• 제목/요약/키워드: Heating source

검색결과 897건 처리시간 0.034초

태양열 이용 바이오메탄 분해 해석연구 (Simulation Analysis of Bio-Methane Decomposition Using Solar Thermal Energy)

  • 김하늘;이상남;이상직;김종규
    • 신재생에너지
    • /
    • 제17권1호
    • /
    • pp.40-49
    • /
    • 2021
  • In this study, the optical properties, heat transfer capabilities and chemical reaction performance of a methane thermal decomposition reactor using solar heat as a heat source were numerically analyzed on the basis of the cavity shape. The optical properties were analyzed using TracePro, a Monte Carlo ray tracing-based program, and the heat transfer analysis was performed using Fluent, a CFD program. An indirect heating tubular reactor was rotated at a constant speed to prevent damage by the heat source in the solar furnace. The inside of the reactor was filled with a porous catalyst for methane decomposition, and the outside was insulated to reduce heat loss. The performance of the reactor, based on cavity shape, was calculated when solar heat was concentrated on the reactor surface and methane was supplied into the reactor in an environment with a solar irradiance of 700 W/㎡, a wind speed of 1 m/s, and an outdoor temperature of 25℃. Thus, it was confirmed that the heat loss of the full-cavity model decreased to 13% and the methane conversion rate increased by 33.5% when compared to the semi-cavity model.

육상 수조식 양식장의 해수 열원 히트펌프 시스템 적용을 위한 열부하 분석 (Thermal load analysis of tank culture system for applying seawater source heat pump)

  • 윤민기;김태훈;정석권
    • 수산해양기술연구
    • /
    • 제59권2호
    • /
    • pp.155-163
    • /
    • 2023
  • This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.

지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES) (A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage)

  • ;한정상;한혁상;한찬;김형수
    • 자원환경지질
    • /
    • 제38권6호
    • /
    • pp.717-729
    • /
    • 2005
  • 일반적으로 대규모 건물의 피크 냉방 부하는 난방부하보다 크다. 북위도의 한냉한 지역에 소재한 대규모건물의 냉난방 설비는 건물 내부에서 생성되는 발열량과 태양으로부터 획득되는 열량에 따라 좌우된다. 최대 냉방부하에 적합하도록 냉난방설비와 지중루프를 설치하는데 소요되는 비용은 일반적으로 초기투자비가 적게 드는 전통적인 HVAC시스템에 비해 다소 고가이다. 빙축열조(Thermal ice storage, TES)시스템은 과거 수년동안 일반 HVAC에서 냉동기의 용량을 축소시키거나 최대 전력부하 시간대를 바꾸기 위해 사용되어온 기술이다. 일반적으로 건물 난방을 위해서는 보일러와 같은 전통적인 난방설비를 이용하고 그 다음날의 건물냉방을 위해서는 전력료가 저렴한 야간에 빙축을 시키는 빙축열기법을 이용한다. 얼음에서 추출한 잠열 에너지의 장점을 이용하기 위해 설계된 분배시스템(distribution system)과 열원과 열배출원(열침, sink)대신에 지중열 교환기(지중루프)를 이용하면 많은 장점이 있다. 공간 난방과 급탕을 공급하기위한 분리형 설비를 별도로 사용하지 않아도 된다. 공간난방용으로 소요되는 설비용량을 축소시킬 수 있으며-소요 지중열 교환기의 규격과 비용을 절감시킴은 물론 지열 HVAC시스템의 효율을 배가 시킬 수 있으며 온실가스 배출량을 대폭 감축시킬 수 있다. 또한 TES를 적용하면 대규모 건물의 냉난방부하와 열펌프의 용량을 $40\~60\%$ 정도 감축시킬 수 있으며 설비대수와 기계실 공간을 줄일 수 있다. 뿐만아니라 피크 냉난방부하를 토대로 설계한 지원 열펌프 시스템(Ground source heat pump system)의 지중루프를 $1/4\~1/3$가지 줄일 수 있어 도심지역에서 지중루프를 설치할 때 장애요인인 지중루프 설치공간문제와 지중암석의 열적특성문제를 동시에 해결할 수 있다.문이며, 따라서 $^{137}Cs$의 분포는 광물분포 보다는 TOC의 함량에 더 큰 영향을 받고 있음을 보여준다.과 위기 고조 단계, 그리고 갈등 해소 단계등 모든 시기에서 두 신문의 주요 행위자 구성에 있어서 차이가 나타났다. 다시 말해, 조선일보는 기본적으로 총파업을 둘러싼 문제의 구성과 발전, 해소 과정에서 정당이나 대통령, 야당 지도자 등과 같은 정치관련 행위자를 강조하고 있었다. 반면에, 한겨레는 대체로 로든 사건진행 단계에서 노동 관련 단체들과 시민단체의 역동적인 연대와 활동에 초점을 맞추고 있는 것으로 나타났다.술 후 24시간에 599.4$\pm$145.6, 678.8 $\pm$256.4였다(t-test, p < 0.05). 동종 수혈은 RAP군에서 34명 중 7명에서(20.6$\%$), 대조군에서는 46명중 16명에서(34.8$\%$) 시행되어, RAP군에서 유의하게 빈도가 낮았다(Chi-square test, p < 0.05). 결론: 역행성 자가 충전법은 심폐바이패스의 충전에 의한 혈액희석을 최소화함으로서, 개심술 후 출혈과 동종수혈을 또한 줄이는 데 효과적인 방법이 될 수 있다고 생각된다.타내지 않았다.성 교사, 가정 전공 교사가 그렇지 않은 교사보다 해석적, 해방적 행동목표를 더 중요하게 인식하고 있었다. 특히 가정교육 철학을 배운 경험이 있는 교사가 그렇지 않은 교사보다 해방적 행동체계 목표를 중요시하는 것으로 나타났다. 이 연구 결과는, 실천 비판적인 가정 교과의 본질을 구현하기 위해서는 주생활 영역의 교육과정에 기술적, 해석적, 해방적 행동에 대한 목표들을 고루 포함하여야 하며 특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한

