• Title/Summary/Keyword: Heterocyclic amines

Search Result 46, Processing Time 0.029 seconds

The Safety of Carcinogenic Heterocyclic Aromatic Amines from the Cooked Foods (식품의 조리.가공중 생성되는 발암성 이환방향족아민의 안전성)

  • 전향숙;김주연
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.4
    • /
    • pp.386-396
    • /
    • 1999
  • Commonly eaten fish, meat and other protein-containing foods show some level of mutagenic activity following normal cooking such as broiling, frying, grilling, roasting etc. The main food mutagens found in cooked products are“heterocyclic aromatic amines”. Several of them have been shown to be carcinogenic in rodent and suggested to be relevant for human cancer etiology. This review summarizes the chemistry, formation, occurrence and toxicity of food-borne heterocyclic aromatic amines. Factors that influence the formation of them are also discussed with special emphasis on dietary factors. From a health safety point of view, it is desirable to estimate the intake of heterocyclic amines via foods, and reduce or prevent the formation of food mutagens.

  • PDF

An analytical method of heterocyclic amines by LC/MS (LC/MS를 이용한 heterocyclic amines의 분석법)

  • Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.115-123
    • /
    • 2007
  • The heterocyclic amines (HAs) are a family of mutagenic/carcinogenic chemicals formed from the cooking of muscle meats such as beef, meat, fowl, and fish. A major draw back in the analysis of HAs from foods is their very low level of concentration (ng/g) and a number of matrix interferences in samples. Solid-phase extraction (SPE) is one of the procedures widely used for the extraction and purification of HAs in food samples. In this study, several SPE procedures of HAs determination were performed. Recoveries of the HAs were obtained from comparing a matrix such as a standard methanolic solution and pre-cooked meat extracts. Recovery values were ranging between 25.3 and 93.0 % at a concentration of 25.0 ng/g. HAs were determined with high sensitivity by micro-HPLC (${\mu}$-HPLC) analysis with electrospray ionization mass spectrometry (ESI-MS). Another developed method, which is freezing filtration method, shows better extraction recoveries and good precisions. The established method will be applicable to monitoring of heterocyclic amines from the cooked meat.

Analysis of Heterocyclic Amines in Mainstream Cigarette Smoke using by LC-MS/MS (LC-MS/MS를 이용한 담배 연기 중 Heterocyclic Amines의 분석)

  • Kim, Ick-Joong;Jang, Gi-Chul;Ji, Sang-Un;Min, Hye-Jeong;Kim, Hyo-Keun;Hwang, Geon-Jung
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.30 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • This study was carried out to determine the analytical methods for heterocyclic amines(HAs) of the tobacco smoke by LC/MS/MS. HAs have been found in pyrolysate of protein and cooked food including protein, were known the Sugimura compound. HAs content of the smoke were known to exist very low ppb level. Especially, some of HAs are mutagenic and carcinogenic compounds. In according to IARC, the toxicity of N-heterocyclic amines classified IARC class 2A or 2B group. Precursors of these compounds are glutamic acid, protein and free amino acids including tryptophan, therefore, the precursors have been proved in cooked food continuously. This study was investigate multiple analysis methods for HAs and HAs contents of some commercial products. In this study, we used the linear type smoking machine for HAs analysis. At the ISO conditions, mainstream smoke was collected on cambridge filter pad, and then cambridge filter pad was extracted by 0.1% acetic acid. The extracted solution were passed cation exchange SPE cartridge to remove matrix, samples were analyzed using LC/MS/MS on MRM mode. From the result that optimized this methods, the correlation coefficient(R) of the individual compounds were good linearity over 0.999, recovery rate over 96% and the limit of detection were good values between 0.06 to 0.37 ng/mL, In addition, HAs content of some commercial products were in range of 0.02 to 43.8 ng/cig.

