• Title/Summary/Keyword: Heating velocity

Search Result 360, Processing Time 0.024 seconds

Thermomechanical Properties of Thermal-Stress Relief Type of Functionally Gradient Materials

  • Watanabe, Ryuzo
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 1993년도 추계학술강연 및 발표대회강연 및 발표논문 초록집
    • /
    • pp.2-2
    • /
    • 1993
  • The present status of the thennomechanica1 evaluation of functionally gradient materials(FGMs) for space plane application was reviewed, in which research activities and the cooperation of the national project team organized to study FGM science were demonstrated. The project team was divided into three working groups; de singing, processing and evaluation, each of which had their own tasks in the project cooperation. The testings details of the various thennomechanical tests for the FGM samples fabricated by the processing groups were described, along with their corresponding heating conditions of the real environments in the space plane application. For small-sized samples, laser beam heating test and burner heating test were well applied to study the heat shielding and heat resisting properties. Arc-heated wind tunnel test and high temperature!high velocity gas flow test were used for large-sized panel assemblies having cooling structures. The criteria for the evaluation of the heat shielding and heat resisting properties of the FGMs, as well as a crack activation mechanism in their differential temperature heating, were proposed on the basis of the observation in the burner heating test.

  • PDF

대류난방시 실내열환경에 관한 연구 - 온도 및 기류속도에 대한 온열쾌적감- (The Study on Indoor Thermal Environment during Convection Heating - Thermal Comfort by Indoor Air Temperature and Velocity -)

  • 김동규;정용현
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.209-214
    • /
    • 2005
  • Draft is defined as an unwanted local cooling of the human body caused by air movement. It is a serious problem in many ventilated or air conditioned buildings. Often draft complaints occur although measured velocities in the occupied zone maybe lower than prescribed in existing standards. Purpose of this study is to clarify the evaluation of thermal comfort based on temperature and air velocity in winter. Experiments were performed in an environmental chamber in winter. Indoor temperature and air velocity was artificially controlled. The experiments were performed to evaluate temperature conditions and air velocity conditions by physiological and psychological responses of human. According to physiological responses and psychological responses, it was clear that the optimum air velocity is about 0.15 m/s and 0.30 m/s.

암석의 물리적 특성 변화에 대한 온도의 영향 (A Study on Effects of Temperature for Physical Properties Change of rocks)

  • 김재환;이명성;이미혜;이재만;박성미
    • 암석학회지
    • /
    • 제20권3호
    • /
    • pp.141-149
    • /
    • 2011
  • 암석의 물리적 특성 변화에 대해 온도의 영향을 연구하기 위해 2종의 화강암류와 대리암, 사암을 전기로에서 $400^{\circ}C$$600^{\circ}C$로 가열하였다. 모든 시료에서 가열 후 물리적 특성(비중, 공극률, 흡수율, 초음파속도)과 색상 변화는 보이나, 편광현미경을 이용한 광물학적 변화는 뚜렷하지 않다. 특히 물리적 특성 변화에서 공극률과 흡수율은 증가하고, 비중과 초음파 속도는 감소하는 경향을 보이며, 온도가 증가할수록 변화폭은 크게 나타난다. 여기서 측정한 공극률은 암석의 전체 공극률을 반영하지 못하고 있으나 온도에 의한 암석의 표면 상태 변화를 반영한다 반면 초음파 속도는 암석의 전체적인 손상 정도를 파악하는데 유용하다. 그러므로 온도에 의한 암석의 물리적 특성 변화를 설명하기 위해 공극률과 초음파 속도는 상호 비교해야 한다.

측벽 부하가 존재하는 공간에 설치된 라인 디퓨져의 ADPI 특성에 관한 연구 (ADPI Characteristics of Line Diffuser in a Room with Perimetric Heating Load)

  • 조영진;강석윤;문종선;이재헌
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1204-1211
    • /
    • 2004
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the air diffusion performance index (ADPI) vs. throw/length (T/L) ratio curve listed in conventional guide does not consider the perimetric heating load through the walls. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and propose a selection guide for a proper line diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI values are obtained numerically with various heat load ratios and air flow rates. The velocity and temperature distributions and the ADPI values are analyzed by CFD in case of various heat load ratios and air flow rates. Also, ADPI was calculated by those results. The ADPI values by numerical results are compared with an existing experimental data to verify the method for the evaluation of ADPI proposed in a present study. In case of a line diffuser installed at the high side wall, the ADPI decreases according to the increases of the flow rate on every heat load ratio of the present study except 0.75. The ADPI vs. T/L ratio curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee the comport thermal environment when diffusers are installed in perimeter zone.

일반류가 수평대류에 미치는 영향에 관한 수치연구 (A Numerical Study of a Effect of the Uniform Flow in Horizontal Convection)

  • 이화운;김유근;정우식
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.349-360
    • /
    • 1998
  • Effects of uniform flow on a two-dimensional mesoscale horizontal convection were investigated by using the vorticity and thermodynamic equations. For thins purpose, We simulated properties of a thermal convection m a stably stratified Boussinesq flued caused by partial heating at the center of a lower boundary If we don't consider effects of the uniform flow, the convection takes the form of aidsymmetrlc with respect to the z-alds. But when uniform flow Is strong, velocity field and temperature field consist of a sin91e cell structure which spreads upstream side of the partial heating area. The flow pattern for strong uniform flows takes the form of positive temperatue near the ground and negative temperature perturbation soft over the partial heating area, and downward motion directly over the upwind portion of the partial heating area and upward motion on the downstream side. The downstream edge of the upstream cell Is shifted in the downstream direction with the Increase of uniform flow almost linearly.