연료전지 차량의 냉시동성 개선을 위한 금속 분리판 표면의 바나듐 산화물 박막 제조 및 특성 분석에 관한 연구 (An Experimental Study of Synthesis and Characterization of Vanadium Oxide Thin Films Coated on Metallic Bipolar Plates for Cold-Start Enhancement of Fuel Cell Vehicles)

  • 정혜미;노정훈;임세준;이종현;안병기;엄석기
    • 대한기계학회논문집B
    • /
    • 제35권6호
    • /
    • pp.585-592
    • /
    • 2011
  • 냉시동 성능 개선은 연료전지 차량의 고분자 전해질 연료전지 발전 모듈 및 시스템의 내구성과 신뢰성 향상의 측면에서 매우 중요하다. 이에 본 연구에서는 영하의 기후에서 연료전지 차량의 초기 구동 시금속 분리판 표면에 형성된 바나듐 산화물 박막의 자기 발열 특성을 이용하여 신속한 온도 상승 구현이 가능한 냉시동 향상 기술을 제안하고, 실험적 방법을 통해 그 적용 가능성을 검증하였다. 졸-겔 침지 법에 의해 제조된 바나듐 산화물 박막의 특성 평가를 위해 X 선 회절, 광전자 분광, 전자 주사 현미경을 이용한 화합물 조성 및 미세구조 분석, 4-탐침법을 이용한 $-20{\sim}80^{\circ}C$의 온도 구간에서의 온도-저항 이력 특성 분석을 각각 수행하였다. 본 실험 결과, 냉시동 조건에서 박막의 자기 발열량은 연료전지 내부의 생성 수 결빙 방지에 필요한 열 에너지를 모두 충족시킬 수 있음을 확인하였다.

Candida muscorum의 Amylase에 관(關)한 연구(硏究) (Studies on the Amylase Produced by Candida muscorum)

