant electrons in therapeutic high energy X-ray beams.

  • PDF

An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants (원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.176-183
    • /
    • 2009
  • Maintenance on the water chamber of steam generator during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, characteristic analysis of inhomogeneous radiation fields for contact operations was conducted using thermoluminescent dosimeter (TLD) readouts from the application tests of two-dosimeter algorithm to Korean NPPs in 2004. It is regarded that inhomogeneous radiation fields for contact operations in NPPs are dominated by high energy photons. In addition, field tests for workers who participated in maintenance on the steam generator during outage at Ulchin NPPs in 2009 and pressure tube replacement at Wolsong NPPs in 2009 were conducted to analyze radiation fields and to estimate the extremity dose. As a result, radiation fields were dominated by high energy photons.

Neutron Generation from a 24 MV Medical Linac (24 MV 의료용 선형가속기의 중성자 발생에 관한 연구)

  • Jeong Dong Hyeok;Kang Jeong Ku;Lee Jeong Ok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • The energy spectra and dose calculations were performed for secondary neutrons from a 24 MV LINAC using MCNPX code (V2, 4, 0). The energy spectra for neutrons and photons emitted from the LINAC head, and absorbed dose to water were calculated in water phantom. The absorbed doses calculated with Monte Carlo were $0.66\~0.35$ mGy/photon Gy at the surface to d=5 cm, and calculated with interaction data was 0.52 mGy/photon Gy at the depth of electron equilibrium in water. We have shown that this work can be applied to dose estimation of neutrons from high energy LINAC through the comparison of our results with other results.

  • PDF

A feasibility study on photo-production of 99mTc with the nuclear resonance fluorescence

  • Ju, Kwangho;Lee, Jiyoung;ur Rehman, Haseeb;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.176-189
    • /
    • 2019
  • This paper presents a feasibility study for producing the medical isotope $^{99m}Tc$ using the hazardous and currently wasted radioisotope $^{99}Tc$. This can be achieved with the nuclear resonance fluorescence (NRF) phenomenon, which has recently been made applicable due to high-intensity laser Compton scattering (LCS) photons. In this work, 21 NRF energy states of $^{99}Tc$ have been identified as potential contributors to the photo-production of $^{99m}Tc$ and their NRF cross-sections are evaluated by using the single particle estimate model and the ENSDF data library. The evaluated cross sections are scaled using known measurement data for improved accuracy. The maximum LCS photon energy is adjusted in a way to cover all the significant excited states that may contribute to $^{99m}Tc$ generation. An energy recovery LINAC system is considered as the LCS photon source and the LCS gamma spectrum is optimized by adjusting the electron energy to maximize $^{99m}Tc$ photo-production. The NRF reaction rate for $^{99m}Tc$ is first optimized without considering the photon attenuations such as photo-atomic interactions and self-shielding due to the NRF resonance itself. The change in energy spectrum and intensity due to the photo-atomic reactions has been quantified using the MCNP6 code and then the NRF self-shielding effect was considered to obtain the spectrums that include all the attenuation factors. Simulations show that when a $^{99}Tc$ target is irradiated at an intensity of the order $10^{17}{\gamma}/s$ for 30 h, 2.01 Ci of $^{99m}Tc$ can be produced.

Current Progress in Fabrication of Ta and Nb based STJs for an Astronomical Detector

  • Yoon, Ho-Seop;Park, Young-Sik;Park, Jang-Hyun;Yang, Min-Kyu;Lee, Jeon-Kook;Chong, Yon-Uk;Lee, Yong-Ho;Lee, Sang-Kil;Kim, Dong-Lak;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.37.3-37.3
    • /
    • 2008
  • STJ(Superconducting Tunnel Junction) technique offers next generation photon detectors exhibiting high energy resolution, high quantum efficiency and photon counting ability over the broad wavelength range from X-ray to NIR. We report the succcess in fabrication of Ta/Al-AlOx-Al/Ta and Nb/Al-AlOx-Al/Nb micro structure deposited on sapphire substrates using various techniques including UV photolithography, DC Sputtering, RIE, and PECVD technique. The characterization experiment was undertaken in an Adiabatic Demagnetization Refrigerator at an operating temperature below 50mK. The details of experimental investigations for electrical characterization of STJ of $20\sim80{\mu}m$ in side-lengths are discussed. The measured I-V curves were used to derive The detector performance indicators such as energy gap, energy resolution, normal resistance, normal resistivity, dynamic resistance, dynamic resistivity, and quality factor.

  • PDF

[ $a-Si:H/{\mu}c-Si:H$ ] thin-film tandem solar cells (비정질/마이크로 탠덤 구조형 실리콘 박막 태양전지)

  • Lee, Jeong-Chul;Song, Jin-Soo;Yoon, Kyung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.228-231
    • /
    • 2006
  • This paper briefly introduces silicon based thin film solar cells: amorphous (a-Si:H), microcrystalline ${\mu}c-Si:H$ single junction and $a-Si:H/{\mu}c-Si:H$ tandem solar cells. The major difference of a-Si:H and ${\mu}c-Si:H$ cells comes from electro-optical properties of intrinsic Si-films (active layer) that absorb incident photon and generate electron-hole pairs. The a-Si:H film has energy band-gap (Eg) of 1.7-1.8eV and solar cells incorporating this wide Eg a-Si:H material as active layer commonly give high voltage and low current, when illuminated, compared to ${\mu}c-Si:H$ solar cells that employ low Eg (1.1eV) material. This Eg difference of two materials make possible tandem configuration in order to effectively use incident photon energy. The $a-Si:H/{\mu}c-Si:H$ tandem solar cells, therefore, have a great potential for low cost photovoltaic device by its various advantages such as low material cost by thin-film structure on low cost substrate instead of expensive c-Si wafer and high conversion efficiency by tandem structure. In this paper, the structure, process and operation properties of Si-based thin-film solar cells are discussed.

