• Title/Summary/Keyword: Hemosome

Search Result 5, Processing Time 0.019 seconds

Enhancement of Gas Transfer Efficiency in an Intravascular Lung Assist Device using Blood Substitutes (혈관내의 폐보조장치에서 혈액대용물질을 사용한 기체전달 효율향상)

  • 김기범;박재관;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.391-399
    • /
    • 2003
  • Intravascular oxygenation represents an attractive. alternative support modality for therapy originated with acute respiratory distress syndrome(ARDS). However. the clinical study concluded that more gas exchange was needed for intravascular oxygenation to be clinically effective in ARDS treatment. In this study, we tried to enhance gas exchange on the VIVLAD using microencapsulation of hemoglobin and perfluorocarbon emulsion(PFC emulsion). Blood gas measurements were performed by collecting blood samples from the arterial and venous sides of the circuit, and processing them in a blood/gas analyzer. The function of hemosome. blood/hemosome mixed solution. and blood/PFC emulsion mixed solution were tested by an oxygen dissociation curve using a blood/gas analyzer. As a result, it was shown that the oxygen transfer of hemosome and blood/hemosome mixed solution were higher than that of whole blood. Also. it showed that the carbon dioxide transfer of whole blood/PFC emulsion mixed solution was higher than that of others. Therefore, we determined that hemosome and PFC emulsion could increase oxygen transfer and carbon dioxide transfer. respectively.

Characteristics of Synthesized Red Cells Using Bovine Hemoglobin as Oxygen Carrier

  • Cho, Eng-Haeng;Hah, Jong-Sik;Kim, Ku-Ja
    • The Korean Journal of Physiology
    • /
    • v.26 no.1
    • /
    • pp.37-44
    • /
    • 1992
  • The encapsulation of the Purified bovine hemoglobin with Phospholipids obtained from egg folk was performed using a rotary vacuum evaporator. The prepared Hb-containing liposome (hemosome) had good properties as artificial red blood cell. The shape and size of the hemosomes were measured by a phase contrast microscope and image analyzer. The function of the hemosome as oxygen carrier was tested by measuring oxygen saturation curve with blood gas analyzer and infusing it into rats. The prepared hemosome was 1.184 + 0.423 ${\mu}m$ in diameter and round in shape. $P_{50}$ value of the hemosome solution was 28 mmHg. The synthesized red cells seem to function as oxygen carrier, because the severely bled rats were prolonged in their life by transfusion of the hemosome solution containing bovine hemoglobin.

  • PDF

Estimate of Characteristics and Manufacture of Blood Substitutes (혈액대용물질의 제조 및 특성 평가)

  • Kim, Gi-Beum;Park, Jai-Koan;Kim, Seong-Jong;Kim, Jong-Soo;You, Il-Soo;Kim, Min-Ho;Hong, Chul-Un;Kim, Jin-Shang;Kang, Hyung-Sub
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.626-632
    • /
    • 2008
  • The purpose of this study was to enhance gas exchange by producing hemosome, a hemoglobin microencapsulated with phospholipid of egg, and perfluorocarbone(PFC) emulsion solution. In the experiment, stable emulsion solution with 437 nm of mean particle size could be produced by Flusol-DA sonication, and shortening of emulsion time could be attained with higher stability as well. $0.8{\mu}m$ sized hemosome could be produced by microencapsulation of hemoglobin with phospholipid extracted from egg yolk. The pattern of oxygen saturation curve of hemosome was S shape, which is similar to that found in normal blood, and $P_{50}$ was measured to be 24 mmHg. The oxygen saturation in the mixed solution of hemosome and blood in 1:4(V/V%) ratio was similar to that of normal blood, and the same result was found in the mixed solution of PFC emulsion and blood in 1:4(V/V%) ratio.

Synthesis and Use of Artificial Red Cells (인공적혈구의 제조 및 이용)

  • Hah, Jong-Sik;Cho, Eng-Haeng;Kim, Ku-Ja
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.15-26
    • /
    • 1990
  • Hemoglobin was purified from the outdated human red blood cells. Phospholipids were purified from egg yolk and stored in chloroform. The artificial red blood cells (hemosome) were prepared by encapsulation of hemoglobin with phospholipid mutilayer using rotary vacuum evaporator. The shape and size of hemosomes were measured by phase contrast microscope and image analyzer. The function of hemosomes was tested by measuring oxygen dissociation curve using blood gas analyzer. In order to test whether hemosomes are useful as blood substitute they were infused into rats of which one third of total blood were drawn. The results obtained are summarized at followings. 1) Hemosomes were spherical shape and their mean diameter was 0.7 um. 2) Oxygen dissociation curve of hemosomes showed the same figure as that of normal red blood cells. 3) All rats given 1/3 transfusion with hemosomes survived until sacrificed whereas three of four rats given 1/3 transfusion with saline died within 1 hour and the rest of them died within 24 hours.