• Title/Summary/Keyword: Hi-tech

Search Result 233, Processing Time 0.061 seconds

PVT Measurement and Phase Transition Behavior of Dimer Liquid Crystals (이량체액정의 PVT측정과 상전이 거동)

  • 남수용
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.14 no.1
    • /
    • pp.17-29
    • /
    • 1996
  • N-substituted acrylamide hydrogel is reported to have the feature of bing transparent and sensitive enough to response to a temperature stimulus below the temperature of phase transition. Especially at the near of 35 C it becomes shrunk and opaque very quickly. It has also the characteristic of reversing swelling and shrinking. The experiment showed that it is possible to produce a functional gel of super water absorption with the process of free radical polymerizing PVA(polyvinylalcohol) and PAA(polyacrylamide), and crosslinking. The ratio of shrinking and swelling caused by copolymerization rises 10% to 80% at the each temperature of 20 C, 30 C, 40 C, respectively. Phase transition temperature of this gel by copolymerization is50 C while that of ordinary N-substituted acrylamides is between 32~35 C. This temperature reaches the rearing limit of animals and plants so that volumetric transition polymer gel can be ulilized in varying fields such as agriculture/gardening which are water-using field, on-off switch sensing temperature and volumetric variation, processing of liquid wastes and civil engineering works, architecture and electronics. We have no doubt that this material will be the high-functional resin in the hi-tech age of the near future.

  • PDF

Development of Automatic Welding DB System using Panel PC (패널 PC를 이용한 용접 자동화 DB 시스템의 개발)

  • Kim, D.W.;Park, J.H.;Shin, D.R.;Park, H.S.;Jung, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2284-2287
    • /
    • 2004
  • In this paper, an automatic welding DB system using a panel PC is developed. In the developed system, a automatic welding system is remotely controlled to overcome the restriction of operating condition by a portable panel PC, and the DB system such as the operating condition and control data of automatic welding carriage is developed by ATMega128.

  • PDF

Development of Leakage Current Sensing Controller in Consideration of Industrial EMS (산업용 EMS를 고려한 누설전류 센싱 컨트롤러의 개발)

  • Park, Sung-Won;Roh, Inh-Bae;Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.70-71
    • /
    • 2009
  • In recent years, a importance of EMS(Electromagnetic Susceptibility) is increased with the spread of a communication device significantly. The compatibility of EMS is evaluated by conduction and radiation of EMI(Electromagnetic Interference). In this paper, a leakage current sensing controller which is considered of industrial EMS is developed. The developed system is consisted of power module, sensing module of leakage current, processer module, display module and communication module. The developed system is evaluated the compatibility of EMS by conduction and radiation of EMI. In evaluation results, the developed system is compatible to the standard of industrial EMS.

  • PDF

Community Characteristics of Ground Beetles in Four Gotjawal Terrains of Jeju Island, Korea (제주도의 곶자왈에 분포하는 지표성 딱정벌레 군집의 특성)

  • Jeon, Hyung-Sik;Yang, Kyoung-Sik;Lee, Ga-Eun;Kim, Won-Taek
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.3
    • /
    • pp.226-232
    • /
    • 2008
  • Sampling of the ground beetles in four 'gotjawal' terrains of Jeju island was conducted from April to October, 2007, using pit-fall trap. Totally 2,887 individuals of 23 species belonged to 4 families were collected. The species diversity index was the highest at Aeweol gotjawal (AW), while it was the lowest in Hangyeong-Andeog gotjawal (HA). Clustering analysis revealed that the insect communities of four gotzawals were grouped in only one cluster. Jocheon-Hamdeog gotjawal (JH) formed a cluster with Gujwa-Sungsan gotjawal (GS) at the lowest chord distance (0.24). At the higher chord distance of 0.50, AW fused the cluster of JH and GS. HA fused with the rest three terrains, forming a single cluster at the highest chord distance of 0.98.

