• 제목/요약/키워드: Hermetic

검색결과 90건 처리시간 0.023초

대체냉매(HFC134a, HC600a)용 밀폐형 왕복동 압축기의 성능해석에 관한 연구 (Performance analysis of a hermetic reciprocating compressor using the alternative refrigerants, HFC134a and HC600a)

  • 김정우
    • 대한기계학회논문집B
    • /
    • 제22권7호
    • /
    • pp.966-979
    • /
    • 1998
  • Thermodynamic and dynamic analysis has been conducted to investigate performance variations induced by substitution of alternative refrigerants, HFC134a or HC600a for CFC12 in hermetic reciprocating compressors. For the thermodynamic analysis, mass and energy conservation laws are applied to the cylinder volume and Helmholtz resonator modeling method is adopted to describe gas pulsations at suction and discharge system. The modeling of the dynamics of the compressor mechanism has been performed with lumped mass method to analyse the bearing loads and friction losses at each bearing. To verify the correctness of this analysis, results of the performance simulation have been compared to those of calorimetric measurrements of compressor operating with CFC12. Analysis of the various losses, noise and reliability as well as performance has been conducted to present the design guideline for the compressor development with alternative refrigerants. It is found that compressors with alternative refrigerants, HFC 134a or HC600a give better COPs than those with CFC12 under the same operating conditions and especially, compressors with HC600a show better reliability and noise characteristics also.

소형 냉장고용 왕복동식 압축기의 열전달에 관한 수치해석 연구 (A Numerical Study on Heat Transfer in a Reciprocating Compressor for a Domestic Refrigerator)

  • 심윤희;윤영;박윤철
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.377-385
    • /
    • 2005
  • An analytical model was developed using the lumped mass parameter method to estimate temperature distribution of metal parts and refrigerant of the hermetic reciprocating compressor, All of the lumped mass has been equated with the first law of thermodynamics. In the delivered equation, correlations of heat transfer coefficient in the heat transfer equation were taken from open literature. The equations are solved by Gauss-Jordan method simultaneously. To verify the developed numerical program, an experiment was conducted with a domestic refrigerator. The compressor which had been installed at the bottom of the experimental refrigerator was modified to measure internal temperature. Model verification test was conducted at $30^{\circ}C$ outdoor temperature with variation of compressor cooling conditions. As a result, there is a good consistency between calculated temperature and measured one.

압축기 밸브의 동적 특성에 대한 연구 (A Study on Dynamic Characteristics of Reed Valve in Hermetic Compressor)

  • 조성욱;박성근;김형석;임종윤
    • 소음진동
    • /
    • 제3권2호
    • /
    • pp.163-167
    • /
    • 1993
  • Suction and discharge valves of special type refrigerant compressor are designed by finite element method for effective valve design development procedure. It is well known that valve dynamic characteristics, for example, the natural frequencies and vibration modes, are necessary for the computer simulation of compressor valve dynamics, the analysis of flow patterns, noise, impact stresses and their propagation phenomena. This paper has analysed the natural frequencies and vibration modes for the first three orders under the given special boundary conditions and the experiments are conducted by laser holography. And also stress distribution is analysed and experiment by strain gage is followed.

  • PDF

비선형 강성을 고려한 밸브 모델의 진동 해석 (Vibration Analysis of a Valve Model with Nonlinear Stiffness)

  • 이수일;주재만;김태식;박윤서
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.143-147
    • /
    • 1998
  • In this study, nonlinear stiffness characteristics of a discharge valve in a small hermetic compressor was considered. It was approximated, with piecewise-linearity, and cubic or quintic nonlinearity by the static load-displacement experimental results. Based on the fluid-structure interaction effects and mass flow rate, the derived 1-DOF equation of motion for the valve model was analyzed. Finally, the dynamic response of the discharge valve was studied with parameters such as the ratio of the running frequency of the compressor to the linear natural frequency of the valve.

  • PDF

냉동공조용 밀폐형 압축기의 대체냉매와 냉동기유 (Alternative Refrigerant and Oil for Hermetic Refrigerant Compressors)

  • 강태욱
    • 기술사
    • /
    • 제34권2호
    • /
    • pp.23-27
    • /
    • 2001
  • Until 1996, CFC refrigerants haven't been used because it destroyed ozone that affecting In ecosystem. And HCFC will prohibit until 2020. In Europe, they attempt to move up its fulfillment. Until now the change have completed CFC into HFC134a and is considerated HCFC into HFC410A and HFC407C. But HFC41 OA has high condenser temperature and HFC407C is non-azeotropic refrigerant mixture and gliding temperature phenomenon. New refrigerant ell POE, PVE, PAG was also developed.

