• Title/Summary/Keyword: Hemodynamic Characteristics

Search Result 98, Processing Time 0.027 seconds

Identification of risk factors and development of the nomogram for delirium

  • Shin, Min-Seok;Jang, Ji-Eun;Lee, Jea-Young
    • Communications for Statistical Applications and Methods
    • /
    • v.28 no.4
    • /
    • pp.339-350
    • /
    • 2021
  • In medical research, the risk factors associated with human diseases need to be identified to predict the incidence rate and determine the treatment plan. Logistic regression analysis is primarily used in order to select risk factors. However, individuals who are unfamiliar with statistics outcomes have trouble using these methods. In this study, we develop a nomogram that graphically represents the numerical association between the disease and risk factors in order to identify the risk factors for delirium and to interpret and use the results more effectively. By using the logistic regression model, we identify risk factors related to delirium, construct a nomogram and predict incidence rates. Additionally, we verify the developed nomogram using a receiver operation characteristics (ROC) curve and calibration plot. Nursing home, stroke/epilepsy, metabolic abnormality, hemodynamic instability, and analgesics were selected as risk factors. The validation results of the nomogram, built with the factors of training set and the test set of the AUC showed a statistically significant determination of 0.893 and 0.717, respectively. As a result of drawing the calibration plot, the coefficient of determination was 0.820. By using the nomogram developed in this paper, health professionals can easily predict the incidence rate of delirium for individual patients. Based on this information, the nomogram could be used as a useful tool to establish an individual's treatment plan.

Short and Intermediate Term Results of the ATS Heart Valve Replacement (ATS 인공 심장 판막의 단기 및 중기 임상성적)

  • Lim, Chang-Young;Moon, Seung-Chul;Yang, Jin-Young;Koo, Won-Mo;Kim, Dae-Sig;Lee, Gun;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

Simple Interrupted Suturing for Aortic Valve Replacement in Patients with Severe Aortic Stenosis

  • Lee, Jun Oh;Lee, Chee-hoon;Kim, Ho Jin;Kim, Joon Bum;Jung, Sung-Ho;Joo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.332-338
    • /
    • 2020
  • Background: Attaining an adequate effective orifice area (EOA) is definitive goal in aortic valve replacement (AVR). The simple interrupted suture (SIS) technique could be a solution to achieve this goal, but limited data are available in the literature. This study aimed to compare hemodynamic differences between the SIS and non-everting mattress suture (NMS) techniques. Methods: From our database, 215 patients who underwent AVR for severe aortic stenosis were extracted to form the overall cohort. From March 2015 to November 2016, the SIS technique was used in 79 patients, while the NMS technique was used in 136 patients. Hemodynamic outcomes were evaluated, as detected by transthoracic echocardiography and computed tomography. Results: There were no significant differences in baseline characteristics between the 2 groups. On immediate postoperative echocardiography, the SIS group showed a significantly wider EOA (1.6±0.4 vs. 1.4±0.5 ㎠, p=0.007) and a lower mean pressure gradient (PG) (13.3±5.4 vs. 17.0±6.0 mm Hg, p<0.001) than the NMS group. On follow-up echocardiography, the SIS group continued to have a wider EOA (1.6±0.4 vs. 1.4±0.3 ㎠, p<0.001) and a lower mean PG (11.0±5.1 vs. 14.1±5.5 mm Hg, p<0.001). There was no significant difference in paravalvular leakage. Conclusion: The SIS technique for AVR was associated with a wider EOA and a lower mean PG. The SIS technique could be a reasonable option for AVR.

Clinical Efficacy of Transdermal Clonidine (St 155 BS) for Anesthetic Management in Hypertensive Patients (고혈압 환자 마취시 Transdermal Clonidine (St 155 BS)의 임상적 유용성)

  • Lee, Hyun-Hwa;Kim, Dong-Ok;Kim, Keon-Sik;Choi, Young-Kyoo;Shin, Ok-Young;Kwon, Moo-Il;Lee, Doo-Ik
    • The Korean Journal of Pain
    • /
    • v.6 no.2
    • /
    • pp.231-236
    • /
    • 1993
  • Clonidine, a centrally-acting antihypertensive agent known to reduce central sympathetic outflow and modulate presynaptic transmitter's release, has shown to suppress central noradrenergic hyperactivity induced by immobilization stress in animals, by decreasing the MAC of halothane and the dose of narcotics required to prevent reflex cardiovascular response to noxious stimuli, and to have potent analgesic properties in humans. These characteristics suggest that clonidine might be a useful adjunct to the anesthetic management of patients with preexisting hypertension. Accordingly, we determined the clinical efficacy and safety on analgesia, sedation and hemodynamic stability in the perioperative period. Thirty patients(ASA physical status II-III) with a history of arterial hypertension, scheduled for elective orthopedic surgery were randomly assigned to two groups. We applied CPA-clonidine patch($6.9\;mg/cm^2$, 0.2 mg delivered daily) or placebo patch to each groups, 48 hours prior to induction of anesthesia. Antihypertensive medication was continued until the morning of the scheduled surgery. All patients received premedication of atropine and lorazepam, and induced anesthesia with thiopental and succinylcholine, and maintained with enflurane and 50% nitrous oxide, while sustaining the BP and pulse rate at acceptable range. For the relief of pain postoperatively, diclofenac and fentanyl were administered intramuscularly on demand. The results were as follows: 1) The change of hemodynamic responses in clonidine group was less compared to the placebo group. 2) Intraoperative anesthetic requirement for enflurane in clonidine group were significantly lower than placebo group. 3) Postoperative analgetic requirement in clonidine group were significantly lower than placebo group. In clonidine group, 5 cases out of 15 cases were required no analgetics, and the incidence of administration of additional fentanyl was decreased to 5 cases, comparing with 10 cases in placebo group.

