• 제목/요약/키워드: Heating tool

검색결과 190건 처리시간 0.012초

전기아연도금용 강판의 상온 탈지 조건 연구 (Study on the Room Temperature Degreasing Conditions of Steel Sheet for Electrogalvanizing)

  • 박태연;김채원;양수미;홍희준;최인철
    • 열처리공학회지
    • /
    • 제37권1호
    • /
    • pp.16-22
    • /
    • 2024
  • The conventional degreasing process involves removing oil and contaminants at temperatures above 80℃, resulting in excessive energy consumption, increased process costs, and environmental issues. In this study, we aimed to find the optimal degreasing conditions for the pre-treatment process of electro-galvanizing cold-rolled steel sheets, conducted efficiently at room temperature without the need for a separate heating device. To achieve this, we developed a room temperature degreasing solution and a brush-type degreasing tool, aiming to reduce energy consumption and normalize the decrease in degreasing efficiency caused by temperature reduction. Alkaline degreasing solution were prepared using KOH, SiO2, NaOH, Na2CO3, and Sodium Lauryl Sulfate, with KOH and NaOH as the main components. To enhance the degreasing performance at room temperature, we manufactured additives including sodium oleate, sodium stearate, sodium palmitate, sodium lauryl sulfate, ammonium lauryl sulfate, silicone emulsion, and EDTA-Na. Room temperature additives were added to the alkaline degreasing solution in quantities ranging from 0.1 to 20 wt.%, and the uniformity of degreasing and the adhesion of the galvanized layer were evaluated through Dyne Test, T-bending Test, OM, SEM, and EDS analyses. The results indicated that the optimal degreasing solution composition consisted of NaOH (30 g/L), Na2CO3 (30 g/L), SLS (6 g/L), and room temperature additives (≤1 wt%).

현장실사를 통한 급식유헝별 위생관리실태 분석 (Analysis of Critical Control Points through Field Assessment of Sanitation Management Practices in Foodservice Establishments)

  • 곽동경;이경미;장혜자;강영재;홍완수;문혜경
    • 한국식품조리과학회지
    • /
    • 제21권3호
    • /
    • pp.290-300
    • /
    • 2005
  • 본 연구에서는 우리나라 집단급식소를 HACCP 지정유무 및 급식 유형별로 분류하여 위생관리 실태를 평가하여 유형별 문제점을 파악하고 개선방안을 제시하였다. 평가내용은 총 105개 항목, 9개의 영역으로 개인위생, 식재료의 공급, 식품의 저장, 생식품과 조리된 식품의 분리취급, 배식, 세척과 소독, 쓰레기처리, 방충$\cdot$구서 대책, 시설$\cdot$설비 관리영역으로 구성되어 있다. 조사대상급식소는 급식유형에 따라 발생되는 문제점을 고려하기 위해 중$\cdot$고등학교급식소, 대학교급식소, 사업체급식소를 대상으로 이루어졌다. 본 연구의 결과를 하면 다음과 같다. 1. 서울, 경기, 경남지역의 집단급식소 20개소를 대상으로 이루어졌다. 중$\cdot$고등학교급식소 7곳과 대학교 급식소 4곳, 사업체 급식소 9곳을 대상으로 하였다. HACCP 지정급식소는 6곳으로 중 고등학교가 3곳, 사업체 3곳을 포함한다. 평균 중식수는 약 1,400식 정도의 규모이며, 평균 근무인원은 약 34명 정도로 나타났다. 조리원 1인당 맡고 있는 식수는 평균 103식 정도로 양호한 작업량을 보였다. 2. 전체 평균점수는 105점 만점에 72.3점을 보였고 평균 43.9항목$(65.5\%)$이 준수되었고 18.9항목$(30.0\%)$이 비준수로 집계되었다. HACCP 지정업체와 비지정업체간의 비교에서는 HACCP 지정업체가 모든 영역에서 비지정업체에 비해 위생관리가 잘 이루어지고 있었으며 특히 시설$\cdot$설비영역에서 많은 차이를 보였다. 3. 급식유형별 비교에서는 중$\cdot$고등학교급식소가 다른 급식유형에 비해 많은 영역이 잘 이루어지고 있었다. 특히 방충$\cdot$구서대책이나 세척과 소독, 생식품$\cdot$조리식품의 분리취급에서 위생적으로 관리되고 있었다. 반면 대학교 급식소는 위생관리가 제대로 수행되지 않는 유형으로 시급히 보완되어야 하겠다. 특히 대학교 급식소는 방충$\cdot$구서 대책, 쓰레기처리, 시설$\cdot$설비영역, 식재료영역의 이행 수준이 낮게 나타났다. 이상의 결과에서 급식소의 위생관리를 철저히 수행하기 위해서는 본 연구에서 사용된 위생관리 모니터링 도구를 이용하여 정기적으로 평가하는 동시에 그 결과를 종업원에게 알려주고, 교육$\cdot$훈련에 적극 활용하는 것이 필요하다. 집단급식소의 경우 인력의 유동이 심하고 시간제 조리원이 많아 교육의 효과를 보기 어려운 경우가 많지만 지속적인 교육과 조직문화 창달을 통해서 그 효과를 배가 시켜야 하겠다. 또한 식당 홀뿐 아니라 주방내의 작업환경의 개선을 통해서 좀 더 효율적으로 위생관리 될 수 있는 급식 시스템의 구축도 필요하겠다. 식중독예방을 위한 방안으로 본 연구에 사용된 것과 같은 체계적인 모니터링 도구를 활용한 지속적인 자가 진단과 개선 및 시정이 철저하게 이루어져야 할 것이다. 본 연구의 제한점은 훈련된 연구원이 직접 현장 점검하는 방법을 채택하여 경제적, 시간적 한계로 인해 샘플수가 적었다. 그러므로 우리나라 집단급식소의 수에 비해 적은 수의 급식소를 대상으로 하여 대표성이 다소 결여되었다. 따라서 우리나라 집단급식소의 위생관리 실태를 완전하게 파악하기 위해서는 더 많은 연구자들이 급식소의 위생관리 실태조사에 참여하고, 이를 데이터베이스화하여 객관적으로 평가하는 작업이 필요할 것으로 사료된다

