• Title/Summary/Keyword: Height Difference

Search Result 3,026, Processing Time 0.037 seconds

Chracteristics of Somatotype for Boys of Elementary School Age I - In point of the Characteristics of Changing Somatotype in each period of Elementary School Age- (학령기 남아의 체형특성 I - 학령기별 체형변이특성을 중심으로-)

  • Yeo, Hye-Rin;Kwon, Young-Suk
    • Journal of the Korean Society of Costume
    • /
    • v.46
    • /
    • pp.31-48
    • /
    • 1999
  • The purpose of this study is to offer fundamental data for classification of somatotype for boys of elementary school age. The subject were 458 elementary school boys aged from 7 to 12 living in Pusan. Data were collected by 56 anthropometric 11 photoraphic measurements and 41 body indices. 56 anthropometric measurements were analyzed by ANOVA and method of Duncan-test as Multiple Range Test among 6 grade groups and then total 108 measurments were analyzed by statistical data processing. The results are as followings: 1, In Duncan-test boys were significantly different in most of height and length items but were not significantly different in main items for clothing construction among 1.2/3.4/5.6 grades so that the period of elementary school age were divided with 3 periods. 2. According to increase school age most of item's means increased gradually and personal difference for each items increased too. In case of height and length items the items of lower half were greater than the items of upper half in personal difference and depth items were greater than the breadth items in personal difference. And weight and angle items were very great personal difference is specially.

  • PDF

The Effect on the Lower Limbs Joint as the Landing Height and Floor Pattern (착지 높이와 지면 형태가 하지 관절에 미치는 영향)

  • Kim, Eun-Kyong
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.437-447
    • /
    • 2011
  • In this study, the lower limbs joints were analyzed for features based on the biomechanical characteristics of landing techniques according to height and landing on the ground type (flats and downhill). In order to achieve the objectives of the study, changes were analyzed in detail contents such as the height and form of the first landing on the ground at different angles of joints, torso and legs, torso and legs of the difference in the range of angular motion of the joint, the maximum angular difference between joints, the lower limbs joints difference between the maximum moment and the difference between COM changes. The subjects in this study do not last six months did not experience joint injuries 10 males in 20 aged were tested. Experimental tools to analyze were the recording and video equipment. Samsung's SCH-650A model camera was used six units, and the 2 GRF-based AMTI were used BP400800 model. 6-unit-camera synchronized with LED (photo cell) and Line Lock system were used. the output from the camera and the ground reaction force based on the data to synchronize A/D Syc. box was used. To calculate the coordinates of three-dimensional space, $1m{\times}3m{\times}2m$ (X, Y, Z axis) to the size of the control points attached to the framework of 36 markers were used, and 29 where the body was taken by attaching a marker to the surface. Two kinds of land condition, 40cm and 60cm in height, and ground conditions in the form of two kinds of flat and downhill slopes ($10^{\circ}$) of the landing operation was performed and each subject's 3 mean two-way RM ANOVA in SPSS 18.0 was used and this time, all the significant level was set at a=.05. Consequently, analyzing the landing technique as land form and land on the ground, the changes of external environmental factors, and the lower limbs joints' function in the evaluation were significantly different from the slopes. Landing of the slop plane were more load on the joints than landing of plane. Especially, knee extensor moment compared to the two kinds of landing, slopes plane were approximately two times higher than flat plane, and it was statistical significance. Most of all not so much range of motion and angular velocity of the shock to reduce stress was important. In the further research, front landing as well as various direction of motion of kinetic, kinetic factors and EMG variables on lower limbs joints of the study in terms of injury-prevention-approach is going to be needed.

The Effects of Landing Height on the Lower Extremity Injury Mechanism during a Counter Movement Jump (착지 후 점프 시 높이가 하지 관절의 변화와 부상기전에 미치는 영향)

  • Cho, Joon-Haeng
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • The purpose of this study was to determine the effects of landing height on the lower extremity during a counter movement jump. Fourteen healthy male subjects (age: $27.00{\pm}2.94$ yr, height: $179.07{\pm}5.03$ cm, weight: $78.79{\pm}6.70$ kg) participated in this study. Each subject randomly performed three single-leg jumps after s single-leg drop landing (counter movement jump) on a force platform from a 20 cm and 30 cm platform. Paired t-test (SPSS 18.0; SPSS Inc., Chicago, IL) was performed to determine the difference in kinematics and kinetics according to the height. All significance levels were set at p<.05. The results were as follows. First, ankle and knee joint angles in the sagittal plane increased in response to increasing landing height. Second, ankle and knee joint angles in the frontal plane increased in response to increasing landing height. Third, there were no significant differences in the moment of each segment in the sagittal plane for the jumping height increment. Fourth, ankle eversion moment and knee valgus moment decreased but hip abduction moment increased for the jumping height increment. Fifth, Ankle and knee joint powers increased. In percentage contribution, the ankle joint increased but the knee and hip joints decreased at a greater height. Lastly, as jumping height increased, the power generation at the ankle joint increased. Our findings indicate that the height increment affect on the landing mechanism the might augment loads at the ankle and knee joints.