A Study on Development of Online Wide Area SynchroPhasor and Voltage Stability Monitoring System using Satellite Network (위성망을 이용한 온라인 광역 동기위상 및 전압안정도 감시 시스템 개발에 관한 연구)

  • Kwon, Dae-Yun;Kim, Tae-Jin;Yoon, Sang-Hyun;Jung, Gwang-Gyun;Oh, Gyu-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.273-274
    • /
    • 2008
  • Recently, the most wide-area blackout in North America, Canada and Europe had shown us indirectly the importance of Wide-Area Power System Protection and had influence on the direction of domestic electric power industry. After reorganization of the electric power industry in 2001, market incentives controls the power generation, transmission and distribution rather than stability of power grid, and moreover it produce bad results like inefficient facility management and too much competition. In addition, we can easily predict the massive loss of social and economic when the wide-area outage occurs by north direction load flow which is a pending problems of domestic power system and in a changed industry likes hi-tech manufacture and information technology industries. This paper introduces the development of infra systems for prevent wide-area blackout in situations of the power system operations.

  • PDF

Opposition Based Differential Evolution Algorithm for Capacitor Placement on Radial Distribution System

  • Muthukumar, R.;Thanushkodi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2014
  • Distribution system is a critical link between customer and utility. The control of power loss is the main factor which decides the performance of the distribution system. There are two methods such as (i) distribution system reconfiguration and (ii) inclusion of capacitor banks, used for controlling the real power loss. Considering the improvement in voltage profile with the power loss reduction, later method produces better performance than former method. This paper presents an advanced evolutionary algorithm for capacitor inclusion for loss reduction. The conventional sensitivity analysis is used to find the optimal location for the capacitors. In order to achieve a better approximation for the current candidate solution, Opposition based Differential Evolution (ODE) is introduced. The effectiveness of the proposed technique is validated through 10, 33, 34 and85-bus radial distribution systems.

0.7 inch FED Panel system build-up by using proper sealing process

  • Kwon, Sang-Jik;Hong, Kun-Jo;Cho, Tae-Hee;Lee, Jong-Duk;Oh, Chang-Woo;Kwon, Yong-Bum
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.1
    • /
    • pp.85-89
    • /
    • 1999
  • FDE panel was successfully fabricated through the integration of a 0.7" diagonal Si-based Mo-tip FEA with 25${\times}$25 pixels, Y2O3:Eu or ZnO:Zn phosphor screen, and vacuum sealing through an exhausting glass tube, including a getter. The panel system was driven by an external driver circuit having pulse width modulation(PWM) driving scheme. Before character imaging, it was stabilized through tip aging by slowly increasing a pulse-mode emission current and phosphor aging by a coulombic charging process. After aging, luminescent characteristics such as emission uniformity, charging and arcing phenomena were shown to be improved significantly.

  • PDF

Pretreatment of Highway Rainfall Runoff with a Hydrodynamic Separator (수리동력학적 분리장치에 의한 고속 도로 강우유출수의 전처리 기술)

  • Yu, Jianghua;Yi, Qitao;Kim, Phil-Ju;Lu, Wei Wei;Park, Sung-Soon;Kim, Young-Chul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.885-887
    • /
    • 2009
  • 고속도로 교량이나 성토지역 노면이 제공하는 자연적인 위치에너지(동력)를 활용하여 수리학적인 입자상 오염물질 분리장치를 실험실 조건에서 운전한 결과 운전압력 0.5기압(수두 5.6m) 이상에서 90% 이상의 제거효율을 보였다. $D_{50}$는 약$45{\mu}m$이었는데 입자의 크기가 $45{\mu}m$ 보다 굵은 입자는 거의 대부분 제거되지만 $45{\mu}m$보다 작은 입자의 제거는 쉽지 않음을 시사해주고 있다. 이러한 입자를 제거하기 위한 후속장치가 필요하며 장치의 원활한 운전을 위해서 유지관리문제에 대한 치밀한 검토가 필요하다.

  • PDF