  • PDF

열매체유 유동층 열교환기의 전열성능에 대한 실험적 연구 (An Experimental Study on Heat Transfer Performance of Heating Medium Oil Fluidized Bed Heat Exchanger)

  • 박상일;고창복;이영수
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.146-151
    • /
    • 2015
  • The heat transfer performance of heating medium oil fluidized bed heat exchanger was measured. The operation variables were air flow rate, air inlet temperature, moisture content, water flow rate and water inlet temperature. The outside heat transfer coefficient was determined from the heat exchanger experiment and its experimental correlation was determined as a function of air velocity and viscosity of heating medium oil. Effect of viscosity was well agreed with the previous studies. Errors of the correlation equation was less than about 10% for outside heat transfer coefficient developed in this study when compared with the measured value. Hot water with the temperature greater than $77^{\circ}C$ could be produced by using the heating medium oil fluidized bed heat exchanger.

저속치환 공조시스템의 특성에 대한 연구 (On the Characteristics of the Low Velocity Displacement Air-Conditioning System)

  • 이계철;김동규;김경구;권영필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.493-498
    • /
    • 2001
  • In the low velocity displacement air-conditioning system, the conditioned air is supplied from the diffuser placed on the wall near the floor and vented near the ceiling. This system has some advantages upon the traditional mixing system; the air quality near the people is improved by the displacing action of the system and the energy may be saved by neglecting the cooling or heating load for the upper space of the space above the people. This study is to examine the temperature and velocity distributions in the room and near the diffuser. It is found that the temperature is stratified uniformly all over the room space to show the displacing function of the system.

  • PDF

비소성 황토를 치환한 고강도 콘크리트의 고온 역학적 특성 평가를 위한 초음파 속도 분석 (Ultrasonic pulse velocity analysis for high- temperature mechanical properties of high strength concrete replacing non-sintered hwangto )

  • 김태형;김원창;이태규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.273-274
    • /
    • 2023
  • In this study, ultrasonic pulse velocity was analyzed to evaluate the high-temperature mechanical properties of concrete mixed with non-sintered hwangto. The W/B of the specimens was set at 0.41, the percentage of non-sintered hwangto admixture was set at two levels of 15,30%. The target temperature of the specimen is set to 6 levels of 20, 100, 200, 300, 500, 700 ℃, and the heating rate is set to 1℃/min. The result showed that the amount of non-sintered hwangto incorporated into the concrete tends to results in lower compressive strength. Ultrasonic pulse velocity showed similar trends, but differed in some areas.

  • PDF

전자빔 가열로 발생시킨 Gd 원자증기의 속도에 관한 연구 (Study on the velocity of gadolinium atomic vapor produced by electron beam heating)

  • 정의창;권덕희;고광훈;김택수
    • 한국진공학회지
    • /
    • 제12권4호
    • /
    • pp.228-234
    • /
    • 2003
  • 전자빔으로 증발시킨 gadolinium(Gd) 원자증기의 속도를 미량 저울(microbalance)을 사용하여 측정하였다. 증발 표면의 온도가 2400-2500 K인 조건에서 약 900 ㎧의 속도가 측정되었다. 이 값은 단열팽창을 하는 이상적 단원자의 최대 속도에 비해 약 100 ㎧ 더 빠른 속도에 해당된다. 이 특이 현상의 원인을 고온에서 여러 개의 들뜬 에너지 준위에 분포한 Gd 원자의 내부 에너지가 단열팽창 중에 운동 에너지로 전환되는 것으로 설명하였다. 100개의 들뜬 에너지 준위를 원자증기의 엔탈피에 포함시켜 속도를 계산한 값이 실험 결과와 비교적 일치함을 보였다. 가열된 표면 온도의 변화에 따른 원자증기의 유동 특성에 대해서도 보고한다.

Variations in the hysteretic behavior of LRBs as a function of applied loading

  • Ozdemir, Gokhan;Bayhan, Beyhan;Gulkan, Polat
    • Structural Engineering and Mechanics
    • /
    • 제67권1호
    • /
    • pp.69-78
    • /
    • 2018
  • The study presented herein focused on the change in hysteretic force-deformation behavior of lead rubber bearings (LRBs). The material model used to idealize response of LRBs under cyclic motion is capable of representing the gradual attrition in strength of isolator unit on account of lead core heating. To identify the effect of loading history on the hysteretic response of LRBs, a typical isolator unit is subjected to cyclic motions with different velocity, amplitude and number of cycles. Furthermore, performance of an LRB isolated single degree of freedom system is studied under different seismic input levels. Finally, the significance of lead core heating effect on LRBs is discussed by considering the current design approach for base isolated structures. Results of this study show that the response of an LRB is governed strongly by the amplitude and number of cycles of the motion and the considered seismicity level.