A FINITE ELEMENT STRESS ANALYSIS OF FIXED PARTIAL DENTURE SUPPORTED BY OSSEOINTEGRATED IMPLANT AND THE NATURAL TEETH WITH REDUCED ALVEOLAR BONE HEIGHT (감소된 치조골 고경을 갖는 치아와 골유착성 임프랜트에 의해 지지되는 고정성 국소의치의 유한요소법적 응력분석)

  • Choi Choong-Kug;Kay Kee-Sung;Cho Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.296-326
    • /
    • 1994
  • The purpose of this study was to evaluate the mechanical effects when one implant fixture was connected to the natural teeth with reduced alveolar bone height. This study also examined the effects of increasing the number of abutment teeth and the effects of the intramobile connector and the titanium connector as they were inserted between the implant superstructure and the fixture. The distribution and concentration load was applied to the fixed partial denture(FPD) supported by implant and the natural teeth with reduced alveolar bone height. The stress and displacement of each element was observed and compared by the two-dimensional finite element method. The following results were obtained : 1. The greater the loss of alveolar bone in natural teeth area, the greater the displacement of FPD and the stress concentration in alveolar bone around implant, especially at the stress concentration in the mesial alveolar bone crest around implant fixture. 2. The displacement of FPD was increased more and that of implants fixture was decreased more when intramobile connector was used than titanium connector was used. Also the stress concentration in alveolar bone around implant fixture was greater when intramobile connector than titanium connector. One implication of this finding was that the difference in stiffness of implant and the natural teeth with reduced alveolar bone height could be partially compensated in case of the POM intramobile connector. 3. The amount and direction of displacement and the stress distribution of the 4-unit FPD was better than those of the 3-unit FPD. It implied that the difference of stiffness of implant and natural teeth with reduced alveolar bone height could be partially compensated in case of the 4 unit FPD.

  • PDF

A CEPHALOMETRIC EVALAUATION OF ANTERIOR OPENBITE MALOCCLUSIONS TREATED BY MULTILOOP EDGEWISE ARCHWIRE TECHNIQUE (Multiloop edgewise Archwire 기법으로 치료된 전치 개교 증례의 두부방사선사진 계측학적 평가)

  • Moon, Seong-Cheol;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.565-606
    • /
    • 1993
  • The purpose of this study was to evaluate the change of before and after treatment of anterior openbite malocclusions treated by Multiloop Edgewise Archwire technique. The openbite sample consisted of 4 male and 12 female adults, treated with nonextraction or third molar extraction. The normal sample consisted of 58 subjects, which have pleasing facial profile and normal occlusion and no experience of orthodontic or prosthodontic treatment. The 58 subjects of normal sample were subdivided by cephalemetric vertical relationship of face. The 40 subjects, cephalometric vertical relationship of face was in normal range, classified as Normal Sample group 1. The 18 subjects, increased cephalometric vertical relationship of face, classified as Normal Sample group 2. The computerized cephalometric analysis was accomplished with 50 reference points for 22 skeletal measurements, 46 dentoalveolar measurements, 8 soft tissue measurements. Statistical analysis of the data was carried out with paired t-test, Student's t-test, and DUNCAN test using SAS(PC version), The results were as follows : 1. There were no statistically significant differences in skeletal measurement between before and after treatment. The major changes were in dentoalveolar region. 2. After treatment, the long axis of maxillary and mandibular posterior teeth were distally tipped-back, and uprighted to bisected occlusal plane. The interincisal angle was increased. 3. There were no statistically significant increase in the upper posterior dental height and statistically significant decrease in the lower posterior dental height. The upper anterior dental height was increased, but there was no statistically significant increase in the absolute upper anterior dental hight. The lower anterior dental height was increased. 4. After treatment, the maxillary occlusal plane to palatal plane angle and the mandibular occlusal plane to mandibular plane angle were statistically significant increased. Then, there were no statistically significant difference between after treatment group and normal sample group 2. 5. After treatment, the percentage of upper lip length to upper anterior dental height was decreased. Then, There were no statistically significant difference between after treatment group and normal sample group 2.

  • PDF

Solder Region Detection and Height Calculation by the Characteristics and Phase Difference of the 3D Profiles in Moire Images (모아레 영상에서 3차원 형상정보의 특성과 위상차에 의한 솔더영역 검출 및 높이 계산)

  • Song, Jun Ho;Rhee, Eun Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5269-5279
    • /
    • 2014
  • The cause of defects in the PCB SMT assembly is mostly solder paste deposits. Conventional inspection methods for solder paste deposits suffer from slow speed, low reliability and high cost. Therefore, this paper proposes a method for calculating the height and region of solder paste on PCB using the 3D profiles without measuring the 2D image. The solder paste region is detected by the phase difference in the measurement points and the average phase on the whole surface of PCB. The high reliable height of the solder paste region is computed by the average of the measurement points' phase with repeatability and reliability. The experimental results revealed improvements of 17% in inspection time and 29% repeatability in the height calculation of the solder paste region, resulting in a high speed and less expensive system.

