• 제목/요약/키워드: Height and location

검색결과 677건 처리시간 0.023초

Optimization of Sky-Bridge location at coupled high-rise buildings considering seismic vulnerability functions

  • Arada, Ahmad Housam;Ozturk, Baki;Kassem, Moustafa Moufid;Nazri, Fadzli Mohamed;Tan, Chee Ghuan
    • Structural Engineering and Mechanics
    • /
    • 제82권3호
    • /
    • pp.385-400
    • /
    • 2022
  • Sky-bridges between adjacent buildings can enhance lateral stiffness and limit the impact of lateral forces. This study analysed the structural capabilities and dynamic performances of sky-bridge-coupled buildings under various sets of ground motions. Finite Element (FE) analyses were carried out with the link being iteratively repositioned along the full height of the structures. Incremental dynamic analysis (IDA) and probabilistic damage distribution were also applied. The results indicated that the establishment of sky-bridges caused a slight change in the natural frequency and mode shapes. The sky-bridge system was shown to be efficient in controlling displacement and Inter-Storey Drift Ratio (%ISDR) and reducing the probability of damage in the higher floors. The most efficient location of the sky-bridge, for improving its rigidity, was found to be at 88% of the building height. Finally, the effects of two types of materials (steel and concrete) and end conditions (hinged and fixed) were studied. The outcomes showed that coupled buildings with a sky-bridge made of steel with hinged connection could withstand ground motions longer than those made of concrete with fixed connection.

초음속 유동장 내 평판/cavity를 이용한 연료-공기 혼합의 실험적 연구 (Experimental Study on Fuel-Air Mixing Using Flat Plate/Cavity in Supersonic Flow)

  • 김정우;정은주;김채형;정인석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.319-322
    • /
    • 2006
  • 초음속 연소가 성공하려면 1 ms의 시간 안에 충분한 연료-공기 혼합이 이루어져야 한다. 본 실험은 마하 1.92유동에서 헬륨을 수직 분사하여 연료-공기 혼합이 어떻게 이루어지는지 살펴보았다. 평판과 공동 두 가지 모델로 실험을 수행하였고, 슐리렌 가시화를 통해 사진을 찍었다. 압력은 초음속 덕트 내에서 충격파가 어떻게 생성되는지에 영향이 많았고, 침투 거리는 J가 커질수록 두꺼워졌다. 공동이 있는 경우 평판일 때보다 침투 거리가 더 컸다.

  • PDF

노년여성 흉부 체형유형화에 관한 연구(I) (A study on breast from classification of elderly womend)

  • 이경화
    • 대한인간공학회지
    • /
    • 제13권2호
    • /
    • pp.25-31
    • /
    • 1994
  • This research examines classifying and characterizing breast form's classification on elderly women, 242 subjects from 55 to 75 years of age participated. 27 direct anthropometric measurement were applied to classify the breast typesl. We analyzed measurement data using factor analysis, cluster analysis, analysis of variance. The results of the study were as follows. 1) 55-64 aged group was taller and higher than 65-79 aged group. Typical breast form in 55-64 aged group was more obese than breast form in 65-79 aged group. 2) We extracted 5 factors(obesity of breast, height of breast, height of breast items, location & size of breast, width of upper chest & shouldet length, height of breast & lower length of nipples) from total items through factor analysis. 3) Through cluster analysis, we categorized 3 clusters. Namely, type 1; characterized the best slender type, type 2; characterized middle sized type, type 3: characterized obesity type. Type 2 is the typical type on elderly women.

  • PDF

잡음영상에서 효과적인 에지검출을 위한 이표본 선형 순위 검정법 (Two-sample Linear Rank Tests for Efficient Edge Detection in Noisy Images)

  • 임동훈
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권4호
    • /
    • pp.9-15
    • /
    • 2006
  • 본 논문에서는 잡음영상에서 효과적인 에지검출을 위해 이표본 위치문제(two-sample location Problem)에서 잘 알려진 선형 순위 검정법(linear raft test)인 Wilcoxon 검정법, Median 검정법 그리고 Van der Waerden 검정법을 적용하고자 한다. 에지 존재 유무는 에지-높이 모수(edge-height parameter)를 사용한 모형 하에서 인접한 두 개의 근방영역간의 평균 차이를 검정함으로서 통계적으로 결정한다. 여기서 근방영역의 크기와 형태는 에지검출을 위한 계산 속도와 에지방향을 고려하여 적응성 있게(adaptively) 결정하였다. 통계적 방법들의 에지검출 성능을 평가하기 위해 자연영상(natural images)과 인조영상(synthetic images) 그리고 잡음이 추가된 영상에 대해 실험을 실시하고 비교 분석하였다.

