• Title/Summary/Keyword: Hemodialysis

Search Result 536, Processing Time 0.029 seconds

Evaluation of Cerebral Blood Flow Using Arterial Spin Labeling in Patients with Chronic Kidney Disease (만성 콩팥병 환자들에서 동맥 스핀 표지 기법을 이용한 뇌 관류상태의 평가)

  • Se Won Oh;Samel Park;Nam-jun Cho;Hyo-Wook Gil;Eun Young Lee;Hyung Geun Oh;Sung-Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.912-919
    • /
    • 2020
  • Purpose This study aimed to compare the brain perfusion status of patients with chronic kidney disease to a normal control group to identify any significant differences. Materials and Methods The perfusion state of the brain was measured by MRI using the arterial spin labeling technique in 36 patients undergoing hemodialysis due to chronic kidney disease and 36 normal controls. Images were then analyzed in a voxel-wise manner to detect brain areas showing significant perfusion differences between the two groups. Results Patients with chronic kidney disease showed increased perfusion in the form of large clusters across the right fronto-parieto-temporal lobe and the left parieto-occipital lobe. In addition, perfusion increased in the bilateral thalami, midbrain, pons, and cerebellum (p < 0.01, familywise error corrected). Conclusion Brain perfusion appears to increase in patients with chronic kidney disease compared to normal controls. Uremic toxicity is thought to be the cause of this increase as it can cause damage to the microscopic blood vessels and their surrounding structures.

Safety and Efficacy of the Percutaneous Manual Aspiration Thrombectomy Technique to Treat Thrombotic Occlusion of Native Arteriovenous Fistulas for Hemodialysis (혈액투석용 자가혈관 동정맥루의 혈전을 동반한 폐색에서 경피적 수동 흡인 혈전제거술의 안정성과 유용성)

  • Sang Eun Yoon;Sun Young Choi;Soo Buem Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.409-417
    • /
    • 2020
  • Purpose To evaluate the safety and efficacy of the percutaneous manual aspiration thrombectomy technique to treat thrombotic occlusion of native arteriovenous fistulas. Materials and Methods A retrospective review of 20 patients who underwent percutaneous manual aspiration thrombectomy for native thrombotic arteriovenous fistula occlusion from March 2012 to December 2017 was performed. We evaluated technical and clinical success rates and complications. The primary and secondary patency rates were calculated using the Kaplan-Meier analysis. Results Percutaneous manual aspiration thrombectomy was performed in 20 patients (n = 20) with concomitant balloon angioplasty. The overall technical and clinical success rates were both 85% (n = 17). The native arteriovenous fistulas, based on their site, were the left radiocephalic (n = 13), left brachiocephalic (n = 4), and right radiocephalic (n = 3) fistulas. An underlying stenosis was detected in the juxta-anastomotic venous site (n = 16), outflow draining vein (n = 12), and central vein (n = 4). The primary and secondary patency rates at 1, 3, 6, and 12 months were 100%, 70.6%, 70.6%, and 56.5% and 100%, 94.1%, 94.1%, and 86.9%, respectively. There were no complications associated with procedure. Conclusion Percutaneous manual aspiration thrombectomy is a safe and effective method to treat thrombotic native arteriovenous fistula occlusion.

Dilatation of Superior Ophthalmic Vein and Visual Disturbance by Central Venous Stenosis: A Case Mimicking Cavernous Sinus Dural Arteriovenous Fistula (상안정맥 확장 및 시력 저하를 보인 중심정맥협착: 해면경막 동정맥루로 오인된 증례 보고)

  • Young Hun Jeon;Kyung Sik Yi;Chi Hoon Choi;Yook Kim;Yeong Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1619-1627
    • /
    • 2021
  • Central venous stenosis is a relatively common complication in hemodialysis patients; however, jugular venous reflux (JVR) and increased intracranial pressure are rare, and associated progressive visual disturbance was reported in only a few cases. Here, we report a case of JVR with visual disturbance and increased intracranial pressure. Notably, the MRI was accompanied by a dilatation of the superior ophthalmic vein, which was mistaken for a cavernous sinus dural arteriovenous fistula (CSdAVF). The patient had JVR on time-of-flight MR angiography (TOF-MRA) and severe stenosis of the left brachiocephalic vein on conventional angiography. After balloon angioplasty for central venous stenosis, he was discharged after improvement of his visual disturbance. Although JVR due to central venous stenosis and CSdAVF might show similar symptoms, treatment plans are different. Therefore, it is important to distinguish radiologically based on a thorough review of MRI and TOF-MRA and confirm the central venous stenosis on cerebral angiography for the accurate diagnosis.

