• 제목/요약/키워드: Hexavalent chromium (VI)

검색결과 64건 처리시간 0.019초

Removal of hexavalent chromium Cr (VI) by adsorption in blended lateritic soil

  • Sunil, B.M.;Faziludeen, Saifiya
    • Advances in environmental research
    • /
    • 제4권3호
    • /
    • pp.197-210
    • /
    • 2015
  • Hexavalent chromium [Cr (VI)] adsorption on lateritic soil and lateritic soil blended with black cotton (BC) soil, marine clay and bentonite clay were studied in the laboratory using batch adsorption techniques. In the present investigation the natural laterite soil was blended with 10%, 20% and 30% BC soil, marine clay and bentonite clay separately. The interactions on test soils have been studied with respect to the linear, Freundlich and Langmuir isotherms. The linear isotherm parameter, Freundlich and Langmuir isotherm parameters were determined from the batch adsorption tests. The adsorption of Cr (VI) on natural laterite soil and blended laterite soil was determined using double beam spectrophotometer. The distribution coefficients obtained were 1.251, 1.359 and 2.622 L/kg for lateritic soil blended with 10%, 20% and 30% BC soil; 5.396, 12.973 and 48.641 L/kg for lateritic soil blended with marine clay and 5.093, 8.148 and 12.179 L/kg for lateritic soil blended with bentonite clay respectively. The experimental data fitted well to the Langmuir model as observed from the higher value of correlation coefficient. Soil pH and iron content in soil(s) has greater influence on Cr (VI) adsorption. From the study it is concluded that laterite soil can be blended with clayey soils for removing Cr (VI) by adsorption.

Reduction of Hexavalent Chromium by Escherichia coli ATCC 33456 in Batch and Continuous Cultures

  • Bae, Woo-Chul;Kang, Tae-Gu;Kang, In-Kyong;Won, You-Jung;Jeong, Byeong-Chul
    • Journal of Microbiology
    • /
    • 제38권1호
    • /
    • pp.36-39
    • /
    • 2000
  • Toxic hexavalent chromium, Cr(VI), was reduced to a less toxic trivalent chromium form by E. coli ATCC 33456. The suitable electron donor for Cr(VI) reduction was glucose. E. coli ATCC 33456 was more resistant to metal cations than other reported Cr(VI) reducing microorganisms. Cell growth was inhibited by the presence of Cr(VI) in a liquid medium and Cr(VI) reduction accompanied cell growth. With a hydraulic retention time of 20 h, Cr(VI) reducing efficiency was 100% to 84% when Cr(VI) concentration in the influent was in the range of 10 to 40 mg L$\^$-1/. Specific rate of Cr(VI) reduction was 2.41 mg Cr(VI) g DCW$\^$-1/ h$\^$-1/ when 40 mg L$\^$-1/ of Cr(VI) influent was used. This result suggested the potential application of E. coli ATCC 33456 for the detoxification of Cr(VI) in Cr(VI) contaminated wastewater.

  • PDF

공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도- (Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures)

  • 신용철;이병규;이지태
    • 한국대기환경학회지
    • /
    • 제18권1호
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

Reduction of hexavalent chromium by pseudomonas aeruginosa HP014

  • Oh, Young-Sook;Choi, Sung-Chan
    • Journal of Microbiology
    • /
    • 제35권1호
    • /
    • pp.25-29
    • /
    • 1997
  • Microbial reduction of hexavalent (VI) to trivalent (III) chromium decreases its toxicity by two orders of magnitude. In order to investigate the nature of Cr-reduction, Cr-resistant Pseudomonas aeruginosa HP014 was isolated and tested for its reduction capability. At the concentration of 0.5 mM Cr(VI), cell growth was not inhibited by the presence of Cr(VI) in a liquid medium, and Cr(VI) reduction was accompanied by ell growth. When cell-free extract was tested, the reduction of Cr(VI) showed a saturation kinetics with the maximum specific activity of 0.33 .mu.mol min$\^$-1/ mg$\^$-1/ cell protein, and an apparent K. of 1.73 mM Cr(VI). The activity required either NADH or NADPH as an electron donor. However, NADPH gave 50% as mush activity as sequently the supernatant and pelleted membrane fractions were tested for Cr(VI) reduction activity. The supernatant of the centrifugation showed almost the same Cr(VI) reduction activity as compared with that of the cell-free extract, indicating that the Cr(VI)-reducing activity of P. aeruginosa HP-14 is due to soluble enzyme. Moreover, the activity appeared to be the highest among the known activities, suggesting that the strain might be useful for remediation of Cr(VI)-contaminated sites.