  • PDF

Flow Visualization of Arteriovenous Grafting Using PIV Technique (PIV 기법을 이용한 동정맥루 문합에 대한 유동가시화)

  • Jeon, Min-Gyu;Kim, Hyoung-Ho;Suh, Sang-Ho;Choi, Young Ho;Lee, Hyun-Jin;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.985-990
    • /
    • 2013
  • An arteriovenous fistula is artificially produced using a graft for hemodialysis in patients. In an arteriovenous graft (AVG), the angle of its arterial or venous anastomosis play an important role in producing flows inside blood vessels, through which a stenosis may occur. Most studies thus far have focused on CFD results. In this study, a PIV technique is used to analyze the hemodynamic characteristics at the arterial or venous anastomosis of an AVG having an angle of $30^{\circ}C$. For flow dynamic similarity, the Reynolds number is set to be the same for real and simulated flows. A PIV experiment is performed with a control valve in the arterial part. In conclusion, the recirculation flow appeared in the bifurcation area and the total blood velocity changed according to the extent of valve opening.

Influences of Geometric Configurations of Bypass Grafts on Hemodynamics in End-to-Side Anastomosis

  • Choi, Jae-Sung;Hong, Sung-Chul;Kwon, Hyuck-Moon;Suh, Sang-Ho;Lee, Jeong-Sang
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.89-98
    • /
    • 2011
  • Background: Although considerable efforts have been made to improve the graft patency in coronary artery bypass surgery, the role of biomechanical factors remains underrecognized. The aim of this study is to investigate the influences of geometric configurations of the bypass graft on hemodynamic characteristics in relation to anastomosis. Materials and Methods: The Numerical analysis focuses on understanding the flow patterns for different values of inlet and distal diameters and graft angles. The Blood flow field is treated as a two-dimensional incompressible laminar flow. A finite volume method is adopted for discretization of the governing equations. The Carreau model is employed as a constitutive equation for blood. In an attempt to obtain the optimal aorto-coronary bypass conditions, the blood flow characteristics are analyzed using in vitro models of the end-to-side anastomotic angles of $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$. To find the optimal graft configurations, the mass flow rates at the outlets of the four models are compared quantitatively. Results: This study finds that Model 3, whose bypass diameter is the same as the inlet diameter of the stenosed coronary artery, delivers the largest amount of blood and the least pressure drop along the arteries. Conclusion: Biomechanical factors are speculated to contribute to the graft patency in coronary artery bypass grafting.

Central Venous Catheterization before Versus after Computed Tomography in Hemodynamically Unstable Patients with Major Blunt Trauma: Clinical Characteristics and Factors for Decision Making

  • Kim, Ji Hun;Ha, Sang Ook;Park, Young Sun;Yi, Jeong Hyeon;Hur, Sun Beom;Lee, Ki Ho
    • Journal of Trauma and Injury
    • /
    • v.31 no.3
    • /
    • pp.135-142
    • /
    • 2018
  • Purpose: When hemodynamically unstable patients with blunt major trauma arrive at the emergency department (ED), the safety of performing early whole-body computed tomography (WBCT) is concerning. Some clinicians perform central venous catheterization (CVC) before WBCT (pre-computed tomography [CT] group) for hemodynamic stabilization. However, as no study has reported the factors affecting this decision, we compared clinical characteristics and outcomes of the pre- and post-CT groups and determined factors affecting this decision. Methods: This retrospective study included 70 hemodynamically unstable patients with chest or/and abdominal blunt injury who underwent WBCT and CVC between March 2013 and November 2017. Results: Univariate analysis revealed that the injury severity score, intubation, pulse pressure, focused assessment with sonography in trauma positivity score, and pH were different between the pre-CT (34 patients, 48.6%) and post-CT (all, p<0.05) groups. Multivariate analysis revealed that injury severity score (ISS) and intubation were factors affecting the decision to perform CVC before CT (p=0.003 and p=0.043). Regarding clinical outcomes, the interval from ED arrival to CT (p=0.011) and definite bleeding control (p=0.038), and hospital and intensive care unit lengths of stay (p=0.018 and p=0.053) were longer in the pre-CT group than in the post-CT group. Although not significant, the pre-CT group had lower survival rates at 24 hours and 28 days than the post-CT group (p=0.168 and p=0.226). Conclusions: Clinicians have a tendency to perform CVC before CT in patients with blunt major trauma and high ISS and intubation.

