• Title/Summary/Keyword: Heavy water

Search Result 2,665, Processing Time 0.026 seconds

Antibiotic and Heavy Metal Resistance of Coliform Bacteria Isolated from Mineral Water (약수에서 分離한 大腸菌群의 일부 중금속 및 抗生劑耐性에 관한 연구)

  • Jeong, Jee-Yeon;Zong, Moon-Shik
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.1
    • /
    • pp.63-73
    • /
    • 1989
  • The purposes of this study were to find out the heavy metal and antibiotic resistant coliform bacteria from mineral water and the resistant factors. For the experiment, mineral water samples were taken from A area and B area during the period from march to July, 1988. The results of the experiment were as follows 1. From mineral water, eleven resistant coliforms and one susceptible coliform were isolated. 2. All resistant isolates harbored diverse plasmids of ranged ca. 14-54kb. 3. Susceptible coliform harbored a only plasmid of ca. 2.8 kb. 4. All resistant isolates harbored common size of plasmid of ca. 14kb. 5. As a result of the transformation and agarose gel electrophoresis experiments, resistant factor was R-plasmid. In conclusion, It is suggested that heavy metal contamination of mineral water is the selective pressure for the plasmid encoding the tolerance. Heavy metal resistance, in some case, is present with antibiotic resistance. Therefore, heavy metal contamination of mineral water induces antibiotic resistant bacteria.

  • PDF

The analysis of heavy metal total contents In milt of Han river (한강유역 저니층의 중금속 함량 전분석)

  • 정일현;김세진
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.63-71
    • /
    • 1994
  • An analytic and comparative study on the level of concentration on heavy metals in silt of Han- River was described. The Paldang lake supplies tap water resources for the 20 million residents in the metropolitan zone. It is composed that three steps for water works by the water volume in all 35,072 thousand tons : the first section is 7,251 thousand tons, the second is 15,980 thousand tons and the third is 11,841 thousand tons. However, recently it has becoming a serious social issue for water contamination on Paldang by heavy metals due to gathering of silt. It has concentrated on analysis and comparison study on the level of heavy metals between contamination- estimated zone and the other zones. After all, Concentration on heavy metals of expected none pollute's zone and expected pollute's zone indicate almost similar results. In the end, heavy metals within silt of Han- River consider not to effect on pollution but quantity of natural condition.

  • PDF

Water utilities vulnerability assessment and adaption strategies for climate change in Jeju province (제주도 기후변화 관련 상수도시설 취약성 평가 및 적응대책)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.517-526
    • /
    • 2018
  • Climate adaptation strategies for water utilities including 16 water treatment plants(WTPs) in Jeju were investigated. Drought, heat wave, and heavy rain were among the most significant climate factors affecting water utilities in Jeju. Heat wave increases water temperature, which in turn increases the concentration of algae, color, and odor materials. Some adaption strategies for the heat wave can be strengthening water monitoring and introducing advanced water treatments. Heavy rain increases raw water turbidity in surface water. The 7 WTPs that take raw water from streams or springs had a maximum turbidity of less than 50 NTU under heavy rain. However, due to concerns of turbidity spike in treated water, some WTPs discontinued intaking raw water when raw water turbidity increased more than 2 NTU. They instead received treated water from other WTPs which took groundwater for water supply. This happens because of the low skills of employees. Thus, there needs to be an increase in operator competency and upgrade of water facilities for the adaption of heavy rain. To improve adaption for the drought, there should be an increase in the capacity of intake facilities of surface water as well as a decrease in water loss. In addition, water consumption per person should be decreased.

Effects of Heavy Metals on the Beware Treatment Process by Water Hyacinth (중금속이 수생히야신스(부레옥잠)를 이용한 하수처리 공정에 미치는 영향)

  • 정재욱;유홍일;유재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.110-119
    • /
    • 1994
  • The objective of the this study was to evaluate the effects of heavy metals on the sewage treatment process designed to remove organic material and nutrients using Water- hyacinth ( Eichhornia crassipes ). Batch experiments were carried out using domestic sewage spiked with different level of heavy metal mixtures ( Cd, Pb and Cu ). The specific growth rates of Water- hyacinth ranged from 0.0008 to 0.0015 1/day( operated at water temperatures of 22 ∼30$\circ $c ) and increased as the concentration of heavy metals decreased. The test result showed that the permissible maximum concentrations Cd, Pb and Cu for the growth of Water- hyacinth were 0.5, 1, and 6 mg/ℓ respectively. Under these maximum permissible heavy metal loads, removal rate of organic material, nitrogen and phosphorus were 85%,75% and 75% , respectively, during 40days of the test period.

