• Title/Summary/Keyword: Hib

Search Result 35, Processing Time 0.035 seconds

Gamma camera/MR dual imaging liposome labeled with radioisotope and paramagnetic ions

  • Kim, Youn Ji;Kim, Jonghee;Lee, Woonghee;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • Liposomes are defined as spherical, self-closed structures formed by lipid bilayers containing aqueous phase. Most liposomes are composed of various amphipathic lipids such as phospholipids and cholesterol. We used amphipathic lipids (DPPC, DPPG) as liposome components and prepared around 100 nm liposomes by standard extrusion method. Nuclear/MR dual imaging agents based on liposome platform were prepared by adding radioactive $^{131}I$-HIB (hexadecyl-4-tributylstannylbenzoate) and Gd-DTPA into liposome bilayer and inside liposome, respectively. Gamma camera and MR imaging both showed signal increases in liver.

Effect of Different Periods of Cold Storing of Bivoltine Eggs on Subsequent Generation Rearing Performance

  • Venkatesh, H.;Raghuraman, R.;Katti, S.R.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.9 no.2
    • /
    • pp.269-272
    • /
    • 2004
  • Different methods of cold storing of bivoltine eggs are in practice to postpone hatching. Bivoltine eggs undergo hibernation if they are not acid treated within 20 - 24 hrs of oviposition, which depends on race, ambient temperature and humidity. The schedules adopted for cold storing include hibernation schedule (Hib), ordinary chilling (OC), short term chilling (STC) and acid treated layings (AT). Peanut cocooning race ${NB_4}{D_2}$ has been subjected for the present assessment. Cocoons harvested from the crop pertaining to all the four methods of cold storing have been used for producing different combinations and acid treated followed by rearing. The performance in respect of chawki loss, maximum larval weight 4({5^th} age)$, yield/ 10,000 larvae (no), cocoon and shell weight showed maximum values for hibernation ${\times}$ hibernation combination followed hibernation with OC and hibernation with AT. Lowest performance was recorded when STC batch source females were used.

Vaccine Evaluation Studies Performed in Korea from 2000 to 2014 (2000-2014년 한국에서 수행된 백신 유용성 평가 연구)

  • Cha, Jihei;Kim, Han Wool;Lee, Soyoung;Cho, Hye Kyung;Ahn, Jong Gyun;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.2
    • /
    • pp.117-127
    • /
    • 2016
  • Purpose: Vaccine evaluation studies were initiated from 2000 by the Ministry of Food and Drug Safety to produce proper data about the safety and immunogenicity of vaccines. The purpose of this study was to review studies and reports on evaluation of vaccine such as immunogenicity, efficacy, effectiveness, safety and other related topics in order to find and analyze the data on the usefulness of each vaccine. Methods: From 2000 to 2014, the project "The vaccine evaluation" had been performed by several researchers, and studies and reports of vaccine evaluation. We reviewed the results and outcomes of studies regarding the evaluation of vaccine's usefulness and analyzed the possibilities of applying these data for establishing vaccine policies. For each vaccine, data analysis and organization were done according to evaluation fields. Results: A total of 83 studies were performed on vaccines from 2000 to 2014. For each vaccine, 8 studies were performed on BCG, 14 on DTaP/Td, 1 on poliovirus, 5 on Hib, 3 on pneumococcus, 11 on influenza, 3 on hepatitis A, 11 on MMR, 11 on varicella, and 16 on Japanese encephalitis. All studies were analyzed by the following evaluation area, such as safety, immunogenicity, seroprevalence, persistence of immunity, efficacy, effectiveness, vaccine evaluation methods, quality control product for vaccine, and others. Conclusions: Vaccine evaluation studies performed in Korea may be useful as references for establishing vaccination strategy and policy and could be used as baseline data for future studies on vaccine evaluation, vaccine policy establishment, and public/expert vaccine education in Korea.

ION BEAM AND ITS APPLICATIONS

  • Koh, S.K.;Choi, S.C.;Kim, K.H.;Cho, J.S.;Choi, W.K.;Yoon, Y.S.;Jung, H.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.110-114
    • /
    • 1997
  • Development of metal ion source growth of high quality Cu metal film formation of non-stoichiometric $SnO_2$ films of Si(100), and modification fo polymer surface by low enregy ion beam have been carried out at KIST Ion Beam Lab. A new metal ion source with high ion beam flux has been developed by a hybrid ion beam (HIB) deposition and non-stoichiometric $SnO_2$ films are controlled by supplying energy. The ion assisted reaction (IAR) in which keV ion beam is irradiated in reactive gas environment has been deveolped for modifying the polymers and enhancing adhesion to other materials and advantages of the IAR have been reviewed.