  • 박윤중;윤한교;손천배
    • 한국식품과학회지
    • /
    • 제7권4호
    • /
    • pp.243-249
    • /
    • 1975
  • 분리보존중(分離保存中)인 Candida muscorum의 밀기울 고체배양(固體培養)에 있어서의 amylase 생성조건(生成條件)과 그 amylase(조효소(粗酵素))의 성질(性質)에 대(對)하여 검토(檢討)한 결과(結果)는 다음과 같다. 1. 밀기울 고체배양(固體培養)에 있어서 amylase의 최적생산조건(最適生産條件)은 가수량(加水量) 75%, 배양온도(培養溫度) $25^{\circ}C$, 배양기간(培養期間) $4{\sim}7$일(日)이었다. 2. 밀기울에 ${(NH_4)}_2SO_4$$NH_4Cl$을 0.5% 첨가(添加)한 배지(培地)에서는 액화효소(液化酵素) 및 당화효소(糖化酵素)의 생성(生成)이 약(約) 20% 증가(增加)되었으며, $NO_3$태질소화합물(態窒素化合物) 첨가배지(添加培地)에서는 효소(酵素) 생성(生成)이 저해(沮害)되었다. 3. Amylase 생성(生成)에 있어서 탄소원(炭素原) 첨가효과(添加效果)는 없었다. 4. 실험균주(實驗菌株)의 액화효소(液化酵素)의 작용최적(作用最適) pH는 4.2, 작용최적온도(作用最適溫度)는 $60{\sim}65^{\circ}C$, 안정(安定) pH 범위(範圍)는 $3.2{\sim}6.8$, 내열성(耐熱性)은 $65^{\circ}C$이하(以下)(15분간(分間) 처리(處理))이었다. 5. 실험균주(實驗菌株)의 당화효소(糖化酵素)의 작용최적(作用最適) pH는 4.5, 작용최적온도(作用最適溫度)는 $55^{\circ}C$, 안정(安定) pH범위(範圍)는 $3.8{\sim}6.2$, 내열성(耐熱性)은 $45^{\circ}C$이하(以下)(15분간(分間) 처리(處理))이었다.

  • PDF

탄소순환마을의 이산화탄소배출량 조사연구 (경상북도 봉화군 춘양면 서벽리를 중심으로) (Inventory of Carbon Dioxide Emission in Carbon Cycle Community (The case study on Gyeongbuk Bonghwa-gun Chunyang-myeon Seobyeok-ri))

  • 김효진;변우혁;임민우;박원경;김민수
    • 한국산림과학회지
    • /
    • 제99권4호
    • /
    • pp.597-602
    • /
    • 2010
  • 산림탄소순환마을 조성을 위한 가장 기본적인 사항은 온실가스 배출에 관한 통계인데 현재 시 도 단위의 온실가스 배출 통계는 존재하나 마을단위의 온실가스 배출에 관한 통계가 없다. 따라서 본 연구에서 마을단위의 온실가스 배출량에 대한 자료를 구축하여 탄소순환마을의 탄소수지에 관한 모델을 제시하고자 하였다. 연구수행결과, 시범대상지인 경상북도 봉화군 춘양면 서벽리의 에너지사용에 따른 이산화탄소 배출량은 $1,755tCO_2$이며 그 중 난방 사용에 의한 배출량이 55%로 가장 많은 비중을 차지하며 전력 23%, 차량 22%의 순으로 나타났다. 벼농사와 가축 등 농업으로 인해 총 $572tCO_2$의 이산화탄소가 배출되었다. 이는 에너지 사용과 농업부문에서 발생하는 이산화탄소 총 배출량 $2,327tCO_2$의 약 24.5%를 차지했다. 또한, 모델지역에서 사용되는 난방에너지를 우드칩이나 펠릿 등 목재 바이오에너지로 대체할 경우 년간 약 1,580 ton의 목재가 소비될 것이며 난방에서 발생하는 이산화탄소배출량은 $964tCO_2$의 1/12인 $80tCO_2$$884tCO_2$ 만큼의 탄소가 저감 될 것으로 예상된다.

Development of Semi-basement Type Greenhouse Model for Energy Saving

  • Kim, Seoung Hee;Joen, Jong Gil;Kwon, Jin Kyeong;Kim, Hyung Kweon
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.328-336
    • /
    • 2016
  • Purpose: The heat culture areas of greenhouses have been continuously increasing. In the face of international oil price fluctuations, development of energy saving technologies is becoming essential. To save energy, auxiliary heat source and thermal insulation technologies are being developed, but they lack cost-efficiency. The present study was conducted to save energy by developing a conceptually new semi-basement type greenhouse. Methods: A semi-basement type greenhouse, was designed and constructed in the form of a three quarter greenhouse as a basic structure, which is an advantageous structure to inflow sunlight. To evaluate the performance of the developed greenhouse, a similar structured general greenhouse was installed as a control plot, and heating tests were conducted under the same crop growth conditions. Results: Although shadows appeared during the winter in the semi-basement type greenhouse due to the underground drop, the results of crop growth tests indicated that there were no differences in crop growth and development between the semi-basement type greenhouse and the control greenhouse, indicating that the shadows did not affect the crop up to the height of the crop growing point. The amount of fuel used for heating from January to March was almost the same between the two greenhouses for tests. The heating load coefficients of the experimental greenhouses were calculated as $3.1kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the semi-basement type greenhouse and $2.9kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the control greenhouse. Since the value is lower than the double layer PE (polyethylene) film greenhouse value of $3.5kcal/m^2{\cdot}^{\circ}C{\cdot}h$ from a previous study, Tthe semi-basement type greenhouse seemed to have energy saving effects. Conclusions: The semi-basement type greenhouse could be operated with the same fuel consumption as general greenhouses, even though its underground portion resulted in a larger volume, indicating positive effects on energy saving and space utilization. It was identified that the heat losses could be reduced by installing a thermal curtain of multi-layered materials for heat insulation inside the greenhouse for the cultivation of horticultural products by installing thermal curtain of multi-layered materials for heat insulation inside the greenhouse, it was identified that the heat losses could be reduced.

