• Title/Summary/Keyword: Hexavalent chromium

Search Result 165, Processing Time 0.025 seconds

Immobilization Characteristics of Hexavalent Chromium Contaminated Soils Treated with Phosphate and Chromium Reducing Agent (크롬환원제와 인산염으로 처리된 6가 크롬 오염토양의 고정화)

  • Lee, Eui-Sang
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Hexavalent chromium-contaminated soils are encounted at many unregulated discharge and improper handling of wastes from electroplating, leather tanning, steelmaking, corrosion control, and wood preservation industries. Contamination of hexavalent chromium in the soil is a major concern because of its toxicity and threat to human life and environment. Current technologies for hexavalent chromium-contaminated soil remediation are usually costly and/or cannot permanently prohibit the toxic element from entering into the biosphere. Thus, as an alternative technique, immobilization is seen as a cost-effective and promising remediation technology that may reduce the leachable potential of hexavalent chromium. The purpose of this paper is to develope an immobilization technique for the formation of the geochemically stabilized hexavalent chromium-contaminated soil from the reactions of labile soil hexavalent chromium forms with the added soluble phosphate and chromium reducing agent. From the liquid phase experiment, reaction order of chromium reducing agent, soluble phosphate, alkali solution shows the best removal efficiency of 95%. In addition, actual soil phase experiment demonstrates up to 97.9% removal efficiency with 1:1 molar ratio of chromium reducing agent and soluble phosphate. These results provide evidence for the potential use of soluble phosphate and chromium reducing agent for the hexavalent chromium-contaminated soil remediation.

Study on the Quantitative Analysis Methods of Hexavalent Chromium in Flexography Inks and Organic Pigments - Alkaline digestion and Colorimetric Measurement - (플렉소 잉크 및 유기안료의 6가 크롬 함량 측정 방법에 관한 연구 - 알칼리 분해 및 비색측정법 -)

  • Kim, Jin-Woo;Youn, Hye-Jung;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.4
    • /
    • pp.33-42
    • /
    • 2009
  • This study was performed to evaluate the hexavalent chromium content in flexography inks and organic pigments used as colorants for the ink. The digestion of sample was carried out under alkaline condition, and the content of soluble hexavalent chromium extracted from samples was determined by UV-visible colorimetric analysis method after alkaline digestion. Duplicate sampling system to obtain two digested samples, was applied in this study. To determine the hexavalent chromium content in the flexography ink and organic pigment colorimeteric analysis was employed. Because the organic pigment is the main ingredient of flexography ink it is important to remove the errors associated with the colorant of the ink in colorimetric determination. The duplicate sampling system allowed us to correct the errors associated with the colorimeteric measurement. The additional filtration was found an essential step to exclude colorimeteric error derived from the various precipitates. The soluble hexavalent chromium content in flexography inks was generally less than 5 ppm. Yellow, violet and some magenta colors showed higher soluble hexavalent chromium contents. The content of hexavalent chromium in organic pigments was greater than flexography inks, and yellow, violet and some magenta pigments contained greater amount of hexavalent chromium, which indicated that the hexavalent chromium in inks derives from the colorants. The soluble hexavalent chromium content in linerboards were below 1 ppm, and no hexavalent chromium was detected in UKP. Results suggested that flexography ink is the main factor to cause hexavalent chromium in linerboard and organic pigments.

Evaluation of Total, Water-soluble and Hexavalent Chromium Contents in Construction Materials(Concretes, Cements)

  • Choi, In-Ja;Yoon, Chung-Sik;Choi, Sang-Jun
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.6
    • /
    • pp.497-501
    • /
    • 2007
  • The objective of the study is to determine the contents of total chromium, water-soluble chromium and hexavalent chromium in cements and concretes specimens taken from manufacturing or construction sites. Chromate is an allergen that is widespread in the environment and is richly contained in cements. Metals were extracted with microwave oven and analyzed by atomic absorption spectrometer. Hexavalent chromium was analysed by ion chromatography. The concentrations of total chromium, water-soluble chromium and hexavalent chromium in cements were $36.02{\sim}108.01,\;15.95{\sim}89.01\;and\;26.77{\sim}89.61\;mg/kg$, respectively. The concentrations of hexavalent chromium in cements were higher than 2 mg/kg, a maximum value recommended in Northern European Countries. The concentrations of total chromium, water-soluble chromium and hexavalent chromium in concretes were $17.44{\sim}76.25,\;0.98{\sim}17.71\;and\;ND{\sim}24.13\;mg/kg$, respectively. Especially Hexavalent chromium was detected only from concrete specimens from construction sites. It is oxidized or reduced status by environmental condition or surrounding materials.