INHIBITION OF THE FORMATION AND ACTION OF HETEROCYCLIC AROMATIC AMINES

  • Weisburger, John H.
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2001.10a
    • /
    • pp.45-45
    • /
    • 2001
  • Heterocyclic aromatic amines (HCAs) are established genotoxic human cancer risks, that display their activity also in a number of animal models and in vitro. They are formed during the trying or broiling of creatinine-containing foods, mainly fish or meat. We established that mixing soy protein with ground meat blocks the formation of HCAs. we also observed that coating the surface of meat with polyphenols green or from black tea gives a dose - related reduction of the formation of HCAs.(omitted)

  • PDF

Analysis of Heterocyclic Amines in Human Urine Using Multiple Solid-Phase Extraction by Liquid Chromatography/Mass Spectrometry

  • Cha, Hyun-Jeong;Kim, Nam-Hee;Jeong, Eun-Kyung;Na, Yun-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2322-2328
    • /
    • 2010
  • A multiple solid-phase extraction (SPE) method was used with liquid chromatography, coupled with mass spectrometry (LC/MS), for the analysis of heterocyclic amines (HCAs) in human urine. Separation efficiencies based on the pH of the mobile phase and the types of columns were compared. An amide column showed better baseline separation and narrower HCA peak widths at pH 5.0 for the mobile phase than a $C_8$ column. Each SPE step, HLB, MCX, and HybridSPE, was optimized by controlling the pH conditions. The combined method with the three SPEs effectively removed interfering species that cause ion-suppression during HCA detection. Validation of the method, performed with SIM and SRM detection, showed correlation coefficients above 0.991 in the range 0.3 - 16.7 ng/mL. Recovery rates were 45.4 - 97.3% on the $C_8$ column and 71.8 - 101.4% on the amide column, and method detection limits were 0.11 - 0.65 ng/mL on the $C_8$ column and 0.12 - 0.48 ng/mL on the amide column. This method using multiple SPEs offers significant benefits for high-throughput determination of HCAs in urine.

Heterocyclic Amines Removal by Binding Ability of Lactic Acid Bacteria Isolated from Soybean Paste (된장에서 분리된 유산균의 결합력에 의한 Heterocyclic Amines 제거)

  • Lim, Sung-Mee
    • Korean Journal of Microbiology
    • /
    • v.50 no.1
    • /
    • pp.73-83
    • /
    • 2014
  • The objective of the this study was to investigate the binding capacity and removal ability of lactic acid bacterial strains obtained from Korean soybean paste for mutagenic heterocyclic amines (HCAs) formed during cooking of protein-rich food at high temperature. Among 19 strains identified by carbohydrate fermentation and 16S rRNA sequencing, the live cell or cell-free culture supernatant of Lactobacillus acidophilus D11, Enterococcus faecium D12, Pediococcus acidilactici D19, L. acidophilus D38, Lactobacillus sakei D44, Enterococcus faecalis D66, and Lactobacillus plantarum D70 inhibited the mutagenesis caused by either 3-amino-1,4-dimethyl-5H-pyrido[4,3-b] indole (Trp-P-1) or 3-amino-1-methyl-5H-pyrido[4,3-b] indole (Trp-P-2) in Salmonella typhimurium TA98 and TA100. The bacterial cells of the isolated strains showed greater binding activity than the pure cell wall, exopolysaccharide, and pepetidoglycan. The carbohydrate moieties of the cell wall or protein molecules on the cell surface have a significant role in binding Trp-P-1 and Trp-P-2, since protease, heating, sodium metaperiodate, or acidic pH treatments significantly (P<0.05) reduced the binding efficacy of the tested bacteria. Addition of metal ions or sodium dodecyl sulfate decreased the binding ability of E. faecium D12, L. acidophilus D38, and E. faecalis D66. Therefore, the binding mechanisms of these strains may consist of ion-exchange and hydrophobic bonds. Especially, the high mutagen binding by L. acidophilus D38 and L. plantarum D70 may reduce the accumulation or absorption of Trp-P-1 and Trp-P-2 in the small intestine via increased excretion of a mutagen-bacteria complex.

