• Title/Summary/Keyword: Height of Microphone

Search Result 16, Processing Time 0.034 seconds

Microphone Array Design for Measurement of the Equivalent Source Height of Vehicle Noise (차량소음의 등가소음높이 측정을 위한 마이크로폰 배열 설계)

  • 윤종락;배민자
    • Journal of KSNVE
    • /
    • v.5 no.2
    • /
    • pp.197-206
    • /
    • 1995
  • Microphone array is designed to measure the equivalent source height of vehicle noise. The equivalent source position is defined for an arbirary distribution of acoustic sources above a perfectly reflecting plane and a microphone array for its measurement is developed. The normalized errors of the measured equivalent source heights are defined including the effects of background noise, the geometric near field, and source size. Normalized errors of the measured source heights obtained by a nemerical simulation for each parameter lead to optimization of the microphone spacing and to the design of an array which gives the equivalent source height as a function of frequency. The performance of the designed array is verified using the stationary loudspeaker experiments.

  • PDF

Analysis of Traffic Noise Propagation around Main Roads in Kwang-ju City

  • Choi, Hyung-II;Cheong, Kyung-Hoon
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • This paper describes an analysis of various factors affecting traffic noise propagation, including the distance from the road, existence of a direct path of noise propagation, density and height of buildings, and procedure for predicting the attenuation of noise levels from roads. The analysis is based on a multiple number of regression models, utilizing the quantification theory of the first kind. This study incorporates a large amount of survey data concerning traffic noise propagation. The survey of the traffic noise propagation around main roads was carried out in several residential areas, mainly in Kwangju. The attenuation of noise levels measured provided 691 usable data samples. A multiple regression analysis demonstrated that the distance from the road makes the most significant contribution to the attenuation of the noise level. The second contributor was found to be the existence of a direct path of noise propagation. The building density and average height of the buildings also affected the attenuation of the noise level considerably. Other factors, such as the height of the building behind the receiver microphone and the number of traffic lanes on the noise-source roads, did not contribute as much to the attenuation of the noise level as the factors mentioned avove.

  • PDF

Suggestion of assessment height for noise measurement according to the vertical radiation characteristics of railway noise (철도소음의 높이별 방사특성을 고려한 수음 평가 위치 제안)

  • Cho, Jun-Ho;Jang, Kang-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.29-37
    • /
    • 2014
  • Exact and precise noise measurement is the basis for the reduction measure R&D, impact assessment and prediction modeling for railway noise. In this study, research trend as well as national and international noise measurement standard are investigated. For the estimation of vertical radiation characteristics of railway noise, specially devised zig was used. From the noise measurement and analysis, exact noise height radiated from the railway was characterized. The obtained results will be used for the suggestion of the height of microphone position of railway noise measurements.

An Analysis of the Influence Factors of Floor Impact Sound Levels (바닥충격음레벨 영향요인 분석)

  • 김경우;최현중;양관섭;이승언
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.255-260
    • /
    • 2003
  • The regulation for floor impact sound level is expected to be amended to 50㏈(L$\_$i, Fmax, AW/) and below in heavy-weight impact sound and 58㏈(L'$\_$n, AW/) and below in light-weight impact sound in Korea. The purpose of this paper is to analyze the influence factors of floor impact sound levels in apartments. The influence factors were air pressure of bang machine, height of microphones, data acquisition rate, etc. The air pressure range of bang machine were from 2.2 Pa to 2.6 Fa. Five microphones were installed at a height of 0.5m, 0.7m, 0.9m, 1.2m, 1.5m or 1.7m from floor level. The floor impact sound level was varied about 1-3㏈(L$\_$i, Fmax, AW/) in heavy-weight impact sound according to the influence factors.

  • PDF

Investigation of receiving position in the measurement method for floor impact sound in a testing building (표준시험동 바닥충격음 측정위치에 대한 고찰)

  • Lee, Sin-Young;Yoo, Seung-Yup;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

A Study on Noise Propagation Properties of Hi-Speed Train (고속으로 운행하는 고속철도의 소음 방사특성 연구)

  • Park, Tae-Ho;Han, Jong-Won;Ryu, Hun-Jae;Ko, Jun-Hee;Chang, Seo-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2934-2940
    • /
    • 2011
  • The railway system in Korea is developing more and more rapidly. After development the next generation hi-speed train(HEMU-400X), Korea can compete against developed country. But, speed increasing will cause the greater rolling and aero dynamic noise. In this study shows that measurement noise of the KTX train by 300kn/h class, and KTX-Sancheon train by 350km/h class. The measurements are carried out on open area and noise protection barrier installed area. The microphones were placed at a distance of 3m from the center line of the track at a height of 0.5m above the upper surface of the rail and at a distance of 7.5m from the center line of the track at a height of each 0.6m above(Max 3.6m) the upper surface of the rail. One microphone was placed at a distance of 25m for check the environmental noise.