  • PDF

keV SURFACE MODIFICATION AND THIN FILM GROWTH

  • Koh, Seok-Keun;Choi, Won-Kook;Youn, Young-Soo;Song, Seok-Kyun;Cho, Jun-Sik;Kim, Ki-Hwan;Jung, Hyung-Jin
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.S2
    • /
    • pp.95-99
    • /
    • 1995
  • keV ion beam irradiatin for surface modification and thin film growth have been discussed. keV ion beam irradiation in reactive gas environment has been developed for improving wettability of polymer, and for enhancing adhesion to metal film, and adventages of the method have been reviewed. An epitaxial Cu film on Si(100) substrate has been grown by ionized cluster beam and changes of crystallinity and surface roughness have been discussed. Stoichiometric $SnO_2$ films on Si(100) and glass have been grown by a hybrid ion beam Deposition(2 metal ion sources+1 gas ion source), and nonstoichiometric $SnO_2$ films are controlled by various deposition conditions in the HIB. Surface modification for polymer by kev ion irradiation have been developed. Wetting angle of water to PC has been changed from 68 degree to 49 degree with $Ar^+$ irradiation and to 8 degree with $Ar^+$ irradiation and the oxygen environment. Change of surface phenomena in a keV ion beam and characteristics of the grown films are suggested.

  • PDF

A Qualitative Study of Film Creators' Information Behavior Model (영화창작자의 정보활동모형 설계에 관한 질적 연구)

  • Lee, Jung-Yeoun
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.42 no.4
    • /
    • pp.417-439
    • /
    • 2008
  • This study interpreted film-creators' information behavior by reconstructing information behavior in the process of film-planning using human information behavior. Film creators exchange, collect, and analyze information through channels in the information environment so called "the small world." After these processes, they strategically express this information by creating a film. This study concludes that the purpose of film-creating activity and that of everyday life information seeking are intertwined and that co-communication is the most important information channel and information source.

Design and Evaluation of Wireless Sensor Node Application for u-Healthcare (u-헬스케어를 위한 무선센서노드 어플리케이션 구현 및 성능 평가)

  • Lee, Dae-Seok;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.518-521
    • /
    • 2007
  • The functional wireless sensor node for u-healthcare application was developed. The developed sensor node can check the abnormality of ECG in some simple software in ROM of microprocess in the sensor node. The ECG signal is one of very important health signal form human body, and wavelike signal which is sampled as a sampling frequency between 100 and 400 Hz for digitalization, so the wireless data dor ECG signal is some heavy in Zigbee communication. Thus the sensor send the ECG signal to other sensor nodes or base station when it find abnormality in ECG signal is key technology to reduce the traffic between sensor nodes in wireless sensor network for u-healthcare, The sensor node does not need to transmit ECG data all time in wireless sensor network and to server. Using these sensor nodes, the healthcare system can dramatically reduce wireless data packet overload, the power consumption of battery in the sensor nodes and thus increase the reliability of the wireless system.

  • PDF

Immunogenicity and safety of enhanced-inactivated poliovaccine(eIPV) in healthy Korean infants (한국 영아에서 eIPV의 면역원성과 안정성)