폴리아미드 66 복합소재의 열 열화 특성: 수명 예측과 활성화 에너지의 상관관계 (Characterization of Thermal Degradation of Polymide 66 Composite: Relationship between Lifetime Prediction and Activation Energy)

  • 정원영;원종일
    • 폴리머
    • /
    • 제36권6호
    • /
    • pp.712-720
    • /
    • 2012
  • 광학현미경분석, 주사전자현미경분석 및 적외선분광분석을 이용하여, 열화시간 경과에 따른 유리섬유가 보강된 폴리아미드 66 복합소재의 열 열화 특성을 조사하였다. 열화시간이 증가함에 따라, 인장강도는 열화 초기 약간의 증가 후 점진적으로 감소하는 경향을 보였다. 이러한 결과는 열 열화가 진행됨에 따라 결정화도의 증가, 가교밀도의 증가, 사슬 전단 및 사슬 운동성의 감소 등에 기인한 것으로 판단된다. 적외선분광분석을 통하여, 폴리아미드 66 복합소재 표면상에 열화에 기인한 케톤 피크와 규소 피크의 증가를 관찰하엿다. 또한 세 가지 승온속에서 측정된 열중량분석 결과를 이용하여 폴리아미드 66 복합소재으 열 분해 반응동역학을 분석하였다. 통계학적 기법, UL 746B, Ozawa 및 Kissinger 등 여러 방법을 통해 계산된, 폴리아미드 66 복합소재의 활성화 에너지와 수명 예측간의 상관관계를 조사하였다. 열중량분석으로부터 계산된 활성화 에너지는 가속시험으로 구한 값보다 상대적으로 큰 값을 나타내며, 이는 폴리아미드 66 소재으 수명을 과대 평가하는 결과를 초래하였다. 본 연구에서는 다양한 사용 온도에서의 활성화 에너지를 외삽하여 계산 가능한 지수 패턴의 표준곡선을 개발하였다.

확률론적 해석에 기반한 다중 열저장공동의 적정 이격거리 분석 (Analysis of the Optimal Separation Distance between Multiple Thermal Energy Storage (TES) Caverns Based on Probabilistic Analysis)