  • PDF

Factors Affecting In vitro True Digestibility of Napiergrass

  • Chen, Chia-Sheng;Wang, Su-Min;Hsu, Jih-Tay
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권4호
    • /
    • pp.507-513
    • /
    • 2006
  • Changes of in vitro true digestibility (IVTD) of Napiergrass (Pennisetum purpureum) were determined by a filter bag system, and their relationships to chemical composition, leaf to stem ratio, plant height, geographic location, climatic factors and harvest interval were studied and used to develop prediction models for the crude protein (CP), acid-detergent fiber (ADF), and neutral-detergent fiber (NDF) contents and IVTD. Partitioning the total variance of IVTD of Napiergrass showed that 80% was attributable to the effect of harvest interval. Days of growth, plant height, leaf/stem ratio, CP, ADF and NDF of Napiergrass had highly significant relationships (p<0.01) with IVTD. The highest coefficient of correlation between the ADF, NDF, and IVTD of Napiergrass and growth degree days was obtained when the base temperature was set at $0^{\circ}C$. Growth degree days could predict ADF, NDF, and IVTD of Napiergrass more accurately than plant height, and plant height is not suitable to predict IVTD.

우리나라 동해안 중부 해역에서 6년간 연속 관측된 파랑의 특성 (Characteristics of Waves Continuously Observed over Six Years at Offshore Central East Coast of Korea)

  • 정원무;오상호;조홍연;백원대
    • 한국해안·해양공학회논문집
    • /
    • 제31권2호
    • /
    • pp.88-99
    • /
    • 2019
  • 동해안 남항진 해변에서 1.6 km 떨어진 수심 30.5 m 해역에서 초음파식 파고 파향계를 이용하여 2013년 2월부터 2018년 11월까지 연속 관측을 실시하여 취득된 파랑자료를 분석하였다. 파별분석법과 스펙트럼법에 의해 파고와 주기를 분석하고 두 방법에 의해 산정되는 파라메터 사이의 관계식을 선형 회귀분석에 의해 도출하였다. 또한 유의파고, 유의파주기, 첨두파향의 월별 및 연별 변동성을 분석하였다. 이에 더하여 유의파고와 유의파주기의 상관관계식을 새롭게 제시하고 유의파고에 대한 유의파주기의 변동성 및 확률분포 특성을 고찰하였다.

A Research on Curved Display Comparing to Flat Display Regarding Posture, Tilt Angle, Focusing Area and Satisfaction

  • Ahn, Sung Hee;Jin, Byungki;Kwon, Sanghyun;Yun, Myung Hwan
    • 대한인간공학회지
    • /
    • 제33권3호
    • /
    • pp.191-202
    • /
    • 2014
  • Objective: This study is conducted on the differences between flat and curved displays with respect to location of focused points, posture and satisfaction as well as preferred tilt angles. Background: In order to avoid physical and eye fatigue caused by misplayed sitting posture, many studies have asserted that the display requires appropriate location, size and tilt angle as well as curvature. However, most studies have focused on the work environment and the results are varied in the extent. Method: Eye height data in sitting posture were collected from 30 participants. Participants selected the most comfortable viewing angle within the range from $0^{\circ}$ to $12^{\circ}$ while watching videos for both curved and flat display. Then, physical and eye fatigue and overall satisfaction were subjectively evaluated. Lateral diagram describing viewing display condition was set and used to develop linear models for expecting the preferred tilt angle. Results: Due to sitting in the natural viewing posture rather than upright, the eye height is lowered to about 4.6 centimeters, on average, for both displays showing no significant differences. In contrast, preferred angles for the two displays are significantly different and this can be interpreted that curvature vary the points focused. Two linear models as functions of sitting eye height are developed to expect preferred tilt angle for each display. Based on the result of overall satisfaction evaluation, curved display is statistically better than flat display. Conclusion: The results show that flat and curved displays are significantly different expect for the viewing posture. However, reasons for preferring curved display are not accurately factorized and the linear models are limited in the experiment condition such as size of display, distance between display and viewer and other physical environmental factors. Further studies on curved displays under more various conditions are required. Application: This study can contribute to use of the curved display in various way.

An experimental study on the stern bottom pressure distribution of a high-speed planing vessel with and without interceptors

  • Seok, Woochan;Park, Sae Yong;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.691-698
    • /
    • 2020
  • In this study, the effects of hydrodynamic interceptors on a high-speed vessel were investigated to identify the operating principle based on experiments. Model tests were performed using a high-speed towing carriage. The resistance, trim and rise of Center of Gravity (CG) of the high-speed vessel were measured for various ship speeds and interceptor heights. As the interceptor height increased, the trim and rise of CG were reduced. In order to quantitatively analyze these phenomena, the pressure at the stern bottom was measured using tactile sensors. The reliability of the measured results from the tactile sensors was verified through repeat tests. The pressure on the stern bottom increased in proportion to the interceptor height, as the interceptor partially blocked the flow there. Then, the trim was reduced. However, as the ship speed increases, the pressure at the location close to the interceptor decreases when the interceptor height is small, leading to increased trim. Therefore, the interceptor height for running attitude control should be carefully determined considering multiple factors in the operating condition of the high-speed planing hull.