A Case of Carbamoyl Phosphate Synthetase 1 Deficiency with Novel Mutations in CPS1 Treated by Liver Cell Transplantation (신생아기에 새로운 CPS1 유전자 돌연변이가 확인되고, 간세포이식 시행 받은 Carbamoyl phosphatase synthetase 1 deficiency 1례)

  • Lee, Jisun;Yang, Aram;Kim, Jinsup;Park, Hyung-Doo;Lee, Sanghoon;Lee, Suk-Koo;Cho, Sung Yoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.17 no.1
    • /
    • pp.31-37
    • /
    • 2017
  • Carbamoyl phosphate synthetase 1 deficiency (CPS1D) is an autosomal recessive disorder of the urea cycle that causes hyperammonemia. Two forms of CPS1D are recognized: a lethal neonatal type and a less severe, delayed-onset type. Neonatal CPS1D cases often present their symptoms within the first days of life. Delayed-onset cases are predominantly adolescents or adults, and infantile delayed-onset cases are rare. Severe hyperammonemia in the neonatal period leads to serious brain damage, coma, and death if not treated promptly. Therefore, early diagnosis and acute treatment are crucial. Despite the improvement of treatments, including continuous hemodialysis, ammonia-lowering agents, and a low-protein diet, the overall outcome of severe forms of hyperammonemia often remains disappointing. As the liver is the only organ in which ammonia is converted into urea, liver transplantation has been considered as an elegant and radical alternative therapy to classical dietary and medical therapies. However, liver transplantation has many disadvantages, such as a considerable risk for technical complications and perioperative metabolic derangement, especially in neonates. Additionally, there is a lack of suitable donor organs in most countries. According to recent studies, liver cell transplantation is a therapeutic option and serves as a bridge to liver transplantation. Here, we report a Korean CPS1D patient with novel mutations in CPS1 who was treated by liver cell transplantation after being diagnosed in the neonatal period and showed a good neurodevelopmental outcome at the last follow-up at six months of age.

  • PDF

A Web-based Internet Program for Nutritional Assessment and Diet Prescription by Renal Diseases (웹기반의 신장질환별 영양평가 밑 식사처방 프로그램)

  • 한지숙;김종경;전영수
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.5
    • /
    • pp.847-885
    • /
    • 2002
  • The purpose of this study was to develop a web-based internet program for nutritional assessment and diet Prescription by renal diseases. Renal diseases were classified by nephrotic syndrome, renal failure, hemodialysis and peritoneal dialysis. The system consisted of five parts according to their functions and contents. The first part is to assess the general health status such as body weight, obesity index, basal metabolic rate and total energy requirement by the input of age, sex, height, weight and degree of activity. The second part was designed to investigate dietary history of patient, that is, to find out his inappropriate dietary habit and give him some suggestions for appropriate dietary behavior by investigating his dietary history. This part also offers the diet and nutrition management by personal status with renal disease, and the information for food selection, snacks, convenience foods, dine-out, behavioral modification, cooking methods, food exchange lists and terms. The third part is evaluating their energy and nutrients intake by comparing with recommended dietary allowance for Koreans or standardized data for patient with renal disease. In this part, it is also analyzing energy and nutrients of food consumed by food group and meals, and evaluating the status of nutrient intake. The fort]1 one, a major part of the system, is implementing the diet and menu planning by using food exchange lists. This Part Provides the patient with menus lists and I day menu suitable to his weight, activity and the status of renal disease. The fifth part is providing information on energy and nutrients of foods and drinks, and top 20 foods classified by nutrients. These results are finally displayed as tabular forms and graphical forms on the computer screen.

Simple and Effective Surgical Repair with Vascular Graft Strip for Ischemic MR (인조혈관대를 이용한 허혈성 승모판막 폐쇄부전의 수술적 치료)

  • 민호기;이승훈;이주현;성기익;박계현;전태국;박표원;이영탁
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.646-650
    • /
    • 2003
  • Many surgical techniques for ischemic mitral regurgitation (IMR) have been used with their excellent results and advantages. Here, we report our simple posterior annuloplasty techniques using vascular graft strip with their early results. Material and Method: Twenty two patients (13 male) underwent the operations for IMR (excluding the papillary muscle rupture) from December 2001 to January 2003. Preoperative risk factors were low ejection fraction (<35%, n=9), hypertension (n=13), diabetes (n=9), and renal failure (Cr>2.5, n=4). The wide dissection beneath the both vena cavae and interatrial groove after bicaval cannulation enabled the easy exposure of mitral valve even in the small left atrium. After eight or nine interrupted sutures in posterior annulus for anchoring the 6 mm width vascular graft strip, symmetric (n=8) or asymmetric (n=14) annuloplasty were done. Combined surgeries were CABG (n=21), Dor procedures (n=3), tricuspid valve annuloplasty (n=1), Maze operation (n=1), and aorto-right subclavian artery bypass (n=1). Result: Except for one surgical mortality, all the patients were doing well and the mean grade of regurgitation was decreased from 2.95 to 0.88, however the ejection fraction had not changed significantly just before discharge. Post-operative valve function evaluated before discharge revealed no residual regurgitation in 8 (including 1 patient with mild stenosis due to over reduction), minimal in 11, mild in 2, and mild to moderate regurgitation in 1. One patient who had ischemic cardiomyopathy and renal failure died of the arrhythmia during the hemodialysis. Conclusion: These observations suggest that the annuloplasty with vascular graft strip could be a safe and cost effective techniques for ischemic mitral regurgitation. However, the long term evaluation for the mitral valve function should be defined for the final conclusion.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer (재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究))