  • PDF

Preparation and characterization of green adsorbent from waste glass and its application for the removal of heavy metals from well water

  • Rashed, M. Nageeb;Gad, A.A.;AbdEldaiem, A.M.
    • Advances in environmental research
    • /
    • v.7 no.1
    • /
    • pp.53-71
    • /
    • 2018
  • Waste glass disposal causes environmental problems in the cities. To find a suitable green environmental solution for this problem low cost adsorbent in this study was prepared from waste glass. An effective new green adsorbent was synthesized by hydrothermal treatment of waste glass (WG), followed by acidic activation of its surface by HCl (WGP). The prepared adsorbent was characterized by scanning electron microscopy (SEM), X-ray fluorescence (XRF), X-ray diffraction (XRD), and BET surface measurement. The developed adsorbent was used for the removal of heavy metals (Cd, Cu, Fe, Pb and Zn) from well water. Batch experiments were conducted to test the ability of the prepared adsorbent for the removal of Cd, Cu, Fe, Pb and Zn from well water. The experiments of the heavy metals adsorption by adsorbent (WGP) were performed at different metal ion concentrations, solution pH, adsorbent dosage and contact time. The Langmuir and Freundlich adsorption isotherms and kinetic models were used to verify the adsorption performance. The results indicated high removal efficiencies (99-100%) for all the studied heavy metals at pH 7 at constant contact time of 2 h. The data obtained from adsorption isotherms of metal ions at different time fitted well to linear form of the Langmuir sorption equation, and pseudo-second-order kinetic model. Application of the resulted conditions on well water demonstrated that the modified waste glass adsorbent successfully adsorbed heavy metals (Cd, Cu, Fe, Pb and Zn) from well water.

Combustion Characteristics of Heavy Fuel Oil-water Emulsion

  • Kim Houng-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.88-92
    • /
    • 2006
  • This study is intended to check the flame temperature to raise in burning grade C heavy fuel oil and emulsion fuel oil in a boiler and to measure the concentration of Dry Shoot(DS) and Soluble Organic Fraction(SOF) after collecting the Particulate Matters (PM). The flames temperature in boiler was measured by burning grade C heavy oil and oil-water emulsion (C heavy oil $70\%\;and\;30\%$ of water) Combustion characteristics of two fuels was also compared by trapping particulate matters (PM) in exhaust gas and measuring the generated quantities of DS and SOF in fuel gas.

Long-Term Change of Heavy Metal Concentration in the Kumho River Water (금호강 수 중의 중금속류의 장기변도)

  • 배준웅;이상학;이성호
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • In order to study the long-term change of heavy metal concentrations in the Kumho river water, water analysis was conducted at 13sites surrounding the Kumho river system for 18times from September 1993 to August 1999. Analytical items for the study of water quality are Cu, Zn, Cd, Cr, Fe, Mn and Pb. The six year term studied in this work was divided into Part I and Part II, which covers the period from September 1993 to August 1996 and the period from September 1996 to August 1999, respectively. The mean concentrations of Cu, Zn, Cd, Cr, Fe, Mn and Pb in the unit of ppm for the Part I period showed 0.032, 0.025, 0.006, 0.050, 0.053 and 0.019, respectively. The mean concentrations of Cu, Zn, Cd, Cr, Fe, Mn and Pb in the unit of ppm for the Part II period showed 0.001, 0.001, 0.001, 0.004, 0.020, 0.002 and 0.002, respectively. The heavy metal concentrations in the Kumho river water for te second period were found to be decreased by 1/32, 1/25, 1/6, 1/1.5, 1/2.5, 1/26.5 and 1/9.5 for Cu, Zn, Cd, Cr, Fe, Mn and Pb, respectively. The present results clearly indicate that the water quality in the Kumho river is improving in terms of heavy metal contaminations.