  • PDF

Ion Chromatography/Visible Absorbance Detection을 이용한 Cr(VI) 분석의 정확도 및 정밀도 평가 (Accuracy and Precision of Ion Chromatography/Visible Absorbance Detection for Analyzing Hexavalent Chromium Collected on PVC Filter)

  • 신용철;오세민;백남원
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.223-232
    • /
    • 1997
  • The accuracy and precision of a modified method of NIOSH Method 7600 and EPA method 218.6 was determined for analyzing hexavalent chromium, Cr(VI), collected on PVC filter from workplace air. The method was designed to extract from Cr(VI) on PVC filter with a alkali solution, 2% NaOH/3% $Na_2CO_3$, and to analyze it using ion chromatography/visible absorbance detection(IC/VAD). The results and conclusion are as the following. 1. The peak of Cr(VI) was separated sharply on chromatogram and was linearly related with Cr(VI) concentration in sloution. The correlation coefficient was 0.9999 in a calibration curve. The limit of detection was 0.25 $0.25{\mu}g/sample$. 2. The accuracy(% recovery) was 93.3% in a set of sample($9-50{\mu}g$) stored for a day, and 100.1%($10-60{\mu}g$) in another set of samples stored for 2 hours. It is assumed that the difference in recovery by storage time was due to reduction of Cr(VI) to Cr(III). 3. The precision(coefficient of variation, CV) of the method was 0.015 in spiked samples with Cr(VI) standard solution, and 0.010 in spiked samples with plating solution from a chrome electroplating factory. The overall CV in all types of samples was 0.0013. 4. The Cr(VI) was stable in 2% NaOH/3% $Na_2CO_3$ at least for 10 hours. In conclusion, the IC/VAD method is appropriate for determining low-level Cr(VI) in workplace air containing various interferences.

  • PDF

Effect of Hexavalent Chromium on Egg Laying Capacity, Hatchability of Eggs, Thickness of Egg Shell and Post-Hatching Development of Gallus domesticus

  • Asmatullah, Asmatullah;Asma, A.;Latif, A.;Shakoori, A.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권6호
    • /
    • pp.944-950
    • /
    • 1999
  • Hexavalent chromium (CrVI) was fed to one day old chicks of Gallus domesticus in the form of different concentrations (250 and 500 mg/kg feed) of potassium dichromate mixed with the feed, ad libitum, for 32 weeks. After 20 weeks of feeding, the total body weight was higher in the low dose (260 mg/kg (feed) group and lower in the high dose (500 mg/kg feed) group, as compared with the control chicks. After 32 weeks of feeding, however, the total body weight was significantly decreased in both the treated groups. Egg laying was enhanced. Fertility remained unaffected, whereas hatchability was considerably decreased after CrVI-treatment. The egg shell thickness increased significantly (13%). Cr was deposited in a dose dependent manner in the liver and lungs. Some structural derangements in liver were also noted in treated chicks. The results of this study i.e., rapid ageing, excessive Cr deposition, decreased hatchability and hepatotoxicity indicate toxic effects of CrVI.

도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구 (Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation)

  • 이병규;신용철
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).

Distribution of Airborne Hexavalent Chromium Concentrations in Large Industrial Complexes in Korea

  • Kang, Byung-Wook;Lee, Hak-Sung;Kim, Jong-Ho;Hong, Ji-Hyung;Kim, Rok-Ho;Seo, Young-Kyo;Han, Jin-Seok;Baek, Kyung-Min;Kim, Min-Ji;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권4호
    • /
    • pp.208-216
    • /
    • 2016
  • This paper reports the results of a field evaluation which used sampling and analytical methods to determine the levels of airborne hexavalent chromium Cr(VI) in major industrial complexes in Korea over a seven year period (2007-2013). Cr(VI) concentrations were determined using cellulose filter sampling and ion chromatography analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control (QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of Cr(VI) for the nine industrial complexes in Korea were in the range of 0.09 to $1.40ng/m^3$, which is similar to of the concentrations in other industrial areas around the world. The impacts of Cr(VI) emissions from industrial areas on Cr(VI) concentrations in neighboring-residential areas were considerably low, and the dispersion of Cr(VI) from industrial areas to residential areas was estimated to be 'not-significant'. Cr(VI) levels were not affected by seasonal variation, which suggests that chromium was emitted continuously from the industrial sources throughout the year. The concentration of Cr(VI) measured accounted for 0.7 to 9.4 percent of the total chromium level, which is a low percentage compared to those in other urban areas around the world. This is the first report in an international journal of a field study conducted in Korea to determine the concentration of Cr(VI) in the ambient air of industrial and residential areas.