  • Kim, Jung Soo;Hong, Young Jin;Kim, Jong Duk;Jang, Young Taek;Kang, Jin Han
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.8
    • /
    • pp.864-869
    • /
    • 2006
  • Purpose : We evaluated the immunogenicity and safety of eIPV(Imovax $Polio^{(R)}$) in a group of healthy Korean infants on a three-dose primary vaccination. Methods : Eighty one healthy infants aged 8-10 weeks were enrolled, and 79(male 42, female 37) completed the study. Three doses of eIPV were injected intramuscularly at 2, 4 and 6 months of age as of primary vaccination. Most subjects received concomitant vaccines such as DTaP and/or Hib at 2, 4, and 6 months of age. Immediate reactions were monitored for 30 minutes after each injection. Local and systemic events were recorded for 72 hours following each immunization by parents/guardians. Poliovirus specific neutralizing antibodies were measured using enzyme immuno-assay (EIA) at prior to and 1 month after the third dose. An antibody titer of 1:8 or higher was considered seroprotective. Geometric mean titers(GMTs) to each poliovirus type antigen were also measured. Results : One month after the third dose of eIPV, all infants(100 percent) were seroprotective. The geometric mean titers(GMTs) were 1,532(95 percent CI : 1,312-1,788) in type 1 and 835(95 percent CI : 684-1,018) in type 2 and 846(95 percent CI : 692-1,035) in type 3. Overall, local reactions were observed in 10 percent of infants and systemic reactions in 26.2 percent of infants. All reactions were observed within 3 days after vaccination and resolved without treatment. Conclusion : eIPV(Imovax $Polio^{(R)}$) is a well-tolerated and highly immunogenic vaccine. It can be administered either alone or simultaneously with other routine vaccines to Korean infants.

Evaluation on the Accuracy of Vaccination Card for National Immunization Program in a 2005 Population-Based Survey in Nonsan, Korea (일개 도농복합시 영유아 예방접종 수첩의 정확도 평가)

  • Lee, Moo-Sik;Kim, Jee-Hee;Kim, Kwang-Hwan;Hong, Jee-Young;Lee, Jin-Yong;Kim, Keon-Yeop
    • Journal of agricultural medicine and community health
    • /
    • v.36 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • The aims of this study were to survey, evaluate the accuracy of personal immunization record of vaccination card, and to establish the applicability of personal immunization record for presuming population based immunization rate and evaluation method. In 2005, a population-based survey of 12-35 months old children was carried out in Nonsan, Korea. We conducted household survey and provider check using questionnaire and checklist to obtain data on immunization status for children. Total 11 vaccinations were checked in vaccination card such as BCG, hepatitis b, polio, chickenpox vaccine. For estimating accuracy of immunization status and dates of immunization, we estimated correspondence rate between data from personal vaccination card and data from medical records and immunization registry data. Accuracy of the child's vaccination card by type of National Immunization Program vaccine in whole medical institutions were from 41.8% to 83.2%. Accuracy for the date of vaccination of vaccination card in National Immunization Programme vaccine were from 55.3% to 89.7%. In spite of this study limitations, this study verified the validity of vaccination record of vaccination card substantially, but suggests more efforts to reassure the validity of vaccination card.

Validation of enzyme immunoassay for the quantitative measurement of human IgG antibodies specific for Haemophilus influenzae Type b capsular polysaccharide (Haemophilus influenzae type b 피막 다당질 특이 인간 IgG 항체의 정량적 측정을 위한 enzyme immunoassay의 타당성 연구)

  • Kim, Kyung Hyo;Lim, Soo Young
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.2
    • /
    • pp.143-150
    • /
    • 2007
  • Purpose : This study was conducted to validate enzyme immunoassay (EIA) for the quantitative measurement of human IgG antibodies specific for Haemophilus influenzae type b (Hib) capsular polysaccharide. Method : We evaluated specificity, repeatability, intermediate precision, accuracy, lower limit of quantification (LLOQ), and stability to validate standardized EIA for the quantitative measurement of human anti-polyribosylribitol phosphate (PRP) IgG antibodies. Results : The results indicated that this EIA showed specificity to HbO-HA antigen and repeatability and intermediate precision were within acceptance criteria (repeatability: $CV{\leq}15%$, intermediate precision: $CV{\leq}20%$). The EIA-derived results from this laboratory were equivalent to those obtained by the standard radioactive antigen binding assay (RABA) for quantitation of anti-PRP antibodies in the 28 sera. Spiking recovery result was within acceptance criteria ($100{\pm}20%$). The precision and accuracy of samples in LLOQ were from -14.7 to -4.7% in nominal values, which were within acceptance criteria (precision: $CV{\leq}25%$, accuracy: ${\pm}25%$). Freeze-thaw stability and short term temperature stability were within ${\pm}20%$ of acceptance criteria. Conclusions : The EIA which is performed at the Center for Vaccine Evaluation and Study Ewha Medical Research Institute, is an appropriate serologic assay which can be used for quantitation of anti-PRP IgG antibodies in human sera.