  • 박도현;김현우;박정욱;박의섭;선우춘
    • 터널과지하공간
    • /
    • 제24권2호
    • /
    • pp.155-165
    • /
    • 2014
  • 다중 열저장공동은 열에너지의 대규모 저장, 열적 성능 향상을 위한 높은 종횡비의 저장소 설계에 활용될 수 있다. 또한 긴 터널형의 단일공동이 열생산 및 주입을 위한 지상설비와의 연결에 적합하지 않은 경우, 길이를 줄인 다중 암반공동의 활용을 고려할 필요가 있다. 다중 열저장공동 활용시 공동간의 이격거리는 저장공간 설계시 고려해야 하는 주요 설계인자 중 하나이며, 정량적인 안정성 평가기준을 토대로 적정 이격거리가 산정되어야 한다. 본 논문에서는 대규모 열에너지 저장을 위한 다중 암반공동 계획시 공동간 이격거리를 결정하기 위한 수치 해석적 접근법에 대해 기술하였다. 다중 암반공동의 안정성 평가를 위해 기존의 결정론적 접근법과 달리 확률밀도에 의해 입력 매개변수의 불확실성을 정량적으로 고려할 수 있는 확률론적 해석기법을 이용하였으며, 집단열수 공급을 위한 다중 암반공동의 개념모델 설계에 적용하였다. 본 적용을 통해 확률론적 해석기법이 다중 암반공동의 이격거리 산정을 위한 의사결정 도구로서 유용하게 활용될 수 있음을 확인할 수 있었으며, 결정론적 해석결과와의 비교 분석으로부터 결정론적 접근법 적용시 안정성 평가기준을 신중히 설정할 필요가 있는 것으로 검토되었다.

비연소식(非燃燒式) 구법(灸法) 재료(材料)를 이용한 온열자극(溫熱刺戟)이 체열방사(體熱放射)에 미치는 효과 (Effects of Non-combustible moxibustion on Thermography of Healthy Human Beings)

  • 최원종;김재효;김경식;손인철
    • Korean Journal of Acupuncture
    • /
    • 제21권3호
    • /
    • pp.21-38
    • /
    • 2004
  • Objectives : Moxibustion has been become very useful tool to prevent and treat various diseases with acupuncture in oriental medicine. Expecially, moxibustion combining the heat stimulation and chemical stimulation of Artemisiae Argyi has a non-invasive characteristics comparing to the other therapeutic tools. However, because the moxibustion makes the patient's skin be burn by the combustible feature of moxibustion, most of people have been scared of being scald. Methods : In this study, we have developed new non-combustible moxibustion tools in collaboration with company (Hana Medical, co. and ICURE, co.) and tested the efficacy through effects of moxibustion of Cheon-chu $(ST_{25})$ on the abdominal thermography of health subject. The non-combustible moxibustion has main characteristics of controlled heating to inhibit being scald and heat stimulation lasting over 1 hrs. Also, to induce the chemical stimulation, the bottom contacting with skin was coated by the extract of artemisiae argyi. The volunteers who participating in this study had taken rest for 20 - 30 mins in room temperature $(23-25^{\circ}C)$ before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day The thermography of abdomen including a below part of the chest was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes. Results : The results showed that moxibustion of Cheon-chu $(ST_{25})$ had more potencies of changes on all the ROIs of abdominal thermography than those of control group. Also, it was observed that the quantities of thermal changes following moxibustion of Cheon-chu $(ST_{25})$ been increased significantly comparing that of control group at all the ROIs (region of interest). Observed the thermography classified by ROI, however, moxibustion of Cheon-chu $(ST_{25})$ could modulate ipsilateral specific areas concerning to the abdominal pathway of Stomach Meridian. Conclusion : These results suggest that new non-combustible moxibusion has some similarity as like as the conventional moxibustion and moxibustion of Cheon-chu $(ST_{25})$ may modulate thermal changes of abdominal areas.

  • PDF

지하공간통합지도 기반 3차원 지하정보 구축 및 가시화시스템 개발 (Development of 3D Underground Information Construction and Visualization System Based on IUGIM)