Conversion of Total Atrio-pulmonary Connection to Total Cavo-pulmonary Connection - Review of Indications and Hemodynamic Characteristics - (심방-폐동맥 문합술 후 총 체정맥-폐동맥 문합술로의 전환 - 수술 적응증 및 혈역학적 특징의 검토 -)

  • Seo, Jung Ho;Lee, Jong Kyun;Choi, Jae Young;Sul, Jun Hee;Lee, Sung Kyu;Park, Young Whan;Cho, Bum Koo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.199-207
    • /
    • 2002
  • Purpose : Since the successful application of total atrio-pulmonary connection(TAPC) to patients with various types of physiologic single ventricles in 1971, post-operative survival rates have reached more than 90%. However some patients have been shown to present with late complications such as right atrial thrombosis, atrial fibrillation and protein losing enteropathy eventually leading to re-operation to control the long-term complications. The aim of this study is to review the results of total cavo-pulmonary connection(TCPC) in cases with late complications after TAPC. Methods : Between Jan. 1995 and Dec. 2000, 6 patients(5 males and 1 female) underwent cardiac catheterization $11{\pm}3$ months after conversion of previous TAPC to TCPC. We compared the hemodynamic and morphologic parameters before and after TCPC and also assessed the clinical outcomes. The indications for TAPC were tricuspid atresia in 4 cases and complex double-outlet right ventricle with single ventricle physiology in 2 cases. Results : There was no peri-operative mortality and all patients were clinically and hemodynamically improved at a mean follow-up of 11 months(range : 4 to 13). However, protein losing enteropathy recurred in 2 patients; this was were successfully treated with subcutaneous administration of heparin. Right atrial pressure before TCPC was $18.0{\pm}3.6mmHg$, but baffle pressure, corresponding to right atrial pressure decreased to $14.8{\pm}3.6mmHg$ after TCPC. The size of the pulmonary arteries did not regress after TCPC. Conclusion : The conversion of TAPC to TCPC improves clinical and hemodynamic status by decreasing the right atrial pressure and by providing a laminar cavo-pulmonary flow which enhances the effective pulmonary circulation in the so-called Fontan circulation.

Descending Aorta Blood Flow Characteristics before the Development of Necrotizing Enterocolitis in Preterm Neonates

  • Kim, Kyung Min;Kim, Hyo Sup;Yoon, Ji Hong;Lee, Eun-Jung;Yum, Sook Kyung;Moon, Cheong-Jun;Youn, Young-Ah;Kwun, Yoo Jin;Lee, Jae Young;Sung, In Kyung
    • Neonatal Medicine
    • /
    • v.25 no.2
    • /
    • pp.78-84
    • /
    • 2018
  • Purpose: To investigate the hemodynamic risk factors for necrotizing enterocolitis (NEC), we analyzed the characteristics of descending aorta (DA) blood flow in preterm neonates, who later developed NEC. Methods: This was an observational case-control study on 53 preterm neonates at a tertiary referral center. Clinical and echocardiographic data were collected from 23 preterm neonates with NEC (NEC group), and compared with those of 30 preterm neonates without NEC (control group). Echocardiography was done at a median (interquartile range) of 5 (3-9) days after birth and 2 (1-2.5) days before the diagnosis of NEC. Results: Basic clinical characteristics including gestational age, birth weight, Apgar score, breast feeding status, use of umbilical catheters, and mode of invasive ventilator care were similar between the groups. Compared with the control group, the lowest diastolic velocity of DA was significantly decreased, whereas the diastolic reverse flow and the ratio of diastolic reverse to systolic forward flows were significantly increased in the NEC group. In addition, the resistive index (RI) of DA was significantly increased in the NEC group and showed a positive association with the development of NEC. Multivariate logistic regression analysis showed that increasing RI of DA was an independent risk factor for the development of NEC (P=0.008). Conclusion: Significant changes in DA flow characteristics including decreased diastolic velocity and increased diastolic reverse flow along with increased peripheral vascular resistance were observed before the development of NEC in preterm neonates. These findings may help clinicians stratify in advance neonates at a risk of developing NEC and may help improve outcomes in these neonates.

Computational Hemodynamics in the Intracranial Aneurysm Model (뇌동맥류 모델에 대한 혈류역학 해석)

  • Seo, Taewon;Byun, Jun Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.927-932
    • /
    • 2013
  • The intracranial aneurysm model is extracted based on the Computed Tomography (CT) scan images. Computational fluid dynamics simulations were conducted under both steady and realistic flow conditions in ANSYS-FLUENT. The minimum wall shear stress in the intracranial aneurysm tended to occur in the aneurysmal region. The magnitude of wall shear stress along inner wall of the curvature in the right M1 segment of middle cerebral artery is approximately 20 times higher than that along both the proximal and distal walls. However, the magnitudes of the wall shear stress at the aneurysm region were considerably low. The blood flow has the complex distribution in the aneurysmal region during the systolic period. Complex helical flow patterns are observed inside the aneurysm. Through an analysis of the hemodynamic characteristics, one may predict the rupture of the cerebral aneurysms.