Cone beam형 전산화단층영상을 이용한 하악관의 전방고리 및 이공에 관한 연구 (Observation of the anterior loop and mental foramen of the mandibular canal using cone beam computed tomograph)

  • 고광준;김경아
    • Imaging Science in Dentistry
    • /
    • 제39권2호
    • /
    • pp.81-87
    • /
    • 2009
  • Purpose: To evaluate the anteroposterior length and buccal angle of the anterior loop, and the size and location of the mental foramen using cone beam computed tomography (CBCT). Materials and Methods: 100 CBCT images from 87 adults (43 males and 44 females) ranging in age from 20 to 73 years (average 50 years) with edentulous ridge of the mandibular premolar region were obtained. Axial, sagittal, coronal images were reconstructed from Dental and Block Images of CBCT. The anteroposterior length, shape and buccal angle of the anterior loop, and the size and location of the mental foramen were calculated from reconstructed images of axial, sagittal and coronal CBCT. Results: The anteroposterior length and buccal angle of the mental canal was 4.0${\pm}$1.2mm, 37.8${\pm}$11.60$^{\circ}$respectively. The loop type with straight course was the most common shape of the mental canal. The location of the mental foramen below the apex of the lower second premolar (78%) was the most common. The maximum size of the mental foramen was 4.6${\pm}$1.0 mm in width and 3.0${\pm}$0.6 mm in height. The inner size of the mental canal was 2.6${\pm}$0.6 mm in width and 2.1 mm${\pm}$0.4 mm in height. Conclusion: CBCT is useful to evaluate the anterior loop and mental foramen of the mandibular canal. Safe guideline of 4 mm from the most anterior point of the mental foramen is recommended for implant and surgical treatment. (Korean J Oral Maxillofac Radiol 2009; 39: 81-7)

  • PDF

Effect of Cage in Radiological Differences between Direct and Oblique Lateral Interbody Fusion Techniques

  • Ko, Myeong Jin;Park, Seung Won;Kim, Young Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.432-441
    • /
    • 2019
  • Objective : Few studies have reported direct comparative data of lumbar spine angles between direct lateral interbody fusion (DLIF) and oblique lateral interbody fusion (OLIF). The purpose of this study was to investigate the clinical and radiological outcomes of DLIF and OLIF, and determine influential factors. Methods : The same surgeon performed DLIF from May 2011 to August 2014 (n=201) and OLIF from September 2014 to September 2016 (n=142). Radiological parameters, cage height, cage angle (CA), cage width (CW), and cage location were assessed. We checked the cage location as the distance (mm) from the anterior margin of the disc space to the anterior metallic indicator of the cage in lateral images. Results : There were significant differences in intervertebral foramen height (FH; $22.0{\pm}2.4$ vs. $21.0{\pm}2.1mm$, p<0.001) and sagittal disc angle (SDA; $8.7{\pm}3.3$ vs. $11.3{\pm}3.2^{\circ}$, p<0.001) between the DLIF and OLIF groups at 7 days postoperatively. CA ($9.6{\pm}3.0$ vs. $8.1{\pm}2.9^{\circ}$, p<0.001) and CW ($21.2{\pm}1.6$ vs. $19.2{\pm}1.9mm$, p<0.001) were significantly larger in the OLIF group compared to the DLIF group. The cage location of the OLIF group was significantly more anterior than the DLIF group ($6.7{\pm}3.0$ vs. $9.1{\pm}3.6mm$, p<0.001). Cage subsidence at 1 year postoperatively was significantly worse in the DLIF group compared to the OLIF group ($1.0{\pm}1.5$ vs. $0.4{\pm}1.1mm$, p=0.001). Cage location was significantly correlated with postoperative FH (${\beta}=0.273$, p<0.001) and postoperative SDA (${\beta}=-0.358$, p<0.001). CA was significantly correlated with postoperative FH (${\beta}=-0.139$, p=0.044) and postoperative SDA (${\beta}=0.236$, p=0.001). Cage location (${\beta}=0.293$, p<0.001) and CW (${\beta}=-0.225$, p<0.001) were significantly correlated with cage subsidence. Conclusion : The cage location, CA, and CW seem to be important factors which result in the different-radiological outcomes between DLIF and OLIF.