Characteristics of a Novel Acinetobacter sp. and Its Kinetics in Hexavalent Chromium Bioreduction

  • M., Narayani;K., Vidya Shetty
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권5호
    • /
    • pp.690-698
    • /
    • 2012
  • Cr-B2, a Gram-negative hexavalent chromium [Cr(VI)] reducing bacteria, was isolated from the aerator water of an activated sludge process in the wastewater treatment facility of a dye and pigment based chemical industry. Cr-B2 exhibited a resistance for 1,100 mg/l Cr(VI) and, similarly, resistance against other heavy metal ions such as $Ni^{2+}$ (800 mg/l), $Cu^{2+}$ (600 mg/l), $Pb^{2+}$ (1,100 mg/l), $Cd^{2+}$ (350 mg/l), $ZN^{2+}$ (700 mg/l), and $Fe^{3+}$ (1,000 mg/l), and against selected antibiotics. Cr-B2 was observed to efficiently reduce 200 mg/l Cr(VI) completely in both nutrient and LB media, and could convert Cr(VI) to Cr(III) aerobically. Cr(VI) reduction kinetics followed allosteric enzyme kinetics. The $K_m$ values were found to be 43.11 mg/l for nutrient media and 38.05 mg/l for LB media. $V_{max}$ values of 13.17 mg/l/h and 12.53 mg/l/h were obtained for nutrient media and LB media, respectively, and the cooperativity coefficients (n) were found to be 8.47 and 3.49, respectively, indicating positive cooperativity in both cases. SEM analysis showed the formation of wrinkles and depressions in the cells when exposed to 800 mg/l Cr(VI) concentration. The organism was seen to exhibit pleomorphic behavior. Cr-B2 was identified on the basis of morphological, biochemical, and partial 16S rRNA gene sequencing chracterizations and found to be Acinetobacter sp.

모 조선업체 아크 용접 작업자의 공기중 6가 크롬 및 니켈 노출에 관한 연구 (Welder's Exposure to Airborne Hexavalent Chromium and Nickel during Arc Welding in a Shipyard)

  • 신용철;이광용;이나루;오세민;강성규;문영한;이기라
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.209-223
    • /
    • 1998
  • The aim of this study was to evaluate welders' exposure to hexavalent chromium (Cr(VI)) and nickel (Ni) during welding operations in a Korean shipyard. The airborne Cr(VI) and Ni concentrations were measured during metal inert gas (MIG) welding on mild and stainless steel, and manual metal arc (MMA) welding on mild steel. The geometric mean (GM) of Cr(VI) concentrations inside the welding helmet during MIG welding on mild steel were $0.0018mg/m^3$ inside a ship section, and $0.0015-0.0026mg/m^3$ at the welding shops. All of the personal breathing zone air samples were below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$) of $0.01mg/m^3$. Conversely, eighty-eight percent(21 of 24) of the personal breathing zone air samples exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit of $0.001mg/m^3$. Ni was not detected on 20 of 23 air samples collected during MIG welding on mild steel. The three Ni samples above the limit of detection ranged from 0.015 to $0.044mg/m^3$. The GM of Cr(VI) concentrations during MMA welding on mild steel were $0.0013mg/m^3$, but Ni was not detected in the air samples during this operation. It is assumed that the airborne Cr(VI) and Ni during mild steel welding were derived from the base metals which contained about 0.03% Cr and 0.03% Ni. The GM of airborne total Cr, Cr(VI) and Ni concentrations during MIG welding on stainless steel were 4.02, 0.13 and $0.86mg/m^3$, respectively, and the levels of Cr(VI) and Ni were above the ACGIH-$TLV^{(R)}$. Cr(VI) comprised about 35.5% of the total chromium(Cr) from MIG welding on mild steel, and about 8.4% of total Cr from MIG welding on stainless steel. The ratios of Cr(VI) to total Cr were significantly different among welding shops. It was concluded that welders were exposed to high levels of Cr(VI) and Ni during welding on stainless steel, and were exposed to low levels of Cr(VI) even during welding on mild steel.

  • PDF