• Title/Summary/Keyword: Hepatitis B Surface Antigens

Search Result 13, Processing Time 0.025 seconds

Distribution of Antibodies Against Hepatitis B virus and Hepatitis C virus in Human Sera (사람 혈청내 B형과 C형 간염바이러스에 대한 항체분포)

  • Choi, Jin-Sub;Seong, In-Wha
    • The Journal of Korean Society of Virology
    • /
    • v.27 no.2
    • /
    • pp.129-135
    • /
    • 1997
  • Serum samples from 123 males and 123 females collected by age in 1996 were analyzed for antibodies against surface antigen of Hepatitis B virus and C22-3, C200 antigens of Hepatitis C virus. Sera from the children under the age of 10 showed 30% seropositivity to the surface antigen of Hepatitis B virus, 33.3% in $10{\sim}19$ year group, 20% in $20{\sim}29$ year group, 17.6% in $30{\sim}39$ year group, 3.3% in $40{\sim}49$ year group, 5.9% in $50{\sim}59$ year group, 8,3% in $60{\sim}69$ year group, 2.9% in $70{\sim}79$ year group, but antibody could not found in $80{\sim}86$ year group. 12 out of 123 male sera were positive, 19 out of 123 female sera were positive and overall rate of positivity of antibody against surface antigen of Hepatitis B virus was 12.6%. Serum samples from peoples under the age of 30 had not antibody against C22-3, C200 antigens of Hepatitis C virus. The positivity rate was 2.9% in $30{\sim}39$ year group. 5 out of 30 sera from $40{\sim}49$ year age group were positive, and 3 positive sera showed extremely high titer (1:524,288) but the titers of two remaining sera were 1:32, 1:8,192 respectively. 5.9% was positive in $50{\sim}59$ year group, 8.3% in $60{\sim}69$ year group, 11.8% in $70{\sim}79$ year group but all negative in $80{\sim}86$ year group 6 out of 123 male sera were positive (4.9%), 9 out of 123 female sera were positive (7.3%). Overall rate of positivity of antibody against C22-3, C200 antigen of Hepatitis C virus was 6.1 %. None out of 246 sera had both antibodies against Hepatitis B virus and Hepatitis C virus.

  • PDF

A Study on the Trend of Changes in the Positive Rate of Hepatitis B Surface Antigens and Antibodies over the Last 9 Years in One Health Care Center

  • Kang-Sil Lee;Sang-Ha Kim;Young-Bin Yu;Young-Kwon Kim
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.314-320
    • /
    • 2023
  • The purpose of this study was to provide basic data on hepatitis B infection control in the community through the results of the hepatitis B surface antigen and antibody tests conducted at the Cheongyang-County Health Medical Center. From 2012 to 2020, we retrospectively analyzed the HBsAg, HBsAb, HBeAg, HBeAb, and HBV DNA results of 7,329 hepatitis B-related testers. Among 7,329 subjects, the HBsAg positivity rate was 1.7%, and the positivity rate according to age was the highest at 4.4% in their 30s, 4.2% in their 40s, 4.1% in their 50s, 2.0% in their 60s, 1.9% in their 70s and over, and 10 it was shown in the order of 0.3% from less than large. The HBsAb positivity rate was 43.1% for men, 38.2% for men, and 46.7% for women (P<0.001). To summarize the above results, for infection control of hepatitis B in Cheongyang-County, hepatitis surface antigen proton management is required for those in their 30s or older, and it is thought that efforts to acquire immunity are necessary for those in their 20s or younger.

Immunological Properties of Recombinant Hepatitis B Surface Antigen Expressed in Mammalian Cell(C127)