  • Jung, Ha-Chung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF

The Characteristics of Blood Pressure Control in Chronic Renal Failure Patients Treated with Peritoneal Dialysis (복막 투석중인 만성 신부전 환자의 혈압 조절에 관한 연구)

  • Jung, Hang-Jae;Bae, Sung-Hwa;Park, Jun-Bum;Jo, Kyoo-Hyang;Kim, Young-Jin;Do, Jun-Young;Yoon, Kyung-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.333-341
    • /
    • 1999
  • Background and Methods: In order to evaluate characteristics and modulatory factors of blood pressure in peritoneal dialysis(PD), studies were conducted on the 69 patients who had underwent peritoneal equilibration test(PET). Results: The results were as follows; 1) All patients received an antihypertensive drug before PD, but, 15 of 69 patients successfully quit taking the antihypertensive drug after peritoneal dialysis. 2) During peritoneal dialysis, mean arterial pressure(MAP) was significantly decreased for the first 3 months, and this lasted for 1 year, and antihypertensive drug requirements were significantly decreased continuously up to 9 months(p<0.05). 3) After changing the modality from hemodialysis to peritoneal dialysis, MAP(mmHg, from $107.0{\pm}4.5$ to $98.6{\pm}8.8$, p<0.05), antihypertensive drug requirements(from $5.6{\pm}2.6$, to $2.0{\pm}2.5$, p<0.01) and erythropoietin dosages(Uint/week, from $4600{\pm}2660$ to $2000{\pm}1630$, p<0.05) were decreased. 4) Multiple logistic regression analysis showed that MAP(p<0.01) and daily ultrafiltration volume(p<0.05) can contribute to the determination of antihypertensive drug requirements. However the relationship between antihypertensive drug requirements and PET results or dialysis adequacy indices(weekly Kt/V, weekly creatinine clearance) was not revealed. Conclusion: In conclusion, the prescription of antihypertensive drugs should be considered according to daily ultrafiltration volume, especially during first year after initiating PD, and follow-ups for over a year may be needed.

  • PDF

Low Volume Peritoneal Dialysis in Newborns and Infants (신생아와 영아의 급성신부전증 치료를 위한 저용량 복막투석)

  • Park, Young-Hoon;Ahn, Soo-Ho;Shin, Son-Moon;Hah, Jeong-Ok
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.128-137
    • /
    • 1991
  • Peritoneal dialysis has been widely considered to be the dialytic treatment of choice for acute renal failure in infants and young children, because the technique is simple, safe and easily adapted for these patients. Also peritoneal dialysis in infants might have more effective ultrafiltration and clearance than in adults. In certain circumstances associated with hemodynamic instability, ordinary volume peritoneal dialysis(30-50 ml/kg body weight per exchange) or hemodialysis may not be suitable unfortunately. But frequent cycled, low volume, high concentration peritoneal dialysis may be more available to manage the hemodynamically untable acute renal failure of newborns and infants. Seven infants underwent peritoneal dialysis for hemodynamically unstable acute renal failure with low exchange volume($14.2{\pm}4.2ml/kg$), short exchange time(30 to 45 minutes) and hypertonic glucose solution(4.25% dextrose). Age was $1.9{\pm}1.3$ months and body weight was $4.6{\pm}1.6kg $. Etiology of acute renal failure was secondary to sepsis with or without shock(5 cases) and postcardiac operation(2 cases). Catheter was inserted percutaneously with pigtail catheter or Tenkhoff catheter by Seldinger method. Dialysate was commercially obtained Peritosol which contained sodium, chloride, potassium, magnesium, lactate and calcium. Net ultrafiltration(ml/min) showed no difference between low volume dialysis and control($0.27{\pm}0.09$ versus $0.29{\pm}0.09$) Blood BUN decreased from $95.7{\pm}37.5$ to $75.7{\pm}25.9mg/dl$ and blood pH increased from $7.122{\pm}0.048$ to $7.326{\pm}0.063$ after 24 hours of peritoneal dialysis. We experienced hyperglycemia which were controlled by insulin(2 episodes), leakage at the exit site(2), mild hyponatremia(1) and Escherichia coli peritonitis(1). Two children of low volume dialysis died despite the treatment. In our experience, low volume and high concentration peritoneal dialysis with frequent exchange may have sufficient ultrafiltration and clearance without significant complications in the certain risked acute renal failure of infants.

  • PDF