The Experimental Study on the Natural Ventilation Performance of Solar Chimney by the variation of Insulation Thickness and Height (단열재의 두께 및 연돌높이에 따른 태양열 굴뚝의 자연환기 성능에 관한 실험적 연구)

  • Cho, S.W.;Kim, D.W.;Im, Y.B.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.39-46
    • /
    • 2002
  • The results of experiment on the performance of natural ventilation by insulation thickness and height system of solar chimney are described. The 3-inside wall was made of concrete and 1-wall was made of glass. The two kinds of model experiment were performed. One was the varition of the 60cm, 90cm and 120cm of solar chimney, the other was the variation of the insulation thickness 10mm and 50mm and without insulation of outside wall of solar cimney. As the temperature difference between bottom and top expressed $1.7\sim2.9^{\circ}C$, air velocity measured $0.5\sim0.8m/s$ and ventilation rate was $194.4m^3/h$ in the case of the 120cm height of solar chimney, the respect of natural ventilation performance was superior to others cases in the first model experiment. Though the case of 120cm height of solar chimney was attached 50mm insulation the ventilation rate was not so much as the case of solar chimney was attached 10mm insulation. the temperature difference between bottom and top was the largest in the other cases. From this research, the natural ventilation performance of solar chimney was affected by not only height and insulation thickness of solar chimney but also wind velocity and directon.

A study on the improvement of seamless knitwear sleeve design (무봉제 니트웨어의 소매디자인 향상을 위한 연구)

  • Kang, Hee Myung;Ki, Hee-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.4
    • /
    • pp.57-71
    • /
    • 2021
  • The purpose of the study is to derive an appropriate knitting method that can increase the appearance, wearability, and functionality through empirical research on the sleeve height knitting ratio of seamless knit wear. The study was conducted by producing seven types of experiment clothes according to knitting ratio to examine the characteristics according to the body armhole and sleeve height ratio. Specifically, after fit evaluatins, variance analysis (ANOVA) was performed to analyze the results of the evaluation, and the evaluated contents were converted into data. Among them, the items with significant results were intensively studied using the Duncan-test. The result showed that the height and the width of the sleeves vary depending on the knitting ratio. Test sweater A was the highest at 16cm, followed by test sweater B, test sweater C, test sweater D, test sweater E, test sweater F, and test sweater G at 4cm. The 1:1 ratio of test sweater A, was the highest, which is knitted in the same course as the body. The larger the difference in the ratio of body and sleeve, the lower the height of the sleeves. As a result of the appearance sensory evaluation, a significant difference was confirmed in the result values (p<0.001) from all items on the front, side, and rear. Specifically, the appearance of the test sweater B(2:4:2) on the front and test sweater C(2:4:3) on the side and rear side was the best. When the sleeves height is properly set, the ratio of the arm line to fit the design with a natural curve is analyzed as a very important factor. The results of this study are expected to be of practical use in product development and production that can increase the feeling when wearing and design satisfaction.

Calculation of Precision Orthometric Height by Orthometric Correction (정사보정에 의한 정표고의 정밀계산)

  • 윤홍식;조재명
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.2
    • /
    • pp.117-125
    • /
    • 2004
  • This paper describes the orthometric correction for determining the orthometric height obtained from height difference by precise leveling or GPS leveling. Five formulas are used to calculate the orthometric correction for two level lines as an examples. Based on the comparison results Strang van Hees' formula that use the surface gravity is better than the others to compute the orthometric corrections on spirit leveling and GPS/Leveling in an area where mean hight is high and terrain relief show high variability. Further research is necessary to improve the results of this study using Mader method, etc..

The Comparison of Plantar Foot Pressure Distribution in Adult and Elderly according Obstacle Heights (장애물 높이에 따른 성인과 노인의 족저압 분포 비교)

  • Chang, Jong-Sung;Lee, Myoung-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.4
    • /
    • pp.257-261
    • /
    • 2014
  • Purpose: The purpose of this study was to compare plantar foot pressure distribution in adults and elderly according to obstacle height. Methods: Nine healthy adults and nine older adults were recruited and the subjects provided written informed consent consent prior to participation. Both groups walked and crossed obstacles with heights of 0%, 10%, 20%, and 30% of their height. Foot pressure was measured by peak pressure using the Pedar System (Novel Gmbh, Germany) during obstacle walking with barefeet in shoes. Three trails were calculated on eight areas and then averaged for data analysis. Results: A significant difference in great toe, little toes, and lateral metatarsal area was observed between adults and elderly groups, but other areas did not show significant differences. Foot pressure was increased in groups according to obstacle height. Conclusion: These findings showed that change in foot pressure distribution is more lateral in elderly in order to maintain postural control during obstacle crossing.