  • Lee, Young-Soo;Kim, Byong-Kak;Choi, Eung-Chil
    • Archives of Pharmacal Research
    • /
    • v.21 no.5
    • /
    • pp.543-548
    • /
    • 1998
  • We examined the immunological properties of the recombinant hepatitis B surface antigen (r-HBsAg) which was expressed in mammalian cell (C127). The cross-immunity of r-HBsAg and plasma-derived hepatitis B surface antigen (p-HBsAg) were tested using Western blotting and ELISA with guinea pig polyclonal antibody and naturally infected human-derived antibody and the both antigens show the same results in their response pattern and intensity, which indicate they have a good cross-immunity. from the measurement of $ED_{50}$ after formalin- or heat-inactivation, both r-HBsAg and p-HBsAg and p-HBsAg showed $ED_{50}$ of 0.2-0.3 in formalin-inactivaton, while r-HBsAg was 0.05-0.09 and p-HBsAg was 0.03-0.07 in heat-inactivation, which means heat-inactivation method is 3-4 times superior in immunogenicity. In the immunopersistency test performed in guinea pig for the period of 3 months with two different adjuvants, antibody titer was 34.2 with muramyl dipeptide adjuvant, which was 1.8 times greater than the antibody titer of 18.9 with $AIPO_{4}$ adjuvant. the mutagenicity of r-HBsAg has the same cross-immunity with p-HBsAg, and heat-inactivation method and muramyl dipeptide adjuvant allow development of r-HBsAg vaccine with excellent immunogenicity.

  • PDF

Phylogenetic Analysis of Hepatitis B Virus Genome Isolated from Korean Patient Serum

  • Kim, Seon-Young;Kang, Hyen-Sam;Kim, Yeon-Soo
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.6
    • /
    • pp.823-828
    • /
    • 2000
  • The complete nucleotide sequence of hepatitis B virus DNA isolated from Korean patient serum was determined and characterized, and its phylogenetic relation was then investigated. The viral genome was 3,215 base pairs long and included four well known open reading frames (i.e. surface antigens, core antigens, X protein and DNA polymerase). The sequence of the surface antigen showed that the HBV genome under investigation, designated HBV 315, was characteristic of subtype adr. A phylogenetic analysis using the total genome sequence revealed that HBV315 was grouped into genomic group C together with isolates from Japan, China, Thailand, Polynesia, and New Caledonia. The mean percent similarity between HBV315 and other HBV isolates in genomic group C was 97.25%, and that with other genomic groups ranged from 86.16% to 91.25%. The predicted amino acid sequences of HBV315 were compared with two closely related subtype adr isolates, M38636 and D12980. The results showed that the X gene product was identical in the three strains, while there were significant amino acid sequence differences between HBV315 and M38636 in the Pre-S1 and Pre-S2 regions.

  • PDF

Conformation of Group "a" Epitope in Hepatitis B Surface Antigen

  • Chun, Mun-Ho;Park, Won-Bong;Bok, Jin-Woo;Kim, Ha-Won;Choi, Eung-Chil;Kim, Byong-Kak
    • Archives of Pharmacal Research
    • /
    • v.15 no.4
    • /
    • pp.347-355
    • /
    • 1992
  • To elucidate structure of group "a" epitope, mouse antibodies that express idiotype monoclonal antibody and anti-idiotype monoclonal antibody against the group specific "a" determinant were purified by hydroxyapatite column. To obtain hepatitis B surface antigens (HBsAg). HBsAg positive blood was sequencially purified by ammonium sulfate precipitation, hydroxyapatite, sepharose 4B column chromatography and ultracentrifugation. The major protein (p25) and glycoprotein (gp30) of HBsAg were isolated by concanavalin-A-sepharose 4B. The ability of p25-gp30 among the HBsAg to inhibit the idiotype-anti-idiotype reaction was dependent on conformation, since reduced and alkylated p25-gp30 virtualy lost their inhibitory capacity when compared to native HBsAg. The data suggest that hepatitis B antigen is a conformational antigen critically dependent upon the disulfide bonds of p25-gp30.

  • PDF

Report on the External Quality Assessment Scheme of Hepatitis Viral Markers in Korea, (2016-2017) (간염바이러스 항원항체검사 신빙도조사 결과보고 (2016-2017))