  • PDF

Adsorption Characteristics of Heavy Metals for Waste Sludge and Oyster Shell (폐슬러지와 폐굴껍질의 중금속 흡착특성)

  • Jeon, Dae-Young;Lee, Kyung-Sim;Shin, Hyun-Moo;Oh, Kwang-Joong
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1053-1059
    • /
    • 2006
  • This study was performed to investigate the possible uses of waste sludge for the removal of heavy metal ions. The adsorption experiments were conducted with wastes such as sewage treatment sludge, water treatment sludge and oyster shell to evaluate their sorption characteristics. Heavy metals selected were cadmium, copper and lead. in the sorption experiments on the sewage treatment sludge, water treatment sludge, oyster shell and soil, sorption occurred in the beginning and it reached equilibrium after 40 minutes on the oyster shell and 4 hour on the sewage treatment sludge and water treatment sludge. Results of Freundlich isotherms indicated that sewage treatment sludge could be properly used as an adsorbent for heavy metals and sorption strength of heavy metals was in the order of Pb > Cu > Cd. In the influence of pH on the adsorbents, sorption rate was more than 80% in pH 4 and most of heavy metals were adsorbed in pH 9. Adsorption rate of Cd decreased with decreasing pH and then adsorption rate of Cu was lower in soil.

A Leaching Characteristics on Lime Stabilization of Heavy Metal Contaminated Soil in a Waste Mine Area (폐 광산 지역 중금속 오염 토양의 석회안정화 적용 시 용출특성)

  • Oa, Seong-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.862-867
    • /
    • 2011
  • Pozzolanic-based stabilization/solidification (S/S) is an effective and economic remediation technology to immobilize heavy metals in contaminated soils. In this study, quick lime (CaO) was used to immobilize cadmium and zinc present in waste mine contaminated clayey sand soils. Addition of 5% quicklime to the contaminated soils effectively reduced heavy metal leachability after 2 bed volume operation below the drinking water regulatory limits. Lime addition was revealed to increase the immobilization for all heavy metals in tested pH ranges, so it could be an optimal choice for short-term remediation of heavy metal contaminated soil. The mass balances for these column tests show metal reduction of 92% for Cd and 87% for Zn of total resolved mass in case of 5% lime application.

Study of the used deuterium absorption material disposal

  • Kim, Dong-Gyung;Kim, Myung-Chul;Lee, Bum-Sig;Lee, Sang-Gu
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.64-72
    • /
    • 2004
  • The dryer (ten per unit) are operating to remove tritium in PHWR(Pressurized Heavy Water Reactor). There are coming out heavy water adsorbent from operating the dryer (95 drums for ten year per unit) The amount of radioactivity of heavy water adsorbent almost exceed ninety times more than disposal limit-in-itself showed by The Ministry of Science and Technology. It has to be disposed whole radioactive waste products, however there are problems of increase at the expense of their permanent disposal. In this research, We have studied how to remove kinds of nuclear materials and amount of tritium with in heavy water adsorbent. As the result we could develop disposal equipment and apply it. D20 adsorbent have to contain below Gamma nuclide O.3Bq/g and tritium 100Bq/g "The Regulation for disposal of the radioactivity wastes" showed by The Ministry of Science and Technology. There fore. So as to remove amount of tritium and kinds of nuclear materials (DTO) we needed a equipment. Also we have studied how to remove effectively radioactivity with in Adsorbent. As cleaning heavy water adsorbent and drying on each condition (temperature for drying and hours for cleaning). Because there is something to return heavy water adsorbent by removing impurities within adsorbent when it is dried o high temperature. After operating, we have been applying this research to the way to dispose heavy water adsorbent. Through this we could reduce solid waste products and the expense of permanent disposal of radioactive waste products and also we could contribute nuclear power plant run safely. According to the result we could keep the best condition of radiation safety super vision and we could help people believe in safety with Radioactivity wastes control for harmony with Environment.

  • PDF