신재생에너지 기기로서 히트펌프의 신재생에너지 생산량 (Renewable Energy Production by Heat Pump as Renewable Energy Equipment)

  • 홍희기;최준영;임신영
    • 설비공학논문집
    • /
    • 제29권10호
    • /
    • pp.551-557
    • /
    • 2017
  • Most European economies, Japan, and many governments have made it a major policy to expand the green business by disseminating heat pump technology, which has a large $CO_2$ reduction effect. The heat pump of all heat sources has been recognized as renewable energy and the policy to encourage has been implemented. In the recently revised Renewable Energy Law, the hydrothermal source (surface sea water) heat pump was newly included in renewable energy. In addition, the scope of application of heat pumps has expanded in the mandatory installation of renewable energy for new buildings, remodeling buildings, and reconstructed buildings based on this law. However application to heat pumps using all natural energy as heat source has been put off. In this revision, the ratio of renewable energy to the total energy produced by the heat pump was fixed at 73%, which depends on coefficient of performance of heat pump. The ratio of renewable energy is $1-1.8/COP_H$, and should be calculated including the coefficient of performance of the heat pump. Using a high efficiency heat pump or a high-temperature heat source increases the coefficient of performance and also reduces $CO_2$ emissions. It is necessary to expand the application of heat pumps as renewable energy equipment and to improve the correct calculation of renewable energy production.

국제 호환형 지열히트펌프 시스템 경제성 평가 연구 (International Harmonized Economic Assessment Study of a Ground Source Heat Pump System)

  • 나선익;강은철;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권1호
    • /
    • pp.7-13
    • /
    • 2014
  • This study intends to analyse the economical aspect of a GSHP(Ground Source Heat Pump) system compared to the conventional system which is consisted with a boiler and a chiller. This study has simulated four systems in Incheon. It developed and analyzed for applications in a residential and an office building which was based on the hourly EPI(Energy Performance Index, $kWh/m^2yr$). Case 1 is utilizing a boiler and a chiller to meet heating and cooling demand of a house. Case 2 is utilizing the same conventional set up as Case 1 of a office. Case 3 is summation of Case 1(house) and 2(office) systems and loads. And Case 4 is utilizing a GSHP to meet the combined loads of the house and office. The method of the economic assessment has been based on IEA ECBCS Annex 54 Subtask-C SPB(Simple Payback) method. The SPB calculated the economic balanced year of the alternative system over the reference system. The SPB of the alternative systems (GSHP) with 10%, 30% and 50% initial incentive has been calculated as 9.38, 6.72 and 4.06 year respectively while the SPB without initial incentive of systems was 10.71 year.

가변출력전압 AC/DC 컨버터를 이용한 파라메트릭 어레이 트랜스듀서용 고효율 전력증폭기의 설계 (Design of High Efficiency Power Amplifier for Parametric Array Transducer using Variable Output Voltage AC/DC Converter)

  • 심재혁;이창열;김슬기;김인동;문원규;이종현;김원호
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.364-375
    • /
    • 2014
  • Parametric array transducers are used for long-range and highly directional communication in an underwater environments. The power amplifiers for parametric array transducers should have sufficient linear output characteristic and high efficiency to avoid communication errors, system heating, and fuel problems. But the conventional power amplifier with fixed source voltage is very low efficient due to large power loss by the big difference between the fixed source voltage and the amplifier output voltage. Thus to solve the problems this paper proposes the high efficiency power amplifier for parametric array transducers. The proposed power amplifier ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier and furthermore gets high efficiency by applying the envelope tracking technique that variable source voltage tracks the envelope of the amplified signal. Also the paper suggests the detailed circuit topology and design guideline of class B push-pull type amplifier and variable output voltage AC/DC converter. Its characteristics are verified by the detailed simulation and experimental results.