  • Cho, Eun-Jung;Choi, Ae Ran;Ryu, Ji Hyeong;Yun, So Jeong;Lee, Woochang;Chun, Sail;Min, Won-Ki;Oh, Eun-Jee
    • Laboratory Medicine and Quality Assurance
    • /
    • v.40 no.2
    • /
    • pp.51-69
    • /
    • 2018
  • As part of the immunoserology program of the Korean Association of External Quality Assessment Service, we organized two trials on the external quality assessment of hepatitis viral markers in 2016 and 2017. The hepatitis viral antigens and antibodies program consisted of 10 test items. We delivered two and three types of pooled sera specimens to 965 and 965 institutions for the first and second trials of external proficiency testing in 2016, respectively. The number of participating laboratories was 915 (94.8%) and 913 (95.0%) in the first and second trials in 2016, respectively. We also delivered three kinds of pooled sera specimens to 936 and 1,015 institutions for the first and second trials of external proficiency testing in 2017, respectively. The number of participating laboratories was 920 (98.3%) and 996 (98.1%) in the first and second trials in 2017, respectively. The most commonly tested items were hepatitis B surface antigen, followed by the antibodies to hepatitis B surface antigen, anti-hepatitis C virus, hepatitis B envelope antigen, antibodies to hepatitis B envelope antigen, anti-hepatitis A virus and antibodies to hepatitis B core antigen. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay and the electrochemiluminescence immunoassay, but they yielded a few-false positive results due to the matrix effect. The immunochromatographic assay yielded false-negative results for anti-hepatitis A virus due to low sensitivity. Continuous improvement in the quality of viral hepatitis testing through participation in the survey seems necessary.

Preparation of Surface Functionalized Gold Nanoparticles and their Lateral Flow Immunoassay Applications (표면 개질된 금나노입자의 제조 및 이의 측방유동면역 센서 응용)

  • Kim, Dong Seok;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.97-102
    • /
    • 2018
  • In this work, the surface of gold nanoparticles (AuNPs) was modified with small molecules including mercaptoundecanoic acid (MUA) and L-lysine for the development of highly sensitive lateral flow (LF) sensors. Uniformly sized AuNps were synthesized by a modified Turkevich-Frens method, showing an average size of $16.7{\pm}2.1nm$. Functionalized AuNPs were then characterized by transmission electron microscopy, UV-vis spectroscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. The stable conjugation of AuNPs and antibodies was obtained at pH 7.07 and the antibody concentration of $10{\mu}g/mL$. The functionalized AuNP-based LF sensor exhibited lower detection limit of 10 ng/mL for hepatitis B surface antigens than that of using the bare AuNP-based LF sensor (100 ng/mL).

Quadrivalent Combined Vaccine, Including Diphtheria Toxoid, Tetanus Toxoid, Detoxified Whole Cell Pertussis, and Hepatitis B Surface Antigen

  • Bae, Cheon-Soon;Lim, Gwan-Yeul;Kim, Jong-Su;Hur, Byung-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.3
    • /
    • pp.338-343
    • /
    • 2003
  • Various factors, such as the adsorption pH, adjuvant dose, and adjuvant age, which affect the adsorption degree and immunogenicity of an antigen, were investigated. In addition, the effect of pH, antigen content, and adjuvant content on immunogenicity was also studied through animal experiments. Within the ranges studied, a low pH for adsorption, freshly preformed gel, and low pH formulation for the combined DTwP-HepB vaccine were preferrable for the adsorption of the antigens. In addition, a higher DT content was found to have a positive effect on the HBsAg immunogenicity in the combined vaccine. Accordingly, considering the factors affecting the adsorption rate and immunogenicity of the antigens, a novel DTwP-HepB vaccine (40 Lf/ml of diphtheria toxoid, 15 Lf/ml of tetanus toxoid, 20 OU/ml of detoxified whole cell pertussis, $24\;\mu\textrm{g}$ of HBsAg, $24\;\mu\textrm{g}\;Al/ml\;of \;Al(OH)_3\;gel,\;776\;\mu\textrm{g}\; Al/ml\;of\;AIPO_4\;gel$, and pH 7.1) was developed, whose immunogenicity was comparable to the case of administrating, separately and simultaneously, a combined DTwP vaccine (40 Lf/ml of diphtheria toxoid, 15 Lf/ml of tetanus toxoid, 20 OU/ml of detoxified whole cell pertussis, $300\;\mu\textrm{g}\;Al/ml\;of\; AIPO_4\;gel$, and pH 7.1) and mono HepB vaccine [$Hepavax^{\circledR},\;24\;\mu\textrm{g}/ml$ of HBsAg and $500\;\mu\textrm{g}\;Al/ml\;of\;Al(OH)_3\;gel$], which satisfies the potency criteria of the K-FDA for a combined DTwP vaccine and mono HepB vaccine.