  • 강경남;김우람;황승현;안준상
    • 한국측량학회지
    • /
    • 제39권6호
    • /
    • pp.497-505
    • /
    • 2021
  • 최근 국내에서 빈번하게 발생하는 지하공간 사고에 기인하여 정부에서는 지하공간 안전관리 대책으로 지하공간통합지도(IUGIM: Integrated Underground Geospatial Information Map) 구축의 기본 계획을 2015년에 수립하여 2021년 현재 부분 구축이 완료된 상태이고, 지하공간 관리 주체 및 관계 기관 등이 활용 중이다. 본 연구는 지하공간통합지도의 활용성 향상 방안의 일환으로 수행 중이며, 현장에서 계측된 실시간 기반의 데이터와 지하공간통합지도 내에 저장되어 운용 중인 보관 데이터의 비교 작업을 수행하기 위한 가시화시스템을 구축하는 내용을 다룬다. 지하공간통합지도에 구축되어 관리되고 있는 시추공 데이터 및 지하시설물 6종에 대한 가시화 기능을 탑재한 시스템을 구축하였다. 지하시설물 6종은 상수도관, 하수도관, 전력관, 가스관, 통신관 및 난방관이다. 구축 완료된 시스템은 서울시 강남구, 서초구 일원 3지점에 대한 현장 실증을 수행하였다. 현장 실증은 모바일센터에 접속해서 지하공간통합지도 데이터 내려받기, 지하공간통합지도 데이터(지표면 생성, 시추정보, 지하시설물) 가시화 작업, 현장에서 취득한 GPR(Ground Penetrating Radar) 기반 데이터에 대한 가시화 등으로 진행하였다. 지하공간통합지도 데이터 및 GPR 기반 현장 데이터의 실증 결과 적합한 것으로 판정되었다. 본 연구의 결과로 굴착 현장에서 안전한 시공에 도움이 될 수 있을 것으로 판단된다.

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

최근의 봄꽃 개화 추이와 2014년 개화시기의 혼란 (Recent Trends in Blooming Dates of Spring Flowers and the Observed Disturbance in 2014)

  • 이호승;김진희;윤진일
    • 한국농림기상학회지
    • /
    • 제16권4호
    • /
    • pp.396-402
    • /
    • 2014
  • 한반도의 봄철은 산수유, 매화, 목련, 진달래, 개나리, 벚꽃, 철쭉 등 다양한 꽃이 순차적으로 개화하는 동적인 경관을 특징으로 한다. 덕분에 지자체들은 봄꽃축제를 통해 관광수입을 올려왔으며, 봄꽃을 따라 남쪽에서 북쪽으로 이동하는 양봉업자는 장기간에 걸쳐 밀원을 확보할 수 있었다. 하지만 최근 봄꽃 개화일의 지역 간 차이와 화종 간 차이가 동시에 줄어들어 계절경관의 경제적, 공익적 가치가 훼손되고 있다. 대표적인 봄꽃인 개나리와 벚꽃의 개화일을 60년 이상 관측해온 6개 기상관서의 자료에 의하면, 먼저 피는 개나리와 늦게 피는 벚꽃의 개화일 편차가 1951-1980 평년에는 최장 30일, 평균 14일이었지만, 1981-2010 평년에는 최장 21일, 평균 11일로 단축되었다. 특히 2014년에는 7일로 단축되어 같은 장소에서 벚꽃과 개나리를 동시에 볼 수 있게 되었다. 또한 부산에서 서울까지 벚꽃전선이 이동하는 데 1951-1980 평년의 경우 20일이 소요되었으나 1981-2010 평년에는 16일로 줄었으며, 2014년에는 6일로 좁혀졌다. 같은 기간 개나리전선은 20일${\rightarrow}$17일${\rightarrow}$12일로 단축되었다. 두 봄꽃의 개화일이 근접해진 이유는 휴면해제 직후 이른 봄의 완만한 기온상승에 비해 늦은 봄의 급격한 기온상승으로 대표되는 한반도의 최근 기후변화양상이 일찍 피는 개나리보다 늦게 피는 벚꽃의 개화를 더욱 앞당겼기 때문으로 추정된다. 지난 60년간 자료로부터 온도시간을 기반으로 개화에 소요되는 고온요구량을 지점별로 도출하여 2014년의 개나리와 벚꽃 개화일을 추정한 결과 평방근오차 2일 이내의 좋은 성적을 얻었다.

슬러지 유중 건조에 대한 전산 해석 및 실험적 연구 (A Numerical and Experimental Study for Fry-drying of Various Sludge)