The Removal of Hexavalent Chromium from Aqueous Solutions Using Modified Holly Sawdust: Equilibrium and Kinetics Studies

  • Siboni, M. Shirzad;Samarghandi, M.R.;Azizian, S.;Kim, W.G.;Lee, S.M.
    • Environmental Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • The removal of hexavalent chromium from aqueous solutions onto modified holly sawdust was studied at varying initial hexavalent chromium concentrations, adsorbent doses, pHs and contact times. The removal of hexavalent chromium from aqueous solutions increased with increasing adsorbent dosage and contact time. The percentage of hexavalent chromium removed from the aqueous solutions decreased with increasing hexavalent chromium concentration and pH of the solution. The kinetics of the adsorption of hexavalent chromium onto modified holly sawdust was analyzed using pseudo first-order and pseudo second-order models. The pseudo second-order model described the kinetics of adsorption of hexavalent chromium. The Langmuir and Freundlich isotherm models were used for modeling of the adsorption equilibrium data. The Langmuir isotherm model well described the equilibrium data for the removal of hexavalent chromium by modified holly sawdust. The obtained maximum adsorption capacity was 18.86 mg/g at pH 7. The results showed that modified holly sawdust can be used as a low cost adsorbent for the treatment of aqueous solutions containing chromium.

Effects of Hexavalent Chromium on Mitochondrial Respiration of Rat Kidney and Function of Low-Molecular-Weight, Chromium-Binding Substances ($Cr^{6+}$가 흰쥐 신장세포내 미토콘드리아의 호흡에 미치는 영향과 저분자 크롬결합물질의 작용)

  • Kang, Soo-Gil;Boo, Moon-Jong;Choe, Rim-Soon
    • Applied Microscopy
    • /
    • v.19 no.2
    • /
    • pp.43-58
    • /
    • 1989
  • To investigate the effects of hexavalent chromium on mitochondrial respiration of rat kidney, various hexavalent chromium concentrations were treated, then respiration and electron transfer enzyme activities were measured. Ultrastructural changes at state IV respiration of mitochondria were also observed. Then, to investigate protective role against hexavalent chromium in the body, low-molecular-weight, chromium-binding substances (LMCr) were purified from livers of rabbits 2hr after intravenously administrated with sodium dichromate at a dose of 74mg per kg body weight. And then, respiration rates of mitochondria treated with LMCr, hexavalent chromium containing 0.7mM chromium were measured. Hexavalent chromium decreased state IV respiration rates and electron transfer enzyme activities of mitochondria, and increased labile membrane and swelling. And partial inhibitions of condensed to orthodox conformational change were observed. Respiration rates of mitochondria treated with LMCr containing 0.7mM chromium did not differ from that of the non-treated mitochondria. But respiration rates of 0.7mM hexavalent chromium-treated mitochondria decreased by 42%, compared to non-treated mitochondria. These results suggest that LMCr may play an important role in detoxification of toxic hexavalent chromium.

  • PDF

Cytoprotective Effect of Phenolic Compounds Against Hexavalent Chromium-Induced Cytotoxicity (페놀 화합물의 Hexavalent Chromium독성에 대한 세포 보호효과)

  • Han, Du-Seok;Kang, Jeong-Il;Baek, Seung-Hwa
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.2
    • /
    • pp.1-18
    • /
    • 2009
  • Objectives : In order to evaluate the cytotoxicity of hexavalent chromium, the cytoprotective effect of phenolic compounds against hexavalent chromium-induced cytotoxicity, cell viability, cell adhesion ability, lactate dehydrogenase(LDH) activity, and morphological changes of cells were examined. Methods : We measured the cytotoxicity of hexavalent chromium with 3-[4,5-dimethyl-thiazol-2-yl]-2,5-diphenyltetrazolium bromide(MTT), 2,3-bis-[2-methoxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-caboxanilide (XTT), LDH and DPPH methods. Results : The cytotoxicity of hexavalent chromium($IC_{50}$, $44.0-51.0{\mu}M$) was high according to the toxic criteria. Cytoprotective effect of phenolic compounds against $IC_{50}$ value of hexavalent chromium in cell morphology increased in a concentration-dependent manner. Conclusions : These results suggest that 3,4,5-trihydroxybenzoic acid may be used as a cytoprotective agent against chromium(IV)-mediated cytotoxicity.