  • PDF

Energy Dependancy of the Polyethylene Terephthalate Film for Radiation Detector (방사선 검출기용 PET 박막의 에너지 의존성)

  • Back, Geum-Mun;Kim, Keon-Chung;Kim, Wang-Gon;Hong, Jin-Woong;Yi, Byong-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.71-74
    • /
    • 2002
  • Currently small and accurate dosimeters are on the rise. In this study, the feasibility and energy dependency of the electret dosimeter that made of PET (polyethylene terephtalate) were observed by irradiating 4, 6, 15 MV photon beams from the clinical linear accelerator to develop a dosimeter for the clinical field. $10{\times}10cm$ field size of the photon beams were irradiated to the electret dosimeter where the 2.5 cm depth in the polystylene phantom from 100 cm SSD, while 300 DCV was applied to the electret dosimeter. The result showed that the absorbed dose was proportional to the charge linearly, and the volume of a dosimeter could be reduced and the signals were high enough. According to this study, it was found that the polymer electret detector could be produced as a large quantity with a small cost and showed the feasibility of a realtime measurement.

  • PDF

High Power Lasers and Their New Applications

  • Izawa, Yasukazu;Miyanaga, Noriaki;Kawanaka, Junji;Yamakawa, Koichi
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Recent progress in high power lasers enables us to access a regime of high-energy-density and/or ultra-strong fields that was not accessible before, opening up a fundamentally new physical domain which includes laboratory astrophysics and laser nuclear physics. In this article, new applications of high-energy and ultra-intense laser will be reviewed.

A Study on the Neutron Dose Distribution in Case of 10 MV X-rays Radiotherapy (10MV X선 방사선 치료 시 중성자 선량 분포에 관한 연구)

  • Park, Cheol-Soo;Lim, Cheong-Hwan;Jung, Hong-Ryang;Shin, Seong-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.415-417
    • /
    • 2008
  • This study is to measure the radiation dose of neutrons generated by the particle accelerator during X-ray (photon) treatment with a neutron detection method by using CR-39, and to research how the generation of neutrons may incur problems associated with radiation doses for patient treatment when using high energy photons for cancer treatment as a clinical application. The findings are summarized as follows : The results showed that average 0.35mSv was measured with exposure of 1Gy photon in case of fast neutron, 0.65mSv with exposure of 2Gy photon, 1.82mSv exposure of 5Gy, 0.26mSv with exposure of 1Gy photon in case of thermal neutron, 0.56mSv with exposure of 2Gy photon, and 1.23mSv with exposure of 5Gy of photon. By measuring the occurrence of neutron by using Wedge Filter, it has been confirmed that the occurrence of neutrons increased when using Wedge Filter. The results also showed that more neutrons were detected over the existing experiments when using an SRS Cone requiring high doses of radiation. Total 2.85mSv neutrons were found on the average with exposure of 5Gy photon in case of fast neutron and 1.37mSv neutrons were found on the average with exposure of 5Gy photon in case of thermal neutron. During the general treatment, about 1.6 times more neutrons over 5Gy photon were found in case of fast neutron and about 1.12 time more neutrons over 5Gy photon were found in case of thermal neutron.

  • PDF

Study of The Anisotropy of Electron Energy Distribution of Optical-Field Ionized Oxygen Plasma by Using Polarization Spectroscopy

  • Kim, Dong-Eon;Kim, Jae-Hoon;Kawachi, Tetsuya;Hasegawa, Noboru;Sukegawa, Kouta;Iwamae, Atsushi;Fujimoto, Takashi
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.145-149
    • /
    • 2003
  • The anisotropy of electron energy distribution in oxygen plasmas produced by a high intensity laser was investigated by using polarization spectroscopy. An ultra-short pulsed laser with a pulse duration of 66.5 fs and a power density of $1 {\times} 10^17/ W/$\textrm{cm}^2$$ was used. At this power density and pulse duration, the plasma was generated predominantly by optical field ionization. The degree of polarization of OVI 1s$^2$2p$^2$p2- 1s$^2$4d$^2$D$^{0}$ (J = 1/2-3/2 and 3/2-5/2) transition line at 129.92 $\AA$ was measured. O VI 1s$^2$2p$^2$P$^2$ -1s$^2$4s$^2$S$^2$ (J = 1/2-1/2 and 3/2-1/2) transition line at 132.26 $\AA$ was used to calibrate the sensitivity of the optical system. The dependencies of the degree of polarization on the initial gas density and on the laser polarization were investigated. When the laser polarization was changed from a linear to a circular polarization, the degree of polarization was decreased. When the initial gas density was increased, the degree of polarization was decreased.