  • 신미수;김혜숙;김병갑;황민정;장동순;엄태인
    • 대한환경공학회지
    • /
    • 제32권4호
    • /
    • pp.341-348
    • /
    • 2010
  • 유중 건조 공정의 기본 원리는 수분과 비열차이가 있는 오일을 가열할 때 온도 차이에 따라 형성되는 슬러지 내부의 급격한 압력 변화를 이용한다. 즉 슬러지 내부에 발생하는 급격한 압력 상승이 이루어질 때 슬러지 공극을 통하여 수분이 빠르게 배출하도록 하는 것이다. 본 연구의 목적은 유중 건조공정 중 다양한 운전 변수가 건조효율에 미치는 영향을 구체적으로 규명하기 위한 것이다. 변수 연구를 위하여 일련의 건조 실험과 수치해석을 시도하였으며 그 결과 건조온도, 건조시간, 폐오일종류, 슬러지 종류 등 중요 실험변수에 따른 건조곡선이 얻어졌다. 건조 온도 변화에 따른 연구 결과는 폐오일의 종류에 관계없이 $140^{\circ}C$ 이상으로 운전하는 것이 건조효율에 유리한 것으로 나타났으며 이 결과는 수치 해석적 결과로도 확인되었다. 그리고 슬러지 직경의 경우 직경이 감소할수록 효율적으로 건조되는 경향으로 보였으며 이는 비표면적의 증가에 기인하는 것으로 판단되었다. 오일 종류나 물성의 변화에 대한 연구에서는 오일의 점도가 가시적인 영향을 주는 것으로 나타났다. 특히 점도가 높은 오일의 경우 건조 초반에 수분 증발이 현저히 지체되는 현상이 나타났다. 그러나 건조온도 $140^{\circ}C$ 이상에서는 이러한 지체 현상이 감소하는 결과를 나타내었다. 슬러지 종류에 따른 연구에서는 전체적으로 큰 차이를 나타내지는 않았으나 하수슬러지가 다른 종류의 슬러지에 비하여 좀 더 가시적으로 양호한 수분제거 양상을 나타내었다. 수치 해석적 연구는 실험적 연구에 대한 상호보완적인 연구로서 가능성을 보였으나 복잡한 세부모델에 대한 경험적인 모델개발의 필요성이 제기되었다.

드론을 활용한 지표온도와 흡수일사 간 공간적 상관관계 분석 - 쿨루프 효과 분석을 중심으로 - (Analysis of Spatial Correlation between Surface Temperature and Absorbed Solar Radiation Using Drone - Focusing on Cool Roof Performance -)

  • 조영일;윤동현;이명진
    • 대한원격탐사학회지
    • /
    • 제38권6_2호
    • /
    • pp.1607-1622
    • /
    • 2022
  • 본 연구의 목적은 도시폭염 저감을 위한 기법인 쿨루프를 연구지역에 적용하여 토지피복 객체 간 지표 온도와 흡수일사 간 공간적 상관관계 분석으로 실질적 효과 파악을 목적으로 한다. 이를 위해 실제 쿨루프가 적용된 경상남도 김해시 장유무계동 인근을 연구지역으로 선정하였으며, 드론 DJI Matrice 300 RTK에 열적외 영역센서 FLIR Vue Pro R, 가시광선 영역센서 H20T와 다중분광영역 센서인 Micasense Red-Edge를 활용하여 계측하였다. 계측 일정은 2021년 7월 27일 아침 7시 15분부터 약 1시간 30분 간격으로 총 9장의 열지도와 동일 시간대의 흡수일사 분포도, 쿨루프(113개) 및 일반옥상(367개) 지붕 객체를 추출하였다. 흡수일사 분포도는 ArcGIS의 3D 분석 기능인 Solar Radiation Analysis Tool을 통해 산출한 전천일사 분포도에 Micasense Red Edge를 통해 촬영한 Blue, Green Red, Near Infrared, Red Edge Range 영역대 센서의 조합을 통해 구축한 연구 지역의 알베도 값을 반영하여 구축한다. 전술된 자료를 기반으로 일반옥상과 쿨루프 지붕 객체별 지표온도와 흡수일사 간 Pearson 상관계수를 산출하였다. 분석 결과 일 평균 기준 일반옥상 0.550, 쿨루프 0.387의 상관계수 값을 나타내고 있었다. 하지만, 시간대별 상관성의 변화를 파악한 결과 분석일 기준 태양고도가 높은 시기인 11시 30분과 13시의 경우 일반옥상과 쿨루프 간 상관계수의 차이는 0.022, 0.024 값을 보여 유사한 상관성을 보이고 있다. 그 외 시간대는 일반옥상의 상관계수 값이 쿨루프 보다 약 0.1 이상 높은 값을 보이고 있다. 본 연구는 드론을 통해 취득한 고해상도 영상을 활용하여 쿨루프의 실질적 일사차단 영향의 가능성을 대조군이 되는 일반 옥상과의 상관성 비교를 통해 파악한 사례 연구이다. 향후 본 연구 결과를 기반으로 효율적인 도시열섬 저감기법 적용이 가능할 것으로 사료된다.