  • PDF

A study on the location of microphones in measurement considering the frequency characteristics of elevator noise in households (세대 내 승강기 소음 주파수특성을 고려한 측정 시 마이크로폰 위치에 관한 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.124-132
    • /
    • 2023
  • When the building becomes high, the number of households increases and they are adjacent to the elevator. So, frequency of use of elevators will increase. Elevator noise is bound to increase in the future. However, there are currently no legal standards for elevator noise or measurement and evaluation methods that can clearly measure elevator noise in Korea. Although some methods for measuring elevator noise are presented in KS F ISO 16032, this standard is not a standard established for elevator noise. It is a standard that integrates the overall measurement method of building equipment and equipment, and the position of the microphone is selected by the experimenter during measurement. Elevator noise is characterized by a low sound pressure level as the noise in the mid-low frequency band is important. However, even today, complaints from residents about elevator noise are increasing. In this study, the position of the microphone that can most sensitively pick up the elevator noise when measuring the elevator noise was studied. According to the distance from the wall and the height from the floor, a total of 9 microphone positions were measured and analyzed. As a result of the experiment, it was confirmed that the elevator noise has a very high influence in the 63 Hz band. The measured value at the center point was identified as a factor that lowered the overall elevator noise level value.

An Investigation of the Occlusal Sounds Produced by Mandibular Closing Movement in Adults (성인의 폐구운동시 발생되는 교합음에 관한 연구)

  • 신금배;이승우
    • Journal of Oral Medicine and Pain
    • /
    • v.8 no.1
    • /
    • pp.43-60
    • /
    • 1983
  • In order to obtain the basic data for diagnosis of occlusion the author investigated the occlusal sounds produced by mandibular closing movement from rest position to centric occlusion by using the Korotkoff sounds microphone electrodes and physiograph for Korean 20S without TMJ problems. And the author analyzed the correlation of the occlusal sounds with height, body weight, mandibular closing movement distance, maxillary sinus size and masseter muscle activities relating to the production of occlusal sounds. The obtained results were as follows : 1. The occlusal sounds prouduced by mandibular closing movements from rest position to centric occlusion were ranged from 3.08mV to 52.00mV, their maen value 19.07mV in right side, and ranged from 2.41mV to 18.33mV, their mean value 9.19mV in left side in group of Angel's class I occlusion subjects having right habitual side of mastication. 2. In general the occlusal sounds in the habitual side of mastication were greater than those in the opposite side. 3. The correlations of the occlusal sounds with height and maxillary sinus size were not significant. 4. The correaltions of the occlusal sounds with body weight, mandibular closing movement distance and masster muscle activities were significant.

  • PDF

Detection of External Sound Frequency by Using the Distributed Fiber Optic Sensor Net (분포형 광섬유 센서망을 이용한 외부 음향 주파수 탐지)

  • 이종길
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.569-576
    • /
    • 2004
  • In this paper, to detect external sound frequencies on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure was fabricated with a dimension of 50 cm in width and 50 cm in height. The optical fiber of 50m in length was distributed and fixed on the surface of the latticed structure. Single mode fiber, a laser with 1,550 nm in wavelength, 2 ${\times}$ 2 coupler were used. External sound signal, 240 Hz, 495 Hz, 1.445 kHz, 2k Hz, applied to the fiber optic sensor net and the detected optical signals were compared to the detected microphone signals against time and frequency domains. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

Development of Wireless Electronic Cardiogram and Stethoscope (ECGS) to Measure ECG Signal and Heart Sound (심전도와 심음을 측정하기 위한 무선 전자 심전도-심음 청진기 개발)

  • Cho, Han Seok;Kang, Young-Hwan;Park, Jae-Soon;Choi, Jin Gyu;Joung, Yeun-Ho;Koo, Chiwan
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.124-130
    • /
    • 2022
  • In this paper, we proposed a portable electronic cardiogram and stethoscope (ECGS) that can simultaneously perform the electrocardiogram (ECG) and auscultation tests to increase the reliability of diagnosis of heart disease. To measure the ECG and heart sound (HS) at the same time, three ECG electrodes and a microphone sensor were combined into a triangular shape with a width of 90 mm and a height of 97 mm that can be held in one hand. In order to prevent skin problems when they contact the patient's skin, a capacitive coupled electrode was selected as the ECG electrode and a silicone material was used in a chest piece with the microphone sensor. For the signals measured from the electrodes and the chest piece, filters were respectively configured to pass only the signals of 0.01-100 Hz and 20-250 Hz, which are frequency bands for ECG and HS. The filtered ECG and HS analog signals were converted into digital signals and transmitted to a PC using wireless communication for monitoring them. The HS could be auscultated simultaneously using an earphone. The monitored ECG had an SNR of about 34 dB and a P-QRS-T waveform is clearly visible. In addition, the HS had an SNR of about 28 dB and both S1 and S2 are clearly visible. It is expected that it can aid doctors' inexperience in analyzing the ECG and HS.