Modulation of Immune Response Induced by Co-Administration of DNA Vaccine Encoding HBV Surface Antigen and HCV Envelope Antigen in BALB/c Mice

  • Nam, Sang-Hyun;Park, Jae-Hyun;Kang, Ju-Hye;Kang, Seog-Youn;Kim, Jae-Hong;Kim, So-Young;Ahn, Joon-Ik;Park, Ki-Sook;Chung, Hye-Joo
    • Archives of Pharmacal Research
    • /
    • v.29 no.11
    • /
    • pp.1042-1048
    • /
    • 2006
  • Plasmid DNA vaccines encoding the hepatitis B virus (HBV) surface and hepatitis C virus (HCV) envelope antigens, respectively, were constructed, and attempt were made to find the possibility of a divalent vaccine against HBV and HCV. The expression of each plasmid in Cos-1 cells was confirmed using immunocytochemistry. To measure the induced immune response by these plasmids in vivo, female BALB/c mice were immunized intramuscularly with $100\;{\mu}g$ of either both or just one of the plasmids. Anti-HBV and HCV-specific antibodies and related cytokines were evaluated to investigate the generation of both humoral and cellular immune responses. As a result, specific anti-HBV and anti-HCV serum antibodies from mice immunized with these plasmids were observed using immunoblot. The levels of IL-2 and RANTES showing a $Th_{1}$ immune response were significantly increased, but there was no change in the level of IL-4 ($Th_{1}$ immune response) in any of the immunized groups. Compared with each plasmid DNA vaccine, the combined vaccine elicited similar immune responses in both humoral and cell-mediated immunities. These results suggest that the combined DNA vaccine can induce not only comparable immunity experimentally without antigenic interference, but also humoral and $Th_{1}$ dominant cellular immune responses. Therefore, they could serve as candidates for a simultaneous bivalent vaccine against HBV and HCV infections.

The Comparison of Results Among Hepatitis B Test Reagents Using National Standard Substance (국가 표준물질을 이용한 B형 간염 검사 시약 간의 결과 비교)

  • Lee, Young-Ji;Sim, Seong-Jae;Back, Song-Ran;Seo, Mee-Hye;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.203-207
    • /
    • 2010
  • Purpose: Hepatitis B is infection caused by Hepatitis B virus (HBV). Currently, there are several methods, Kits and equipments for conducting Hepatitis B test. Due to ununiformed methods, it would cause some differences. To manage these differences, it needs process evaluating function of test system and reagent using particular standard substance. The aim of this study is to investigate tendency of RIA method's reagent used in Asan Medical Center through comparing several other test reagents using national standard substance. Materials and Methods: The standard substance in National Institute of Food and Drug Safety Evaluation's biology medicine consists of 5 things, 4 antigens and 1 antibody. We tested reagents using A, B company's Kits according to each test method. All tests are measured repeatedly to obtain accurate results. Results: Test result of "HBs Ag Mixed titer Performance panel" is obtained match rate compared S/CO unit standard with RIA method and EIA 3 reagents, CIA 2 reagents is that company A's reagent is 94.4% (17/18), 83.3% (15/18), B is 88.9% (16/18), 77.8% (14/18). Test result of "HBs Ag Low titer Performance panel" is obtain that EIA 2 reagents is shown 7 posive results, CIA 3 reagents is 11, and RIA method's company A's reagent is 3, B is 2 of 13 in low panel. "HBV surface antigen 86.76 IU/vial" tested dilution. A is obtain positive results to 600 times(0.14 IU/mL), B is 300 times (0.29 IU/mL). Case of "HBV human immunoglobulin 95.45 IU/vial", A is shown positive result to 10,000 times (9.5 mIU/mL) and B is 4,000 times (24 mIU/mL). Test result of "HBs Ag Working Standards 0.02~11.52 IU/mL" is shown that Company A's kit concentration level was 0.38IU/mL, company B was 2.23 IU/mL and higher level of concentration was positive results. Conclusion: When comparing various test reagents and RIA method according to National Standard substances for Hepatitis B test, we recognized that there were no significant trends between reagents. For hepatitis B virus antigen-antibody titers even in parts of the test up to 600 times the antigen, antibodies to 10,000 times the maximum positive results could be obtained. Therefore, we confirmed that results from Asan Medical Center are performed smoothly by reagents and system for hepatitis B virus test.

  • PDF