  • PDF

Leaching Properties of Water-Soluble Hexavalent Chromium by Manufacturing Condition of Cement Clinker (클링커 제조 조건에 따른 수용성 6가 크롬 용출 특성)

  • Lee, Jong-Kyu;Chu, Yong-Sik;Song, Hun
    • Korean Journal of Materials Research
    • /
    • v.21 no.12
    • /
    • pp.679-684
    • /
    • 2011
  • One of the trace constituents included in cement clinker, chromium, has become prominent and highly noticed lately as a social issue both inside and outside of this country because it affects the human body negatively. The purpose of the present study was to investigate leaching properties of water-soluble hexavalent chromium by different manufacturing conditions of cement clinker. Raw materials were prepared to add different $SiO_2$, $Al_2O_3$ and $Fe_2O_3$ sources. After the raw materials, such as limestone, sand and clay, iron ore was pulverized and mixed, and the raw meal was burnt at $1450^{\circ}C$ in a furnace with an oxidizing atmosphere. Leaching of soluble hexavalent chromium showed a tendency to decrease with an increasing LSF and IM. However, leaching of soluble hexavalent chromium increased with an increasing S.M. Alkali contents of iron source minerals is closely related to the leaching properties of soluble hexavalent chromium. Green sludge has the highest content of alkali added; leaching of water-soluble hexavalent chromium was mostly high. In order to reduce the water-soluble hexavalent chromium in cement, reducing the alkali content in raw materials is important.

Content Variation of Total Chromium and Hexavalent Chromium in Flux Cored Arc Welding (플럭스 코어드 아크 용접 중 발생하는 총 크롬 및 6가 크롬의 함량 변화)

  • Yoon, Chung Sik;Paik, Nam Won;Kim, Jeong Han;Park, Dong Uk;Ha, Kwon Chul;Cho, Sang Jun;Kim, Shin Bum;Chae, Hyun Byung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.32-44
    • /
    • 2000
  • The practice of welding stainless steel is known to produce various valance states of chromium. $CO_2$ flux cored arc welding on stainless was performed in fume collection chamber. Content of total chromium and hexavalent chromium in fumes, content of hexavalent chromium in total chromium, solubility of hexavalent chromium were investigated. Content of total chromium in fumes increases from 2~3% to 7~9% as a function of input energy, but hexavalent chromium, less than 1.2% in fumes, is not related to input energy. Hexavalent chromium in fumes exists as solubles up to 90%. Content of total chromium in flux cored arc welding fumes and solubility of hexavalent chromium are similar to shielded metal arc welding fumes, but content of hexavalent chromium is similar to metal inert gas welding fumes. These characteristics are relevant to flux of wires and $CO_2$ shielding gas.

  • PDF

Chromium in Erythrocytes as a Biological Marker of Worker Exposed to Hexavalent Chromium (적혈구중 크롬농도를 이용한 6가크롬 노출의 생물학적 지표)

  • Yoon, Ui-Seoung;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.223-234
    • /
    • 2000
  • Objective - To evaluate the usefulness of chromium in erythrocytes as a biological marker of exposure to hexavalent chromium in chromate producers and chrome platers Methods - Blood and urine samples were ramdomly obtained from chromate producers (n=34) and chrome platers (n=35), and non-exposed workers (n=75), chromium level in erythrocytes and plasma, and urine were measured. Different chromium exposure workers were assessed through measurements of airborne hexavalent chromium concentrations using a personal air sampler. Linear associations between variables were evaluated with correlation analysis. Results - The chromate producers had mean chromium levels in erythrocytes five fold as higher than the chrome platers, and fifteen fold higher than non-exposed group. Among the chromium exposed workers, airborne hexavalent chromium was positively and strongly correlated with in erythrocytes (r=0.689, p<0.01), and erythrocytes chromium was inversely correlated with hematocrit (r=-0.441, p<0.01), hemoglobin (r=-0.465, p<0.01) and the number of red blood cells (r=-0.28, p<0.05). Conclusions - In conclusion, this study suggests that chromium in erythrocytes is a good indicator of the chromium body burden caused by exposure to hexavalent chromium.

  • PDF

Reduction of Hexavalent Chromium on PVC Filters (혜산산업보건학술상 수상논문 - PVC 여과지에 채취된 6가 크롬의 환원)

  • Sin, Yong-Cheol
    • 월간산업보건
    • /
    • s.356
    • /
    • pp.16-25
    • /
    • 2017
  • Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidationreduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 ; 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 ; 89.9) at 1 hour and 81.0% (78.3 ; 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 ; 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.

  • PDF