  • PDF

3중 접합 공정에 의한 MEMS 공진기의 웨이퍼레벨 진공 패키징 (Wafer-level Vacuum Packaging of a MEMS Resonator using the Three-layer Bonding Technique)

  • 양충모;김희연;박종철;나예은;김태현;노길선;심갑섭;김기훈
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.354-359
    • /
    • 2020
  • The high vacuum hermetic sealing technique ensures excellent performance of MEMS resonators. For the high vacuum hermetic sealing, the customization of anodic bonding equipment was conducted for the glass/Si/glass triple-stack anodic bonding process. Figure 1 presents the schematic of the MEMS resonator with triple-stack high-vacuum anodic bonding. The anodic bonding process for vacuum sealing was performed with the chamber pressure lower than 5 × 10-6 mbar, the piston pressure of 5 kN, and the applied voltage was 1 kV. The process temperature during anodic bonding was 400 ℃. To maintain the vacuum condition of the glass cavity, a getter material, such as a titanium thin film, was deposited. The getter materials was active at the 400 ℃ during the anodic bonding process. To read out the electrical signals from the Si resonator, a vertical feed-through was applied by using through glass via (TGV) which is formed by sandblasting technique of cap glass wafer. The aluminum electrodes was conformally deposited on the via-hole structure of cap glass. The TGV process provides reliable electrical interconnection between Si resonator and aluminum electrodes on the cap glass without leakage or electrical disconnection through the TGV. The fabricated MEMS resonator with proposed vacuum packaging using three-layer anodic bonding process has resonance frequency and quality factor of about 16 kHz and more than 40,000, respectively.

Stray Load Loss Analysis of Canned Induction Motor for Hermetic Compressor

  • Yamazaki Katsumi;Haruishi Yoshihisa
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.224-228
    • /
    • 2005
  • In this paper, we investigate the main components of stray load loss of induction motors for ammonia compressors. The variations of the losses at each part of the motor due to load are calculated by the combined 3-D-2D finite element method formulated by the mixed moving coordinate systems. The stray load loss is calculated from these results due the definition of IEEE standard-112. It is clarified that the core loss and the eddy current loss of the can increase due to load, which can be considered as the main part of the stray load loss.

적정기술 관점에서 보는 근관 충전 (Root Canal Obturation from the Viewpoint of Appropriate Technology)

  • 김선일
    • 대한치과의사협회지
    • /
    • 제56권10호
    • /
    • pp.567-571
    • /
    • 2018
  • Obturation is a important procedure of root canal treatment. Canal filling should be both provide a hermetic seal for the root canal system and eliminate leakage channel from the oral cavity. Gutta-percha have been the standard material of choice for root canal obturation. Canal filling has been aimed at maximizing the amount of gutta-percha and minimizing the amount of sealer. However recently, single cone technique has been introduced that include calcium silicate-based sealer and single gutta-percha cone. It is important to select an obturation technique that offers consistency and is easy to use. From the standpoint of appropriate technology, the single cone technique is thought to be useful for general dentist.

  • PDF

극저온 냉동기용 냉매압축기의 개발 (Development of Neon Compressor for Reverse Brayton Cryocooler)

  • 김승우;박기철;이기호;김경수;김동권
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.237-243
    • /
    • 2002
  • A centrifugal compressor of 50HP for reverse brayton cryocooler using neon as a coolent has been developed. It has relatively low total-to-total pressure ratio but mass flow rate is very small and the voting gas, neon, has greater specific heat ratio than air. It was essential to have very high rotational speed of 100,000 RPM. The efficiency of compressor has great effects on overall system and the COP of cryocooler. To meet the design requirement of the compressor efficiency and to minimized the required rotational speed, highly efficiency impeller having low specific speed was designed. To maintain the overall system efficient high, gas bearing of bump type and high speed permanent magnet synchronus motor was developed and adopted. In this paper, design and performance prediction results of the compressor impeller is presented.

  • PDF

Identification of Noise Sources in Scroll Compressor for Air-Conditioner

  • Lee, Jin-Kab
    • Journal of Mechanical Science and Technology
    • /
    • 제14권6호
    • /
    • pp.597-604
    • /
    • 2000
  • Low noise of air-conditioners is one of the most important issues because of the users' strong demand. The main source of noise in an air-conditioner is the compressor. Therefore, noise reduction in a compressor is quite significant as an element technology in the air-conditioner field. Recently, scroll compressors are widely used, because they feature low noise, due to less pulsation of gas pressure, than that of rotary compressors. For reduction of noise, the source of noise must be identified. This paper presents a detailed analysis to identify the noise source and shows the dominant factors of noise of the scroll compressor, which will make it possible to design a scroll compressor with low noise.

  • PDF