Comparison of Different Solid-Phase Extraction Methods for the Analysis of Heterocyclic Amines from Pan-Fried Pork Meat (가열 조리된 돼지고기의 Heterocyclic Amines 분석을 위한 Solid-phase 추출 방법의 비교)

  • Lee, Jae-Hwan;Back, Yu-Mi;Lee, Kwang-Geun;Shin, Han-Seung
    • Food Science of Animal Resources
    • /
    • v.28 no.5
    • /
    • pp.637-644
    • /
    • 2008
  • Four different extraction and purification methods were evaluated to determine the heterocyclic amines (HCAs) in fried pork patties. Pork patties were cooked in the teflon-coated electric frying pan at $230^{\circ}C$ for 8 min per side. HCAs in the fried pork patties were extracted and purified using four different solid-phase extraction (SPE) methods and quantitated by LC-MS (API-ESI). Recovery of four different extraction and purification methods was evaluated by comparing the HCAs amounts quantified by the standard addition method. Validation of extraction and purification methods for fried pork patties was determined to establish accurate sample preparation. The recoveries of HCAs from different SPE methods were calculated. The recovery yields were 15.7-68.7% (Polar amine group) and 25.0-74.7% (less-polar amine group) in method A. Method D provided recovery yields ranging from 14.1% to 68.7% in polar amine groups and from 3.0% to 72.3% in less-polar amine groups, respectively. Modified procedures of Method A and D were the most suitable extraction and purification method for HCAs analysis from fried pork patties.

Use of Transgenic and Mutant Animal Models in the Study of Heterocyclic Amine-induced Mutagenesis and Carcinogenesis

  • Dashwood, Roderick H.
    • BMB Reports
    • /
    • v.36 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • Heterocyclic amines (HCAs) are potent mutagens generated during the cooking of meat and fish, and several of these compounds produce tumors in conventional experimental animals. During the past 5 years or so, HCAs have been tested in a number of novel in vivo murine models, including the following: lacZ, lacI, cII, c-myc/lacZ, rpsL, and $gpt{\Delta}$ transgenics, $XPA^{-/-}$, $XPC^{-/-}$, $Msh2^{+/-}$, $Msh2^{-/-}$ and $p53^{+/-}$ knock-outs, Apc mutant mice ($Apc^{{\Delta}716}$, $Apc^{1638N}$, $Apc^{min}$), and $A33^{{\Delta}N{\beta}-cat}$ knock-in mice. Several of these models have provided insights into the mutation spectra induced in vivo by HCAs in target and non-target organs for tumorigenesis, as well as demonstrating enhanced susceptibility to HCA-induced tumors and preneoplastic lesions. This review describes several of the more recent reports in which novel animal models were used to examine HCA-induced mutagenesis and carcinogenesis in vivo, including a number of studies which assessed the inhibitory activities of chemopreventive agents such as 1,2-dithiole-3-thione, conjugated linoleic acids, tea, curcumin, chlorophyllin-chitosan, and sulindac.

Inhibitory Effect of Nelumbo nucifera Leaf Extracts on the Formation of Heterocyclic Amines and Mutagenicity during Cooking Beef Steak (쇠고기 스테이크 조리 시 백련 잎 추출물에 의한 Heterocyclic Amine류의 생성 및 돌연변이원성 억제 효과)

  • Moon, Seung-Eun;Sung, Ji-Hoon;Shin, Han-Seung
    • Food Science of Animal Resources
    • /
    • v.31 no.4
    • /
    • pp.563-569
    • /
    • 2011
  • Heterocyclic amines (HCAs) are food mutagens and carcinogens that are found in cooked fish, meat, and protein-rich foods. This study examined the inhibitory effect of marinades containing a Nelumbo nucifera leaf fraction on HCA formation in cooked beef steak. As a result of the Ames assay, cooked beef marinated with the N. nucifera leaf butanol fraction (2.0 g) cooked at $190^{\circ}C$ showed a 61.5% reduction in overall mutagenicity. However, these data revealed no significant difference in mutagenicity in the ethanol, ethyl acetate, or water fractions. Formation of MeIQx (2-amino-3,8 dimethylimidazo[4,5-f]-quinoxalin) and PhIP (2-amino-1-methyl-6-phenylimidazo[4,5-b]-pyridine) was inhibited 60.7-63.5%. Cooked beef marinated with the water fraction of the N. nucifera leaf significantly (p<0.05) reduced the formation of MeIQx, PhIP, and DiMeIQx (2-amino-3,4,8 trimethylimidazo[4,5-f]-quinoxaline) by 65.3, 67.6, and 73.9%, respectively. These results show that marinades containing the N. nucifera leaf fraction could be an alternative method for reducing HCA formation in cooked beef steak.